Search NASA⌕ Search

SEARCH · Search NASA

Results for “Initial Transmission Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Formation and surface melting of nanoparticle superlattices in a solution

The wisdom in the saying of “There are no two snowflakes alike” lies in the importance of history or kinetic pathways in the phase transitions of solids. Likewise, “artificial solids,” namely superlattices consisting of functional nanoparticles, have lattice size, surface morphology, crystallinity, symmetry, and structural reconfiguration (for example, transition into a disordered state) highly dependent on the kinetic pathways as the nanoparticles interact with each other in solution [1]. Great progresses have been made in understanding the formation pathways of superlattices using liquid-phase transmission electron microscopy (TEM) [2-4]. For example, by tracking single nanoparticle’s trajectories, especially aided by U-net neural network-based machine learning, previous studies mapped the fundamental nanoparticle interactions at nanometer resolution [5]. Nonclassical, two-step nucleation pathway has also been elucidated in the system of nanoprisms, by optimizing protocols such as loading nanoparticle suspensions over the supersaturation threshold and minimizing particle‒substrate interaction [2]. Surface morphologies or exposed facets of superlattices have been shown to follow the principles of Wulff construction rule, where the facet-dependent surface energy can be measured based on the capillary wave theory [4]. However, the reverse process of crystallization of superlattices, the conversion from crystalline to disordered state, has been much less explored. On one hand, the melting of nanoparticle superlattices can provide a preferred pathway to induce structural reorganization or shuffling of building blocks for them to transform into different types of crystal structures. On the other hand, understanding nanoscale superlattice melting and comparing such behaviors with the prevailing surface melting theories developed for atomic/molecular solids can provide a potent way to engineer phase transitions of supra- and hierarchical structures constructed from nanoscale entities (e.g., DNA-coated nanoparticles, proteins), for their applications in reprogrammable and switchable materials with multifunctional properties [6, 7]. The experimental challenges to observe melting of superlattices are twofold. Practically it is difficult to load the initial superlattice form, in an intact manner, into the highly confined liquid-phase TEM chamber for in-situ observation. Here, the triggering of melting also needs meticulous manipulation of nanoparticle concentration, interparticle interaction, and solution environment.

Kim, Ahyoung↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coalescence of GaP on V-Groove Si

In recent years, better understanding and control over the formation of crystalline defects during the direct epitaxy of III-V semiconductors on Si substrates via metal organic vapor phase epitaxy (MOVPE) has enabled large gains in III-V-on-Si solar cell efficiency, pointing to pathway to lower-cost, high-performance III-V solar cells. However, such results have only been achieved on costly chemo-mechanically-polished (CMP) Si wafers. The use of V-groove nanopatterned Si substrates has demonstrated similarly high-crystalline-quality III-V-on-Si epitaxy, but also can be combined with lower-cost polishing techniques. Although they offer a potential cost advantage, growth on V-groove substrates adds challenges not present for epitaxy on planar wafers (the III-V material must be coalesced into a thin film after an initial nucleation stage). MOVPE growth conditions that promote highly facet-selective lateral growth needed for coalescence are generally actively avoided for conventional thin fim growth, so growth conditions need to be re-developed for V-groove-based epitaxy. Additionally, coalescence add complexity to the dislocation dynamics related to lattice relaxation, so strategies used to keep threading dislocation density (TDD) low on planar substrates need to be re-tuned for V-grooves. We have studied the morphological evolution and dislocation dynamics of GaP grown on V-groove Si by MOVPE. Growth conditions of V/III=5,000 and Tg=800 degrees C were uniquely found to produce extremely smooth coalesced thin films, with an RMS roughness of 0.2 nm measured by AFM. Additionally, at this growth condition, we identified two regimes of growth determined by the width of the SiNx cap (a remnant of the nanopatterning process) at the top of the V-grooves. For narrow caps, the GaP coalesces into a thin film, and for wide caps, the GaP evolves into {1 1 1}-faceted diamonds that do not coalesce. We suggest the influence of Si from the sidewalls of the V-grooves on the surface reconstruction of the GaP as the mechanism for this effect, with reflection difference spectroscopy (RDS) and Si doping experiments supporting this theory. In addition to morphology, the dislocation dynamics of the system were studied with electron channeling contrast imaging (ECCI) and transmission electron microscopy (TEM). The TDD of the coalesced GaP films was found to be 5 x 10^7 cm^-2 after coalescence via ECCI, a level still too high for high-quality solar cells. However, misfit dislocations crossing multiple grooves greater than 20 micrometers long were observed in ECCI, suggesting that the V-grooves do not block dislocation glide. TEM prior to and after coalescence was used to distinguish between dislocation creation driven by growth conditions and coalescence. Finally, strategies to reduce the dislocation density to levels acceptable for solar cells will be discussed.

