Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microwave sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum metrology of low frequency electromagnetic modes with frequency upconverters

We describe the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) (≲300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band (~ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. The RQU can operate as a quantum-limited op-amp, or use protocols from optomechanics to implement non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. Furthermore, these protocols enable experiments using dc-VHF electromagnetic modes as quantum sensors.

Kuenstner, Stephen E.↗

Thunderstorm Cloud-Type Classification from Space-Based Lightning Imagers

The organization and structure of thunderstorms determines the extent and severity of their hazards to the general public and their consequences for the Earth system. Distinguishing vigorous convective regions that produce heavy rain and hail from adjacent regions of stratiform clouds or overhanging anvil clouds that produce light to no rainfall is valuable in operations and physical research. Cloud-type algorithms that partition convection from stratiform regions have been developed for space-based radar, passive microwave, and now Geostationary Operational Environmental Satellites (GOES) Advanced Baseline Imager (ABI) multispectral products. However, there are limitations for each of these products including temporal availability, spatial coverage, and the degree to which they based on cloud microphysics. We report we have developed a cloud-type algorithm for GOES Geostationary Lightning Mapper (GLM) observations that identifies convective/nonconvective regions in thunderstorms based on signatures of interactions with nonconvective charge structures in the lightning flash data. The GLM sensor permits a rapid (20 s) update cycle over the combined GOES-16–GOES-17 domain across all hours of the day. Storm regions that do not produce lightning will not be classified by our algorithm, however. The GLM cloud-type product is intended to provide situational awareness of electrified nonconvective clouds and to complement other cloud-type retrievals by providing a contemporary assessment tied to lightning physics. We propose that a future combined ABI–GLM cloud-type algorithm would be a valuable product that could draw from the strengths of each instrument and approach.

54 ENVIRONMENTAL SCIENCES↗

The Simons Observatory: Design, Integration, and Testing of the Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of σ(r) = 0.002, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35° field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and <0.1 K focal plane that holds >12,000 transition edge sensor detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for Color Center Preserving Hydrogen‐Termination of Diamond

Abstract Chemical functionalization of diamond surfaces by hydrogen is an important method for controlling the charge state of near‐surface fluorescent color centers, an essential process in fabricating devices such as diamond field‐effect transistors and chemical sensors, and a required first step for realizing families of more complex terminations through subsequent chemical processing. In all these cases, termination is typically achieved using hydrogen plasma sources that can etch or damage the diamond, as well as deposited materials or embedded color centers. This work explores alternative methods for lower‐damage hydrogenation of diamond surfaces, specifically the annealing of diamond samples in high‐purity, non‐explosive mixtures of nitrogen and hydrogen gas, and the exposure of samples to microwave hydrogen plasmas in the absence of intentional stage heating. The effectiveness of these methods are characterized by x‐ray photoelectron spectroscopy (XPS), and comparison of the results to density‐functional modelling of the surface hydrogenation energetics implicates surface oxygen ligands as the primary factor limiting the termination quality of annealed samples. Finally, photoluminescence (PL) spectroscopy is used to verify that both the annealing and reduced sample temperature plasma methods are non‐destructive to near‐surface ensembles of nitrogen‐vacancy (NV) centers, in stark contrast to plasma treatments that use heated sample stages.

36 MATERIALS SCIENCE↗

ac Sensing Using Nitrogen-Vacancy Centers in a Diamond Anvil Cell up to 6 GPa

Nitrogen-vacancy color centers in diamond have attracted broad attention as quantum sensors for both static and dynamic magnetic, electrical, strain, and thermal fields and are particularly attractive for quantum sensing under pressure in diamond anvil cells. Optically based nuclear magnetic resonance may be possible at pressures greater than a few gigapascals and offers an attractive alternative to conventional Faraday-induction-based detection. In this work, we present ac sensing results and demonstrate synchronized readout up to 6 GPa but find that the sensitivity is reduced due to inhomogeneities of the microwave field and pressure within the sample space. These experiments enable the possibility of all-optical high resolution magnetic resonance of nanoliter sample volumes at high pressures.

58 GEOSCIENCES↗

Low-phase-noise surface-acoustic-wave oscillator using an edge mode of a phononic band gap

Low-phase-noise microwave-frequency integrated oscillators provide compact solutions for various applications in signal processing, communications, and sensing. Surface acoustic waves (SAWs), featuring orders-of-magnitude shorter wavelength than electromagnetic waves at the same frequency, enable integrated microwave-frequency systems with much smaller footprint on chip. SAW devices also allow higher-quality (Q) factors than electronic components at room temperature. Here, we demonstrate a low-phase-noise gigahertz-frequency SAW oscillator on 128°Y-cut lithium niobate, where the SAW resonator occupies a footprint of 0.05 mm 2 . Leveraging phononic crystal band-gap-edge modes to balance between Q factors and insertion losses, our 1-GHz SAW oscillator features a low phase noise of -132.5 dBc/Hz at a 10-kHz offset frequency and an overlapping Hadamard deviation of 6.5 × 10 -10 at an analysis time of 64 ms. The SAW resonator-based oscillator holds high potential in developing low-noise sensors and acousto-optic integrated circuits.

