Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear physics instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TexAT detector upgrade for 14 O($α$, $p$) 17 F cross section measurement

A direct cross-section measurement of the 14 O($α$, $p$) 17 F reaction is important to understand the light curves of x-ray bursts. The measurement will be performed using the Texas Active Target TPC version 2 (TexAT_v2). The TexAT_v2 aims at measuring lower energy protons from the reaction than the original TexAT. Newly developed silicon and CsI(Tl) detector arrays are added at the left, right and bottom of a modified field cage to increase its detection efficiency. Furthermore, this paper describes the overall specifications and two commissioning experiments performed at Texas A&M University.

14O(α, p)17F↗

The cyclotron gas stopper at FRIB getting ready for operations

Linear gas stopping cells have been used for nearly two decades to slow down projectile fragments at the National Superconducting Cyclotron Laboratory, now the Facility for Rare Isotope Beams, for experiments with low-energy and reaccelerated beams. In order to efficiently stop and rapidly extract light to medium-mass fast ions, a cyclotron gas-stopper has been constructed. It uses a cyclotron-type magnet and a helium-gas filled stopping chamber to slow down the injected beam. RF ion guides transport the stopped ions to the center of the magnet and axially through the bore before acceleration to <60 keV. Following successful offline tests, the cyclotron stopper was moved to an experimental vault and connected to a new momentum–compression beam line. Beam transport to and into the cyclotron stopper was tested with stable beams. Finally, using 46 K fragments, the first successful stopping and extraction of a high-energy beam with the cyclotron stopper was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A physical unclonable neutron sensor for nuclear arms control inspections

Abstract Classical sensor security relies on cryptographic algorithms executed on trusted hardware. This approach has significant shortcomings, however. Hardware can be manipulated, including below transistor level, and cryptographic keys are at risk of extraction attacks. A further weakness is that sensor media themselves are assumed to be trusted, and any authentication and encryption is done ex situ and a posteriori. Here we propose and demonstrate a different approach to sensor security that does not rely on classical cryptography and trusted electronics. We designed passive sensor media that inherently produce secure and trustworthy data, and whose honest and non-malicious nature can be easily established. As a proof-of-concept, we manufactured and characterized the properties of non-electronic, physical unclonable, optically complex media sensitive to neutrons for use in a high-security scenario: the inspection of a military facility to confirm the absence or presence of nuclear weapons and fissile materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Accelerator Technologies and Science: Progress and Outlook

For over half a century, high-energy particle accelerators play a key role and shape modern nuclear and particle physics, they are also the instruments at the forefront of research for material science and biology. The physics needs continuously push us to invent novel ways to increase energy and improve the performance of accelerators, reduce their cost and make them more power-efficient. Here we briefly overview the most notable accelerator facilities which recently became operational and are now employed for research in nuclear physics, basic energy sciences, neutrinos, high energy particle frontier. We also present upcoming and planned future facilities and outline their main goals, challenges, and required R&D. Focus will be given to the core accelerator technologies such as magnets, RF acceleration, and targets as we as leading beam physics developments such as beam cooling, colliding beams and plasma acceleration.

Shiltsev, Vladimir D.↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and Plan of DUNE at Fermilab

The discovery and the solid confirmation of neutrino flavor oscillation have been made throughout late 1990 to 2000s. Such oscillation is the clear proof of non-zero neutrino mass since this is caused by the fact that the neutrino mass eigenstates differ from that of the flavor. The neutrinos in the Standard Model, however, are massless leptons, and thus the neutrino flavor oscillation necessitates either the Standard Model to be significantly modified or a new theoretical paradigm to describe the universe better. In order to provide experimental information, it is essential for the properties of the neutrino oscillation be well understood through precision measurements of oscillation parameters, including the mixing angles, determination of the mass hierarchy between the three mass eigenstates and determination of the CP phase (Delta_CP) between neutrino and anti-neutrino oscillations. Among the several next generation neutrino experiments, this presentation covers the Deep Underground Neutrino Experiment (DUNE) which, with the high intensity neutrino beam facility, will help accomplish these goals. In this report, I will discuss the current status and plan of the DUNE experiment, including the results of the detector performance studies from the large scale prototype detectors operating at CERN and the timeline for construction and data taking of the experiment, as well as its physics prospects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAND - System for on-Axis Neutrino Detection - in the DUNE Near Detector Complex

The DUNE experiment aims to precisely measure the long baseline neutrino oscillation parameters. The DUNE Far Detector consists of four liquid argon time-projection chambers (total LAr mass of 17 kton for each cryostat), that will be installed at the Sanford Underground Research Facility (SURF) in South Dakota, 1300 km from the proton beam target. The Near Detector complex, located at Fermilab, is fundamental for limiting the systematic uncertainties, due to the neutrino/antineutrino flux and to the cross-section. It comprises three complementary detectors: ND-Lar, ND-Gar and SAND (System for on-Axis Neutrino Detection). ND-Lar and ND-Gar can move off-axis, while SAND is the only detector permanently on-axis, whose primary goal is to monitor the beam and to measure the flux. In this talk, the SAND design and the expected performances will be described together with its role within the Near Detector complex for the DUNE physics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The design, construction, and commissioning of the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90%C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times,and present details on their respective commissioning campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era

