Benchmarking of ENDF/B-VIII.1 Thermal Scattering Library for Hydrogen

In correctly characterizing the energy and momentum transfer at thermal and cold energies between neutrons and its interacting medium, thermal scattering libraries, which details energy states due to the intra- and inter-molecular bond effects for the medium materials, are applied in place of free-gas cross section libraries in a particle transport simulation code. They are essential to the neutron performance of a neutron facility like SNS, where thermalized neutrons from 20 K liquid hydrogen and ambient (~300 K) water are transported to the beamlines for neutron scattering experiments in studying materials. Recently, a new version of thermal scattering library for parahydrogen and orthohydrogen at 14-20 K was developed and to be released in ENDF/B-VIII.1. It is, therefore, important to benchmark its impacts on the prediction of moderator performance due to the updates in the thermal scattering library. In this study, the recent ENDF/B-VIII.1 thermal scattering library was compared to the current ENDF/B-VII.1 one in the neutron performance calculations for the decoupled and coupled hydrogen moderators at SNS under theorized and real working conditions. In addition, the predictions using both thermal scattering libraries were benchmarked to the measurements of moderator performance. The consistency between the libraries was observed mostly for parahydrogen and the difference in orthohydrogen at cold neutron energies was noted.

Lu, Wei [Oak Ridge National Laboratory (ORNL), Oak

Insights into the thermo-hydraulic properties of compacted MX80 bentonite during hydration under elevated temperature

In high-level radioactive waste geological repositories, compacted bentonite undergoes coupled thermo-hydraulic processes due to heat released from a central waste canister and groundwater imbibition from the surrounding host rock. An understanding of these processes is essential for long-term simulations of radionuclide migration and canister corrosion, which requires an understanding of temperature effects on the coupled thermo-hydraulic properties governing these processes. In this study, a tank-scale radial infiltration test was used to investigate water imbibition processes in compacted bentonite under a central heater temperature of 200 °C that simulates high thermal gradients in a repository. Interpretation of this test focuses on evaluation of the liquid water wetting front during hydration and the interpretation of the temperature-dependent transient soil water retention curve (SWRC), thermal conductivity function (TCF), and hydraulic conductivity function (HCF). The SWRC during imbibition follows a temperature-dependent wetting path. Temperature effects on the hydraulic conductivity of bentonite in saturated conditions had the greatest effect on the shape of the HCF, with minimal temperature effects at higher suctions. The transient thermal conductivity data matched well with a new TCF linked with the SWRC shape. Although the bentonite layer was restrained, local deformations during hydration may have affected the shapes of the TCF and HCF.

Engineering

Interaction of magnetic fields with spinons in a fractionalized state

The 4d-electron trimer lattice Ba₄Nb₁₋ₓRu₃₊ₓO₁₂ exhibits either a quantum spin liquid (QSL) or a heavy-fermion strange metal (HFSM) phase, depending on Nb content. In the QSL state, itinerant spinons act as effective heat carriers, enhancing thermal conductivity. Strikingly, applying a magnetic field up to 14 T causes an abrupt, up-to-5000% increase in heat capacity below 150 mK, disrupting the linear temperature dependence typical of both phases. Meanwhile, AC susceptibility and electrical resistivity remain nearly unchanged, while thermal conductivity drops by up to 40% below 4 K. These results suggest spinons, despite being charge-neutral, are highly sensitive to magnetic fields at low temperatures. We propose that the magnetic field could induce Anderson localization of spinons, creating emergent non-magnetic two-level systems responsible for the Schottky-like anomaly in heat capacity. These findings point to a previously unexplored regime of spinon dynamics, potentially governed by field-induced localization and distinct from conventional magnetic or transport signatures.

Condensed-matter physics

Nuclear Reactor Heat Extraction for Synthetic Fuel Plants

This report looks at the viability and best approach when producing synthetic fuels using heat and power supplied by advanced nuclear energy systems. The report looks at a low temperature integration pathway with four types of advanced reactors: a pressurized water reactor (PWR), an advanced light water reactor (A-LWR), a sodium fast reactor (SFR), and a high-temperature gas-cooled reactor (HTGR). A failure modes and effects analysis (FMEA) of the coupling system between the nuclear plant and the synthetic fuel systems is performed with the goal of identifying the reliability of such a thermal delivery system. Furthermore, a high temperature pathway is investigated for synfuel coupling to determine if this is more efficient and more cost effective as a coupling approach.