42 ENGINEERING↗

Coherent Magnon–Photon Coupling in the Magnetic Semiconductor CrSBr

Magnon-based hybrid quantum systems are promising candidates for quantum interconnects and quantum sensors, and they offer a rich platform for exploring nonlinear magnonics and cavity–photon interactions. Two-dimensional (2D) van der Waals magnets provide a compact, atomically flat geometry that can be easily integrated into existing quantum circuits, such as superconducting resonators and qubits. Among various 2D magnets, the magnetic semiconductor CrSBr is particularly unique due to its strong spin–exciton, spin–lattice, and magnon–exciton interactions. In this work, we demonstrate coherent coupling between antiferromagnetic (AFM) magnons in CrSBr and microwave photons in a niobium-(Nb)-based-on-chip resonator. We tuned the magnon–photon coupling strength by changing the number of CrSBr flakes integrated into the Nb microwave photon resonators. Furthermore, this work demonstrates the first step toward integrating layered van der Waals 2D magnets into superconducting microwave circuits, with full access for microwave and optical probing.

Electromagnetic radiation↗

Long-baseline quantum sensor network as dark matter haloscope

Ultralight dark photons constitute a well-motivated candidate for dark matter. A coherent electromagnetic wave is expected to be induced by dark photons when coupled with Standard-Model photons through kinetic mixing mechanism, and should be spatially correlated within the de Broglie wavelength of dark photons. Here we report the first search for correlated dark-photon signals using a long-baseline network of 15 atomic magnetometers, which are situated in two separated meter-scale shield rooms with a distance of about 1700 km. Both the network’s multiple sensors and the shields large size significantly enhance the expected dark-photon electromagnetic signals, and long-baseline measurements confidently reduce many local noise sources. Using this network, we constrain the kinetic mixing coefficient of dark photon dark matter over the mass range 4.1 feV-2.1 peV, which represents the most stringent constraints derived from any terrestrial experiments operating over the aforementioned mass range. Our prospect indicates that future data releases may go beyond the astrophysical constraints from the cosmic microwave background and the plasma heating.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Carbon Fiber and Polymer Composites

Tooling is an integral part of composites manufacturing. Composite tools, also called ‘soft’ tools, are more easily constructed than ‘hard’ metal tools and, because they are made from materials similar to the manufactured composite part, they can be made in-house and have a good co-efficient of thermal expansion match. However, as the ‘soft’ designation suggests, they are more vulnerable to wear and typically find application in relatively low-volume production. Additive manufacturing of thermoplastics has proven to be a lucrative option that can help improve the tooling functionalities, as it offers more design flexibility. Owing to the inherent nature of additive manufacturing, the possibility of printing sensors within the tool material and at proximity to otherwise inaccessible areas of the tool become a reality. Continuous carbon fiber (CCF)-reinforced three-dimensional (3D) printing of engineering thermoplastics has proven to be a viable option to strengthen a part well beyond the ideal moduli of unmodified thermoplastic. Furthermore, adding nanotubes or graphene to the thermoplastic matrix will also improve both the thermal conductivity and interlaminar shear strength within the tool. Carbon nanotubes (CNTs) and carbon fibers (CFs) are microwave susceptors; exploiting the physics of Joule heating to increase the energy efficiency of tool hardening and cure rates is a core goal of this project. Because of the rapid volumetric heating enabled by the absorption of microwave or radio frequency energy and electromagnetic (EM) annealing presents an attractive opportunity to significantly reduce manufacturing cycle times while improving part performance.

Craps, Matthew G.↗

An Algorithm to Retrieve Total Precipitable Water Vapor in the Atmosphere from FengYun 3D Medium Resolution Spectral Imager 2 (FY-3D MERSI-2) Data

