Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Kaon–proton strong interaction at low relative momentum via femtoscopy in Pb–Pb collisions at the LHC

In quantum scattering processes between two particles, aspects characterizing the strong and Coulomb forces can be observed in kinematic distributions of the particle pairs. The sensitivity to the interaction potential reaches a maximum at low relative momentum and vanishing distance between the two particles. Ultrarelativistic heavy-ion collisions at the LHC provide an abundant source of many hadron species and can be employed as a measurement method of scattering parameters that is complementary to scattering experiments. This study confirms that momentum correlations of particles produced in Pb–Pb collisions at the LHC provide an accurate measurement of kaon–proton scattering parameters at low relative momentum, allowing precise access to the K – p $\rightarrow$ K – p process. This work also validates the femtoscopic measurement in ultrarelativistic heavy-ion collisions as an alternative to scattering experiments and a complementary tool to the study of exotic atoms with comparable precision. In this work, the first femtoscopic measurement of momentum correlations of K – p (K + $\bar{p}$) and K + p (K – $\bar{p}$) pairs in Pb–Pb collisions at centre-of-mass energy per nucleon pair of $\sqrt{s_{NN}}$ =5.02 TeV registered by the ALICE experiment is reported. The components of the K – p complex scattering length are extracted and found to be $\mathfrak{R}$f 0 = -0.91±0.03(stat)$^{+0.17}_{-0.03}$(syst) and $\mathfrak{T}$f 0 =0.92±0.05(stat)$^{+0.12}_{-0.33}$(syst). The results are compared with chiral effective field theory predictions as well as with existing data from dedicated scattering and exotic kaonic atom experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Facile Approach to High Precision Detection of Cell-to-Cell Variation for Li-ion Batteries

Abstract Over the past decade, it has been repeatedly demonstrated that homogeneity in electrochemical performance of lithium-ion cells plays a major role in determining the life and safety of lithium-ion battery modules or packs. Generally, the homogeneity of a battery pack is evaluated by characterizing the cells individually in terms of capacity, mass, impedance. Particularly, high quality electrochemical data heavily relies on the availability of high precision current source to minimize the discrepancy induced by the channel-to-channel variation. Here, a facile and precise measurement method is reported for screening cell-to-cell variations, in which voltage is the only indicator parameter independent of high precision current source. In detail, by connecting the cells in series (CiS), the measurement error of electrochemical data caused by stability and discrepancy of current sources among different charge/discharge equipment can be effectively avoided. The findings of this work showed that the cell-to-cell variations can be simply and sensitively detected with CiS configuration. For example, the relative standard deviation, which is the evaluation criterion of battery homogeneity, was 2.14% based on CiS while it was 0.43% based on individual measurements. The simple and precise CiS measurement is promising for evaluation of cell quality or module integration quality. In addition, this work can also provide a solid foundation for the development of detection algorithms for battery management systems to rapidly monitor battery homogeneity.

