X-ray Assisted Scanning Tunneling Microscopy and Its Applications for Materials Science: The First Results on Cu Doped ZrTe 3

Synchrotron X-ray Scanning Tunneling Microscopy (SX-STM) is a novel imaging technique capable of providing real space chemically specific mapping with a potential of reaching atomic resolution. Determination of chemical composition along with ultra-high resolution imaging by SX-STM can be realized through excitation of core electrons by incident X-rays when their energy is tuned to an absorption edge of a particular atom during raster scanning, as is done in the conventional STM experiments. In this work, we provide a brief summary and the current status of SX-STM and discuss its applications for material science. In particular, we discuss instrumentation challenges associated with the SX-STM technique and present early experiments on Cu doped ZrTe 3 single crystals.

36 MATERIALS SCIENCE↗

Atomic‐Scale Surface Imaging of Bulk Epitaxial CsPbBr 3 Perovskite Single Crystals on Mica Using Light Assisted Scanning Tunneling Microscopy at Low‐Temperature (80 K)

Epitaxial single-crystalline CsPbBr 3 perovskite films on mica, prepared ex situ, are explored using a low-temperature scanning tunneling microscope (STM) by probing the unoccupied electronic states of their surface in ultra-high vacuum (UHV) at 80 K. Light-assisted STM measurements under a broadband illumination with visible light were employed to enhance and stabilize surface conductivity. STM imaging across the surface of macroscopic bulk CsPbBr 3 films reveals large flat terraces characterized by a specific type of surface reconstruction, consisting of parallel rows of U-shaped atomic nanostructures. These structures are spaced by 12 Å and exhibit an internal feature size of 5.1 Å. Density functional theory (DFT) calculations reproduce the experimental observations and reveal a competition between different orthorhombic CsPbBr 3 (110) surface reconstructions: a Cs-rich structure, identified as the most energetically stable, and three alternative Pb–Br-rich reconstructions, which are slightly higher in energy yet remain consistent with the STM data. Additional analyses that explicitly account for the mica substrate exclude the cubic CsPbBr 3 phase and other orthorhombic surface orientations, while showing that variations in the mica surface termination do not alter the preferred CsPbBr 3 (110) reconstruction. In conclusion, this combined approach thereby confirms our assignment and resolves previous STM interpretations of CsPbBr 3 .

36 MATERIALS SCIENCE↗

Phenylacetylene One-Dimensional Nanostructures on the Si(100)-2 1:H Surface

Using ultrahigh vacuum (UHV) scanning tunneling microscopy (STM), many olefins have been shown to self-assemble on the hydrogen-passivated Si(100)-2 1 surface into one-dimensional nanostructures. This paper demonstrates that similar one-dimensional nanostructures can also be realized using alkynes. In particular, UHV STM, sum frequency generation (SFG), and density functional theory (DFT) are employed to study the growth mechanism and binding configuration of phenylacetylene (PA) one-dimensional nanostructures on the Si(100)-2 1:H surface. Molecular-resolution UHV STM images reveal the binding position and spacing of PA with respect to the underlying silicon dimer rows. Furthermore, UHV STM characterization of heteromolecular one-dimensional nanostructures of styrene and PA shows distinct electronic contrast between the two molecules, which is confirmed using simulated STM images derived from DFT and provides insight into the nature of PA binding to silicon. Additional evidence from SFG measurements corroborates the conclusion that the terminal carbon atoms of PA retain -conjugation following reaction to the Si(100)-2 1:H surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tip-Dependent Scanning Tunneling Microscopy Imaging of Ultrathin FeO Films on Pt(111)

High-resolution scanning tunneling microscope (STM) images of moire-structured FeO films on Pt(111) were obtained in a number of different tip-dependent imaging modes. For the first time, the STM images are distinguished and interpreted unambiguously with the help of distinct oxygen- vacancy dislocation loops in the FeO moire structure. The experimental STM results are compared with the results of electronic structure calculations within the DFTþUscheme for a realistic (√91 x √ 91)R5.2º moire FeO unit cell supported on Pt(111) as well as with the results from previous studies. We find that one type of STM imaging mode, showing both Fe and O atoms, agrees well with simulated STM images, indicating that the simple Tersoff-Hamann theory is partially valid for this imaging mode. In addition, we identify other distinct, element-specific imaging modes which reveal a strong dependence on the specific tip apex state and likely result from specific tip-sample chemical interactions. From the present STMresults we show that several of the previously published conclusions for the FeO system have to be revisited.

