At least 145 records · Page 8

Dry in-pile fracture test (DRIFT) for separate-effects validation of ceramic fuel fracture models

Fracture is an important component of nuclear fuel behavior, and significant efforts have been invested into developing fuel performance models that are capable of accurately representing fracture. Usable data on the process of fracture propagation in nuclear fuel under realistic service conditions are very limited. To address this need, a series of separate-effects experiments were developed and performed at Idaho National Laboratory's Transient Reactor Test (TREAT) facility. These experiments employ a heat sink to radially remove heat from the fuel in a manner that approximates the effect of coolant in an operating light-water reactor (LWR). The test holder for these experiments is known as the Dry In-pile Fracture Test (DRIFT). A series of experiments employing DRIFT and TREAT were performed to provide data on the extent and nature of fracture in fresh fuel at various points during a ramp to full power. Novel aspects of these experiments include the way they employ a heat sink to replicate steady-state LWR conditions, as well as the use of fiber optic sensors for in-reactor thermal instrumentation. Details on the development of this experiment, experimental conditions, and resulting data (including in situ thermal measurements and post-irradiation imaging of fracture) are provided in this work. LWR-equivalent powers ranging from 10 to 25 kW/m were tested using this apparatus. Cracking was visible at all power levels, with increasing cracking extent as the power level increased, although there was little difference in the cracking between the two highest-power tests, which had LWR-equivalent powers of 20 and 25 kW/m.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic machining of polyurethane foam

Low-density foam can be machined precisely while frozen. Liquid nitrogen cools foam and aluminum heat sink prior to machining. Heat sink keeps part frozen during entire machining operation.

Moshey, E. A.↗

Impact of thermal energy storage properties on solar dynamic space power conversion system mass

A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overalll system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1880 kg/cu m.

Juhasz, Albert J.↗

Impact of thermal energy storage properties on solar dynamic space power conversion system mass

A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overall system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1800 kg/cu m).

Juhasz, Albert J.↗

Diffusion Flame Extinction in a Low Strain Flow

Diffusion flames are of great interest in fire safety and many industrial processes. Many parameters significantly affect the flame structure, shape and stability, of particular importance are the constraints imposed by geometrical boundaries. Physical boundaries determine the characteristics of the flow, affect heat, fuel, and oxidizer transport from and towards the flame and can act as heat sinks or heat sources. As a result, the existence of a flame, its shape and nature are intimately related to the geometrical characteristics of the environment that surrounds it. The counter-flow configuration provides a constant strain flow, therefore, is ideal to study the structure of diffusion flames. Most studies have concentrated on the high velocity, high strain limit, since buoyantly induced instabilities will disintegrate the planar flame as the velocity decreases. Only recently, experimental studies in micro-gravity conditions have begun to explore the low strain regimes. The main objective of these on-going studies is to determine the effect of radiative heat losses and variable strain on the structure and radiation-induced extinction of diffusion flames. For these programs, size, geometry, and experimental conditions have been chosen to keep the flame unaffected by the physical boundaries. Whether is the burning of condensed or gaseous fuels, for most real situations the boundaries impose a significant effect on the nature of the flame. There is, therefore, a need to better understand the effect that geometrical constraints (i.e. flow nonperpendicular to a fuel surface, heat losses to the boundaries, etc.) might have on the final characteristics of a diffusion flame. Preliminary experiments have shown that, in the absence of gravity, and depending on the distance from the flame to the boundary, three characteristically different regimes can be observed. Close to the boundary, the flame is parabolic, very thin and blue, almost soot-less. Diffusion is the main mechanism controlling fuel transport to the reaction zone, conduction towards the inlets is the main source of heat losses. As the distance increases the flame becomes linear and thickens, remaining blue at the oxidizer side and turning yellow at the fuel side. Here, convection brings fuel and oxidizer together and the reaction occurs in the viscous layer formed between the fuel and oxidizer streams. This region corresponds to the characteristic counter-flow flame where conduction and convection become negligible forms of heat losses and radiation becomes dominant. The flame in the third (mixed) region, between the two others, results from the combination of the scenarios presented above.

Sutula, Jason↗

Personal cooling systems: Possibilities and limitations

Personal thermal control by means of gas- or liquid-conditioned garments was developed during the 1960s and has been applied in a variety of aerospace and industrial settings. Both USAF fighter pilots and astronauts are required to wear heavy protective clothing which insulates them from the environment and thus creates stress through storage of metabolic heat. The problem is particularly severe in astronauts who perform heavy physical work during extra-vehicular activity (EVA); without artificial cooling they could reach incapacitating hyperthermia in a matter of minutes. This paper reviews the factors which influence the design of personal cooling systems. An important early step is determination of acceptable heat stress level, taking into account possible interactions of heat stress with other physiological problems such as motion sickness, diminished plasma volume, decompression sickness and acceleration tolerance. Other factors which require consideration include the work schedule, the area to be covered by the cooling garment, and the practicalities of a fixed or body-mounted heat sink and its power source. Nearly every imaginable heat sink has been proposed or tried over the past 30 years, including direct gas systems, phase-change systems with open or closed loops and thermoelectric heat sinks. The latter are now the system of choice for aircraft.