The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial tests of large format sensors for the ATLAS ITk strip tracker

For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector for the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n + -in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98 × 98 mm 2 and are designed and engineered for tolerance against the 9.7 × 10 14 1 MeV n eq /cm 2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μ m horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Technical Report for U.S.-Japan Hadronic Physics Exchange Program for Studies of Hadron Structure and QCD

Nuclear physics explores the fundamental properties of matter -- how protons and neutrons emerge as quantum systems of elementary particles, how they form the atomic nuclei, and how they give rise to the wide variety of phenomena and applications at biological, technical, and astronomical scales. It is a global scientific effort centered around large-scale experimental user facilities (particle accelerators and detectors), advanced theoretical methods and concepts, and computational techniques and resources. Exchange of knowledge and ideas, scientific collaboration, and workforce development on a global scale are essential for the future of the field. The nuclear physics program envisaged in the 2023 DOE/NSF NSAC Long-Range Plan and pursued at the U.S. National Labs has strong synergies with programs at other facilities worldwide and will realize significant benefits from international collaboration. Nuclear physics is also recognized for promoting international cooperation in the broadest sense through joint construction and operation of experimental equipment, personal contacts between scientists, and education and training. The U.S.-Japan Hadronic Physics Exchange Program (USJPHE) supported collaborative scientific research in hadronic physics and quantum chromodynamics. USJHPE focused on subject areas related to the programs at current and future experimental facilities in the U.S.\ and Japan and supported both experimental and theoretical studies. USJHPE particularly aimed to realize synergies between the hadronic physics programs at Jefferson Lab 12 GeV and J-PARC resulting from the complementarity of electromagnetic and hadronic probes in the multi-GeV energy range. Subject areas of common interest included the quark-gluon structure of hadrons and nuclei, meson and baryon spectroscopy, strangeness and hypernuclear physics, and other related topics. USJHPE also supported research in hadronic physics and nuclear-physics-enabled tests of fundamental symmetries related to the programs at Brookhaven National Lab, Fermilab, KEK, Spring-8, and university-based facilities in the U.S. and Japan. USJHPE especially promoted collaboration between the U.S. and Japanese nuclear physics communities in developing the physics program and instrumentation for the future Electron-Ion Collider. USJHPE was intended to provide travel grants to U.S.-based scientists (primary institutional affiliation with a U.S.\ university, national laboratory, or other research center) to visit Japanese institutions and conduct collaborative research there. The program supported senior researchers, postdoctoral fellows, and students. Continuing the setup of the preceding grant period, J-PARC served as the Japanese “hub” for U.S. physicists for short- and long-term visits, and JLab served as the corresponding U.S. “hub”. The program was officially managed through the U. of Connecticut in Storrs, CT. Support for Japanese physicists visiting the U.S. was provided through funds from Japanese funding agencies. The USJHPE program promoted the scientific exchange and the collaborative spirit in hadronic physics between the two countries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Superconducting quasiparticle-amplifying transmon: A qubit-based sensor for meV-scale phonons and single terahertz photons

With great interest from the quantum computing community, an immense amount of R&D effort has been invested into improving superconducting qubits. The technologies developed for the design and fabrication of these qubits can be directly applied to applications for ultralow-threshold particle detectors, e.g., low-mass dark matter and far-infrared photon sensing. We propose a novel energy-resolving sensor based on the transmon qubit architecture combined with a signal-enhancing superconducting quasiparticle amplification stage. We refer to these sensors as SQUATs: superconducting quasiparticle-amplifying transmons. We detail the operating principle and design of this new sensor and predict that, with minimal R&D effort, solid-state-based detectors patterned with these sensors can achieve sensitivity to single terahertz photons, and sensitivity to 1 meV phonons in the detector absorber substrate on the microsecond timescale. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Beam dynamics corrections to the Run-1 measurement of the muon anomaly $a_{\mu}$ at Fermilab

The Fermi National Accelerator Laboratory (FNAL) Muon $g\!-\!2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics run in 2018. The experimental result combined with the measurement from the former experiment at Brookhaven National Laboratory increases the tension with the Standard Model expectation to $4.2\sigma$, thus strengthening evidence for new physics.The magnetic anomaly is determined from the precision measurements of the muon spin precession frequency, relative to the muon momentum, and the average magnetic field seen by the beam. In an ideal case with muons orbiting in a horizontal plane with a uniform vertical magnetic field, the anomalous precession frequency $\omega_a$ is given by the difference between the spin ($s$) and cyclotron ($c$) frequencies, $\omega_a = \omega_s - \omega_c$. The observable $\omega_a$ is proportional to $a_{\mu}$.This proceeding presents the beam dynamics systematic corrections that are required to adjust the measured muon precession frequency $\omega^{m}_{a}$ to its true physical value $\omega_{a}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