Environmental Molecular Sciences Laboratory↗

The ReactorSTM: Atomically resolved scanning tunneling microscopy under high-pressure, high-temperature catalytic reaction conditions

To enable atomic-scale observations of model catalysts under conditions approaching those used by the chemical industry, we have developed a second generation, high-pressure, high-temperature scanning tunneling microscope (STM): the ReactorSTM. It consists of a compact STM scanner, of which the tip extends into a 0.5 ml reactor flow-cell, that is housed in a ultra-high vacuum (UHV) system. The STM can be operated from UHV to 6 bars and from room temperature up to 600 K. A gas mixing and analysis system optimized for fast response times allows us to directly correlate the surface structure observed by STM with reactivity measurements from a mass spectrometer. The in situ STM experiments can be combined with ex situ UHV sample preparation and analysis techniques, including ion bombardment, thin film deposition, low-energy electron diffraction and x-ray photoelectron spectroscopy. The performance of the instrument is demonstrated by atomically resolved images of Au(111) and atom-row resolution on Pt(110), both under high-pressure and high-temperature conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Size Effect of Local Current-Voltage Characteristics of MX 2 Nanoflakes: Local Density of States Reconstruction from Scanning Tunneling Microscopy Experiments

Local current-voltage characteristics for low-dimensional transition-metal dichalcogenides (LDTMD), as well as the reconstruction of their local density of states (LDOS) from scanning tunneling microscopy (STM) experiments, are of fundamental interest and can be useful for advanced applications. Most of the existing models either have limited applicability for complex-shaped LDTMDs (e.g., those based on the Simmons approach) or require solving of an ill-defined integral equation to deconvolute the unknown LDOS (e.g., those based on the Tersoff approach). Using a serial expansion of the Tersoff formulas, we propose a flexible method to reconstruct the LDOS from local current-voltage characteristics measured in STM experiments. We establish a set of key physical parameters, which characterize the tunneling current of a STM-probe–sample contact and the sample LDOS expanded in Gaussian functions. Using a direct variational method coupled with probabilistic analysis, we determine these parameters from the STM experiments for MoS2 nanoflakes with different numbers of layers. The main result is the reconstruction of the LDOS in a relatively wide energy range around the Fermi level, which allows us to gain insight into the local band structure of LDTMDs. The reconstructed LDOS reveal pronounced size effects for the single-layer, two-layer, and three-layer MoS 2 nanoflakes, which we relate to the low dimensionality and strong bending or corrugation of the nanoflakes. We hope that the proposed elaboration of the Tersoff approach, allowing LDOS reconstruction, will be of critical interest for the quantitative description of STM experiments and also of use to better understand the microscopic physical aspects of the surface, strain, and bending contributions to the LDTMDs’ electronic properties.

42 ENGINEERING↗

Homogeneous superconducting gap in Dy Ba 2 Cu 3 O 7 - δ synthesized by oxide molecular beam epitaxy

Much of what is known about high-temperature cuprate superconductors stems from studies based on two surface analytical tools, angle-resolved photoemission spectroscopy (ARPES) and spectroscopic imaging scanning tunneling microscopy (SI-STM). A question of general interest is whether and when the surface properties probed by ARPES and SI-STM are representative of the intrinsic properties of bulk materials. We find this question is prominent in thin films of a rarely studied cuprate Dy Ba 2 Cu 3 O 7 - δ DBCO). We synthesize DBCO films by oxide molecular beam epitaxy and study them by in situ ARPES and SI-STM. Both ARPES and SI-STM show that the surface DBCO layer is different from the bulk of the film—it is heavily underdoped, while the doping level in the bulk is close to optimal doping evidenced by bulk-sensitive mutual inductance measurements. ARPES shows the typical electronic structure of a heavily underdoped CU O 2 plane and two sets of one-dimensional bands originating from the CuO chains with one of them gapped. SI-STM reveals two different energy scales in the local density of states, with one (at ~ 18 meV ) corresponding to the superconductivity and the other one (at ~ 90 meV ) to the pseudogap. Finally, while the pseudogap shows large variations over the length scale of a few nanometers, the superconducting gap is very homogeneous. This indicates that the pseudogap and superconductivity are of different origins.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photothermal alternative to device fabrication using atomic precision advanced manufacturing techniques

