Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bulk and position-specific isotope geochemistry of natural gases from the Late Cretaceous Eagle Ford Shale, south Texas

Here, a dataset of bulk and position-specific isotope compositions of shale gases from the Late Cretaceous Eagle Ford Shale, south Texas is reported. The chemical and bulk isotopic compositions of the seven samples in this study and those available from the literature show that across the play, produced natural gas from the Eagle Ford Shale preserves a wide range of gas compositions (wetness, ~5 to >90%) and δ 13 C values of C 1 –C 3 . The depth profiles of the isotopic compositions suggest that the western region of the Eagle Ford Shale deposit had experienced as much as 700–800 m of uplift-erosion or gas migration. The timing of and lost-gas fractions by gas expulsion events very likely affected their gas compositions and bulk isotope compositions. Some deep (>3000–3500 m), matured (%Ro > 1.5) gases with heavy δ 13 C(C 1 –C 3 ) values indicate significant loss (>50%) of the early-stage gases. For the position-specific isotope deviations of propane, the ΔC 2-1 values of the five samples show small decrease with well depths, while the ΔH 2-1 values have a general increasing trend. Although some samples fall very close to the equilibrium model trajectories with reasonable calculated temperatures (138–148 °C), the position-specific isotope compositions of propane from the Eagle Ford Shale gases are likely results of thermal cracking of various organic molecules within the source rocks, which have different activation energy for cracking and non-statistical distributions of C/H isotope within them.

58 GEOSCIENCES↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Simultaneous isotopic analysis of fission product Sr, Mo, and Ru in spent nuclear fuel particles by resonance ionization mass spectrometry

Abstract Fission product Sr, Mo, and Ru isotopes in six 10-μm particles of spent fuel from a pressurized water reactor were analyzed by resonance ionization mass spectrometry (RIMS) and evaluated for utility in nuclear material characterization. Previous measurements on these same samples showed widely varying U, Pu, and Am isotopic compositions owing to the samples’ differing irradiation environments within the reactor. This is also seen in Mo and Ru isotopes, which have the added complication of exsolution from the UO 2 fuel matrix. This variability is a hindrance to interpreting data from a collection of particles with incomplete provenance since it is not always possible to assign particles to the same batch of fuel based on isotopic analyses alone. In contrast, the measured 90 Sr/ 88 Sr ratios were indistinguishable across all samples. Strontium isotopic analysis can therefore be used to connect samples with otherwise disparate isotopic compositions, allowing them to be grouped appropriately for interpretation. Strontium isotopic analysis also provides a robust chronometer for determining the time since fuel irradiation. Because of the very high sensitivity of RIMS, only a small fraction of material in each of the 10 μm samples was consumed, leaving the vast majority still available for other analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRIFT: Diffusivity Regulation of Isotopes by nanoconFinementT

Spontaneous isotope fractionation has been reported under nanoconfinement conditions in naturally occurring systems, but the origin of this phenomena is currently unknown. Two existing hypotheses have been proposed, one based on changes in the solvation environment of the isotopes that reduces the non-mass dependent hydrodynamics contribution to diffusion. The other is that isotopes have mass-dependent surface adsorption, varying their total diffusion through nanoconfined channels. To investigate these hypotheses, benchtop experiments, nuclear magnetic resonance (NMR) spectroscopy, and molecule scale modeling were applied. Classical molecular dynamics simulations identified that the Na + and Cl - hydration shells across the three different salt solutions ( 22 Na 35 Cl, 23 Na 35 Cl, 24 Na 35 Cl) did not vary as a function of the Na + isotope, but that there was a significant pore size effect, with larger hydration shells at larger pore sizes. Additionally, while total adsorption times did not vary as a function of the Na + isotope or pore size, the free ion concentration, or those adsorbed on the surface for <5% of the simulation time did exhibit isotope dependence. Experimentally, challenges occurred developing a repeatable experiment, but NMR characterization of water diffusion rates through ordered alumina membranes was able to identify the existence of two distinct water environments associated with water inside and outside the pore. Further NMR studies could be used to confirm variation in hydration shells and diffusion rates of dissolved ions in water. Ultimately, mass-dependence adsorption is a primary driver of variations in isotope diffusion rates, rather than variation in hydration shells that occur under nanoconfinement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Deuterated water as a substrate-agnostic isotope tracer for investigating reversibility and thermodynamics of reactions in central carbon metabolism

