Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC SENSING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

137 records · Page 8

Three-state nematicity in the triangular lattice antiferromagnet Fe 1/3 NbS 2

Nematic order is the breaking of rotational symmetry in the presence of translational invariance. While originally defined in the context of liquid crystals, the concept of nematic order has arisen in crystalline matter with discrete rotational symmetry, most prominently in the tetragonal Fe-based superconductors where the parent state is four-fold symmetric. In this case the nematic director takes on only two directions, and the order parameter in such 'Ising-nematic' systems is a simple scalar. In this study, using a spatially resolved optical polarimetry technique, we show that a qualitatively distinct nematic state arises in the triangular lattice antiferromagnet Fe 1/3 NbS 2 . The crucial difference is that the nematic order on the triangular lattice is a Z 3 or three-state Potts-nematic order parameter. As a consequence, the anisotropy axes of response functions such as the resistivity tensor can be continuously reoriented by external perturbations. This discovery lays the groundwork for devices that exploit analogies with nematic liquid crystals.

36 MATERIALS SCIENCE↗

Imaging two-dimensional generalized Wigner crystals

The Wigner crystal has fascinated condensed matter physicists for nearly 90 years. Signatures of two-dimensional (2D) Wigner crystals were first observed in 2D electron gases under high magnetic field, and recently reported in transition metal dichalcogenide moiré superlattices. Direct observation of the 2D Wigner crystal lattice in real space, however, has remained an outstanding challenge. Conventional scanning tunnelling microscopy (STM) has sufficient spatial resolution but induces perturbations that can potentially alter this fragile state. Here we demonstrate real-space imaging of 2D Wigner crystals in WSe 2 /WS 2 moiré heterostructures using a specially designed non-invasive STM spectroscopy technique. This employs a graphene sensing layer held close to the WSe 2 /WS 2 moiré superlattice. Local STM tunnel current into the graphene layer is modulated by the underlying Wigner crystal electron lattice in the WSe 2 /WS 2 heterostructure. Different Wigner crystal lattice configurations at fractional electron fillings of n = 1/3, 1/2 and 2/3, where n is the electron number per site, are directly visualized. The n = 1/3 and n = 2/3 Wigner crystals exhibit triangular and honeycomb lattices, respectively, to minimize nearest-neighbour occupations. The n = 1/2 state spontaneously breaks the original C3 symmetry and forms a stripe phase. Here our study lays a solid foundation for understanding Wigner crystal states in WSe 2 /WS 2 moiré heterostructures and provides an approach that is generally applicable for imaging novel correlated electron lattices in other systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Creation of depth-confined, shallow nitrogen-vacancy centers in diamond with tunable density

Engineering shallow nitrogen-vacancy (NV) centers in diamond holds the key to unlocking new advances in nanoscale quantum sensing. We find that the creation of near-surface NVs through delta doping during diamond growth allows for tunable control over both NV depth confinement (with a twofold improvement relative to low-energy ion implantation) and NV density, ultimately resulting in highly sensitive single defects and ensembles with coherence limited by NV–NV interactions. Additionally, we demonstrate the utility of our shallow delta-doped NVs by imaging magnetism in few-layer CrSBr, a two-dimensional magnet. Here, we anticipate that the control afforded by near-surface delta doping will enable new developments in NV quantum sensing from nanoscale nuclear magnetic resonance to entanglement-enhanced metrology.

Chemical vapor deposition↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Colloquium: Ice rule and emergent frustration in particle ice and beyond

Geometric frustration and the ice rule are two concepts that are intimately connected and widespread across condensed matter. The first refers to the inability of a system to satisfy competing interactions in the presence of spatial constraints. The second, in its more general sense, represents a prescription for the minimization of the topological charges in a constrained system. Both can lead to manifolds of high susceptibility and nontrivial, constrained disorder where exotic behaviors can appear and even be designed deliberately. This Colloquium describes the emergence of geometric frustration and the ice rule in soft condensed matter. It excludes the extensive developments of mathematical physics within the field of geometric frustration, but rather focuses on systems of confined microscopic or mesoscopic particles that emerge as a novel paradigm exhibiting spin degrees of freedom. In such systems, geometric frustration can be engineered artificially by controlling the spatial topology and geometry of the lattice, the position of the individual particle units, or their relative filling fraction. These capabilities enable the creation of novel and exotic phases of matter and also potentially lead toward technological applications related to memory and logic devices that are based on the motion of topological defects. The rapid progress in theory and experiments is reviewed and the intimate physical connections with other frustrated systems at different length scales are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Lizard-inspired Tube Inspector (LTI) Robot