The attachment of dopant precursor molecules to depassivated areas of hydrogen-terminated silicon templated with a scanning tunneling microscope (STM) has been used to create electronic devices with sub-nanometer precision, typically for quantum physics demonstrations, and to dope silicon past the solid-solubility limit, with potential applications in microelectronics and plasmonics. However, this process, which we call atomic precision advanced manufacturing (APAM), currently lacks the throughput required to develop sophisticated applications because there is no proven scalable hydrogen lithography pathway. Here, we demonstrate and characterize an APAM device workflow where STM lithography has been replaced with photolithography. An ultraviolet laser is shown to locally heat silicon controllably above the temperature required for hydrogen depassivation. STM images indicate a narrow range of laser energy density where hydrogen has been depassivated, and the surface remains well-ordered. A model for photothermal heating of silicon predicts a local temperature which is consistent with atomic-scale STM images of the photo-patterned regions. Finally, a simple device made by exposing photo-depassivated silicon to phosphine is found to have a carrier density and mobility similar to that produced by similar devices patterned by STM.

42 ENGINEERING↗

Atomic-scale Imaging of Magnetic and Electronic Orders in Complex Oxides (Final Technical Report)

This research project aimed to expand spin‐polarized scanning tunneling microscopy (SP‐STM) imaging to complex quantum materials, initially focusing on uncovering the magnetic structure of doped Iridium‐based oxides (iridates) with subatomic precision. Chemical doping of complex oxides has led to exciting discoveries over the past few decades, such as high-temperature superconductivity and colossal magnetoresistance. However, the process of chemical doping is often accompanied by spatial inhomogeneity, characterized by nanometer-scale variations in electronic and/or magnetic properties of the material. SP-STM can in principle be used to image magnetic properties, but SP-STM has historically been applied primarily to relatively simple magnetic materials and nanostructures. The main objectives of this project included: (1) visualizing the evolution of magnetism in iridates, as a function of charge carrier doping, temperature and energy, (2) elucidating the relationship between the inhomogeneous electronic structure and magnetism at the nanoscale, and (3) searching for signatures of new magnetic phases in iridates and other quantum materials. Advanced STM and SP-STM imaging was also applied to select kagome metals and superconductors. The comprehensive experimental approach developed in this project provided a foundation to study quantum materials in which spin, charge and orbital degrees of freedom intertwine to create new states of matter.

36 MATERIALS SCIENCE↗

Scanning tunneling microscopy characterization of the geometric and electronic structure of hydrogen-terminated silicon surfaces

Scanning tunneling microscopy (STM) methods are used to characterize hydrogen-terminated Si surfaces prepared by a novel method. The surface preparation method is used to expose the Si-SiO2 interface. STM images directly reveal the topographic structure of the Si-SiO2 interface. The dependence of interface topography on oxide preparation conditions observed by STM is compared to the results of conventional surface characterization methods. Also, the electronic structure of the hydrogen-terminated surface is studied by STM spectroscopy. The near-ideal electronic structure of this surface enables direct tunnel spectroscopy measurements of Schottky barrier phenomena. In addition, this method enables probing of semiconductor subsurface properties by STM.

Kaiser, W. J.↗

Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials

We present a summary of the research, citations of publications resulting from the research and abstracts of such publications. We have made no inventions in the performance of the work in this project. The main goals of the project were to set up a Chemical Vapor Deposition (CVD) diamond growth system attached to an UltraHigh Vacuum (UHV) atomic resolution Scanning Tunneling Microscopy (STM) system and carry out experiments aimed at studying the properties and growth of diamond films using atomic resolution UHV STM. We successfully achieved these goals. We observed, for the first time, the atomic structure of the surface of CVD grown epitaxial diamond (100) films using UHV STM. We studied the effects of atomic hydrogen on the CVD diamond growth process. We studied the electronic properties of the diamond (100) (2x1) surface, and the effect of alkali metal adsorbates such as Cs on the work function of this surface using UHV STM spectroscopy techniques. We also studied, using STM, new electronic materials such as carbon nanotubes and gold nanostructures. This work resulted in four publications in refereed scientific journals and five publications in refereed conference proceedings.