10 - SYNTHETIC FUELS

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

Study of wrap mode impact on Pseudomonas aeruginosa motion in the chemotactic field of fungi

An agent-based discrete computational model biologically calibrated to Pseudomonas aeruginosa migration is used to explore the impacts of bacterial reversals and wrap mode on the efficiency of motion in different environments, both with and without chemotaxis. It is first shown that wrap mode increases the exploration of continuous multimodal chemotactic profiles such as those produced by biologically relevant fungal networks. For cells undergoing a run-reverse pattern, it is shown that the bacteria are likely to remain at the first local chemoattractant maximal production site on a hypha they find. However, with wrap mode, the bacteria can more easily escape these local sites to further explore their neighboring environment along the fungi, suggesting that wrap mode may be beneficial for migration along the fungi in liquid. In a different set of simulations of bacterial motion close to an isolated chemotactic source, wrap mode is shown to increase the ability of a bacterium to reorient toward the source while reducing the overall motion required for similar chemotactic efficiency as a run-reverse strategy, suggesting a potential metabolic benefit. In contrast, model simulations show that wrap mode can increase the rate of dispersal of P. aeruginosa in a nonchemotactic environment.

Hansen, Austin [University of California, Riversid

Molecular origin of anisotropic shear elastoplasticity in chitin

Chitin nano- and mesoscale structures present in the exoskeleton of crustaceans exhibit exceptional longitudinal stiffness and toughness, rivaling or even exceeding that of many synthetic polymer architectures. Here, we reveal the origin of the asymmetric shear response in chitin multiscale architectures, marked by pronounced anisotropy in deformation. Under shear aligned with the molecular axis, chitin accommodates strain through coherent atomic rearrangements that enable elastic recovery. In contrast, shear applied perpendicular to this axis induces liquid-like plasticity via localized sliding. These results demonstrate the intrinsic mechanical anisotropy of chitin, underpinning a dual function in resisting repetitive loading while dissipating internal stress during high-strain events. Our findings establish the molecular basis of shear elastoplasticity in multiscale chitin structures, wherein axial elasticity supports energy storage in load-bearing regions, whereas transverse plasticity enables controlled energy dissipation. These atomic-scale insights lay a foundation for the predictive design of chitin-based materials with tunable strength-toughness profiles.

Wan, Zhangmin [University of British Columbia, Van

Mechanically and Thermally Robust Gel Electrolytes Built from A Charged Double Helical Polymer

Polymer electrolytes have received tremendous interest in the development of solid-state batteries, but often fall short in one or more key properties required for practical applications. Herein, a rigid gel polymer electrolyte prepared by immobilizing a liquid mixture of a lithium salt and poly(ethylene glycol) dimethyl ether with only 8 wt% poly(2,2′-disulfonyl-4,4′-benzidine terephthalamide) (PBDT) is reported. The high charge density and rigid double helical structure of PBDT lead to formation of a nanofibrillar structure that endows this electrolyte with stronger mechanical properties, wider temperature window, and higher battery rate capability compared to all other poly(ethylene oxide) (PEO)-based electrolytes. The ion transport mechanism in this rigid polymer electrolyte is systematically studied using multiple complementary techniques. Li/LiFePO 4 cells show excellent capacity retention over long-term cycling, with thermal cycling reversibility between ambient temperature and elevated temperatures, demonstrating compelling potential for solid-state batteries targeting fast charging at high temperatures and slower discharging at ambient temperature.

36 MATERIALS SCIENCE

Computational modeling of coupled mechanical damage and electrochemistry in ternary oxide composite electrodes

Performance degradation of ternary layered oxide cathodes largely originates from their loss of structural integrity in cyclic usage. Mechanical damage, such as intergranular fracture of the active particles, is not only a mechanical cleavage process but also interferes with electrochemical kinetics such as infiltration of liquid electrolyte, surface corrosion of the constituent primary particles, and may eventually isolate the primary grains from the electron conducting network. Here, in this work, we develop a computational framework that integrates electrochemistry of a LiNi x Mn y Co 1−x−y O 2 (NMC) composite cathode with mechanical damage of the active particles. To fully examine the intricate chemomechanical behavior of the electrode, we evaluate the effects of the anisotropic material properties, the influence of mechanical potential on Li transport, and the concurrent intergranular fracture and electrolyte penetration along the grain boundaries upon multiple cycles. Electrolyte infiltration benefits capacity retention but aggravates further mechanical damage by corrosion. Structural failure mostly occurs in the first charging due to the anisotropic mechanical strain between the primary grains, while the resulting damage remains stable in the later few cycles. The results are consistent with experimental observations and the integration of electrochemistry and mechanical failure enables a step further understanding of the complex mechanism of battery degradation.

