Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance Evaluation of AG-1 FC Filters Under Upset Conditions and the Effects of Aging on Filters - 19501

High efficiency particulate air (HEPA) filters are routinely used in nearly every operating Department of Energy (DOE) and National Nuclear Safety Administration (NNSA) nuclear facility. These nuclear grade HEPA filters installed in DOE and NNSA confinement ventilation systems are credited as the final barrier to protect the environment, the public, and the worker from accidental release of virtually all airborne radioactive materials, and must meet the American Society of Mechanical Engineers' (ASME) Code on Nuclear Air and Gas Treatment (CONAGT) AG-1 standard. This testing activity evaluates ASME AG-1 Section FC axial flow HEPA filters, both separator and separator-less, under upset conditions. Additionally, testing efforts have analyzed the effects of filter degradation due to aging. In 1997, the Defense Nuclear Facilities Safety Board (DNFSB) raised concerns of the potential vulnerability of HEPA filters in vital safety systems, both from a design stand point and the potential for degradation of HEPA filter performance over time. The DOE Office of Environmental Management (DOE-EM) has a Cooperative Agreement with Mississippi State University (MSU) Institute for Clean Energy Technology (ICET) to conduct testing of HEPA filters. DOE-EM has established a Technical Working Group (TWG) of over thirty subject matter experts from the nuclear industry to provide input and oversight of ICET projects and activities. This has included establishment/approval of testing parameters for evaluating these filters under ASME NQA-1 compliant Test Plans. The current scope of work involves evaluation of the performance envelope for new and aged separator and separator-less designs of AG-1 Section FC axial flow HEPA filters. A range of elevated test conditions (T and RH) are used to determine the operating envelope within which DOE nuclear safety experts can credit installed HEPA filter performance, thereby establishing a risk-informed DOE service life. This paper will present preliminary test results of new and aged axial flow filters tested at ICET. Results in this paper include data collected from new separator and separator-less type FC HEPA filters and equivalent test data for a limited group of aged separator and separator-less type FC HEPA filters. Testing for both scopes of work evaluate initial filter performance under ambient conditions of temperature (60 deg. F - 80 deg. F (∼16 - ∼27 deg. C)) and relative humidity (40-60%), loading of each filter with Aluminum Trihydroxide, Al(OH)3, to a specified differential pressure, and then exposing the filter to specified elevated temperature and relative humidity conditions. In addition to the upset conditions of elevated temperature and relative humidity, the performance of HEPA filters under fire scenarios is not well characterized. ICET is currently designing a burn box and testing apparatus to study the effects of fire from burning liquids and a wide range of blends of combustible solids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure–Property Relationships of Recycled Lithium-Ion Battery Cathodes: Microstructure Optimization Using Virtual Materials Testing

The increasing demand for sustainable battery technologies requires effective recycling strategies for end-of-life lithium-ion battery cathodes. In this study, virtual materials testing, a well-established framework for modeling conventionally manufactured NMC-based cathodes, is applied to partially recycled cathodes. To this end, virtual cathodes consisting of mixtures of pristine and recycled NMC particles are utilized to systematically analyze structure–property relationships depending on mixing ratios and different spatial arrangement strategies. For this purpose, a stochastic 3D model is developed that is capable of generating virtual cathodes with arbitrary volume fractions of active materials and mixing ratios of pristine and recycled NMC particles. Particularly, the stochastic 3D model can mimic the different size distributions of pristine and recycled particles that are observed in image data. Additionally, the model allows the structuring of pristine and recycled NMC either uniformly mixed or layer-wise arranged, mimicking single- and dual-layer cathodes. Subsequently, a systematic computational analysis is conducted to assess the influence of increasing active material ratios of recycled particles, ranging from 0 % to 100 %, while maintaining a constant overall active material volume fraction. The impact of particle mixing on cathode performance is evaluated by examining transport-relevant geometrical descriptors and effective properties, such as geodesic tortuosity, specific surface area, and tortuosity factor.

