Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrum Width”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Twins Embedding of Type Ia Supernovae. II. Improving Cosmological Distance Estimates

We show how spectra of Type Ia supernovae (SNe Ia) at maximum light can be used to improve cosmological distance estimates. In a companion article, we used manifold learning to build a three-dimensional parameterization of the intrinsic diversity of SNe Ia at maximum light that we call the "Twins Embedding."In this article, we discuss how the Twins Embedding can be used to improve the standardization of SNe Ia. With a single spectrophotometrically calibrated spectrum near maximum light, we can standardize our sample of SNe Ia with an rms of 0.101 0.007 mag, which corresponds to 0.084 0.009 mag if peculiar velocity contributions are removed and to 0.073 0.008 mag if a larger reference sample were obtained. Our techniques can standardize the full range of SNe Ia, including those typically labeled as peculiar and often rejected from other analyses. We find that traditional light-curve width + color standardization such as SALT2 is not sufficient. The Twins Embedding identifies a subset of SNe Ia, including, but not limited to, 91T-like SNe Ia whose SALT2 distance estimates are biased by 0.229 0.045 mag. Standardization using the Twins Embedding also significantly decreases host-galaxy correlations. We recover a host mass step of 0.040 0.020 mag compared to 0.092 0.026 mag for SALT2 standardization on the same sample of SNe Ia. These biases in traditional standardization methods could significantly impact future cosmology analyses if not properly taken into account.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Observation of structure in the J/ψ-pair mass spectrum

Using proton-proton collision data at centre-of-mass energies of $\sqrt{s}$ = 7, 8 and 13 TeV recorded by the LHCb experiment at the Large Hadron Collider, corresponding to an integrated luminosity of 9 fb -1 , the invariant mass spectrum of J/ψ pairs is studied. A narrow structure around 6.9 GeV/c 2 matching the lineshape of a resonance and a broad structure just above twice the J/ψ mass are observed. The deviation of the data from nonresonant J/ψ-pair production is above five standard deviations in the mass region between 6.2 and 7.4 GeV/c 2 , covering predicted masses of states composed of four charm quarks. The mass and natural width of the narrow X(6900) structure are measured assuming a Breit-Wigner lineshape.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Theoretical Analysis of Resonant Tunneling Enhanced Field Emission

In this paper, we develop an exact analytical quantum theory for field emission from surfaces with a nearby quantum well, by solving the one-dimensional time-independent Schrödinger equation. The quantum well, which may be introduced by ions, atoms, nanoparticles, etc., is simplified as a square potential well with depth H, width d, and distance to the surface L. The theory is used to analyze the effects of the quantum well (d, H, and L), the cathode properties (work function W and Fermi energy E F ), and dc field F. It is found that the quantum well can lead to resonant tunneling enhanced field emission up to several orders of magnitude larger than that from bare cathode surfaces. In the meantime, the electron-emission-energy spectrum is significantly narrowed. The strong enhancement region is bounded by the conditions eFL + H ≥ W + C and eFL ≤ W, with e being the elementary charge (positive) and C a constant dependent on dc field F. It is also found that the linear shift of resonance peaks in the electron-emission-energy spectrum with dc field F follows ε p =ε p⁢0 –e⁢FL, with ε p⁢0 being approximately the eigenenergies for electrons confined in a square potential well without a dc field. Finally, the theory provides insights for the design of high-efficiency field emitters, which can produce a high current and highly collimated electron beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Environmentally Robust Quantum Dot Down Converters for Highly Efficient Solid State Lighting

This project contributes fundamental understanding of the chemical synthesis of cadmium free quantum dots (QDs) designed for solid state lighting (SSL). Methods to incorporate gallium into quantum dot architectures were explored, which led to more stable and brighter solid state lighting devices. These findings will help advance the incorporation of quantum dots in highly energy efficient lighting devices with a warm color spectrum. Such Cd-free lighting devices can greatly accelerate the adoption of high efficiency, warm spectrum lighting in buildings. The project targeted InP/GaP/ZnS colloidal quantum dots that more effectively absorb the blue light produced by light emitting diode packages and emit monochromatic red light with near perfect efficiency. While significant improvements in the QD absorptivity were demonstrated, the absorbance increase achieved was 3x rather than the targeted 10x increase. Similarly, the luminescence from these QDs achieved about half of the target photoluminescence quantum yield (PLQY) and twice the desired spectral width, a measure of the color purity of their luminescence. While the target characteristics and some of the year 2/2 milestones were not met, the new QD architectures did lead to greater stability on SSL packages, a sign of the long term promise of the technology.