Battery degradation

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

Mesoscale Magnetostructural Phase Separation in Fe‐deficient Fe 5 GeTe 2

Two-dimensional van der Waals ferromagnet Fe 5-x GeTe 2 (F5GT) is promising for spintronic applications due to its high Curie temperature, layered structure, and ability to host complex magnetic textures. However, the origin of its sample-dependent magnetic anisotropy remains unclear, hindering control of its magnetic behavior. Here, we use spatially resolved cryogenic scanning transmission electron microscopy (STEM) to correlatively map magnetism, lattice structure, and chemistry across atomic-to-micron scales. We reveal that only mesoscale, not nanoscale, inclusions of a Fe-deficient secondary phase significantly modify magnetic behavior, establishing a previously unrecognized critical length scale. This phase separation, induced by quenching, leads to in-plane magnetic anisotropy, while slow cooling confines separation to a few nanometers and preserves out-of-plane anisotropy. These findings reconcile prior inconsistencies and establish a predictive framework for tuning magnetism in F5GT through thermal processing, with broader implications for controlling anisotropy in other two-dimensional magnetic materials.

2D ferromagnets

Rapid Quantum Ground State Preparation via Dissipative Dynamics

Inspired by natural cooling processes, dissipation has become a promising approach for preparing low-energy states of quantum systems. However, the potential of dissipative protocols remains unclear beyond certain commuting Hamiltonians. This work provides significant analytical and numerical insights into the power of dissipation for preparing the ground state of noncommuting Hamiltonians. For quasi-free dissipative dynamics, including certain 1D spin systems with boundary dissipation, our results reveal a new connection between the mixing time in trace distance and the spectral properties of a non-Hermitian Hamiltonian, leading to an explicit and sharp bound on the mixing time that scales polynomially with system size. For more general spin systems, we develop a tensor network-based algorithm for constructing the Lindblad jump operator and for simulating the dynamics. Using this algorithm, we demonstrate numerically that dissipative ground state preparation protocols can achieve rapid mixing for certain 1D local Hamiltonians under bulk dissipation, with a mixing time that scales logarithmically with the system size. We then prove the rapid mixing result for certain weakly interacting spin and fermionic systems in arbitrary dimensions, extending recent results for high-temperature quantum Gibbs samplers to the zero-temperature regime. Together, these results show that dissipation can be a powerful tool for ground state preparation, with potential applications across condensed matter physics, quantum materials science, and beyond.

decoherence

Reduction of baseplate distortion during directed energy deposition using compliant features

Distortion in additive manufacturing (AM) remains a barrier to its adoption in precision industries. Baseplate warpage is one such issue which compromises the feasibility of post-process precision machining. The restriction to thermal contraction of the deposited part, imposed by the baseplate, generates bending moments, that in turn causes warpage. A novel distortion mitigation strategy using baseplates with integrated compliant features, which enables thermal contraction of the build is presented. Six unique design concepts are evaluated, including a solid reference, using two deposition geometries. A laser, hot-wire, directed energy deposition (DED) process is used to deposit a symmetric cylindrical part (C-part) and a T-shaped asymmetric part (T-part). Flatness deviation of baseplates is measured using structured light 3D scanning. Measurements reveal a reduction in net flatness deviation of 58.8% for the C-part and 40.9% for the T-part, compared to the solid reference. While most designs yielded reductions exceeding 30% and 20% for the C- and T-parts, respectively, one configuration resulted in increased deviation. Finite element (FE) simulations are performed to elucidate the underlying mechanisms affecting distortion of compliant baseplates during DED. Despite variations between predictions and measurements, agreement in the general trend is observed. It also revealed that initial flatness errors in baseplates significantly affect its deviation during deposition. Predictions indicate that compliant features significantly affect the thermal distribution as well as the evolution of flatness deviation in the baseplate during deposition. Notably, one design exhibited a reduction in distortion during cooling, following its initial increase during deposition. FE predictions show a maximum reduction of 60.9% and 38.8% in net flatness deviation for the C- and T-parts, respectively. The performance of compliant baseplates is found to be governed by both its the thermal and mechanical characteristics, which are crucial factors to be considered during design.

