Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗

The Pixel Luminosity Telescope: a detector for luminosity measurement at CMS using silicon pixel sensors

The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 “telescopes”, with eight telescopes installed around the beam pipe at either end of the detector and each telescope composed of three individual silicon sensor planes. The per-bunch instantaneous luminosity is measured by counting events where all three planes in the telescope register a hit, using a special readout at the full LHC bunch-crossing rate of 40 MHz. The full pixel information is read out at a lower rate and can be used to determine calibrations, corrections, and systematic uncertainties for the online and offline measurements. This paper details the commissioning, operational history, and performance of the detector during Run 2 (2015–18) of the LHC, as well as preparations for Run 3, which will begin in 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LGAD-Based Silicon Sensors for 4D Detectors

Low-Gain Avalanche Diodes (LGAD) are a class of silicon sensors developed for the fast detection of Minimum Ionizing Particles (MIPs). The development was motivated by the need of resolving piled-up tracks of charged particles emerging from several vertexes originating from the same bunch-crossing in High-Energy Physics (HEP) collider experiments, which, however, are separated not only in space but also in time by a few tens of picoseconds. Built on thin silicon substrates and featuring an internal moderate gain, they provide fast signals for excellent timing performance, which are therefore useful to distinguish the different tracks. Unfortunately, this comes at the price of poor spatial resolution. To overcome this limitation, other families of LGAD-based silicon sensors which can deliver in the same substrate both excellent timing and spatial information are under development. Such devices are, to name a few, capacitively coupled LGADs (AC-LGAD), deep-junction LGADs (DJ-LGAD) and trench-isolated LGADs (TI-LGADs). These devices can be fabricated by even small-scale research-focused clean rooms for faster development within the scientific community. However, to scale up production, efforts towards integrating these sensor concepts in CMOS substrates, with the obvious advantage of the possibility of integrating part of the read-out electronics in the same substrate, have begun.

spatial resolution↗

Radiation-Induced Dark Counts for Silicon Single-Photon Detectors in Space

Single-photon detectors operating on satellites for use in a quantum communications network can incur large dark-count-rate increases from the natural radiation environment of space. Displacement damage to the material lattice of a detector from the ionizing radiation can result in a permanent dark-count increase in the detector. In this work, we analyze the radiation-induced dark-count rate of a silicon single-photon avalanche diode onboard a satellite at different orbiting altitudes, as well as, the additional radiation from a nuclear-disturbed environment caused by a high-altitude nuclear explosion. For detectors on low Earth orbit satellites, protons are the biggest source of radiation damage and are best mitigated by choosing an orbit that minimizes exposure when passing through the South Atlantic Anomaly and Polar Cusps. Detectors on medium Earth orbit and geostationary orbit satellites, if shielded by more than 10 mm of aluminum, provide the best platform in terms of the least amount of radiation damage to the detectors. In the event of a high-altitude nuclear explosion, the artificial radiation belts produced by the explosion will cause too much damage to silicon single-photon detectors on low Earth orbit satellites and render them unfit for quantum communications in less than a day. Higher orbit satellites will only suffer minor dark-count-rate increases from the artificial radiation belts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low spin spectroscopy of neutron-rich Cl 43 , 44 , 45 via β - and β n decay

In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β ⁢1⁢ n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-loss Si-based Dielectrics for High Frequency Components of Superconducting Detectors

Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The film's morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.

low-loss dielectrics↗

First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)

First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.

Instruments & Instrumentation↗

Heavy Flavor Physics at the sPHENIX Experiment

The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Source characterization of a detector for heavy and superheavy nuclei

A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