GaP↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Melting of charge density waves in low dimensions

Charge density waves (CDWs) are collective electronic states that can reshape and melt, even while confined within a rigid atomic crystal. In two dimensions, melting is predicted to be distinct, proceeding through partially ordered nematic and hexatic states that are neither liquid nor crystal. Here, we measure and explain how continuous, hexatic melting of incommensurate CDWs occurs in low-dimensional materials. As a CDW is thermally excited, disorder emerges progressively—initially through smooth elastic deformations that modulate the local wavelength and subsequently via the nucleation of topological defects. Experimentally, we track three hallmark signatures of CDW melting—azimuthal superlattice peak broadening, wavevector contraction, and integrated intensity decay.

42 ENGINEERING↗

Hot Carrier Redistribution, Electron-Phonon Interaction, and Their Role in Carrier Relaxation in Thin Film Metal-Halide Perovskites

Temperature dependent (4–295 K) photoluminescence and transmission spectra are analyzed to study the effect of changing the different components of a perovskite compound, be it A, B, or X. Four different films are compared: FAMAPbSnI3, FAPbI3, FAMAPbI3, and FAPbBr3. The low temperature results highlight the changes that occur, especially underlying ones that are easily masked at room temperature. The overall Stokes shift is of similar magnitude at room temperature for the three Pb only based samples. This is governed by the interaction strength GLO, phonon energy ELO, and exciton binding energy Eex. One exception to this behavior is the Sn based FAMAPbSnI3 film, which shows a lack of Stokes shift between the absorption and photoluminescence. However, the strong absorption (more than 100 meV) below the band gap is indicative of an excitonic feature that has a large density of states. Transient absorption measurements confirm the trends observed in continuous wave (CW) measurements; the three Pb only films all show the convolution of an excitonic feature within 20 meV of the band gap as a contributing factor to the photobleach along with a region of high energy photoinduced absorption (PIA). However, the behavior for the Sn based film is notably different (just as it is in the CW measurements) with an unusual low energy PIA and a lack of high energy PIA. The large unusual low energy PIA is attributed to the large sub-band-gap absorption observed in the CW transmission/absorption measurements. Notably, regardless of interchanging components, the slow cooling of carriers in metal-halide perovskites shows little effect of GLO, ELO, and Eex. As such, here it is proposed that while the initial cooling of carriers is attributed to LO phonons, the overall cooling of carriers is dominated by the intrinsic low thermal conductivity of all metal-halide perovskites, which limits the dissipation of acoustic phonons in these systems

2D perovskites↗

Constraining the destruction rate of K 40 in stellar nucleosynthesis through the study of the Ar 40 ( p , n ) K 40 reaction