25 ENERGY STORAGE↗

The Effect of Heat Treatment Process Parameters on Mechanical Properties, Precipitation, Fatigue Life, and Fracture Mode of an Austenitic Mn Hadfield Steel

In this study, the effect of cooling rate after heat treatment on mechanical properties, fatigue life, precipitation and fracture mode of an austenitic Mn Hadfield steel was investigated. Cast samples of the Hadfield steel were heat treated at 1100 C for 2 h. The samples were subsequently quenched in pure water and also in 3 wt.% NaCl salt bath. Optical microscope (OM) and scanning electron microscope (SEM) were used to analyze microstructure and fracture surfaces. Transmission electron microscope (TEM) was used to assess the precipitates. X-ray diffraction (XRD) was used to determine the phases formed. Mechanical properties and fatigue life were determined by uniaxial tensile test, bending fatigue and hardness measurements. Results showed that the sample quenched in salt bath had lower Mn{sub 3}C precipitates, hardness, yield and tensile strengths. Instead, this situation resulted in a more ductile fracture mode and higher formability. Finally, the fatigue life of the sample quenched in salt bath was longer than the one quenched in pure water.

36 MATERIALS SCIENCE↗

Dynamic System Scaling Application to Accelerated Nuclear Fuel Testing

The development of nuclear fuel and materials requires a continuous effort to investigate the acute and prolonged effects of irradiation, thermal-material stress, chemical change, or other conceivable damage mechanics acquired during normal operation or accident scenarios throughout its lifetime. As in-core fuel property measurement techniques advance to support in the real-time, non-invasive, and enhanced accuracy realm, it is the future of fuel development to pursue to higher degrees of control, predictability of integral test behavior via separate effects test (SET), and shorter test time intervals. The fuel development life cycle from initial concept to commercial licensing is approximated to be 20 years and current literature suggests by optimizing fuel performance codes with SETs, the process could possibly be compressed to 5 to 10 years. Recently, a research group in the Idaho National Laboratory (INL) is testing reduced scale fuel rods and increased power density to accelerate evolution of fuel phenomena in metallic fuels. In support of nuclear fuel rod development, compressing fuel test process, and accelerating fuel phenomena, it was the purpose of this study to investigate nuclear fuel performance phenomena via literature review and effectively scale the initial conditions, boundary conditions, and geometric properties to describe the time-dependent response including to fuel burnup, thermal and mechanical stress, transmutations and inter-diffusion, and other relevant observed phenomena. The study was based on BISON simulations of historic EBR-II metallic fuel experiments and Dynamical System Scaling (DSS) method are utilized to assess effects of scaling activity including fuel phenomena acceleration and calculations of time-dependent distortions. The research successfully scaled metallic fuel phenomena, accelerated fuel testing, and assessed the distortions for each scaled case derived.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calendar-life versus cycle-life aging of lithium-ion cells with silicon-graphite composite electrodes

The use of blended silicon-graphite (Si-Gr) negative electrodes increases the energy density of lithium-ion cells over those containing only graphite (Gr) electrodes. However, volume changes in the Si particles that occur during cycling causes deterioration of the solid-electrolyte interphase (SEI) layer on the particles resulting in further electrolyte reduction that immobilizes Li+ ions and, therefore, capacity fade. Because the volume changes are not expected to occur during a potentiostatic hold (referred to as calendar-life aging), by comparison of cycle-life and calendar-life aged cells one can expect to assess the role of volume changes in the deterioration of cell performance. To this end, cells with Si-Gr and Gr negative electrodes (and Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 containing positive electrodes) were assembled, tested, and compared using cycle-life and calendar-life aging protocols. As expected, the capacity loss of the cycle-life aged cells was higher than that of the calendar-life aged cells. However, the measurable capacity loss for the calendar-life aged cells indicated continued immobilization of Li + ions. Furthermore, electrolytes extracted from the calendar-life aged cells showed more LiPF 6 hydrolysis products than those extracted from the cycle-life aged cells. In conclusion, we discuss possible mechanistic causes for the observed aging behaviors in this article.