This final report summarizes the research findings of the current project. This project is a collaboration between New Mexico State University (NMSU) as a lead (Recipient) and Arizona State University (ASU) as a Co-Recipient. Tubular structures are common components of boilers and heat exchangers in power plants. Over time, these components may suffer corrosion, cracks, and stress-corrosion cracks in either the body or the welded connections. A single tube leakage can cause an outage of several weeks. Regular inspection is a key safety factor when ensuring that power plants are maintained in reliable, operational condition. This inspection, however, is challenging, time-consuming, and in many cases impossible due to accessibility issues and safety concerns. Recent developments in robotic-based inspection can offer a great solution. Hard-to-reach places can be inspected without overhauling the unit, saving time and cost. Although several robots have been designed and implemented successfully for inspecting power plant components, in particular tubular structures, their mobility and flexibility are limited. Most of these robots use wheels for mobility which reduces their maneuverability of these robots. Moreover, they usually use magnets to attach to tubes which will not work on tubes with non-ferromagnetic materials. These robots usually carry measurement tools for a particular non-destructive testing (NDT) method such as ultrasound testing (UT) that requires a couplant to perform a point-by-point (scanning) inspection of the tubular structure. In this project, we developed a versatile lizard-inspired tube inspector (LTI) robot with embedded inspection sensing components for tube inspection which removes the need for point-by-point scanning of tube surface for crack and corrosion detection. Inspired by a “lizard”, the novelty of the current project is the integration of couplant-free ultrasound sensing and transmission, advanced data-driven defect detection and imaging, and friction-based mechanical mobility components in a single robot to eliminate a need for smooth surfaces and simple geometry for mobility and scanning. The LTI robot could replace the wheel-based approach with friction-based mobility to significantly increase the flexibility and maneuverability of the robot. The LTI robot can get into a power plant unit, such as a boiler, from a small area allowing it to access a component of interest for inspection (e.g., move on OD, curved and flat surfaces, non-ferromagnetic or ferromagnetic materials, and tubes with rough surfaces and complex geometries). Additionally, an advanced data-driven method using ultrasound data was pioneered to allow the robot to detect defects in the entire area between the robot’s multi-functional mobility system (grippers). Integrating a couplant-free ultrasound sensing in the robot’s grippers as well as using advanced data-driven methods allowed the LTI to detect defects in the entire cross-section of a tube using its grippers when stationary and when mobile.

20 FOSSIL-FUELED POWER PLANTS↗

Dynamics of metastable contact soliton dissipative exchange flows in one-dimensional ferromagnetic channels

Dissipative exchange flows (DEFs) are large-amplitude boundary value solutions of ferromagnetic channels. In their low-injection limit, DEFs reduce to spin superfluids. However, in the strong injection limit, nonlinearities dominate close to the injection site and a soliton is formed; this solution has been termed a contact soliton dissipative exchange flow (CS-DEF). Here, in this work, we numerically investigate CS-DEF solutions in a moderate injection regime and a finite injection width. We find a solution where two metastable solitons coexist in the injection region. This solution is metastable in the sense that any perturbation to the system will eject one of the solitons out of the injection region. Moreover, soliton dynamics can be excited when two injection regions are separated by a certain distance. We find that the ensuing DEF between the solitons induces a steady-state dynamics in which metastable solitons are continually ejected and nucleated. Furthermore, and depending on the relative signs of the spin injections, the soliton dynamics possess a particular handedness and frequency related to the spin transfer torque delivered by the DEF. Our results provide insights into the transport of spin current by DEFs - where the interaction between DEFs and solitons suggests a mechanism for detaching contact-solitons from the injection boundary. Although this study focuses on the "nonlocal" interaction between solitons, it may lead to the investigation of new mechanisms for inserting solitons in a DEF, e.g., for discrete motion and transport of information over long distances.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-term persistence of infectious Zika virus: Inflammation and behavioral sequela in mice