Mathews, Ritin [ORNL] (ORCID:0000000301440828)

Boron Coordination in Multicomponent Glasses: Analytical Models and Machine Learning With Uncertainty

Borosilicate glasses are extensively used in a variety of applications from kitchenware to nuclear waste immobilization due to the strong network formed by the Si-O-B bond that makes it resistant to chemical corrosion and gives it a low thermal expansion. Boron, however, exists in both trigonal BO3 and tetrahedral BO4 bonds in glass systems, which impacts the chemical durability and thermal resistance of the glass, amongst other properties. Boron coordination (N4), or the ratio of the amount of BO4 to BO3 within a glass, may aid in predicting these properties but is difficult to derive without experimental data due to the complexity of impacts from varied glass compositions and processing factors. For this reason, compositional models have been developed to predict boron coordination, but the models typically include a limited number of glass components. To help fill this gap in the models, in this work, a diverse multicomponent glass dataset of 809 glasses is compiled from a literature search, and then a number of analytical and machine learning (ML) models are trained on the dataset. Previously developed modified Bernstein and modified Du Stebbins analytical models were fitted to update parameters with the new dataset. Then, partially Bayesian neural networks, Gaussian process regressor, and heteroskedastic deterministic neural networks were evaluated. The ML models examined all have different strategies to overcome the potential for overfitting as a result of a limited training dataset, and return results that account for model uncertainty, which can be valuable for understanding model reliability. For the first time, cooling rate is introduced as an input parameter for ML models, showing consistent improvements in performance and solidifying the importance of including parameters outside of composition alone for N4 prediction. The machine learning models examined here show promise in accurate predictions of boron coordination in borosilicate glasses, all achieving R2 values of 0.91.

boron coordination

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The impact of aerosol mixing state on immersion freezing: insights from classical nucleation theory and particle-resolved simulations

Immersion freezing, initiated by ice-nucleating particles (INPs) in supercooled aqueous droplets, plays an important role in the formation of ice crystals within clouds. The efficiency of immersion freezing depends strongly on INP composition and, crucially, on the mixing state – how chemical species are distributed across the particle population. Here, we quantify the impact of aerosol mixing state on immersion freezing using a combined theoretical and particle-resolved modeling approach. We derive analytical expressions for the frozen fraction of internally and externally mixed INP populations based on classical nucleation theory, showing that the frozen fraction is sensitive to whether ice-active species are present in all particles or only in a subset of the population. We introduce a multi-species immersion freezing scheme into the particle-resolved model PartMC, using the water activity-based immersion freezing model (ABIFM) to compute freezing probabilities for mixed-composition particles. To improve computational efficiency, we implement a Binned Tau-Leaping algorithm and demonstrate an order-of-magnitude speedup with minimal accuracy loss. Simulations reproduce the analytical trends in limiting cases and extend the analysis to more general aerosol populations, where mixing state continues to exert a substantial control on frozen fraction. Sensitivity analyses across particle size, species type, and cooling condition reveal that the mixing state effect is most pronounced when small amounts of highly efficient INPs are mixed with less efficient materials. These findings underscore the need to represent aerosol mixing state explicitly in models of heterogeneous ice nucleation to reduce uncertainty in cloud-phase partitioning.

54 ENVIRONMENTAL SCIENCES

Machine learning the electric field response of condensed phase systems using perturbed neural network potentials

Abstract The interaction of condensed phase systems with external electric fields is of major importance in a myriad of processes in nature and technology, ranging from the field-directed motion of cells (galvanotaxis), to geochemistry and the formation of ice phases on planets, to field-directed chemical catalysis and energy storage and conversion systems including supercapacitors, batteries and solar cells. Molecular simulation in the presence of electric fields would give important atomistic insight into these processes but applications of the most accurate methods such as ab-initio molecular dynamics (AIMD) are limited in scope by their computational expense. Here we introduce Perturbed Neural Network Potential Molecular Dynamics (PNNP MD) to push back the accessible time and length scales of such simulations. We demonstrate that important dielectric properties of liquid water including the field-induced relaxation dynamics, the dielectric constant and the field-dependent IR spectrum can be machine learned up to surprisingly high field strengths of about 0.2 V Å −1 without loss in accuracy when compared to ab-initio molecular dynamics. This is remarkable because, in contrast to most previous approaches, the two neural networks on which PNNP MD is based are exclusively trained on molecular configurations sampled from zero-field MD simulations, demonstrating that the networks not only interpolate but also reliably extrapolate the field response. PNNP MD is based on rigorous theory yet it is simple, general, modular, and systematically improvable allowing us to obtain atomistic insight into the interaction of a wide range of condensed phase systems with external electric fields.