Nunneley, Sarah A.↗

[Redesign of the Spacesuit Long Life Battery and the Personal Life Support System Battery]

This fall I was working on two different projects that culminated into a redesign of the spacesuit LLB (long life battery). I also did some work on the PLSS (personal life support system) battery with EC. My first project was redlining the work instruction for completing DPAs (destructive physical analysis) on battery cells in the department. The purpose of this document is to create a standard process and ensure that the data in the same way no matter who carries out the analysis. I observed three DPAs, conducted one with help, and conducted two on my own all while taking notes on the procedure. These notes were used to write the final work instruction that will become is the department standard. My second project continued the work of the summer co-op before me. I was testing aluminum heat sinks for their ability to provide good thermal conduction and structural support during a thermal runaway event. The heat sinks were designed by the summer intern but there was not much time for testing before he left. We ran tests with a heater on the bottom of a trigger cell to try to drive thermal runaway and ensure that it will not propagate to adjacent cells. We also ran heat-to-vent tests in an oven to see if the assembly provided structural support and prevented sidewall rupture during thermal runaway. These tests were carried out at ESTA (energy systems test area) and are providing very promising results that safe, high performing (greater than 180 Wh/kg) designs are possible. My main project was a redesign of the LLB battery. Another summer intern did some testing and concluded that there was no simple fix to mitigate thermal runaway propagation hazards in the current design. The only option was a clean sheet redesign of the battery. I was given a volume and ideal energy density and the rest of the design was up to me. First, I created new heat sink banks in Creo using the information gathered in the metal heat sink tests from the summer intern. After this, I made capture plates to hold the cells in place and I worked on nickel bussings for the electrical connections between the cells. Finally, I designed the test box enclosure that included sections for flame arresting materials. The battery brick design, which is the heart of the battery, promises to become the first for a manned spacecraft application to achieve greater than 180 Wh/kg. My work in redlining the DPA work instructions will also be used in selecting the cells for the battery. We had a few options of cells that would provide the necessary power output and needed to make a choice. We repeatedly charged and discharged cells for around a month until they went through 100 lifecycles. The plan is to compare the DPA results on fresh and cycled cells from each manufacturer to see if cycling introduces any differences. After the complete LLB design was approved, the parts were ordered and testing should begin the first week of December. Some of my side projects included working on the CAD data for the PLSS with EC and attending the NASA Aerospace Battery Workshop in Huntsville. I was also a member of the Tours and Lectures Committee for the USRA and Pathways interns. I coordinated Apollo Evening and was on the committee for touring KSC and seeing an Atlas 5 launch. I really enjoyed my time at JSC and I would like to continue working for NASA or another aerospace company in the future. I have worked other internships prior to this, but I think the heavy research and development focus is the best fit for me. I originally thought I would need to go to grad school to work in an environment like this, but I now see it is possible with a bachelor’s degree and hard work. I would like to go into the workforce and maybe continue my education with night classes.

Scharf, Stephanie↗

[Fall 2015 Abstract by Stephanie Scharf]

This Fall I worked on two different projects that culminated into a redesign of the spacesuit LLB (long life battery). I also did some work on the PLSS (personal life support system) battery with EC. My first project was redlining the work instruction for completing DPAs (destructive physical analysis) on battery cells in the Branch. The purpose of this document is to create a standard process and ensure that the data is collected in the same way, no matter who carries out the analysis. I observed three DPAs, conducted one with help, and conducted two on my own, all while taking notes on the procedure. These notes were used to write the final work instruction, which will become the Branch standard. My second project continued the work of the Summer co-op before me. I tested aluminum heat sinks for their ability to provide good thermal conduction and structural support during a thermal runaway event. The heat sinks had been designed by the previous Summer co-op, but there was not much time for testing before he left. We thus ran tests with a heater on the bottom of a trigger cell to try to drive thermal runaway and ensure that it will not propagate to adjacent cells. We also ran heat-to-vent tests in an oven to see if the assembly provided structural support and prevented sidewall rupture during thermal runaway. These tests were carried out at ESTA (Energy Systems Test Area) and are providing very promising results, indicating that safe, high performing (>180 Wh/kg) designs are possible. My main project was a redesign of the LLB (Lightweight Lithium Battery). Another summer intern had done some testing and concluded that there was no simple fix to mitigate thermal runaway propagation hazards in the existing design. The only option was a clean sheet redesign of the battery. I was given a volume and ideal energy density, and the rest of the design was up to me. First, I created new heat sink banks in CREO, using the information gathered in the metal heat sink tests from the summer intern. After this, I made capture plates to hold the cells in place, and I worked on nickel bussings for the electrical connections between the cells. Finally, I designed the test box enclosure that included sections for flame arresting materials. The battery brick design, which is the heart of the battery, promises to become the first for a manned spacecraft application to achieve > 180 Wh/kg. My work in redlining the DPA work instructions will also be used in selecting the cells for the battery. We had a few options for cells that would provide the necessary power output and needed to make a choice. We repeatedly charged and discharged cells for around a month until they went through 100 lifecycles. The plan was to compare the DPA results on fresh and cycled cells from each manufacturer to see if cycling introduces any differences. After the complete LLB design was approved, the parts were ordered and testing should begin the first week of December. Cutting open a cell for DPA After photo from oven heat-to-vent test

