Search NASASearch

SEARCH · Search NASA

Results for “Fluid System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Numerical simulation of forced convection in a two fluid layered system in a floating zone configuration

Forced convection due to rotational effects has been numerically studied in a stable two-fluid layered system in which the lighter fluid occupies the upper portion of the computational and physical domain. Results are presented for three different fluid height combinations for conditions prevailing in a microgravity environment. It is found that the heavier fluid tends to dominate the flow field, and that equal corotation and counterrotation cases produce nearly identical behavior in the flow and thermal fields.

Ramachandran, N.

Personal Computer Transport Analysis Program

The Personal Computer Transport Analysis Program (PCTAP) is C++ software used for analysis of thermal fluid systems. The program predicts thermal fluid system and component transients. The output consists of temperatures, flow rates, pressures, delta pressures, tank quantities, and gas quantities in the air, along with air scrubbing component performance. PCTAP s solution process assumes that the tubes in the system are well insulated so that only the heat transfer between fluid and tube wall and between adjacent tubes is modeled. The system described in the model file is broken down into its individual components; i.e., tubes, cold plates, heat exchangers, etc. A solution vector is built from the components and a flow is then simulated with fluid being transferred from one component to the next. The solution vector of components in the model file is built at the initiation of the run. This solution vector is simply a list of components in the order of their inlet dependency on other components. The component parameters are updated in the order in which they appear in the list at every time step. Once the solution vectors have been determined, PCTAP cycles through the components in the solution vector, executing their outlet function for each time-step increment.

DiStefano, Frank, III

Thermal Analysis System

A thermal fluid system modeler including a plurality of individual components. A solution vector is configured and ordered as a function of one or more inlet dependencies of the plurality of individual components. A fluid flow simulator simulates thermal energy being communicated with the flowing fluid and between first and second components of the plurality of individual components. The simulation extends from an initial time to a later time step and bounds heat transfer to be substantially between the flowing fluid, walls of tubes formed in each of the individual components of the plurality, and between adjacent tubes. Component parameters of the solution vector are updated with simulation results for each of the plurality of individual components of the simulation.

DiStefano, III, Frank James

Free vibration analysis of coupled fluid-structure systems

An efficient numerical technique for the eigenvalue solution in the free vibration analysis of compressible fluid-structure coupled systems is presented. The fluid is assumed to be compressible in nature and the incompressible problem is only a special case of the present generalized algorithm. A natural frequency analysis of the structure in the absence of any fluid is achieved by a combined Sturm sequence and inverse iteration technique that computes only the required eigenvalues and vectors. A special inverse iteration scheme is then developed for the coupled system that uses the computed eigenvalues as starting iteration values for convergence. Numerical results obtained by solving a number of standard test cases indicate the pattern of root convergence corresponding to various simplifying assumptions.

Gupta, K. K.

Intravenous Fluid Generation System

The ability to stabilize and treat patients on exploration missions will depend on access to needed consumables. Intravenous (IV) fluids have been identified as required consumables. A review of the Space Medicine Exploration Medical Condition List (SMEMCL) lists over 400 medical conditions that could present and require treatment during ISS missions. The Intravenous Fluid Generation System (IVGEN) technology provides the scalable capability to generate IV fluids from indigenous water supplies. It meets USP (U.S. Pharmacopeia) standards. This capability was performed using potable water from the ISS; water from more extreme environments would need preconditioning. The key advantage is the ability to filter mass and volume, providing the equivalent amount of IV fluid: this is critical for remote operations or resource- poor environments. The IVGEN technology purifies drinking water, mixes it with salt, and transfers it to a suitable bag to deliver a sterile normal saline solution. Operational constraints such as mass limitations and lack of refrigeration may limit the type and volume of such fluids that can be carried onboard the spacecraft. In addition, most medical fluids have a shelf life that is shorter than some mission durations. Consequently, the objective of the IVGEN experiment was to develop, design, and validate the necessary methodology to purify spacecraft potable water into a normal saline solution, thus reducing the amount of IV fluids that are included in the launch manifest. As currently conceived, an IVGEN system for a space exploration mission would consist of an accumulator, a purifier, a mixing assembly, a salt bag, and a sterile bag. The accumulator is used to transfer a measured amount of drinking water from the spacecraft to the purifier. The purifier uses filters to separate any air bubbles that may have gotten trapped during the drinking water transfer from flowing through a high-quality deionizing cartridge that removes the impurities in the water before entering the salt bag and mixing with the salt to create a normal saline solution.