25 ENERGY STORAGE↗

Destructive Examination of a FeCrAl-UO 2 Irradiation Test

Several destructive postirradiation examinations were performed on an irradiation specimen that coupled an early iron-chromium-aluminum (FeCrAl) candidate alloy cladding with UO2 pellets. This irradiation test was designed to investigate the early life performance and compatibility of the FeCrAl-UO 2 cladding-fuel system under prototypic light water reactor neutronic conditions. Additionally, these tests were expected to provide neutron irradiated samples for severe accident testing of this fuel system. The irradiation studied in this work was part of the ATF-1 series of drop-in style irradiations performed in the Idaho National Laboratory Advanced Test Reactor. The rodlet studied in this work is one of three similar rodlets irradiated in ATF-1 that had approximately 7.6 cm of cladding machined from a wrought FeCrAl alloy and fueled with a 6.1 cm stack of UO 2 pellets. The outer diameter of the cladding was ~0.94 cm and the inner diameter was ~0.83 cm. After irradiation and non-destructive examination in Idaho this rodlet was shipped to the Oak Ridge National Laboratory hot-cells for further examination. The irradiated rodlet was sectioned into several samples for microstructural, micromechanical, and severe accident testing. During sectioning, it was noted that the fuel was not firmly bonded to the cladding and could be readily removed from small cladding slices. Microstructural characterization of fuel cross sections also revealed no significant interaction between the fuel and the cladding. Samples were also prepared for microhardness testing. To prepare for high temperature oxidation testing, the fuel was dissolved from segments of the cladding. High temperature oxidation testing of cladding segments was performed at 1200°C and 1300°C in a steam environment. Comparisons between the oxidation of this FeCrAl alloy in its neutron irradiated state, as-fabricated state, and the oxidation of Zircaloy-2 are made. The oxidation testing will be followed by ring compression testing to evaluate ductility. The microstructure of the samples after oxidation and ring compression testing will also be analyzed.

Harp, Jason↗

Results of the Phenix Dissymmetric Test Benchmark Exercise

In the context of the European H2020 project SESAME, a work package was dedicated to the validation of code coupling for the thermal-hydraulics of pool type reactors. To this end, CEA proposed a benchmark exercise of the so-called dissymmetric test performed at the end of life of the PHENIX reactor. The PHENIX reactor was an experimental reactor operated by CEA in France from 1974 until 2009. The knowledge and data acquired over the lifetime of this reactor are of paramount importance for the development of future sodium-cooled generation IV reactors. At the beginning of this test, the reactor is operated at nominal power (350 MWth) with 3 primary pumps and 4 intermediate heat exchangers. During this test, a pump trip occurs at the secondary side of one of the two loops (one loop provides coolant to two intermediate heat exchangers). The chain reaction is then stopped while the pumps remain operating at nominal speed. Dissymmetric flow patterns are then observed in the cold pool as hot sodium leaves the intermediate heat exchangers that are no longer cooled. The failed secondary pump is then restarted while the rotational speed of the other is reduced. Eventually, a stable homogeneous state is reached. This transient is challenging for both modelers and codes since this exercise tackles an industrial scale reactor featuring complex flows and interactions between different scales. The physical phenomena observed include thermal stratification, flow mixing and buoyancy effects. In order to accurately model these phenomena for a reasonable computational costs, the partners used System Thermal Hydraulics codes coupled with Computational Fluid Dynamics codes and one even included a subchannel code. In this paper, the PHENIX reactor and its behavior during the dissymmetric test are described. Then, a comparison of the different modeling options selected by the partners is offered. Finally, the results are compared to the experimental data and discussed and modelling recommendations are proposed.

code coupling↗

Effect of Prestrain on the Fatigue Life of Superelastic Nitinol

Three types of fatigue testing are performed to elucidate the effects of prestraining superelastic Nitinol on its subsequent fatigue lifetime: rotary bending and tension–tension testing of wire, and beam bending using diamond-shaped specimens fabricated from tubing. Results show that local plastic deformation during prestraining induces residual stresses that have a pronounced effect on fatigue performance, enhancing performance when the fatigue duty cycle is of the same sense as the prestraining (tensile prestraining followed by a tensile duty cycle, for example), and decreasing fatigue lifetime when the sense of the duty cycle is opposite to that of prestraining. This provides an avenue to increasing fatigue lifetime, but more importantly it highlights the need to fully understand the nature of the duty cycle: for example, prestraining a stent by crimping it into a delivery catheter induces favorable residual stresses with respect to subsequent pulsatile fatigue, but might accelerate fracture in other modes, such as axial or crush fatigue. Caution is also advised when trying to apply data from “constant life diagrams” derived from the literature (Ref 1, 2 for example) that may not properly reflect the strain history of the device being analyzed.