Scharf, Stephanie↗

Validation of Landsat-7 ETM+ MEM Thermal Improvement in Thermal Vacuum Tests and in Flight Due to Lower Louver Set Points

The Enhanced Thematic Mapper Plus (ETM+) Main Electronics Module (MEM) power supply heat sink temperature is critical to the Landsat-7 mission. It is strongly dependent on the thermal louver design. A lower power supply heat sink temperature increases the reliability of the MEM, and reduces the risk of over heating and thermal shut-down. After the power supply failures in ETM+ instrument thermal vacuum tests #1 and #2, the author performed detailed thermal analyses of the MEM, and proposed to reduce the louver set-points by 7C. At the 1998 Intersociety Energy Conversion Engineering Conference (IECEC), the author presented a paper that included results of thermal analysis of the MEM. It showed that a 70C reduction of the louver set points could reduce the maximum power supply heat sink temperature in thermal vacuum test and in flight to below 20"C in the cooler outgas mode and in the nominal imaging mode, and has no significant impact on the standby heater duty cycle. It also showed that the effect of Earth infrared and albedo on the power supply heat sink temperature is small. The louver set point reduction was implemented in June 1998, just prior to ETM+ thermal vacuum test #3. Results of the thermal vacuum tests, and temperature data in flight validate the MEM thermal performance improvement due to the 70C reduction of the louver set points.

Choi, Michael K.↗

Thermal Buckling Analysis of Rectangular Panels Subjected to Humped Temperature Profile Heating

This research investigates thermal buckling characteristics of rectangular panels subjected to different types of humped temperature profile heating. Minimum potential energy and finite-element methods are used to calculate the panel buckling temperatures. The two methods give fairly close thermal buckling solutions. 'Buckling temperature magnification factor of the first kind, eta' is established for the fixed panel edges to scale up the buckling solution of uniform temperature loading case to give the buckling solution of the humped temperature profile loading cases. Also, 'buckling temperature magnification factor of the second kind, xi' is established for the free panel edges to scale up the buckling solution of humped temperature profile loading cases with unheated boundary heat sinks to give the buckling solutions when the boundary heat sinks are heated up.

Ko, William I.↗

Freeze-Tolerant Condensers

Two condensers designed for use in dissipating heat carried by working fluids feature two-phase, self-adjusting configurations such that their working lengths automatically vary to suit their input power levels and/or heat-sink temperatures. A key advantage of these condensers is that they can function even if the temperatures of their heat sinks fall below the freezing temperatures of their working fluids and the fluids freeze. The condensers can even be restarted from the frozen condition. The top part of the figure depicts the layout of the first condenser. A two-phase (liquid and vapor) condenser/vapor tube is thermally connected to a heat sink typically, a radiatively or convectively cooled metal panel. A single-phase (liquid) condensate-return tube (return artery) is also thermally connected to the heat sink. At intervals along their lengths, the condenser/vapor tube and the return artery are interconnected through porous plugs. This condenser configuration affords tolerance of freezing, variable effective thermal conductance (such that the return temperature remains nearly constant, independently of the ultimate sink temperature), and overall pressure drop smaller than it would be without the porous interconnections. An additional benefit of this configuration is that the condenser can be made to recover from the completely frozen condition either without using heaters, or else with the help of heaters much smaller than would otherwise be needed. The second condenser affords the same advantages and is based on a similar principle, but it has a different configuration that affords improved flow of working fluid, simplified construction, reduced weight, and faster recovery from a frozen condition.

Crowley, Christopher J.↗

High-efficiency V-band GaAs IMPATT diodes

Double-drift GaAs IMPATT diodes were designed for V-band frequency operations and fabricated using molecular-beam epitaxy. The diodes were fabricated in two configurations: (1) circular mesa diodes with silver-plated (integrated) heat sinks: (2) pill-type diodes bonded to diamond heat sinks. Both configurations utilized a miniature quartz-ring package. Output power greater than 1 W CW was achieved at V-band frequencies from diodes on diamond heat sinks. The best conversion efficiency was 13.3 percent at 55.5 GHz with 1 W output power.

