Search NASA⌕ Search

SEARCH · Search NASA

Results for “High contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

In Situ Studies of Methanol Decomposition Over Cu(111) and Cu2O/Cu(111): Effects of Reactant Pressure, Surface Morphology, and Hot Spots of Active Sites

The dissociative adsorption of methanol was investigated on Cu(111) and ultrathin Cu 2 O films. We employed synchrotron-based Ambient Pressure X-ray Photoelectron Spectroscopy (AP-XPS) and Scanning Tunneling Microscopy (STM) to study the dynamics of gas–solid interactions, and calculations based on Density Functional Theory (DFT) were used to examine the reaction path. C 1s XPS spectra revealed that methanol underwent dissociative adsorption on plain Cu(111) to form methoxy (CH 3 O), formaldehyde (H 2 CO), and formate (HCOO) at a pressure range of 0.5–10 mTorr, with these species remaining on the surface after evacuation. This was accompanied by the appearance of a low coverage (~0.05 ML) of O ads in the O 1s which can be considered a highly active site for methanol activation. The high activity is apparent by a coverage of 0.8 ML of methoxy at room temperature. STM was unable to image these species at room temperature as they were highly mobile on metallic copper. In contrast, for CH 3 OH on Cu 2 O/Cu(111), STM showed clear hot spots for reaction and a complex array of adsorption structures. On the oxide substrate, there was decomposition of methanol to H 2 CO, CH 3 O, HCOO, and hydrocarbon species (CH x ) due to the subsequent interactions of methanol with lattice oxygen. Cu(111) remained entirely saturated with decomposition products under 10 mTorr of methanol (θ ≈ 0.97 ML), whereas the Cu 2 O overlayer was saturated at a much lower coverage (θ ≈ 0.30 ML). STM revealed rows and step edges of Cu 2 O decorated with decomposition products and metallic Cu islands ~5 nm in size. The difference in activity between Cu(111) and Cu 2 O/Cu(111) is attributed to the significant amount of O present on the oxide surface. Additionally, Density Functional theory (DFT) calculations described the XPS measurements well, showing a likely methanol dissociation to *CH 3 O and therefore a surface reduction. More importantly, the DFT results revealed that it was the chemisorbed oxygen on Cu 2 O/Cu(111) which oxidized the dissociated *CH 3 O to *HCOO and eventually CO 2 , while the reaction only involving upper oxygen on the Cu 2 O hexagonal ring led to the formation of H 2 CO.

36 MATERIALS SCIENCE↗

Recent advances and applications of deep learning methods in materials science

Deep learning (DL) is one of the fastest-growing topics in materials data science, with rapidly emerging applications spanning atomistic, image-based, spectral, and textual data modalities. DL allows analysis of unstructured data and automated identification of features. The recent development of large materials databases has fueled the application of DL methods in atomistic prediction in particular. In contrast, advances in image and spectral data have largely leveraged synthetic data enabled by high-quality forward models as well as by generative unsupervised DL methods. In this article, we present a high-level overview of deep learning methods followed by a detailed discussion of recent developments of deep learning in atomistic simulation, materials imaging, spectral analysis, and natural language processing. For each modality we discuss applications involving both theoretical and experimental data, typical modeling approaches with their strengths and limitations, and relevant publicly available software and datasets. We conclude the review with a discussion of recent cross-cutting work related to uncertainty quantification in this field and a brief perspective on limitations, challenges, and potential growth areas for DL methods in materials science.

36 MATERIALS SCIENCE↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray and Neutron Radiography for Quantitative Material Reconstructions

Radiography is a powerful tool to determine the interior structure of objects. X-ray radiography is widely used and provides high-resolution images, though X-rays have limited transmission through materials of high atomic number (Z) and density. In contrast, neutrons can penetrate many materials that are heavily attenuating to X-rays, such as metals, providing contrast in the inner layers of highly attenuating items. Past work has shown the value in using both X-ray and neutron radiography for estimating material thicknesses, though that work was limited to simulated data. Here, we demonstrate quantitative material reconstructions using experimental X-ray and neutron radiography data from lab-based systems, accurately modeling radiography system responses to within a few percent to enable quantitative measures of material thickness. We demonstrate the utility of neutron radiography and X-ray radiography for these quantitative reconstructions and introduce methods for using their complementarity to improve image quality and optimize experimental design.

Gilbert, Andrew J.↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Multimodal microscopy of extended defects in β-Ga 2 O 3 (010) EFG crystals

Beta-phase gallium oxide (β-Ga 2 O 3 ) has attracted attention in recent years as a potentially low cost, large area substrate and active layer material for high power, high temperature power electronics and sensing devices. However, growth of β-Ga 2 O 3 crystals is complicated by easily activated (100) and (001) cleavage planes, the presence of low angle grain boundaries (LAGBs) and twins, and the potential formation of polycrystalline grains. In this study, β-Ga 2 O 3 crystals were grown by the edge-defined film-fed growth technique with an (010) principal face. Two crystals with apparently randomly formed high angle grain boundaries (HAGBs) were selected and analyzed by electron backscatter diffraction, electron channeling contrast imaging, and cathodoluminescence to investigate the nature of the LAGBs and the source of the HAGB formation. It was discovered that planar LAGBs lying parallel to the (010) plane exist in the region immediately preceding the start of an HAGB. Increased misorientation across the LAGB was observed, approaching the initiation of a new grain. We present multimodal microscopy characterization, correlating misorientation and variation in optoelectronic properties with LAGBs and the associated dislocations.

