Animation of Fermilab's Accelerator Complex

The 6,800-acre Fermilab site is home to a chain of particle accelerators that provide particle beams to numerous experiments and R&D programs. This 2-minute animation explains how the proton source provides the particles that get accelerated and travel through the accelerator complex at close to the speed of light. Scientists use these beams to generate protons, neutrons, muons, pions and neutrinos for various research areas across the Fermilab site. More than 4,000 scientists from over 50 countries use Fermilab and its particle accelerators, detectors and computers for their research. More information is at http://www.fnal.gov/pub/science/.

43 PARTICLE ACCELERATORS↗

Search for CPT and Lorentz invariance violation in the muon $g -2$ experiment at Fermilab

The Muon g-2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon, $a_{\mu}= (g-2)/2$, to a groundbreaking precision of $140$ ppb, obtaining a near four-fold increase in precision over the previous experiment, E821, at the Brookhaven National Laboratory (BNL). The value of $a_{\mu}$ from BNL currently differs from the Standard Model prediction by $\sim 3.7$ standard deviations, suggesting the potential for new physics and therefore, motivating a new experiment.Because the theory predicts this number with high precision, testing the g-factor through experiment provides a stringent test of the SM and can suggest physics beyond the Standard Model. The goal of the Fermilab Muon $g-2$ experiment is to increase the statistical precision by more than a factor of 20 and reduce systematic errors by a factor of 3. By measuring muon precession rate ($\omega_a$) in an external magnetic field, the anomalous magnetic moment will be calculated. This is an incredibly challenging experiment with a unique opportunity to provide new insight into nature. \\ The $g-2$ data also provides a great opportunity for setting the most stringent limits on some of the Standard Model Extension CPT Lorentz violating (LV) parameters in the muon sector. One of the CPT and Lorentz violating signatures that we can look for using $g-2$ data is a sidereal variation of $\omega_a(t)$. Extensive simulation studies confirm that the sensitivity regarding the sidereal varation roughly scales with $\omega_a$ uncertainty. Hence, the $g-2$ experiment at FNAL should be able to reach limits of $\sim 5\times10^{-25}$ GeV. Because the CPT and LV analyses are essentially studies of variations in $\omega_a$ as a function of time and charge, performing an $\omega_a$ analysis sets the stage for the CPT and LV measurement. This dissertation focuses on the methodology of a fully functioning framework and analyzing the Fermilab Muon $g - 2$ Run 2 data containing $\sim 11$ billion events above an energy threshold of $1.7$~GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the muon spin precession frequency using the straw tracking detectors at the Fermilab Muon g-2 experiment

The measurement of the anomalous magnetic dipole moment of the muon ($a_{\mu}$) has long stood as an excellent precision test of the Standard Model (SM). The Fermilab Muon g-2 experiment has recently finished data-taking and in July 2023 published its latest determination of $a_\mu$ with a world-leading precision of 0.2\,ppm. In this publication, it surpassed the systematic uncertainty goal defined in the TDR. The analyses of a dataset approximately four times larger than this recent publication is now underway. The principle measurement of the Muon g-2 experiment measures $a_{\mu}$ by taking the ratio of two frequencies; the anomalous precession frequency ($\omega_a$) and the muon-weighted magnetic field of the experiment's storage ring measured from the precession frequency of protons in water using nuclear magnetic resonance (NMR) probes. In all publications to date, $\omega_a$ has been determined using energy deposits in the 24 calorimeters. However, the Fermilab experiment has t wo straw tracker detectors measuring the time and momentum of charged particles which can in principle also be used to to measure $\omega_a$ and such a measurement can provide an invaluable cross-check of the calorimeter result with different, and reduced, systematic uncertainties. This thesis presents the first (blinded) determination of $\omega_a$ using just charged tracks from the straw tracking detectors as opposed to calorimeter energy deposits. This analysis was undertaken using the Run-2/3 dataset which represents approximately 25\% of the final dataset. A total uncertainty of 2.19\,ppm on $\omega_a$ was obtained which is dominated by the statistical uncertainty of 2.16\,ppm. Additionally two new methodologies important to the analysis of the straw tracking data have been developed: one to better determine the track arrival time ($t_0$) and one to determine the level of pileup in the tracking detectors. The new $t_0$ algorithm which incorporates angular information improves t he resolution on the determination of the $t_0$ by a factor of two and results in 19\% more tracks being successfully reconstructed. The data from the trackers is also used to determine the beam profile that weights the magnetic field in the determination of $a_\mu$ and in determining several of the systematic uncertainties in the calorimeter-based $\omega_a$ analysis. A detailed study of the impact of the internal alignment of the tracker, the $t_0$ and pileup on the determination of the beam position was undertaken and propagated through to an uncertainty in the $\omega_a$ determination. These uncertainties were used in the Fermilab Muon g-2 experiment's recent publication in Phys. Rev. Lett.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The precision measurement of the muon $g-2$ at Fermilab