Ma, Y. E.↗

Heat flow in variable polarity plasma arc welds

The space shuttle external tank and the space station Freedom are fabricated by the variable polarity plasma arc (VPPA) welding. Heat sink effects (taper) are observed when there are irregularities in the work-piece configuration especially if these irregularities are close to the weld bead. These heat sinks affect the geometry of the weld bead, and in extreme cases they could cause defects such as incomplete fusion. Also, different fixtures seem to have varying heat sink effects. The objective of the previous, present, and consecutive research studies is to investigate the effect of irregularities in the work-piece configuration and fixture differences on the weld bead geometry with the ultimate objective to compensate automatically for the heat sink effects and achieve a perfect weld.

Abdelmessih, Amanie N.↗

Asymmetric configurable double-sided manifold micro-channel cold plates

A cold plate having a manifold includes a recess extending from a first side to a second side of the manifold, where the recess includes openings to the recess positioned lengthwise along the first side and a single opening to the recess on the second side, an inlet and an outlet fluidly coupled to the recess, a plurality of plates fastened to the first side enclosing the openings, a heat sink fastened to the second side enclosing the single opening on the second side, and a plurality of fluid cores one of each positioned between each of the plurality of plates and the heat sink. The plurality of fluid cores include a flow distribution insert, a first plate fin positioned between the flow distribution insert and the heat sink fastened to the second side, and a second plate fin positioned between the flow distribution insert and the heat sink.

Zhou, Feng↗

Carbon-Nanotube-Carpet Heat-Transfer Pads

Microscopic thermal-contact pads that include carpet-like arrays of carbon nanotubes have been invented for dissipating heat generated in integrated circuits and similarly sized single electronic components. The need for these or other innovative thermal-contact pads arises because the requisite high thermal conductances cannot be realized by scaling conventional macroscopic thermal-contact pads down to microscopic sizes. Overcoming limitations of conventional thermal-contact materials and components, the carbon-nanotube thermal-contact pads offer the high thermal conductivities needed to accommodate the high local thermal power densities of modern electronic circuits, without need for large clamping pressures, extreme smoothness of surfaces in contact, or gap-filling materials (e.g., thermally conductive greases) to ensure adequate thermal contact. Moreover, unlike some conventional thermal-contact components, these pads are reusable. The figure depicts a typical pad according to the invention, in contact with a rough surface on an electronic component that is to be cooled. Through reversible bending and buckling of carbon nanotubes at asperities on the rough surface, the pad yields sufficiently, under relatively low contact pressure, that thermal contact is distributed to many locations on the surface to be cooled, including valleys where contact would not ordinarily occur in conventional clamping of rigid surfaces. Hence, the effective thermal-contact area is greater than that achievable through scaling down of a macroscopic thermal-contact pad. The extremely high longitudinal thermal conductivities of the carbon nanotubes are utilized to conduct heat away from potential hot spots on the surface to be cooled. The fibers protrude from a layer of a filler material (Cu, Ag, Au, or metal-particle- filled gels), which provides both mechanical support to maintain the carbon nanotubes in alignment and thermal conductivity to enhance the diffusion of concentrated heat from the nanotubes into the larger adjacent volume of a heat sink. The array of carbon nanotubes, the filler material, and the heat sink are parts of a unitary composite structure that is fabricated as follows: 1. Using techniques that have been reported previously, the array of substantially perpendicularly oriented carbon nanotubes is grown on a metal, silicon, or other suitable thermally conductive substrate that is intended to become the heat sink. 2. By means of chemical vapor deposition, physical vapor deposition, plasma deposition, ion sputtering, electrochemical deposition, or casting from a liquid phase, some or all of the interstitial volume between carbon nanotubes is filled with the aforementioned layer of mechanically supporting, thermally conductive material. 3. To cause the carbon nanotubes to protrude the desired length from the filler material, an outer layer of filler is removed by mechanical polishing, chemical mechanical polishing, wet chemical etching, electrochemical etching, or dry plasma etching.

Li, Jun↗

Analysis and Optimization of a Multi-Layer Integrated Organic Substrate for High Current GaN HEMT-Based Power Module

In this paper, analysis and optimization of a multi-layer organic substrate for high current GaN HEMT based power module are discussed. The organic multi-layer substrates can provide high electrical performance in terms of low parasitic inductance in the power loop by providing vertical layout, and shielding for reduction of common-mode noise, a common problem in fast switching power converters. Furthermore, high performance cooling solutions, such as micro-channel heat sinks, can be directly bonded to the substrate for optimum thermal management. The structure of the proposed architecture, thermal analysis and optimization of layer thickness, thermo-mechanical stress analysis of the GaN HEMT and development of a high-performance heat sink are discussed.