McQuillen, John

Design considerations for a micro-g superfluid helium fluid acquisition system

The general description, the operation, and the design of a superfluid helium (SFHe) fluid acquisition system (FAS) for use under microgravity conditions is presented. For the type of FAS considered here, where fine-mesh woven screens are used to retain flowing SFHe within a gallery arm (flow) channel, those forces which determine the flow dynamics are the micro-g accelerations, liquid surface tension, and tensile strength and cumulative pressure drops along a flow path that begins at the bulk liquid and ends at the entrance to a pump. For this case, the dimensionless number, N(T) is written as the ratio between the pressure drop across the screen and the surface tension forces at the screen for low fluid velocities. Static Bond number measurements have bene taken for SFHe using 325 x 2300 twilled Dutch screen and have indicated a screen pore hydraulic radius of 0.00031 cm.

Lee, J. M.

Thermal Vibrational Convection in a Two-phase Stratified Liquid

The response of a two-phase stratified liquid system subject to a vibration parallel to an imposed temperature gradient is analyzed using a hybrid thermal lattice Boltzmann method (HTLB). The vibrations considered correspond to sinusoidal translations of a rigid cavity at a fixed frequency. The layers are thermally and mechanically coupled. Interaction between gravity-induced and vibration-induced thermal convection is studied. The ability of applied vibration to enhance the flow, heat transfer and interface distortion is investigated. For the range of conditions investigated, the results reveal that the effect of vibrational Rayleigh number and vibrational frequency on a two-phase stratified fluid system is much different than that for a single-phase fluid system. Comparisons of the response of a two-phase stratified fluid system with a single-phase fluid system are discussed.

Chang, Qingming

In-flight demonstration of the Space Station Freedom Health Maintenance Facility fluid therapy system (E300/E05)

The Space Station Freedom (SSF) Health Maintenance Facility (HMF) will provide medical care for crew members for up to 10 days. An integral part of the required medical care consists of providing intravenous infusion of fluids, electrolyte solutions, and nutrients to sustain an ill or injured crew member. In terrestrial health care facilities, intravenous solutions are normally stored in large quantities. However, due to the station's weight and volume constraints, an adequate supply of the required solutions cannot be carried onboard SSF. By formulating medical fluids onboard from concentrates and station water as needed, the Fluid Therapy System (FTS) eliminates weight and volume concerns regarding intravenous fluids. The first full-system demonstration of FTS is continuous microgravity will be conducted in Spacelab-Japan (SL-J). The FTS evaluation consists of two functional objectives and an in-flight demonstration of intravenous administration of fluids. The first is to make and store sterile water and IV solutions onboard the spacecraft. If intravenous fluids are to be produced in SSF, successful sterilization of water and reconstituting of IV solutions must be achieved. The second objective is to repeat the verification of the FTS infusion pump, which had been performed in Spacelab Life Sciences - 1 (SLS-1). during SLS-1, the FTS IV pump was operated in continuous microgravity for the first time. The pump functioned successfully, and valuable knowledge on its performance in continuous microgravity was obtained. Finally, the technique of starting an IF in microgravity will be demonstrated. The IV technique requires modifications in microgravity, such as use of restraints for equipment and crew members involved.

Lloyd, Charles W.

Acoustic responses of coupled fluid-structure system by acoustic-structural analogy

The use of an analogy between structural mechanics and acoustics makes it possible to solve fluid-structural interaction (FSI) problems using an existing structural analysis computer program. This method was implemented in MSC/NASTRAN program and the FSI analysis was performed using two dimensional coupled fluid beam model to assess and evaluate the adequacy of this approach. The coupled modal analysis of 3-D model is also briefly discussed. The normal mode, modal frequency response and transient response analysis of 2-D coupled fluid beam system is presented. The significant reduction of the acoustic pressure response at the fluid structure interface is observed as a result of fluid structure interaction.

Shin, Y. S.