The Muon $g-2$ Experiment at Fermilab aims to measure the magnetic anomaly of the muon with the unprecedented precision of 140 parts per billion. In April 2021, the collaboration published the first measurement based on the first year of data collection, which was found to be consistent with the previous experiment at Brookhaven. The new global average of the experimental measurements strengthens the long-standing tension with the data-driven Standard Model prediction to a combined discrepancy of 4.2$\sigma$. On the theory side, however, recent improvements in the theoretical calculation of the hadronic contribution based on Lattice-QCD techniques are introducing new tensions on the value predicted by the theory. The Muon $g-2$ Experiment at Fermilab has now concluded its sixth and final year of data taking and a new result based on the Run-2 and Run-3 data was published in August 2023. This paper briefly describes the precision measurement conducted by the Muon $g-2$ Experiment at Fermilab and its current status.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Couplers in the Fermilab Spoke Test Cryostat

As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.

43 PARTICLE ACCELERATORS↗

A Novel Measurement of the Anomalous Muon Spin Precession Frequency in the Muon $g-2$ Experiment at Fermilab

The Muon $g-2$ Experiment operated at Fermi National Accelerator Laboratory (FNAL, or Fermilab) between 2018 and 2023 to produce the world's most precise measurement of the muon's \textit{anomalous magnetic moment}, $a_\mu = \frac{g_\mu - 2}{2}$, which expresses the relative deviation in the muon's $g$-factor from a baseline theoretical expectation that $g_\mu = 2$. In the Standard Model of particle physics, $g_\mu > 2$ and hence $a_\mu > 0$ by a calculable amount that depends on all possible interactions between the muon and all other fundamental particles, including any potentially undiscovered interactions beyond the Standard Model. For this reason, measurements of the electron anomaly $a_e$ and later the muon anomaly $a_\mu$ have helped guide the development of the Standard Model since the inception of quantum field theory, and the measured value of $a_\mu$ provides a valuable constraint for new hypotheses that extend the Standard Model. As of 2006, the leading measurement and Standard Model prediction for $a_\mu$ exhibited tension at the level of about three standard deviations, motivating an improved measurement at Fermilab that could test the tension more precisely. The experiment functions by storing a polarized beam of $\mu^+$ in a uniform magnetic field, which simultaneously induces circular motion and spin precession. As the stored muons undergo the Michel decay $\mu^+ \to e^+ + \nu_e + \bar{\nu}_\mu$, mediated by the parity-violating weak interaction, the rest-frame $e^+$ emission direction is correlated with the parent $\mu^+$ spin orientation. Boosting into the laboratory frame encodes this correlation in the decay $e^+$ energy, which is higher when the emission (i.e. $\mu^+$ spin direction) is aligned with the $\mu^+$ momentum, and lower when opposite. Detectors then count the rate of high-energy decay $e^+$, which modulates at the difference between the $\mu^+$ revolution and spin precession frequencies. This observed frequency, called the \textit{anomalous spin precession frequency} $\omega_a$, is directly proportional to $a_\mu$. The extraction of $\omega_a$ proceeds by fitting the time spectrum of detected $e^+$, which requires precise modeling of the $\omega_a$ oscillation as well as any perturbations from beam dynamics and detector acceptance. Using the $\omega_a$ analysis presented in this work, based on Runs 4 -- 6 of the Muon $g-2$ Experiment at Fermilab, we find that $a_\mu = 0.001\,165\,920\,738(162)$ with a relative uncertainty of 139 parts per billion.