Stable isotope tracers are a powerful tool for the quantitative analysis of microbial metabolism, enabling pathway elucidation, metabolic flux quantification, and assessment of reaction and pathway thermodynamics. 13 C and 2 H metabolic flux analysis commonly relies on isotopically labeled carbon substrates, such as glucose. However, the use of 2 H-labeled nutrient substrates faces limitations due to their high cost and limited availability in comparison to 13 C-tracers. Furthermore, isotope tracer studies in industrially relevant bacteria that metabolize complex substrates such as cellulose, hemicellulose, or lignocellulosic biomass, are challenging given the difficulty in obtaining these as isotopically labeled substrates. In this study, we examine the potential of deuterated water ( 2 H 2 O) as an affordable, substrate-neutral isotope tracer for studying central carbon metabolism. We apply 2 H 2 O labeling to investigate the reversibility of glycolytic reactions across three industrially relevant bacterial species -C. thermocellum, Z. mobilis, and E. coli-harboring distinct glycolytic pathways with unique thermodynamics. We demonstrate that 2 H 2 O labeling recapitulates previous reversibility and thermodynamic findings obtained with established 13 C and 2 H labeled nutrient substrates. Furthermore, we exemplify the utility of this 2 H 2 O labeling approach by applying it to high-substrate C. thermocellum fermentations -a setting in which the use of conventional tracers is impractical-thereby identifying the glycolytic enzyme phosphofructokinase as a major bottleneck during high-substrate fermentations and unveiling critical insights that will steer future engineering efforts to enhance ethanol production in this cellulolytic organism. This study demonstrates the utility of deuterated water as a substrate-agnostic isotope tracer for examining flux and reversibility of central carbon metabolic reactions, which yields biological insights comparable to those obtained using costly 2 H-labeled nutrient substrates.

09 BIOMASS FUELS↗

Competition between Dissolved Organic Matter and Freshwater Plankton Control Methylmercury Isotope Fractionation during Uptake and Photochemical Demethylation

Isotope fractionation related to photochemical reactions and planktonic uptake at the base of the food web is a major uncertainty in the biological application of mercury (Hg) stable isotopes. In freshwater systems, it is unclear how competitive interactions among methylmercury (MeHg), dissolved organic matter (DOM), and phytoplankton govern the magnitude of mass-dependent and mass-independent fractionation. This study investigated how DOM alters rates of planktonic MeHg uptake and photodegradation and corresponding Hg isotope fractionation in the presence of freshwater phytoplankton species, Raphidocelis subcapitata. Outdoor sunlight exposure experiments utilizing R. subcapitata were performed in the presence of different DOM samples using environmentally relevant ratios of MeHg-DOM thiol groups. The extent of Δ199Hg in phytoplankton incubations (2.99‰ St. Louis River HPOA, 1.88‰ Lake Erie HPOA) was lower compared to paired abiotic control experiments (4.29 and 2.86‰, respectively) after ~30 h of irradiation, resulting from cell shading or other limiting factors reducing the extent of photodemethylation. Although the Δ 199 Hg/Δ 201 Hg ratio was uniform across experiments (~1.4), Δ 199 Hg/δ 202 Hg slopes varied dramatically (from -0.96 to 15.4) across incubations with R. subcapitata and DOM. In addition, no evidence of Hg isotope fractionation was observed within R. subcapitata cells. This study provides a refined examination of Hg isotope fractionation markers for key processes occurring in the lower food web prior to bioaccumulation, critical for accurately accounting for the photochemical processing of Hg isotopes across a wide spectrum of freshwater systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Oxygen stable isotopes in the nuclear fuel cycle: Assessment of the potential for determining the fabrication and provenance history of anhydrous and hydrous uranium oxides

Determining the origin and history of interdicted nuclear materials is a central challenge in nuclear forensics. The oxygen stable isotope composition of uranium oxide compounds has emerged as a promising forensic signature, attracting increasing attention since the early 2000s. This review examines analytical techniques for measuring oxygen isotope compositions in uranium oxides and evaluates how the nuclear fuel production cycle introduces or modifies these isotopic signatures. The potential for forensic geolocation is explored through workflows that calibrate the relationship between environmental water oxygen isotopes and those found in uranium oxides. Key strengths and limitations of this approach are assessed, including gaps in knowledge related to isotope fractionation during specific stages of the fuel cycle, and processing facility water inputs. The importance of proper sample handling and storage under inert atmospheres, as well as a deeper understanding of both intra-sample oxygen isotope heterogeneity, and hydrous uranium oxide phase formation, is highlighted for improving the reliability of forensic interpretations. In conclusion, the development of uranium oxide standards with well-characterized δ 18 O values and international collaboration toward consensus on their use are identified as essential steps for advancing the field.

Attribution↗

Sr-Nd-Pb isotope systematics of Australasian tektites: Implications for the nature and composition of target materials and possible volatile loss of Pb