25 ENERGY STORAGE↗

LEAKAGE CHARACTERISTICS OF A STEPPED BALANCE PISTON LABYRINTH SEAL IN SUPERCRITICAL CO2

In an integrally geared compressor, there is a net thrust load on the pinion shaft from gear loads and aerodynamic forces. The net thrust on the pinion is resolved with either a thrust bearing or a thrust collar (rider ring). As the pressure increases, this increases the aerodynamic force proportionally. In highpressure systems this can overwhelm the thrust bearing or thrust collar if thrust is mismanaged. In a recent test program for an sCO2 integrally geared compander (compressor/turbine), a balance piston was created on the opposite end of the turbine to provide an equalizing thrust; while this is not novel, the balance piston provided a test apparatus for measuring the leakage on a 20 tooth stepped labyrinth seal operating at pressures in excess of 250 bar (3600 psi). The stepped balance piston seal is a 20 tooth tooth-onrotor balance piston seal. This type of seal was selected since it was predicted to have substantially less leakage than a comparably sized straight through labyrinth seal. Comparisons between the two designs will be made, showing that the leakage of the stepped balance piston seal is considerably lower. The tooth clearance on the seal was selected to be 30 mils radial. While this seems large, a stack-up tolerance assessment showed that this magnitude of clearance was appropriate to prevent rotor stator contact. During the testing campaign, data was recorded showing the leakage across this stepped balance piston seal at pressures in excess of 250 bar (3600 psi) with a pressure ratio of 2. This leakage data was measured, and will be compared to leakage data predicted with CFD. Two measurement methods are presented for the stepped balance piston seal: an orifice plate and valve. The predicted seal leakage from a straight through seal was four times that of the predicted stepped labyrinth seal. The measured flow from the stepped seal was on the same order as the CFD prediction and offered adequate rotordynamic performance

wilkes, jason↗

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP↗

pnnl/openstudio-building-energy-standard-measures-gem

The OpenStudio Building Energy Standards Measure Repository is a comprehensive collection of innovative OpenStudio measures designed to facilitate energy code analysis. OpenStudio is a cutting-edge platform brings together physics-based building energy modeling (BEM), BEM process automation, and large-scale computing capabilities. Contains OpenStudio Standards Performance Rating Method Measure (IPID 32936) and OpenStudio Measure to Generate IPLV-specific Chiller Performance Curves for Chillers (IPID 32940)

Xu, Weili [PNNL]↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Performance of optical sensors for cloud measurements deployed by the ARM Aerial Facility during ACE-ENA

During the Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA), a variety of in situ optical sensors using shadow imaging, scattering and holography were deployed by the Atmospheric Radiation Measurement (ARM) Aerial Facility to determine cloud properties. Taking advantage of the wide, overlapping range of instrumentation, we compare in situ cloud data from several different measurement methods for droplets up to 100 µm. Further, data processing was tailored to the encountered conditions, leading to good agreement. Improvements include noise reduction for holography and better out-of-focus correction for shadow imaging. Comparison between direct liquid water content measurements and optical sensors showed better agreement at higher droplet number concentrations (>120/cm 3 ).

47 OTHER INSTRUMENTATION↗

Discrepancy quantification between experimental and simulated data of CO 2 adsorption isotherm using hierarchical Bayesian estimation

Here, to quantitatively analyze the inconsistencies commonly observed between experimental and simulated adsorption isotherms, parameter estimation of adsorption isotherm models was conducted by hierarchical Bayesian estimation with parameter uncertainties being quantified as probability distributions. The estimation method was implemented using Markov Chain Monte Carlo (MCMC) to analyze multiple data sets obtained from different sources, including a publicly available database. To describe the discrepancies of experimental and simulated adsorption data, the simulation data was set as the reference to which experimental measurements were compared. We applied the proposed approach to analyze CO 2 adsorption isotherms that are measured and simulated on zeolite 13X and MIL-101(Cr). In these case studies, the discrepancy of CO 2 adsorption isotherm was successfully quantified between experimental measurements and predictions given by molecular simulations using Grand Canonical Monte Carlo (GCMC), where uncertainties were quantified as probability distributions. Furthermore, experimental data sets that agree well with the GCMC simulation have been identified, providing insights into experimental and measurement methods as well as choosing the right assumptions in the molecular simulation.

42 ENGINEERING↗

Effects of cosine tapering window on quantum phase estimation

Here, we provide a modification to the quantum phase estimation algorithm (QPEA) [Abrams and Lloyd, Phys. Rev. Lett. 83, 5162 (1999); Cleve et al., Proc. R. Soc. A 454, 339 (1998); Nielsen and Chuang, Quantum computation and quantum information, 2002.] inspired by classical windowing methods for spectral density estimation. From this modification we obtain an upper bound in the cost that implies a cubic improvement with respect to the algorithm's error rate. Numerical evaluation of the costs also demonstrates an improvement. Moreover, with similar techniques, we detail an iterative projective measurement method for ground state preparation that gives an exponential improvement over previous bounds using QPEA. Numerical tests that confirm the expected scaling behavior are also obtained. For these numerical tests we have used a lattice Thirring model as testing ground. Using well-known perturbation theory results, we also show how to more appropriately estimate the cost scaling with respect to state error instead of evolution operator error.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing Interactions between Adsorbed Polymers and γ-Al 2 O 3 Using Solid-State NMR