36 MATERIALS SCIENCE↗

Observation of new excited ${B} ^0_{s}$ states

A structure is observed in the ${B} ^{\pm }{K} ^{\mp }$ mass spectrum in a sample of proton–proton collisions at centre-of-mass energies of 7, 8, and 13 TeV, collected with the LHCb detector and corresponding to a total integrated luminosity of 9$\,\text {fb} ^{-1}$. The structure is interpreted as the result of overlapping excited ${B} ^0_{s}$ states. With high significance, a two-peak hypothesis provides a better description of the data than a single resonance. Under this hypothesis the masses and widths of the two states, assuming they decay directly to ${B} ^{\pm }{K} ^{\mp }$, are determined to be $\begin{aligned} m_1&= 6063.5 \pm 1.2 \text { (stat)} \pm 0.8\text { (syst)}\,\text {Me}\text {V}, \\ \Gamma _1&= 26 \pm 4 \text { (stat)} \pm 4\text { (syst)}\,\text {Me}\text {V}, \\ m_2&= 6114 \pm 3 \text { (stat)} \pm 5\text { (syst)}\,\text {Me}\text {V}, \\ \Gamma _2&= 66 \pm 18 \text { (stat)} \pm 21\text { (syst)}\,\text {Me}\text {V}. \end{aligned}$ Alternative values assuming a decay through ${B} ^{*\pm }{K} ^{\mp }$, with a missing photon from the $B^{*\pm } \rightarrow B^{\pm }\gamma $ decay, which are shifted by approximately 45 $\,\text {Me}$V, are also determined. The possibility of a single state decaying in both channels is also considered. The ratio of the total production cross-section times branching fraction of the new states relative to the previously observed $B_{s2}^{*0}$ state is determined to be $0.87 \pm 0.15 \text { (stat)} \pm 0.19 \text { (syst)}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Are Supercells Resistant to Entrainment because of Their Rotation?

This research investigates a hypothesis posed by previous authors, which argues that the helical nature of the flow in supercell updrafts makes them more resistant to entrainment than nonsupercellular updrafts because of the suppressed turbulence in purely helical flows. It was further supposed that this entrainment resistance contributes to the steadiness and longevity of supercell updrafts. A series of idealized large-eddy simulations were run to address this idea, wherein the deep-layer shear and hodograph shape were varied, resulting in supercells in the strongly sheared runs, nonsupercells in the weakly sheared runs, and variations in the percentage of streamwise vorticity in updrafts among runs. Fourier energy spectrum analyses show well-developed inertial subranges in all simulations, which suggests that the percentages of streamwise and crosswise vorticity have little effect on turbulence in convective environments. Additional analyses find little evidence of updraft-scale centrifugally stable flow within updrafts, which has also been hypothesized to limit horizontal mass flux across supercell updrafts. Results suggest that supercells do have smaller fractional entrainment rates than nonsupercells, but these differences are consistent with theoretical dependencies of entrainment on updraft width, and with supercells being wider than nonsupercells. Thus, while supercells do experience reduced fractional entrainment rates and entrainment-driven dilution, this advantage is primarily attributable to increased supercell updraft width relative to ordinary convection, and has little to do with updraft helicity and rotation.

Peters, John M.↗

Theory of Photoluminescence Spectral Line Shapes of Semiconductor Nanocrystals

Single-molecule photoluminescence (PL) spectroscopy of semiconductor nanocrystals (NCs) reveals the nature of exciton–phonon interactions in NCs. Understanding the homogeneous spectral line shapes and their temperature dependence remains an open problem. Here, we develop an atomistic model to describe the PL spectrum of NCs, accounting for excitonic effects, phonon dispersion relations, and exciton–phonon couplings. We validate our model using single-NC measurements on CdSe/CdS NCs from T = 4 to 290 K, and we find that the slightly asymmetric main peak at low temperatures is comprised of a narrow zero-phonon line (ZPL) and acoustic phonon sidebands. Furthermore, we identify the specific phonon modes that give rise to the optical phonon sidebands. At temperatures above 200 K, the spectral line width shows a stronger dependence upon the temperature, which we demonstrate to be correlated with higher order exciton–phonon couplings. We also identify the line width dependence upon reorganization energy, NC core sizes, and shell thicknesses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution X-ray spectroscopy of Supergiant HMXB 4U1700-37 during the compact object eclipse.