14 SOLAR ENERGY↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination

To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing three-dimensional mesoscopic interfacial structures in a single view using multibeam X-ray coherent surface scattering and holography imaging

Abstract Visualizing surface-supported and buried planar mesoscale structures, such as nanoelectronics, ultrathin-film quantum dots, photovoltaics, and heterogeneous catalysts, often requires high-resolution X-ray imaging and scattering. Here, we discovered that multibeam scattering in grazing-incident reflection geometry is sensitive to three-dimensional (3D) structures in a single view, which is difficult in conventional scattering or imaging approaches. We developed a 3D finite-element-based multibeam-scattering analysis to decode the heterogeneous electric-field distribution and to faithfully reproduce the complex scattering and surface features. This approach further leads to the demonstration of hard-X-ray Lloyd’s mirror interference of scattering waves, resembling dark-field, high-contrast surface holography under the grazing-angle scattering conditions. A first-principles calculation of the single-view holographic images resolves the surface patterns’ 3D morphology with nanometer resolutions, which is critical for ultrafine nanocircuit metrology. The holographic method and simulations pave the way for single-shot structural characterization for visualizing irreversible and morphology-transforming physical and chemical processes in situ or operando .

47 OTHER INSTRUMENTATION↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

Infrared quantum ghost imaging of living and undisturbed plants

Quantum ghost imaging (QGI) is a method that measures absorption at extremely low light intensities. Nondegenerate QGI probes a sample at one wavelength while forming an image with correlated photons at a different wavelength. This spectral separation alleviates the need for imaging detectors with high sensitivity in the near-infrared (NIR) region, thereby reducing the required illumination intensity. Using NCam, a single-photon detector, we demonstrated nondegenerate QGI with unprecedented sensitivity and contrast, obtaining images of living plants with less than 1% light transmission. The plants experienced 3aW/cm 2 of light during imaging, orders of magnitude below starlight. This realization of QGI expands the method to extremely low-light bioimaging and imaging of light-sensitive samples, where minimizing illumination intensity is crucial to prevent phototoxicity or sample degradation.

47 OTHER INSTRUMENTATION↗

Experimental investigation of internal two-phase flow structures and dynamics of quasi-stable sheet cavitation by fast synchrotron x-ray imaging

The quasi-stable sheet cavitation produced in a small Venturi channel is investigated using a fast synchrotron X-ray imaging technique aided with conventional high speed photography. The use of X-rays instead of visible light solves cavitation opacity related issues, and X-ray phase contrast-based edge enhancement enables high-definition visualization of the internal two-phase morphology. The simultaneous acquisition of time-resolved velocity and void fraction fields through post-processing the recorded X-ray images reveals, for the first time, the complex diphasic flow structures inside the sheet cavity, which is essentially divided into 6 characteristic parts. Distinct from the current mainstream view, the globallysteady sheet cavitation is found to be characterized by a weak but constantly-existing re-entrant flow that can penetrate the entire cavity. The turbulent velocity fluctuations inside the sheet cavity are also investigated. The turbulence level in the reverse flow region is observed to be as low as in the outer main flow demonstrating the relatively steady status of the reentrant flow. Unlike the streamwise and cross-stream fluctuations, the shear stress appears to be weakly correlated with the velocity gradient. The collapse of vapor phase and the vaporization at the upstream cavity interface are found to be the primary causes of shear stress intensification.

42 ENGINEERING↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Phase imaging of irradiated foils at the OMEGA EP facility using phase-stepping X-ray Talbot–Lau deflectometry

Abstract Diagnosing the evolution of laser-generated high energy density (HED) systems is fundamental to develop a correct understanding of the behavior of matter under extreme conditions. Talbot–Lau interferometry constitutes a promising tool, since it permits simultaneous single-shot X-ray radiography and phase-contrast imaging of dense plasmas. We present the results of an experiment at OMEGA EP that aims to probe the ablation front of a laser-irradiated foil using a Talbot–Lau X-ray interferometer. A polystyrene (CH) foil was irradiated by a laser of 133 J, 1 ns and probed with 8 keV laser-produced backlighter radiation from Cu foils driven by a short-pulse laser (153 J, 11 ps). The ablation front interferograms were processed in combination with a set of reference images obtained ex situ using phase-stepping. We managed to obtain attenuation and phase-shift images of a laser-irradiated foil for electron densities above ${10}^{22}\;{\mathrm{cm}}^{-3}$ . These results showcase the capabilities of Talbot–Lau X-ray diagnostic methods to diagnose HED laser-generated plasmas through high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