The interactions between polymers and metal oxide surfaces affect the physical properties of polymer composites and the selectivity of catalysts used for plastic conversion. Gauging the strengths of these interactions and how they depend on adsorption conformations and polymer structure is nevertheless quite challenging. Herein, we evaluate whether a recently introduced dynamic nuclear polarization-based surface-to-atom distance measurement method can be used to gauge the specific interactions between five vinyl polymers and an oxide support (alumina). The adsorption conformations of polymer monolayers were studied using site-specific 13 C{ 27 Al} rotational-echo saturation-pulse double-resonance (RESPDOR) experiments. The method is effective in revealing the average distance between the adsorbed polymer and the surface, as well as the fraction of the monomers that are adsorbed. Polymers that possess larger side chains are more weakly adsorbed, as evidenced by their formation of more numerous loop and tail structures. In conclusion, the measured RESPDOR dephasing data further reveals that polymer adsorption conformations are largely disordered and involve few hydrogen bonding interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic Qubit Characterization and Gate Optimization with QubiC

As the size and complexity of a quantum computer increases, quantum bit (qubit) characterization and gate optimization become complex and time-consuming tasks. Current calibration techniques require complicated and verbose measurements to tune up qubits and gates, which cannot easily expand to the large-scale quantum systems. We develop a concise and automatic calibration protocol to characterize qubits and optimize gates using QubiC, which is an open source FPGA (field-programmable gate array) based control and measurement system for superconducting quantum information processors. We propose multi-dimensional loss-based optimization of single-qubit gates and full XY-plane measurement method for the two-qubit CNOT gate calibration. We demonstrate the QubiC automatic calibration protocols are capable of delivering high-fidelity gates on the state-of-the-art transmon-type processor operating at the Advanced Quantum Testbed at Lawrence Berkeley National Laboratory. Finally, the single-qubit and two-qubit Clifford gate infidelities measured by randomized benchmarking are of 4.9(1.1) × 10 -4 and 1.4(3) × 10 -2 , respectively.

97 MATHEMATICS AND COMPUTING↗

Soil gas probes for monitoring trace gas messengers of microbial activity

Abstract Soil microbes vigorously produce and consume gases that reflect active soil biogeochemical processes. Soil gas measurements are therefore a powerful tool to monitor microbial activity. Yet, the majority of soil gases lack non-disruptive subsurface measurement methods at spatiotemporal scales relevant to microbial processes and soil structure. To address this need, we developed a soil gas sampling system that uses novel diffusive soil probes and sample transfer approaches for high-resolution sampling from discrete subsurface regions. Probe sampling requires transferring soil gas samples to above-ground gas analyzers where concentrations and isotopologues are measured. Obtaining representative soil gas samples has historically required balancing disruption to soil gas composition with measurement frequency and analyzer volume demand. These considerations have limited attempts to quantify trace gas spatial concentration gradients and heterogeneity at scales relevant to the soil microbiome. Here, we describe our new flexible diffusive probe sampling system integrated with a modified, reduced volume trace gas analyzer and demonstrate its application for subsurface monitoring of biogeochemical cycling of nitrous oxide (N 2 O) and its site-specific isotopologues, methane, carbon dioxide, and nitric oxide in controlled soil columns. The sampling system observed reproducible responses of soil gas concentrations to manipulations of soil nutrients and redox state, providing a new window into the microbial response to these key environmental forcings. Using site-specific N 2 O isotopologues as indicators of microbial processes, we constrain the dynamics of in situ microbial activity. Unlocking trace gas messengers of microbial activity will complement -omics approaches, challenge subsurface models, and improve understanding of soil heterogeneity to disentangle interactive processes in the subsurface biome.