Perez, Jose M.↗

The NASA Spacecraft Transponding Modem

A new deep space transponder is being developed by the Jet Propulsion Laboratory for NASA. The Spacecraft Transponding Modem (STM) implements the standard transponder functions and the channel service functions that have previously resided in spacecraft Command/Data Subsystems. The STM uses custom ASICs, MMICs, and MCMs to reduce the active device parts count to 70, mass to I kg, and volume to 524 cc. The first STMs will be flown on missions launching in the 2003 time frame. The STM tracks an X-band uplink signal and provides both X-band and Ka-band downlinks, either coherent or non-coherent with the uplink. A NASA standard Command Detector Unit is integrated into the STM, along with a codeblock processor and a hardware command decoder. The decoded command codeblocks are output to the spacecraft command/data subsystem. Virtual Channel 0 (VC-0) (hardware) commands are processed and output as critical controller (CRC) commands. Downlink telemetry is received from the spacecraft data subsystem as telemetry frames. The STM provides the following downlink coding options: the standard CCSDS (7-1/2) convolutional coding, ReedSolomon coding with interleave depths one and five, (15-1/6) convolutional coding, and Turbo coding with rates 1/3 and 1/6. The downlink symbol rates can be linearly ramped to match the G/T curve of the receiving station, providing up to a 1 dB increase in data return. Data rates range from 5 bits per second (bps) to 24 Mbps, with three modulation modes provided: modulated subcarrier (3 different frequencies provided), biphase-L modulated direct on carrier, and Offset QPSK. Also, the capability to generate one of four non-harmonically related telemetry beacon tones is provided, to allow for a simple spacecraft status monitoring scheme for cruise phases of missions. Three ranging modes are provided: standard turn around ranging, regenerative pseudo-noise (PN) ranging, and Differential One-way Ranging (DOR) tones. The regenerative ranging provides the capability of increasing the ground received ranging SNR by up to 30 dB. Two different avionics interfaces to the command/data subsystem's data bus are provided: a MIL STD 1553B bus or an industry standard PCI interface. Digital interfaces provide the capability to control antenna selection (e.g., switching between high gain and low gain antennas) and antenna pointing (for future steered Ka-band antennas).

Berner, Jeff B.↗

Analysis and Prediction of Ice Shedding for a Full-Scale Heated Tail Rotor

When helicopters are to fly in icing conditions, it is necessary to consider the possibility of ice shed from the rotor blades. In 2013, a series of tests were conducted on a heated tail rotor at NASA Glenn's Icing Research Tunnel (IRT). The tests produced several shed events that were captured on camera. Three of these shed events were captured at a sufficiently high frame rate to obtain multiple images of the shed ice in flight that had a sufficiently long section of shed ice for analysis. Analysis of these shed events is presented and compared to an analytical Shedding Trajectory Model (STM). The STM is developed and assumes that the ice breaks off instantly as it reaches the end of the blade, while frictional and viscous forces are used as parameters to fit the STM. The trajectory of each shed is compared to that predicted by the STM, where the STM provides information of the shed group of ice as a whole. The limitations of the model's underlying assumptions are discussed in comparison to experimental shed events.

rotorcraft↗

Analysis and Prediction of Ice Shedding for a Full-Scale Heated Tail Rotor

When helicopters are to fly in icing conditions, it is necessary to consider the possibility of ice shed from the rotor blades. In 2013, a series of tests were conducted on a heated tail rotor at NASA Glenn's Icing Research Tunnel (IRT). The tests produced several shed events that were captured on camera. Three of these shed events were captured at a sufficiently high frame rate to obtain multiple images of the shed ice in flight that had a sufficiently long section of shed ice for analysis. Analysis of these shed events is presented and compared to an analytical Shedding Trajectory Model (STM). The STM is developed and assumes that the ice breaks off instantly as it reaches the end of the blade, while frictional and viscous forces are used as parameters to fit the STM. The trajectory of each shed is compared to that predicted by the STM, where the STM provides information of the shed group of ice as a whole. The limitations of the model's underlying assumptions are discussed in comparison to experimental shed events.

icing↗

Atomic-scale electrochemistry on the surface of a manganite

The doped manganese oxides (manganites) have been widely studied for their colossal magnetoresistive effects, for potential applications in oxide spintronics, electroforming in resistive switching devices, and are materials of choice as cathodes in modern solid oxide fuel cells. However, little experimental knowledge of the dynamics of the surfaces of perovskite manganites at the atomic scale exists. Here, through in-situ scanning tunnelling microscopy (STM), we demonstrate atomic resolution on samples of La 0.625 Ca 0.375 MnO 3 grown on (001) SrTiO 3 by pulsed laser deposition (PLD). Furthermore, by applying triangular DC waveforms of increasing amplitude to the STM tip, and measuring the tunnelling current, we demonstrate the ability to both perform and monitor surface electrochemical processes at the atomic level, including, for the first time in a manganite, formation of single and multiple oxygen vacancies, disruption of the overlying manganite layers, and removal and deposition of individual atomic units or clusters. Our work paves the way for better understanding of surface oxygen reactions in these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