Background: We present that K 40 plays a significant role in the radiogenic heating of Earth-like exoplanets, which can affect the development of a habitable environment on their surfaces. The initial amount of K 40 in the interior of these planets depends on the composition of the interstellar clouds from which they formed. Within this context, nuclear reactions that regulate the production of K 40 during stellar evolution can play a critical role. Purpose: In this study, we constrain for the first time the astrophysical reaction rate of K 40 ( n , p ) Ar 40 , which is responsible for the destruction of K 40 during stellar nucleosynthesis. We provide to the nuclear physics community high-resolution data on the cross section and angular distribution of the Ar 40 ( p , n ) K 40 reaction. These are important to various applications involving Ar 40 . The associated reaction rate of the Ar 40 ( p , n ) K 40 process addresses a reaction rate gap in the Joint Institute for Nuclear Astrophysics REACLIB database in the region of intermediate-mass isotopes. Methods: We performed differential cross-section measurements on the Ar 40 ( p , n ) K 40 reaction, for six energies in the center-of-mass system between 3.2 and 4.0 MeV and various angles between 0 ° and 135 ° . The experiment took place at the Edwards Accelerator Laboratory at Ohio University using the beam swinger target location and a standard neutron time-of-flight technique. We extracted total and partial cross sections by integrating the double differential cross sections we measured. Results: The total and partial cross sections varied with energy due to the contribution from isobaric analog states and Ericson type fluctuations. The energy-averaged neutron angular distributions were symmetrical relative to 90 ° . Based on the experimental data, local transmission coefficients were extracted and were used to calculate the astrophysical reaction rates of Ar 40 ( p , n ) K 40 and K 40 ( n , p ) Ar 40 reactions. The new rates were found to vary significantly from the theoretical rates in the REACLIB library. We implemented the new rates in network calculations to study nucleosynthesis via the slow neutron capture process, and we found that the produced abundance of K 40 is reduced by up to 10% compared to calculations with the library rates. At the same time, the above result removes a significant portion of the previous theoretical uncertainty on the K 40 yields from stellar evolution calculations. Conclusions: Our results support a destruction rate of K 40 in massive stars via the K 40 ( n , p ) Ar 40 reaction that is larger compared to previous estimates. The rate of K 40 destruction via the K 40 ( n , p ) Ar 40 reaction now has a dramatically reduced uncertainty based on our measurement. Lastly, this result directly affects the predicted stellar yields of K 40 from nucleosynthesis, which is a critical input parameter for the galactic chemical evolution models that are currently employed for the study of significant properties of exoplanets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gridtrust: Electricity Grid Root-of-Trust Decentralized Supply Chain Cyber-Security (Final Scientific/Technical Report)

GridTrust represents a departure from reliance on a single organization or a single person to multiple organizations and therefore multiple people across organizational structures. The motivating idea behind involving multiple organizations is the increase in security due to human factors. More specifically, the requirement that distinct people in different organizations sign off on a change or an update makes a cyberattack much less likely due to the inherent requirement that both organizations be penetrated and fooled. GridTrust focuses on the software update process as the primary exemplar for the research and development work. A novel hardware-based technology referred to as a Physical Unclonable Function (PUF) provides a microchip Root-of-Trust (RoT), i.e., a starting point for verifying that the hardware being communicated with is the hardware the control center believes the hardware to be. As a result, staff at power grid control centers can ensure the accurate and reliable identification of hardware devices from the outset. The GridTrust protocol introduces two key innovations, as detailed in this report. Firstly, the utilization of a PUF as a root-of-trust in the initial phase of a software or firmware update. Secondly, the application of multiple cryptographic signatures from two or more organizations to the update binary. These signatures are verified before implementing the update on a power grid device in the field. In terms of GridTrust hardware design, this report outlines two main components. The first is the GridTrust Native Device, integrating PUF technology intrinsically into the hardware device itself. The second is the GridTrust Interfacing Device, which incorporates PUF technology and multiple cryptographic signatures. These signatures are cross-checked within a separate hardware positioned between the power grid control center and the legacy power grid device, functioning as an intermediary. While the GridTrust Interfacing Device offers the advantage of being applicable to existing power grid equipment, it may have reduced security if the intermediary component is targeted. On the other hand, the GridTrust Native Device boasts increased security due to protocol integration within a unified form factor. The effectiveness of GridTrust technology has been extensively demonstrated, with multiple external red-team attackers unable to breach GridTrust's security measures. This was observed both in controlled laboratory settings during Phase 1 of the project and in real-world conditions within a City of Marietta substation during Phase 2 of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability

In fall 2019, the National Association of Regulatory Utility Commissioners (NARUC) and the National Association of State Energy Officials (NASEO) initiated a joint Microgrids State Working Group (MSWG), funded by the U.S. Department of Energy (DOE) Office of Electricity (OE). The MSWG aims to bring together NARUC and NASEO members to explore the capabilities, costs, and benefits of microgrids; discuss barriers to microgrid development; and develop strategies to plan, finance, and deploy microgrids to improve resilience. This report, Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability, focuses specifically on how clean energy microgrids can achieve both resilience and clean energy benefits. The paper provides an overview of the challenges faced by clean energy microgrids, outlines benefits that clean energy microgrids can provide, and details economic and cost considerations for the development of clean energy microgrid projects. Outlined in the paper are the necessary technological components of a clean energy microgrid, including generation, storage, energy efficiency measures, and smart controls. Current technologies are highlighted, along with potential configurations of clean technologies that are approaching cost competitiveness with commercially available options. The paper concludes with both policy and regulatory considerations for State Energy Offices and Public Utility Commissions to enhance the development and deployment of clean energy microgrids. Although it touches on the clean energy microgrids’ role in integrating distributed energy resources (DERs) into the larger grid, this is not the focus of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Imaging Nanoscale Energy Transport and Conversion with Ultrafast Electron Microscopy (Final Technical Report)

