Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Safeguards for the Lithium Fluoride Thorium Reactor: A Preliminary Nuclear Material Control and Accounting Assessment

This report was prepared by Oak Ridge National Laboratory (ORNL) for Flibe Energy Inc. (FEI), a US-based advanced reactor company founded in 2011 and headquartered in Huntsville, Alabama. FEI is developing the lithium-fluoride thorium reactor (LFTR), which is a modern two-fluid molten salt reactor (MSR) design operating on a thorium/ 233 U fuel cycle. FEI intends for LFTR to become a self-sustaining clean energy source that can create or breed its own fuel from thorium. Each LFTR is intended to breed enough fissile material to compensate for the amount it consumes. Consequently it would not require fissile replenishment during its operational lifetime. This self-sustaining nature would eliminate the need for uranium enrichment infrastructure to support LFTRs after the first generation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A new capability facilitating nuclear materials research: the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML), located in the Long Beamline Building (LBB) of the Advanced Photon Source (APS) of Argonne National Laboratory (ANL), serves as a centralized radiological facility for preparing radioactive samples for APS beamline experiments. The AML is equipped to receive shipments, handle open-form radioactive materials, encapsulate samples, and transport samples to-and-from beamline end-stations. The AML works closely with users and the APS radiological safety committee to make sure the safe conduct of experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Development of metallic nuclear material purification process via simultaneous chlorination and volatilization

Here, a purification process involving simultaneous chlorination and volatilization is reported using aluminum, iron, gallium, and uranium separation from cerium metal as the demonstration system. Anhydrous Cl 2 gas was reacted with the metal after it had been converted to small particles of hydride at temperatures ranging from 523 to 973 K. Each of the impurities should form chlorides with relatively high saturated vapor pressures. The objective of the process was to volatilize these chlorides after first achieving near-complete conversion of the metals to hydride and then chlorides. Complete conversion of hydrides to chlorides could not be achieved using relatively low-grade (99.5%) Cl 2 . High decontamination factors for all of the metal impurities required near complete conversion to chloride. It was concluded that oxygen contamination of the feed gas stream likely limits the conversion to chlorides by forming oxides instead, which then limits the volatilization of contaminants. Uranium was particularly challenging to remove in experiments suspected of having high oxygen contamination in the feed gas stream. After switching to ultra-high purity (99.999%) Cl 2 , complete conversion to chlorides within the measurement error was possible for the entire temperature range studied. Decontamination factors for aluminum, iron, gallium, and uranium were found to have average values of 1.9, 9.8, 14, and 5, respectively, at 973 K. While the process was most extensively studied using a once-through gas flow, recycling unreacted Cl 2 gas succeeded at minimizing waste while still maintaining complete conversion and similar decontamination factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Spectroscopy Characterization of Nuclear Materials and Soot from High Explosives

Vibrational and luminescence spectroscopy were used in the investigation of U and Pu-bearing compounds and soot from high explosives testing. Key spectroscopic signatures of UF4 and its hydrates, PuO 2 , and soot from different explosives will be presented. The United States Government retains and the publisher, by accepting this article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this work, or allow others to do so, for United States Government purposes.

Villa-Aleman, Eliel↗

SRNL Nuclear Material Management Strategy

Started in FY22 to categorize with the goal of determining assets and liabilities for the new management team and reducing SRNL’s excess inventory. • Allow for program growth within the current material limits. • Prior to FY22 inventory was a ‘blackbox’. • No formal system for tracking utilization or future needs until items arrived. • Created friction between management and researchers • Slowed down incoming projects • Risk of breaking safety and/or security limits • Risk of jepardizing program growth.

Ramsey, Catherine M.↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