Barrett, Tyler [Cornell U.]↗

A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab

A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, the quench controls and data management system. The Tier-I and Tier-II are completely independent and fully redundant systems. The Tier-3 system is based on National Instruments (NI) C-RIO and provides the user interface for quench controls and data management. It is independent from Tiers I & II. The DQD provides both quench detection and quench characterization (monitoring) capability. Both DQD and AQD have built-in high voltage isolation and user programmable gains and attenuations. The DQD and AQD also includes user configured current dependent thresholding and validation times. A 1 st article of the three-tier system was fully implemented on the new Fermilab magnet test stand for the HL-LHC Accelerator Up-grade Project (AUP). It successfully provided quench protection and monitoring (QPM) for a cold superconducting bus test in November 2020. The Mu2e quench detection design has since been implemented for production testing of the AUP magnets. A detailed description of the system along with results from the AUP superconducting bus test will be presented.

monitoring↗

Fermilab VALOR Program

The Veteran Applied Laboratory Occupational Retraining (VALOR) Program is an expansion of Fermilab’s established VetTech internship program originally initiated in 2016. The enhanced program seeks to recruit, hire, train, and retain veterans and transitioning service members by providing multiple entry points for full time STEM-based careers at Fermilab. VALOR is comprised of four paid internships/apprenticeships supplemented by professional development opportunities.

Fermilab, Fermilab↗

Magnetic Measurements of Fermilab Rapid-Cycling Booster Gradient Magnets

Fermilab is upgrading its Booster synchrotron to increase ramp rate and intensity. This is part of the Proton Improvement Plan (PIP-II) that will allow the Main Injector to achieve proton beam power of 1.2 MW within the next few years. This upgrade includes running the 55-year-old Booster magnets at 20 Hz instead of the usual 15 Hz, and construction of some shorter and wider aperture versions of these combined-function gradient magnets. Magnetic measurements were performed to characterize the present 15 Hz AC performance, and then again with 20 Hz ramp cycle to ensure performance and compatibility in this new operating regime. A 3 m-long curved flat-coil was developed for these measurements using Printed Circuit Board (PCB) technology. The probe also has a separate 0.5 m-long body-field probe, allowing integral, body, and end fields to be measured across 100 mm of the magnet aperture. The sampling rate for these measurements during the AC cycle was 200 kHz, and field resolution was better than 0.01%. Details of the probe, measurements, and results are presented.

DiMarco, J. [Fermilab] (ORCID:0000000228400036)↗

Advancing Conduction-Cooled 650 MHZ SRF Technology for Industrial Accelerators at Fermilab S IARC

The National Nuclear Security Administration (NNSA) funds the Illinois Accelerator Research Center (IARC) at Fermilab in developing a high-power, conduction-cooled Superconducting Radio Frequency (SRF) accelerator tailored for industrial applications requiring robust and efficient operation. A 650 MHz, 1.6 MeV, 20 kW SRF accelerator is currently under development, employing a conduction cooling approach to simplify cryogenic requirements and enhance accessibility for industrial use. The accelerator's control system is implemented on the Blinky Lite platform, selected for its open-source architecture, secure remote access capabilities, and operational flexibility attributes advantageous for industrial deployment and sustained operation. A dedicated beamline is designed to measure essential beam parameters and test the integrated performance of the accelerator and control systems, thereby validating their operational readiness for intended applications.

Ji, Yichen [Fermilab]↗

Slow Extraction Beam Commissioning for the Mu2e Experiment at Fermilab

Following the successful completion of the Muon g-2 experiment run at Fermilab, the Muon Campus facility has been reconfigured from delivering 3 GeV muon beams to the g-2 storage ring to providing slow-extracted 8 GeV proton beam spills for the Mu2e experiment. The first full-scale commissioning run with slow extraction was conducted during the 2025 run, followed by the second run in early 2026. We present the results and current status of this commissioning campaign.