Light-matter interactions are ubiquitous in nature and reside at the heart of innumerable technologies. The cascade of processes that occur when a material absorbs a photon of light are exceedingly complex and are interwoven in both space and time, rendering precise determination of the atomic-scale and ultrafast mechanisms immensely challenging. The advent of methods for generating short pulses of light several decades ago led to major advances in understanding the initial moments of light absorption and the resultant effects, though directly interrogating the response of the atoms within the material continued to prove challenging. More recently, methods for generating ultrashort pulses of X-rays and fast electrons have opened the way to probing photoinduced structural dynamics of a wide range of matter in multiple phases. An especially promising laboratory-scale method is ultrafast electron microscopy (UEM), wherein the modalities of conventional transmission electron microscopes (imaging, diffraction, spectroscopy) are extended into the femtosecond temporal regime. Here, the ultrafast imaging and diffraction modalities of UEM were used to study the transient structural aspects of photoexcitation of semiconducting materials (e.g., spatially-resolved electron-phonon coupling, excitation and emission of acoustic phonons, and discrete nanoscale scattering processes). The project had three main objectives: (1) determination of the excitation mechanisms of dense, hypersonic charge-carrier waves and the spatially mediated means by which they couple to the lattice via coherent phonon emission, especially with UEM imaging, wherein effects of nanoscale structural and morphological features on the coupling and relaxation dynamics are expected to dictate nucleation sites and preferred wave vectors, (2) elucidation of photoinduced acoustic-phonon seeding, emergence, propagation, and decay over nanoscale crystal regions and especially with respect to local strain fields and atomic-scale disruptions in lattice order, and (3) interwoven with the first two were efforts aimed at realizing combined angstrom-femtosecond spatiotemporal imaging with UEM. The outcomes and impacts of this project were the generation of new knowledge with respect to fundamental light-matter interactions and, especially, the spatially-mediated excitation and evolution of the structural response of materials following coherent photoexcitation. Importantly, the spatial and temporal resolutions of the UEM imaging modalities used are well-suited for such studies and enable spatially-resolved mechanisms to be determined as a function of atomic order, structural features, and morphology. In addition, ultrafast crystallographic measurements were used to correlate real- and reciprocal-space dynamics in order to determine atomic-scale preferential wave vectors and ultrafast scattering mechanisms, especially as dictated by specimen boundary conditions. The obtained results, as detailed in peer-reviewed publications and presentations, illustrate the importance of ultrafast, angstrom-scale real-space imaging for developing a comprehensive understanding of energy transport and conversion in materials.

47 OTHER INSTRUMENTATION↗

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Final Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. The rapid large-scale deployment of inverter-based resources (IBRs) vital to achieving the nation’s clean energy goals has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated the PROGRESS MATRIX project to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses the outcomes of the project, which was a joint effort between the Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL). In the project’s first year, PNNL, NREL, and ORNL partnered with the Bonneville Power Administration (BPA), the Western Area Power Administration (WAPA), and Kauai Island Utility Cooperative (KIUC) to understand their existing measurement capabilities and the gaps limiting deployment of IBR-focused measurement systems and analytics. The other primary activity in the first year was deployment of GridSweep instruments, which provide unprecedented precision in waveform measurement while probing distribution systems. The instruments were deployed at Dominion Energy and the University of California, Riverside. In the project’s second year, the input from partner utilities and collected measurements were used to advance measurement capabilities. Twelve analytical methods spanning disturbance analysis, power plant evaluation, feeder evaluation, and modeling were developed. Two software tools were developed, one to analyze GridSweep measurements and another to automatically evaluate the control performance of power plants connected to the BPS. Testbeds at ORNL and NREL were augmented to better enable studies of IBR integration. The project culminated in demonstrations of these analytical methods, software tools, and testbeds, both in the field and in the laboratory. This report discusses these various accomplishments and documents the significant progress in developing advanced measurement capabilities to support the secure, reliable, and accelerated adoption of IBRs in the BPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing the Modern Grid: Federal Investments, Digitization, and Supply Chain Strategy