The Australasian tektite (AAT) strewn field is the largest strewn field on the Earth with about ~10–30% coverage, both land and ocean, but a clearly identified source impact crater is absent despite the young age of AAT of ca. 790 ka. A genetic link between the Australasian tektites and their unequivocal parental materials is therefore largely impossible to establish. Nevertheless, the nature of the parental materials and the extent of volatilization can be constrained using the splash form tektites, carrying the chemical signatures of high-temperature processes, and the layered (so-called Muong Nong-type) tektites, which are less chemically homogenized and exceptionally abundant in the AAT field. New high-precision Sr, Nd and Pb isotopic measurements were obtained for a chemically and petrographically well-characterized suite of AAT, which included the Muong Nong-type (MN-AAT) with precisely known field locations in Laos and splash forms (SF-AAT) from different parts of the strewn field. Additionally, optically dark and light zones of the MN-AAT were also separately analyzed. Homogeneous ε Nd values from -11.8 to -11.2, combined with a narrow range of two-stage Nd model ages from 1.67 to 1.72 Ga for the entire AAT suite, point to a well-mixed source, in terms of REE, of the crustal segment from which the sedimentary material for tektites was ultimately derived. The Sr isotopic data largely overlap for SF-AAT and MN-AAT ( 87 Sr/ 86 Sr = 0.71636–0.72021) and indicate Paleozoic to Mesozoic sedimentary parentage. However, late Neogene to early Quaternary re-deposition and formation of a thick silt-sized sedimentary section with vertical stratification is required to comply with 10Be data. Lead isotope systematics documents at least three different components which can perhaps be represented by different mineral phases, such as feldspar, zircon, organic matter adsorbed on young sediments etc., sorted during fluvial transport and final deposition. In addition, the SF-AAT have systematically lower Pb contents than the MN-AAT, and generally show isotopically heavier Pb isotopic ratios. This is theoretically consistent with a preferential volatilization of lighter Pb isotopes during evaporation and considerably larger Pb loss from SF-AAT when compared to MN-AAT. Nevertheless, further experimental work would be necessary to unambiguously distinguish kinetic fractionation from source mixing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Position-specific carbon isotopes of Murchison amino acids elucidate extraterrestrial abiotic organic synthesis networks

The Murchison meteorite is a well-studied carbonaceous chondrite with relatively high concentrations of amino acids thought to be endogenous to the meteorite, in part because they are characterized by carbon isotope (δ 13 C) values higher than those typical of terrestrial amino acids. Past studies have proposed that extraterrestrial amino acids in the Murchison meteorite could have formed by Strecker synthesis (for α-amino acids), Michael addition (for β-amino acids), or reductive amination, but a lack of constraints have prevented confident discrimination among these possibilities, or assignment of specific formation pathways to each of several specific amino acids. Position-specific carbon isotope analysis differentiates amongst these mechanisms by relating molecular sites to isotopically distinct carbon sources and by constraining isotope effects associated with elementary chemical reactions. Prior measurements of the position-specific carbon isotopic composition of α-alanine from the Murchison CM chondrite demonstrated that alanine’s high δ 13 C VPDB value is attributable to the amine carbon (δ 13 C VPDB = +142 ± 20‰), consistent with Strecker synthesis drawing on 13 C-rich carbonyl groups in precursors (Chimiak et al., 2021). Here, we measured the δ 13 C composition of fragment ions generated by electron impact ionization of derivatized α-alanine, β-alanine, and aspartic acid from Murchison via gas chromatography-Fourier transform mass spectrometry. α-Alanine’s amine carbon yielded δ 13 C VPDB = +109 ± 21‰, which is consistent with the previously measured value and with formation from 13 C-rich precursors. β-Alanine’s amine carbon presents a lower δ 13 C VPDB = +33 ± 24‰, which supports formation from 13 C-rich precursors but potentially via a Michael addition mechanism rather than Strecker synthesis. Aspartic acid’s amine carbon has δ 13 C VPDB = -14 ± 5‰, suggesting synthesis from precursors distinct from those that generated the alanine isomers. Further, these measurements indicate that Murchison amino acids are a mixture of compounds made from different synthesis mechanisms, though some subsets likely drew on the same substrates; this conclusion highlights the complexity of extraterrestrial organic synthesis networks and the potential of emerging methods of isotope ratio analysis to elucidate the details of those networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Antimony stable isotope fractionation during adsorption onto birnessite: A molecular perspective from X-ray absorption spectroscopy and density functional theory

Sorption of antimony (Sb) onto birnessite significantly influences the fate of Sb in oceanic and terrestrial environments and fractionates Sb isotopes. Nevertheless, little is known about Sb isotopic fractionation during its adsorption on birnessite. Here, in this study, we show the value of Δ 123 Sb adsorbed-aqueous increases from −0.398 to −0.332 ‰ in 1 h and then decreases and stabilizes at −0.384 ‰ in 72 h. The enrichment of the light Sb isotope is predominantly due to the distortion of the octahedral symmetry. X-ray absorption spectroscopy results indicate Sb first forms a double-corner-sharing complex on birnessite and then transforms to a double-edge-sharing complex during adsorption. The optimized bond distances for double-corner-sharing (3.37 Å) and double-edge-sharing (2.90 Å) complexes calculated using density functional theory (DFT) fits well with the structure (3.41 and 3.00 Å) revealed by X-ray absorption spectroscopy, respectively. The fractionation derived from reduced partition function ratios calculated using DFT aligns well with the experimental results. Therefore, the variation in Sb isotopic fractionation during adsorption is attributed to the evolving structure of Sb complexes on birnessite. Our results demonstrate the isotopic fractionation of Sb during adsorption on birnessite and provide a molecular-scale understanding of Sb behavior, contributing to the correct reconstruction of the Sb isotope composition of ancient seawater using ferromanganese crusts and nodules, and efforts to trace Sb migration in epigenetic mining environments.

Adsorption↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