The atmosphere has substantial effects on optical remote sensing imagery of the Earth&rsquo;s surface from space. These effects come through the functioning of atmospheric particles on the radiometric transfer from the Earth&rsquo;s surface through the atmosphere to the sensor in space. Precipitable water vapor (PWV), CO 2 , ozone, and aerosol in the atmosphere are very important among the particles through their functioning. This study presented an algorithm to retrieve total PWV from the Chinese second-generation polar-orbiting meteorological satellite FengYun 3D Medium Resolution Spectral Imager 2 (FY-3D MERSI-2) data, which have three near-infrared (NIR) water vapor absorbing channels, i.e., channel 16, 17, and 18. The algorithm was improved from the radiance ratio technique initially developed for Moderate-Resolution Imaging Spectroradiometer (MODIS) data. MODTRAN 5 was used to simulate the process of radiant transfer from the ground surfaces to the sensor at various atmospheric conditions for estimation of the coefficients of ratio technique, which was achieved through statistical regression analysis between the simulated radiance and transmittance values for FY-3D MERSI-2 NIR channels. The algorithm was then constructed as a linear combination of the three-water vapor absorbing channels of FY-3D MERSI-2. Measurements from two ground-based reference datasets were used to validate the algorithm: the sun photometer measurements of Aerosol Robotic Network (AERONET) and the microwave radiometer measurements of Energy&rsquo;s Atmospheric Radiation Measurement Program (ARMP). The validation results showed that the algorithm performs very well when compared with the ground-based reference datasets. The estimated PWV values come with root mean square error (RMSE) of 0.28 g/cm 2 for the ARMP and 0.26 g/cm 2 for the AERONET datasets, with bias of 0.072 g/cm 2 and 0.096 g/cm 2 for the two reference datasets, respectively. The accuracy of the proposed algorithm revealed a better consistency with ground-based reference datasets. Thus, the proposed algorithm could be used as an alternative to retrieve PWV from FY-3D MERSI-2 data for various remote sensing applications such as agricultural monitoring, climate change, hydrologic cycle, and so on at various regional and global scales.

54 ENVIRONMENTAL SCIENCES↗

A fluorescent-protein spin qubit

Quantum bits (qubits) are two-level quantum systems that support initialization, readout and coherent control1. Optically addressable spin qubits form the foundation of an emerging generation of nanoscale sensors. The engineering of these qubits has mainly focused on solid-state systems. However, fluorescent proteins, rather than exogenous fluorescent probes, have become the gold standard for in vivo microscopy because of their genetic encodability. Although fluorescent proteins possess a metastable triplet state, they have not been investigated as qubits. Here we realize an optically addressable spin qubit in enhanced yellow fluorescent protein. A near-infrared laser pulse enables triggered readout of the triplet state with up to 20% spin contrast. Using coherent microwave control of the enhanced-yellow-fluorescent-protein spin at liquid-nitrogen temperatures, we measure a (16 ± 2) μs coherence time under Carr–Purcell–Meiboom–Gill decoupling. We express the qubit in mammalian cells, maintaining contrast and coherent control despite the complex intracellular environment. Finally, we demonstrate optically detected magnetic resonance in bacterial cells at room temperature with contrast up to 8%. Our results introduce fluorescent proteins as a powerful qubit platform that paves the way for applications in the life sciences, such as nanoscale field sensing and spin-based imaging modalities.

Feder, Jacob S. [Univ. of Chicago, IL (United Stat↗

Simulating the Phonon Collection Efficiency in Kinetic Inductance Phonon-Mediated Detectors

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for two existing detector architectures to study phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements.

Dang, Stella Q.↗

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors are superconducting microcalorimeters that use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the device substrate. In order to improve the design of these detectors, we need to understand the effect of various detector design elements on the physical processes that take place within the detector through simulation efforts. One figure of merit for KIPM detectors is the phonon collection efficiency, $\eta_{ph]$, defined as the ratio of phonon energy detected by the sensitive element in the detector and the energy deposited by incident phonons in the substrate. Comparing the phonon collection efficiency obtained in simulation and in experiment for the same detector geometry provides insight to physical processes in the detector, such as phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements. This work models the phonon collection efficiency in two KIPM detectors with different geometries, one located at the Fermi National Accelerator Laboraory, the other located at the SLAC National Accelerator Laboratory.

Dang, Stella Q.↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Searching for Dark Matter with Superconducting Qubits

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required.In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 x 10-15 in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NWB Sensors Infrared Cloud Imager Data Products from SGP

NWB Sensors is a company which has developed a commercially available Infrared Cloud Imager (ICI). For more information, consult the company's webpage, https://www.nwbsensors.com/infrared-cloud-imager. To validate the radiometric accuracy of the ICI, NWB Sensors deployed it to the ARM SGP User Facility in 2023. The primary motivation of this deployment was to perform an intercomparison between the ICI and the Atmospheric Emitted Radiance Interferometer (AERI). The AERI spectral radiance data product can be integrated across the response function of the ICI and directly compared to the zenith radiance observed by the ICI. In addition, the ICI uses proprietary models of the downwelling clear-sky radiance in its cloud processing algorithms. They are based on surface meteorology and precipitable water vapor (PWV). These models were validated by comparing their predicted radiances to those derived from radiative transfer models of the ARM radiosondes. Finally, PWV observations derived from the ICI's onboard GNSS-based PWV retrieval system were compared against those from the microwave radiometer. This dataset contains the ICI radiance and cloud data products.

Atmosphere↗