In this work, we present an analysis of the first observation of the iconic High Mass X-ray Binary 4U 1700-37 with the Chandra High Energy Transmission Gratings during an X-ray eclipse. The goal of the observation was to study the structure/physical conditions in the clumpy stellar wind through high resolution spectroscopy. We find that: a) emission line brightness from K shell transitions, corresponding to near neutral species, directly correlates with continuum illumination. However, these lines do not greatly diminish during eclipse. This is readily explained if fluorescence Kα emission comes from the bulk of the wind. b) The highly ionised Fe xxv and Fe xxvi Lyα diminish during eclipse. Thus, they must be produced in the vicinity of the compact object where log ξ > 3. c) to describe the emission line spectrum, the sum of two self consistent photo ionisation models with low ionisation (log ξ ~ -1) and high ionisation (log ξ ~2.4) is required. From their emission measures, the clump-to-interclump density ratio can be estimated to be nc/ni ~ 300. To fit the complex He-like Si xiii profile, the plasma requires a broadening with vbulk ~ 840 km s-1. Reproducing the observed r ≈ f line fluxes requires the addition of a third collisionally ionised plasma. d) Emission lines widths appear unresolved at the hetg gratings resolution with exception of Silicon. There is no clear radial segregation between (quasi)neutral and ionised species, consistent with cold wind clumps interspersed in a hot rarefied interclump medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Two methods to study inelastic neutron-scattering measurements based on ω n (q) versus S(q, ω) applied to the magnetic open honeycomb lattice Tb 2 Ir 3 Ga 9

This work describes two methods to fit the inelastic neutron-scattering spectrum S(q, ω) with wavevector q and frequency ω. The common and well-established method extracts the experimental spin-wave branches ω n (q) from the measured spectra S(q, ω) and then minimizes the difference between the observed and predicted frequencies. When n branches of frequencies are predicted but the measured frequencies overlap to produce only m < n branches, the weighted average of the predicted frequencies must be compared to the observed frequencies. A penalty is then exacted when the width of the predicted frequencies exceeds the width of the observed frequencies. The second method directly compares the measured and predicted intensities S(q, ω) over a grid {q i , ω j } in wavevector and frequency space. After subtracting background noise from the observed intensities, the theoretical intensities are scaled by a simple wavevector-dependent function that reflects the instrumental resolution. Furthermore, the advantages and disadvantages of each approach are demonstrated by studying the open honeycomb material Tb 2 Ir 3 Ga 9 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam focusing and consequences for Doppler backscattering measurements

The phenomenon of focusing of microwave beams in a plasma near a turning-point caustic is discussed by exploiting the analytical solution to the Gaussian beam-tracing equations in the two-dimensional (2-D) linear-layer problem. The location of maximum beam focusing and the beam width at that location are studied in terms of the beam initial conditions. This focusing must be taken into account to interpret Doppler backscattering (DBS) measurements. We find that the filter function that characterises the scattering intensity contribution along the beam path through the plasma is inversely proportional to the beam width, predicting enhanced scattering from the beam focusing region. We show that the DBS signal enhancement for decreasing incident angles between the beam path and the density gradient is due to beam focusing and not due to forward scattering, as was originally proposed by (Gusakov et al., (Plasma Phys. Contr. Fusion, vol. 56, 2014, p. 0250092014, 2017); Plasma Phys. Rep. vol. 43(6), 2017, pp. 605–613). The analytic beam model is used to predict the measurement of the k y density-fluctuation wavenumber power spectrum via DBS, showing that, in an NSTX-inspired example, the spectral exponent of the turbulent, intermediate-to-high k y density-fluctuation spectrum might be quantitatively measurable via DBS, but not the spectral peak corresponding to the driving scale of the turbulent cascade.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Raman gap and collisional absorption