The neurodevelopmental defects associated with ZIKV infections early in pregnancy are well documented, however the potential defects and long-term consequences associated with milder infections in late pregnancy and perinatal period are less well understood. To model these, we challenged 1 day old (P1) immunocompetent C57BL/6 mice with ZIKV. The animals developed a transient neurological syndrome including unsteady gait, kinetic tremors, severe ataxia and seizures 10–15 days post-infection (dpi) but symptoms subsided after a week, and most animals survived. Despite apparent recovery, MRI of convalescent mice show reduced cerebellar volume that correlates with altered coordination and motor function as well as hyperactivity and impulsivity. Persistent mRNA levels of pro-inflammatory genes including Cd80 , Il-1α , and Ifn-γ together with Cd3 , Cd8 and perforin ( PrfA) , suggested persistence of low-grade inflammation. Surprisingly, the brain parenchyma of convalescent mice harbor multiple small discrete foci with viral antigen, active apoptotic processes in neurons, and cellular infiltrates, surrounded by activated astrocytes and microglia as late as 1-year post-infection. Detection of negative-sense strand viral RNA and isolation of infectious virus derived from these convalescent mice by blinded passage in Vero cells confirmed long-term persistence of replicating ZIKV in CNS of convalescent mice. Although the infection appears to persist in defined reservoirs within CNS, the resulting inflammation could increase the risk of neurodegenerative disorders. This raises concern regarding possible long-term effects in asymptomatic children exposed to the virus and suggests that long-term neurological and behavioral monitoring as well as anti-viral treatment to clear virus from the CNS may be useful in patients exposed to ZIKV at an early age.

59 BASIC BIOLOGICAL SCIENCES↗

Use of Micro-Gravity Sensors for External Fluid Level Monitoring in Waste and Nuclear Related Applications - 20315

There are a number of applications in nuclear energy and hazardous waste disposal that require monitoring of fluids under extreme environments, including high levels of temperature, pressure, toxicity and radioactivity. Many of these applications will benefit from a monitoring technique that is external and non-invasive. Currently the sensors used are invasive, must reside inside the pressurized vessels and must penetrate the vessel walls, which can create a weakness in the vessel. Additionally, instruments that are used inside such containers must be exceptionally hardened to the environment. Information Systems Laboratories (ISL) has developed an external mass (gravimetric) measuring technique for monitoring nuclear coolant in Small Modular Reactors (SMRs), which will also work for measuring fluid levels in waste tanks, that avoids the problems inherent in invasive sensors. It utilizes a COTS gravitational sensor of unprecedented accuracy, leveraged via proper sensor placement geometry, to detect fluid changes of small amplitude from an outside position, obviating the need to penetrate the vessel. The technique is called Gravisense{sup TM}. ISL has proven via simulation and experiment that this concept can be usefully applied to monitoring fluid levels in both nuclear reactors and large waste tanks. Numerical simulation algorithms were developed to calculate the gravity effect of small changes in water level, which were verified by experiments at the NIST Physical Simulator facility at the Oregon State University. The measured ultralow noise levels of the superconducting gravimeter type which utilizes a Niobium sphere suspended in a magnetic field to attain its phenomenal accuracy, demonstrated that fluid levels in SMRs can be measured at least to within 3 cm. Furthermore, the method can distinguish between a contained leak (from reactor to containment vessel) from an external leak (from reactor to outside of containment). Additionally, simulations of waste canisters that hold spent fuel rods show that the fluid level measuring accuracy can potentially do better than 1 cm accuracy by measuring from below the vessel, and judicious placement of sensors on top of large waste tanks can potentially achieve a very impressive 2 mm measurement accuracy. These encouraging results prove that the Gravisense{sup TM} technique for fluid determination can be very useful in nuclear energy generation, testing, and research, as well as in waste monitoring situations that are difficult to monitor via traditional sensing technology. We believe that the next step should be to test the technique on canisters of the type that are currently storing waste in various DOE locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-dimensional spin systems in PECVD-grown diamond with tunable density and long coherence for enhanced quantum sensing and simulation

Systems of spins engineered with tunable density and reduced dimensionality enable a number of advancements in quantum sensing and simulation. Defects in diamond, such as nitrogen-vacancy (NV) centers and substitutional nitrogen (P1 centers), are particularly promising solid-state platforms to explore. However, the ability to controllably create coherent, two-dimensional spin systems and characterize their properties, such as density, depth confinement, and coherence, is an outstanding materials challenge. We present a refined approach to engineer dense (≳1 ppm ∙ nm), 2D nitrogen, and NV layers in diamond using delta-doping during plasma-enhanced chemical vapor deposition epitaxial growth. We employ both traditional materials techniques, e.g., secondary ion mass spectrometry, alongside NV spin decoherence-based measurements to characterize the density and dimensionality of the P1 and NV layers. We find P1 densities of 5–10 ppm ∙ nm, NV densities between 1 and 3.5 ppm ∙ nm tuned via electron irradiation dosage, and depth confinement of the spin layer down to 1.6 nm. We also observe high (up to 0.74) ratios of NV to P1 centers and reproducibly long NV coherence times, dominated by dipolar interactions with the engineered P1 and NV spin baths.

36 MATERIALS SCIENCE↗