36 MATERIALS SCIENCE↗

Adhesion and tribological characteristics of modified polyurethane coating on composite substrate

In the present study, glass-epoxy composites were used as a substrate to study the performance of modified polyurethane coating. Two-layer coating (180–200 µm) wherein the epoxy primer as the first coat and polyurethane as the top coat was applied using an air-assisted spray gun to increase the service life of the composite. The analysis of coating was performed using gloss, contact angle, FTIR, TGA, tensile test and SEM. The bonding strength between coating and substrate was evaluated by cross-hatch cut, 180 deg peel strength and pull-off adhesion tests. Scratch, Taber abrasion and Pin-on-disc tests were also performed to evaluate the wear resistance. In addition, a rain erosion test was performed to check the stability of the coating. From the above tests, it is concluded that the applied coating well adhered to the composite substrate. The data generated from different tests can be used to estimate the service life of polymer composites and coatings.

Mushtaq, Mohammed↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Regime dependence of ice cloud heterogeneity – a convective life‐cycle effect?

Cloud condensate varies on scales smaller than those typically resolved by global weather and climate models. In order to accurately predict the radiative and microphysical process rates representative of the entire model grid box, the effect of the subgrid‐scale heterogeneity of cloud must be taken into account. In this study, observed ice water content retrieved from A‐Train satellite observations is used to explore how spatial ice condensate variability, characterized by the fractional standard deviation (FSD, the standard deviation divided by the mean), varies with cloud regime. FSD is generally lower for overcast cloud scenes, but an additional predictor based on convective activity is needed to capture the high FSD associated with more turbulent clouds and reproduce the observed latitudinal and height variations of FSD. Convective clouds that extend only a few kilometres above the freezing level are likely to be smaller at an earlier stage in their life cycle, and actively growing with a higher FSD. In contrast, more mature clouds reaching the tropopause are larger and generally have a lower variability and smaller FSD. To capture this life‐cycle effect, a new parametrization is tested which uses the ratio of a model's convectively detrained condensate to the existing cloud condensate mass as a proxy for the cloud's convective life stage to highlight areas with enhanced condensate variability. The parametrization is scale‐adaptive, situation‐dependent and captures seasonally varying global patterns and the zonal mean vertical structure of observed ice condensate variability well. Ground‐based observations obtained from five Atmospheric Radiation Measurement sites provide independent confirmation that the parametrization satisfactorily captures condensate variability in high‐altitude ice clouds.

Ahlgrimm, Maike↗

Corrosion Testing of Refractory in Contact with Molten Glasses Designed for Waste Vitrification

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Specimen sizing and remaining life sample calculations for high temperature reactor material surveillance

Advanced high-temperature nuclear reactors rely on structural components that will operate for decades under combined mechanical, thermal, and environmental loading. Materials surveillance programs are a promising strategy for managing the resulting uncertainty in long-term structural integrity by monitoring degradation in service using passively actuated mechanical test articles. Previous reports have developed a simplified, spreadsheetimplementable framework for sizing these test articles and for inferring accumulated creep damage and remaining life from ex-situ test data. This report advances that work toward practical deployment by providing a sample-problem book: a collection of worked, end-toend examples in which the ASME Section III, Division 5 design analysis of a representative high-temperature reactor component is carried through to a sized surveillance article, verified with detailed finite-element analysis, and concluded with a remaining-life assessment based on an assumed ex-situ creep-rate measurement on the retrieved specimen. The report also summarizes ongoing ANL engagement with ASTM Committee E10 on Nuclear Technology and Applications toward drafting a standard covering surveillance procedures for advanced reactors.