One of the long-standing puzzles observed in many laser-plasma experiments is the gap in the Raman backscattering spectrum. This gap is characterized by the absence of backscattered light between some critical wavelength and twice the incident laser wavelength. The latter is associated with the absolute Raman instability from the quarter-critical density surface. Supported by particle-in-cell (PIC) simulations, it is suggested that the gap can result from the collisional damping of the backscattered light. A linear analysis of the competition between the Raman growth rate and the damping rate in a non-homogenous plasma predicts the gap's existence and width as a function of the system's parameters. The theory is compared with the PIC simulations and past experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of structures in the J/ψ+ψ(2S) mass spectrum with the ATLAS detector

A search for resonant structures in the mass spectrum is performed using proton-proton collision data at , corresponding to an integrated luminosity of , recorded by the ATLAS experiment at the LHC. The decay channels of and are analyzed. An excess near 6.9 GeV is observed in both channels with a combined significance of . No significant signal is observed near 7.2 GeV, and an upper limit on its yield relative to is provided. A simultaneous fit with the di- channel is carried out under assumptions regarding the resonance interferences, yielding a ratio of the partial decay widths between the and di- channels of for the resonance near 6.9 GeV.

Aad, G↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons

An avalanche effect yielding inherent gain can be exploited in thin, single-crystal chemical vapor deposition (scCVD) diamond. It occurs when a high enough bias is applied across the diamond thickness while avoiding breakdown. This charge multiplication effect was studied previously with alpha particles and heavy ions either by using the transient current technique or by measuring the energy spectrum. The measurements we obtained to evaluate the charge multiplication performance of a 10 μm thick scCVD diamond detector used a novel approach—we employed an electrometer to characterize the response of the detector by performing directly coupled current measurements (time-averaged charge, at 1 Hz sampling) when exposed to 14.1 MeV neutrons from deuterium-tritium fusion. We measured both the dark and irradiated currents from the detector over a range of applied displacement field values from 2 to 75 V/μm. A histogram method with central mean and standard deviation width was used to determine the current over each measurement duration typically from 100 to 300 seconds. The dark-subtracted irradiated current (i.e., contrast) was used to evaluate the gain of the detector at each applied displacement field. The contrast at an applied displacement field between 15 and 20 V/μm was higher than the expected linear increase in contrast proportional to the increased applied bias, indicating the possible presence of avalanche events in the diamond. The detector response also indicated possible polarization and charge depletion effects. These results provide an opportunity to further explore the use of thin scCVD diamond as a fast neutron current mode detector with inherent gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergence of a Low-Energy Peak in the Smoothed Absolute Value Circular Dichroism Spectra of Small Helical Gold Nanorods

We calculate, using time-dependent density functional theory, absorption and circular dichroism (CD) spectra for a series of small helical gold nanorod structures with a width of 0.6 nm and length increasing from 0.7 nm for Au 24 to 1.9 nm for Au 56 . For a low-energy window, ranging from 1.7 to 4.1 eV, broadening the lines in the absorption spectra results in a low energy peak which previous studies have identified as the (localized) plasmon resonance. As expected, the absorption peak position of the plasmon resonance systematically redshifts as the length of the nanorod increases. However, trends in the CD and straightforwardly broadened CD spectra are more difficult to discern. We introduce the idea of an absolute value CD spectrum and show that broadening the lines results in a low energy peak that has not previously been reported. The peak position systematically redshifts as the length of the nanorod increases but over a significantly smaller range than that for the absorption spectrum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On-chip spectrometers using stratified waveguide filters

We present an ultra-compact single-shot spectrometer on silicon platform for sparse spectrum reconstruction. It consists of 32 stratified waveguide filters (SWFs) with diverse transmission spectra for sampling the unknown spectrum of the input signal and a specially designed ultra-compact structure for splitting the incident signal into those 32 filters with low power imbalance. Each SWF has a footprint less than 1 µm × 30,µm, while the 1 × 32 splitter and 32 filters in total occupy an area of about 35 µm × 260 µm, which to the best of our knowledge, is the smallest footprint spectrometer realized on silicon photonic platform. Experimental characteristics of the fabricated spectrometer demonstrate a broad operating bandwidth of 180 nm centered at 1550 nm and narrowband peaks with 0.45 nm Full-Width-Half-Maximum (FWHM) can be clearly resolved. This concept can also be implemented using other material platforms for operation in optical spectral bands of interest for various applications.

42 ENGINEERING↗