Search NASASearch

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION

Beyond Classical Searches: Enabling New Discovery Potential at the LHC (Final Technical Report)

The major goals of this project are: • 1. Employ Machine Learning to solve combinatorial problems in searches for new physics phenomena, with a focus on multijet signatures. • 2. Enable high-precision tracking for CMS at the HL-LHC by carrying out the Outer Tracker project for the Phase-II detector upgrade. Compared to the original proposal, the scope is reduced due to reduced resources in final award. In particular, the program of long-lived particle searches was descoped at that time due to lack of resources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Continuously variable voltage-controlled phase shifter

Phase shifter circuit adjusts the phase relationship between a locally generated reference frequency and a received RF signal applied to a phase-coherent detector. It is small enough to be integrated into a receiver subassembly and operates on command from remote control panels.

Johns, C. E.

Doppler shift system

A system is described for measuring velocities of radiating particles based on Doppler shift. Light from the particles is directed through a narrow band optical filter to a Fabry-Perot interferometer initially tuned to a selected center line corresponding to zero particle Doppler shift. The movable mirror of the interferometer is made to sweep about the center line by the output of a modulation oscillator. The fringe pattern output is imaged onto a pin hole through which light is directed to a photomultiplier. The output of the photomultiplier is supplied to a phase sensitive detector with the oscillator output as a reference signal and which operates in the quadrature mode. The detector's output is gain controlled and is combined with the oscillator's output to adjust the interferometer's movable mirror to acquire the line center.

Aisenberg, S.

Tracking system for moving subjects

Electronic system automatically focuses camera or spotlight on moving object. Subject is equipped with miniature ultrasonic or radio transmitter; its signal is picked up by two or more detectors, is phase detected and fed into computer which determines position of subject and sends command signals to servo for camera or spotlight.

Mogavero, L. N.

The Infrared Astronomical Satellite /IRAS/ Scientific Data Analysis System /SDAS/ sky flux subsystem

The sky flux subsystem of the Infrared Astronomical Satellite Scientific Data Analysis System is described. Its major output capabilities are (1) the all-sky lune maps (8-arcminute pixel size), (2) galactic plane maps (2-arcminute pixel size) and (3) regional maps of small areas such as extended sources greater than 1-degree in extent. The major processing functions are to (1) merge the CRDD and pointing data, (2) phase the detector streams, (3) compress the detector streams in the in-scan and cross-scan directions, and (4) extract data. Functional diagrams of the various capabilities of the subsystem are given. Although this device is inherently nonimaging, various calibrated and geometrically controlled imaging products are created, suitable for quantitative and qualitative scientific interpretation.

Stagner, J. R.

The Galileo Solid-State Imaging experiment

The Galileo Orbiter's Solid-State Imaging (SSI) experiment uses a 1.5-m focal length TV camera with 800 x 800 pixel, virtual-phase CCD detector in order to obtain images of Jupiter and its satellites which possess a combination of sensitivity levels, spatial resolutions, geometric fidelity, and spectral range that are unmatched by earlier imaging data. After describing the performance of this equipment on the basis of ground calibrations, attention is given to the SSI experiment's Jupiter system observation objectives; these encompass atmospheric science, satellite surfaces, ring structure, and 'darkside' experiments.

Belton, Michael J. S.

Comparison Of Four FFT-Based Frequency-Acquisition Techniques

Report presents comparative theoretical analysis of four conceptual techniques for initial estimation of carrier frequency of suppressed-carrier, binary-phase-shift-keyed radio signal. Each technique effected by open-loop analog/digital signal-processing subsystem part of Costas-loop phase-error detector functioning in closed-loop manner overall.

Shah, Biren N.

Signal acquisition system

A frequency-tracking feedback circuit for acquiring a communication carrier signal from a relatively noisy environment. The circuit includes a digital phase-frequency detector, a limiter, a mixer, and a voltage-controlled oscillator, connected in a long control loop in such a manner that an input band of signals is translated in frequency until the desired carrier is centered within a relatively narrow acquisition window. The characteristics of the loop are such that acquisition may be achieved even when the total power of the noise in the input signal band exceeds the carrier power, provided that the noise is relatively uniformly distributed over the input band. A technique is also disclosed for compensating from any unbalance in the noise spectrum, so that relatively low carrier-to-noise ratios can be tolerated. Also disclosed are improvements for dynamically varying the parameters of the frequency-tracking loop in such a manner as to reduce acquisition time, and a technique for detecting acquisition and handing control to post-acquisition control circuitry.

Crackel, John E.

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Automatic carrier acquisition system for phase-lock-loop receivers

Programmable oscillator and zero-beat detector acquires phase-lock of carrier by frequency scanning. Generation of high-level dc pulse at instant of zero crossing provides positive trigger for decision gate to stop search and close loop for phase-coherent tracking.

Bunce, R. C.

Multi-point measurements of ULF wave phases using a multi-channel energetic ion detector

The oscillation of differential fluxes of energetic ions modulated by a ULF wave often shows a phase shift between measurements in back-to-back detectors with look directions perpendicular to the ambient magnetic field. In a plasma of a single ion species, the phase difference is caused by displacement of the effective measurement positions by one ion gyroradius to each side of the detector. As the wave phase is periodic, the observed phase shift can correspond to a family of possible wavelengths. Simultaneous measurements of the flux modulations in different energy channels, which are equivalent to measurements of the wave phase at different positions, may make it possible to single out a unique wavelength consistent with all the measurements. Using the medium-energy-particle experiments ISEE-1 and 2, each of which may serve as a back-to-back detector, the above method was applied to a compressional Pc 5 wave observed near the equatorial plane at L between about 7 and 11. The transverse propagation properties of the wave were determined unambiguously.

Lin, N.

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138

Phase Retrieval with Signal Bias

The effect of a uniform measurement bias, due to background light, stray light, detector dark current, or detector offset, on phase retrieval wavefront sensing algorithms is analyzed. Simulation results indicate that the root-mean-square error of the retrieved phase can be more sensitive to an unaccounted-for signal bias than to random noise in practical scenarios. Three methods for reducing the impact of signal bias are presented

Thurman, Samuel T.