Barua, Bipul (ORCID:0000000247184113)↗

Chapter 13: A Simple Estimation of UV Irradiance Under Clear-Sky Conditions

Accelerated aging tests are designed to estimate the useful life of products in their end-use environment. There is currently no simple way to answer the age-old question: “How long should I run my weathering test to reproduce 1 year of outdoor aging?” At the very least, there is need to (1) evaluate the acceleration rate associated with each stress factor and (2) estimate the intensity of the stress factors that the products under scrutiny are exposed to in natural aging. In this chapter, a model is introduced to calculate the ratio between ultraviolet (UV) irradiance and global horizontal irradiance (GHI). This method was empirically derived from measured or simulated irradiance data and validated against outdoor observations. This ratio provides a simple way to estimate the UV dose that samples are exposed to at any outdoor location.

ENERGY PLANNING, POLICY, AND ECONOMY,OTHER INSTRUM↗

Final Report on CFD and Thermal-Mechanical Stress Analysis of PWR Surge Line under Transient Condition Thermal Stratification and an Evolutionary Cyclic Plasticity Based Transformative Fatigue Evaluation Approach without Using S~N Curve: Rev. 1

This report presents an evolutionary cyclic plasticity based transformative approach for fatigue evaluation of safety critical components. This approach is generic which can be used not only for the present generation light water reactor components (which is our focus) but also for advanced reactor components. The approach is based on the fundamental concept of time-evolution of progressive fatigue damage rather than the end-of-life data based conventional S~N curve approaches. Series of fatigue tests on 316 stainless steel uniaxial specimens were conducted under strain-controlled and stress-controlled cyclic loading in two different environment such as in-air at 300 °C and PWR coolant water condition at 300 °C. Material models are developed to capture the uniaxial test data and are subsequently programmed into commercially available ABAQUS code to transform the uniaxial material behavior to multiaxial loading domain. The developed evolutionary cyclic-plasticity approach is verified by both analytical and 3D-FE modeling of uniaxial fatigue test specimens. Results show that the developed material models can capture the time-dependence of material hardening and softening with great accuracy. In addition, results show that the material models not only can capture the material behavior under constant amplitude loading but also can capture the load-sequence effect under variable and random amplitude loading. The ANL developed approach is one of its kind, which shows first in the fatigue research community that fatigue evaluation of a component (in our case verified for laboratory scale fatigue test specimens with great accuracy) can be performed for its entire fatigue life, including the hardening and softening behavior, without using a conventional S~N curve based approach. Additionally results are presented related to fatigue evaluation of real reactor components such as of a pressurized water reactor (PWR) surge line (SL), under upset transient conditions. SLs of PWR experience complex thermal stratification due to the mixing of differential temperature flow from hot leg and pressurizer. A detailed parametric study of thermal stratification in SL is performed through both standalone computational fluid dynamics (CFD) analysis and fluid-structure-interaction based coupled CFD and heat transfer analysis. Results show that the mass flow rate in SL substantially affects the extent of its thermal stratification. The resulting thermal boundaries conditioned are used as inputs for thermal-mechanical stress analysis and component level fatigue evaluation. Fatigue evaluation of SL pipe under example loading conditions was performed using the above-mentioned evolutionary-plasticity based approach and ASME code (for in-air life) and NUREG-6909 (for PWR environment life) based approaches. Results show that the evolutionary plasticity based approach estimate substantially different life compared to the conventional ASME based approach. To show the entirety of the proposed evolutionary fatigue-modeling framework, this report includes the results presented in semi-annual March report (ANL/LWRS-17/01). Sections 2-5 of March report are directly included as Sections 2-5 in this report, without any significant changes. However, Sections 6-9 of this report present the work performed during March-September of 2017. Whereas, Sections 1 and 10 present the organization of this report and the summary and future work, respectively. This report (ANL/LWRS-17/03 Rev. 1) is a slightly revised version of the earlier published report (ANL/LWRS-17/03). In this revised version, some of the results and associated discussion have been corrected/updated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Augmented Monitoring and Condition Assessment Program for SNF Wet Storage Life Extension - 20489