Nagaslaev, V. [Fermilab]↗

Advancing Conduction-Cooled 650 MHz SRF Technology for Industrial Accelerators at Fermilab's IARC

The National Nuclear Security Administration (NNSA) funds the Illinois Accelerator Research Center (IARC) at Fermilab in developing a high-power, conduction-cooled Superconducting Radio Frequency (SRF) accelerator tailored for industrial applications requiring robust and efficient operation. A 650 MHz, 1.6 MeV, 20 kW SRF accelerator is currently under development, employing a conduction cooling approach to simplify cryogenic requirements and enhance accessibility for industrial use. The accelerator’s control system is implemented on the Blinky Lite platform, selected for its open-source architecture, secure remote access capabilities, and operational flexibility—attributes advantageous for industrial deployment and sustained operation. A dedicated beamline is designed to measure essential beam parameters and test the integrated performance of the accelerator and control systems, thereby validating their operational readiness for intended applications

Ji, Y. [Fermilab] (ORCID:0000000233981752)↗

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m$^3$ membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

43 PARTICLE ACCELERATORS↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Slow Extraction Beam Commissioning for the Mu2e Experiment at Fermilab

Following the successful completion of the Muon g-2 experiment run at Fermilab, the Muon Campus facility has been reconfigured from delivering 3 GeV muon beams to the g-2 storage ring to providing slow-extracted 8 GeV proton beam spills for the Mu2e experiment. The first full-scale commissioning run with slow extraction was conducted during the 2025 run, followed by the second run in early 2026. We present the results and current status of this commissioning campaign.

Nagaslaev, V. [Fermilab] (ORCID:0000000235719205)↗

Transfer of EP and Doping Technology for PIP-II HB650 Cavities from Fermilab to Industry

Fermilab has optimized the surface processing conditions for PIP-II high beta 650 MHz cavities. This encompasses conditions for bulk electropolishing, heat treatment, nitrogen doping, post-doping final electropolishing, and post-processing surface rinsing. The technology has been effectively transitioned to industry. This paper highlights the efforts made to fine-tune the process and to smoothly share them with the partner labs and an associated vendor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast Adaptive Neural Control of Resonant Extraction at Fermilab

We present progress on the development of a machine learning (ML) regulation system for third-order resonant extraction of the beam delivered to the Mu2e experiment at Fermilab. We consider classical and ML-based controllers optimized on semi-analytic simulations and provide performance comparisons for several models. Additionally, we discuss the efficiency of each model in training, which has implications for future work on adaptive control. We also discuss progress on developing optimized implementations of ML models for edge-based inference.

Whitbeck, A. [Fermilab] (ORCID:0000000342245164)↗

FPGA-Based Spill Regulation System for the Muon Delivery Ring at Fermilab

The Muon to Electron Experiment (Mu2e) requires a uniform beam profile from the Muon Delivery Ring to meet their experimental needs. A specialized Spill Regulation System (SRS) has been developed to help achieve consistent spill uniformity. The system is based on a custom-designed carrier board featuring an Arria 10 SoC, capable of executing real-time feedback control. The FPGA processes beam pulses of approximately 200 ns every 1.695 $μ$s, allowing for continuous monitoring of the extracted spill intensity through fast bunch integration. The system directly controls three quadrupole magnets, which work in conjunction with sextupole magnets to achieve third-order resonant extraction. Furthermore, the board interfaces with Fermilab's Accelerator Control Network (ACNET), enabling operators to modify spill regulation settings in real-time via the control network while providing diagnostic waveforms. These waveforms help operators monitor the process and fine-tune the feedback mechanisms. This paper presents an overview of the board's architecture and its initial progress toward regulating beam extraction. This initial version of the regulation system aims to evaluate baseline performance to inform future system improvements.