Automatic Mesh Generation of Hybrid Mesh on Valves in Multiple Positions in Feedline Systems

Fluid flow simulations through a valve often require evaluation of the valve in multiple opening positions. A mesh has to be generated for the valve for each position and compounding. The problem is the fact that the valve is typically part of a larger feedline system. In this paper, we propose to develop a system to create meshes for feedline systems with parametrically controlled valve openings. Herein we outline two approaches to generate the meshes for a valve in a feedline system at multiple positions. There are two issues that must be addressed. The first is the creation of the mesh on the valve for multiple positions. The second is the generation of the mesh for the total feedline system including the valve. For generation of the mesh on the valve, we will describe the use of topology matching and mesh generation parameter transfer. For generation of the total feedline system, we will describe two solutions that we have implemented. In both cases the valve is treated as a component in the feedline system. In the first method the geometry of the valve in the feedline system is replaced with a valve at a different opening position. Geometry is created to connect the valve to the feedline system. Then topology for the valve is created and the portion of the topology for the valve is topology matched to the standard valve in a different position. The mesh generation parameters are transferred and then the volume mesh for the whole feedline system is generated. The second method enables the user to generate the volume mesh on the valve in multiple open positions external to the feedline system, to insert it into the volume mesh of the feedline system, and to reduce the amount of computer time required for mesh generation because only two small volume meshes connecting the valve to the feedline mesh need to be updated.

Ross, Douglass H.

Aseptic fluid-transfer system

Inexpensive storage and transfer system allows blood and other fluids to be added or removed without contamination. Device heat-sterilizes external surfaces of terminals and forms sterile passageway between terminals.

Arnett, J. C.

Organic Compounds in Early Solar System Aqueous Fluids

thermally-metamorphosed ordinary chondrite regolith breccias (Monahans 1998, hereafter simply “Monahans” ( 5) and Zag (H3-6)) contain fluid inclusion-bearing halite (NaCl) crystals dated to be ~4.5 billion years old. Thus, compositional data on fluid inclusions in these halites will reveal unique information regarding the origin and activity of aqueous fluids in the early solar system, and especially their interactions with organic mate- rial. Our initial analyses of solid inclusions in Monahans halite has shown the presence of olivine, high- and low- Ca pyroxene, feldspars, magnetite, sulfides, phyllosilicates, zeolites, metal, phosphates and abundant organics. We age of carbon, carbonates and organics in these residues, and low but significant amino acids concentrations in Monahans and Zag halite.

Bodnar, R. J.

An intelligent data acquisition system for fluid mechanics research

This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.

Cantwell, E. R.

Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system

A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.

Schmidt, Tyler

Fluid thrust control system

A pure fluid thrust control system is described for a pump-fed, regeneratively cooled liquid propellant rocket engine. A proportional fluid amplifier and a bistable fluid amplifier control overshoot in the starting of the engine and take it to a predetermined thrust. An ejector type pump is provided in the line between the liquid hydrogen rocket nozzle heat exchanger and the turbine driving the fuel pump to aid in bringing the fluid at this point back into the regular system when it is not bypassed. The thrust control system is intended to function in environments too severe for mechanical controls.

Howell, W. L.

Flowmeter evaluation for on-orbit operations

Various flowmetering concepts were flow tested to characterize the relative capabilities and limitations for on-orbit fluid-transfer operations. Performance results and basic operating principles of each flowmetering concept tested are summarized, and basic considerations required to select the best flowmeter(s) for fluid system application are discussed. Concepts tested were clamp-on ultrasonic, area averaging ultrasonic, offset ultrasonic, coriolis mass, vortex shedding, universal venturi tube, turbine, bearingless turbine, turbine/turbine differential-pressure hybrid, dragbody, and dragbody/turbine hybrid flowmeters. Fluid system flowmeter selection considerations discussed are flowmeter performance, fluid operating conditions, systems operating environments, flowmeter packaging, flowmeter maintenance, and flowmeter technology. No one flowmetering concept tested was shown to be best for all on-orbit fluid systems.

Baird, R. S.

Applications of a general thermal/hydraulic simulation tool

The analytic techniques, sample applications, and development status of a general-purpose computer program called SINDA '85/FLUINT (for systems improved numerical differencing analyzer, 1985 version with fluid integrator), designed for simulating thermal structures and internal fluid systems, are described, with special attention given to the applications of the fluid system capabilities. The underlying assumptions, methodologies, and modeling capabilities of the system are discussed. Sample applications include component-level and system-level simulations. A system-level analysis of a cryogenic storage system is presented.

Cullimore, B. A.