04 OIL SHALES AND TAR SANDS↗

Developing the S 32 ( p , d ) S * 31 ( p ) ( γ ) reaction to probe the P 30 ( p , γ ) S 31 reaction rate in classical novae

Background: The 30 P(p,γ) 31 S reaction rate is one of the largest remaining sources of uncertainty in the final abundances of nuclei created in a classical nova involving a ONe white dwarf. The reaction rate directly influences silicon isotopic ratios, which are used as identifiers of presolar grains with nova origins. Additionally, the uncertainty in the 30 P(p,γ) 31 S reaction rate has been found to limit the use of nova nuclear thermometers based on observations of elemental ratios in nova ejecta. Purpose: Reduce uncertainties in the nuclear data for proton-unbound states in 31 S, which act as resonances for the 30 P(p,γ) 31 S reaction at classical nova temperatures, and develop a technique for high efficiency, high-resolution reaction-decay coincidence measurements. Methods: Here, the 32 S(p,d) 31 S reaction was used to populate the states of interest in 31 S. The experiment was performed at the Texas A&M Cyclotron Institute using the LLNL Hyperion array for the detection of charged particles and γ rays. A downstream silicon telescope was used to select reaction deuterons, and a single upstream silicon detector was used to measure protons emitted in the decay of unbound 31 S levels. Results: Several states in 31 S above the proton separation energy were observed to have been populated. Decay protons from the resonant states in 31 S were identified as events in the upstream silicon detectors that came in coincidence with deuterons in the downstream telescope. Protons emitted from these states were measured and branching ratios extracted. Conclusions: While no new reaction rate is derived, spin-parity assignments for several higher-lying proton unbound states have been confirmed. Measured p 0 branching ratios for these levels have been compared to previous measurements with good agreement, and in some cases provided a reduction in uncertainty. The previously identified T = 3/2 state may have been incorrectly assigned a large p 0 branching ratio in a previous measurement. The technique of measuring reaction-decay coincidences with a particle-gamma setup appears promising.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Second-harmonic signature of chiral spin structures in W/Pt/Co heterostructures with tunable magnetic anisotropy

Abstract Second-harmonic Hall voltage (SHV) measurement method has been widely used to characterize the strengths of spin–orbit torques (SOTs) in heavy metal/ferromagnet thin films saturated in the single-domain regime. Here, we show that the magnetic anisotropy of a W/Pt/Co trilayer can be robustly tuned from in-plane to out-of-plane by varying W, Pt, or Co thicknesses. Moreover, in samples with easy-cone anisotropy, SHV measurements exhibit anomalous ‘humps’ in the multidomain regime accessed by applying a nearly out-of-plane external magnetic field. These hump features can only be explained as a result of the formation of Néel-type domain walls, efficiently driven by nevertheless small SOTs in this double heavy metal heterostructure with canceling spin Hall angles.

Physics↗

Spatial Resolution of a microCT Scanner

We have measured the spatial resolution of the 450 kV test-bed microCT scanner. We have also modeled the resolution analytically. The model and measurement show correspondence within 5%. Our measurement method was to use a thin tungsten wire to act as an impulse function. Therefore, the image is the impulse response, also called the point spread function (PSF) of the system. The Fourier transform (FT) of the impulse response is the modulation transfer function (MTF) of the system. We report the MTF here. By moving the wire at different positions in the scan field of view (FOV), we can measure MTF at different positions in the FOV. Since our imaging system is radially symmetric, we report MTF in two directions, radial and tangential as shown in Figure 1. The radial direction is along the line from isocenter to the wire, and the tangential is perpendicular to it.

42 ENGINEERING↗