Approximately 27 MTHM of spent nuclear fuel (SNF) owned and managed by the U.S. Department of Energy, Office of Environmental Management is stored in the L Basin at the Savannah River Site (SRS). This 'DOE SNF' is comprised of approximately 12,000 aluminum-clad, aluminum-based fuel assemblies (∼7 MTHM), and approximately 2000 non-aluminum fuel assemblies (∼20 MTHM). A program is in progress to perform Non-Destructive Examination (NDE) of the fuel and their storage containers to characterize the materials' condition, and to evaluate the effects of service to enable continued safe wet storage of the SNF. The Augmented Monitoring and Condition Assessment Program (AMCAP), a two-part program to develop and implement remote underwater Non-Destructive Examination of the aluminum SNF, and of the containers of the non-aluminum SNF, respectively, is aimed at the characterization and evaluation of corrosion degradation of aluminum fuel and container materials. The predominant design of the aluminum SNF (ASNF) stored in L Basin is the Materials Test Reactor (MTR) equivalent design, a plate fuel design. These SNF are stored in 5'' diameter tubes or 5'' x 5'' squares (called bundles) that are nominally 12' or up to 14' long. The SNF is de-bundled and inspected using a custom-designed MTR Fuel Inspection Table. The inspection table provides for indexed fuel positioning for a video camera examination with controlled lighting. A total of 10 of the SNF originating from foreign research and test reactors were selected for examination based on burnup, enrichment, and prior damage caused by service/storage history. A special inspection campaign of these 10 assemblies is in progress. The observed corrosion damage included minor to moderate attack from general corrosion, pitting, crevice, end grain and galvanic corrosion. Example results from the completed inspections are shown and discussed. The focus is a comparison of the as-received condition versus the as-found current storage condition that will serve to validate Water Chemistry and Corrosion Monitoring Programs. The non-aluminum SNF (NASNF) stored in L Basin are of diverse design that includes various geometries with claddings of stainless steel, Zircaloy, and Hastelloy. The fuel core materials include uranium alloys, oxides/mixed oxides, and carbides. These SNF materials, originating from early experimental and test reactors, are in various physical forms including single fuel elements and cut pieces. The fuel is stored in L Basin in various configurations including in direct bundled storage in aluminum tubes and in isolation cans that are in the bundles or in a larger over-size storage container (OSC). Concern with inside-out corrosion and the potential loss of configuration control and ability to handle the storage containers prompted the development of remote NDE methods that include visual and UT technologies to assess the condition of the containers. Candidate stored materials were selected for a special inspection campaign; the development of the NDE methods for the inspection for galvanic, crevice and sediment-induced corrosion (inside-out) are discussed. A summary of the SNF storage in L Basin at the SRS, and an overview of the AMCAP to enable continued safe storage of DOE SNF are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Calibration Approaches for the Stress Relaxation Test

Advanced manufacturing technologies are enabling the next generation of superalloys for extreme temperatures, pressures, and longevity. There is a need for Accelerated Creep Test (ACT) methods to reduce the time needed to implement new creep resistant superalloys. Without the development of ACTs, the qualification of new superalloys using conventional creep tests can take 11+ years corresponding to the 100,000-hour service life of long-lived turbomachinery components. A refined stress relaxation test (SRT) is introduced to succeed real-time conventional creep tests (CCTs). The stress relaxation test generates extensive stress versus creep-strain-rate data within a single specimen. Since the specimen is held below the elastic limit and relatively little creep deformation has occurred, several SRTs at different temperatures can be performed using a single specimen. To obtain data, specimens are rapidly loaded in force-control to just below the elastic limit. The specimen is switched to displacement-control and held at a fixed displacement while stress relaxation occurs. This generates a stress versus time curve that must be converted into stress versus creep-strain-rate. The stress versus creep-strain-rate curves are utilized to calculate creep activation energy and produce a creep-strain-rate master curve. The objective of this study is to determine the best calibration approach for SRT: regression of stress, regression of creep strain, and the finite difference of creep strain. It is recommended that the differentiation be applied; however, finite difference applied to the raw data produces inconsistent calculations of the creep-strain-rate. In this study, a MATLAB algorithm is written to evaluate all three calibration options where, stress and creep deformation are regressed into natural logarithm functions. The resulting creep-strain-rate curves are compared to determine the most reliable and consistent method. Analyzing and evaluating the results the regression of stress and regression or creep strain calibration methods prove to provide accurate results. These methods will help replace CCTs by conducting less expensive ACTs, while increasing the overall efficiency of the development of new materials.

36 MATERIALS SCIENCE↗