Across the United States (U.S.) grid expansion and modernization is underway, paving the way for accelerated load growth and intelligent resource management. Digitization of the grid is supported by several state and federal programs, providing support for utilities installing advanced metering infrastructure (AMI), AI-powered analytics systems, battery energy storage systems (BESS), and distributed energy resource management systems (DERMS) to transform the grid from a one-way power delivery system into an intelligent, responsive network that will enable faster load growth and power expansion of data centers for advanced artificial intelligence (AI) applications. The digital transformation of America's grid presents opportunity for increased efficiency and resiliency but also introduces new digital risks that require careful management. Digital equipment often contains several vulnerabilities such as unencrypted communication protocols, and persistent remote access capabilities that could be exploited to manipulate device settings, coordinate service disruptions, or inject false data into grid operations. These digital risks become particularly important as the grid must rapidly scale to support AI-driven data centers, which the administration has identified as essential for maintaining U.S. technological leadership and economic competitiveness. These vulnerabilities are compounded by supply chain realities: Chinese manufacturers currently produce 70-90% of essential grid components including inverters, batteries, and control systems, with the U.S. lacking domestic manufacturing capacity for critical assets like extra-high voltage transformers. Recent federal legislation has established Foreign Entity of Concern (FEOC) restrictions to address these risks, requiring projects to achieve escalating thresholds of non-FEOC content to receive tax credits while utilities work to expand sourcing channels for their supply chains and strengthen security measures. These restrictions arrive precisely when utilities face unprecedented electricity demand growth driven by the rapid growth in data centers, creating a considerable challenge: rapidly expanding infrastructure while navigating complex compliance requirements while lacking viable alternatives for many critical components. Idaho National Laboratory (INL) and its partners have developed practical approaches to help utilities navigate these intersecting challenges as they leverage federal investment to strengthen and grow the grid. These solutions include Cyber-Informed Engineering (CIE) principles that build resilience directly into systems, the Cirrus tool for secure cloud migration, and enhanced procurement guidance that embeds security requirements throughout equipment lifecycles. Federal initiatives, such as the Technical Assistance for Digital Assurance (TADA) project, provide direct support to utilities implementing these approaches while facilitating knowledge sharing across the industry. While these tools and frameworks cannot eliminate all risks inherent in foreign supply chain dependencies, they offer pragmatic pathways for strengthening security posture without sacrificing the deployment momentum essential to meeting surging electricity demand. Ultimately, securing America's digital energy infrastructure demands dedicated coordination across multiple fronts: building domestic supply chains, implementing robust digital assurance practices, and maintaining the aggressive modernization timeline necessary for reliability, resilience, and energy independence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating Resilience of the Community through Holistic Engagement and use of Renewables (ARCHER) Planning Framework

The primary objective of the Accelerating Resilience of the Community through Holistic Engagement and Use of Renewables (ARCHER) initiative was to identify and incorporate the unique variations in energy burden, social vulnerability, living conditions, and access to essential services that differ across communities. By accounting for these localized factors—down to the neighborhood level—the project supports more targeted and effective investments in community resilience. The framework seeks to establish practical planning guidance, methods, and performance measures for community energy resilience, integrate community-level and electric utility system resilience planning, and assess its effectiveness through comparison with conventional and operational planning approaches. A key component of the project was its data exchange platform, which is used to evaluate and demonstrate the tools, methodologies, and planning approaches developed through ARCHER. This open-source platform enables developers and vendors of distribution and outage management systems to build upon the research by incorporating its concepts into their own tools and workflows. This capability is enabled by the transparent availability of data, functional requirements, and the underlying information model. The project yielded several important insights. First, meaningful engagement with communities is essential to achieving comprehensive resilience outcomes. Second, resilience planning is most effective when electric grid considerations and broader community needs are addressed in a coordinated manner. Third, the use of platforms that allow for real-time input from communities can enhance utility responsiveness during restoration activities. Fourth, a structured and systematic planning approach can successfully translate ARCHER concepts into practice. Fifth, the development of an integrated metric that reflects both grid performance and community impacts provides a more holistic basis for evaluating resilience. Finally, incorporating community engagement and equity considerations into grid operations is critical, particularly during severe weather events that result in extended outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