Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Improving ProtoDUNE pion cross-section measurements with NuGraph Michel-electron tagging

Understanding hadron-argon interactions is essential for precise neutrino energy reconstruction and final-state interaction modeling in liquid-argon time projection chamber (LArTPC) experiments such as DUNE. In particular, pion absorption and charge-exchange processes constitute significant sources of systematic uncertainty in neutrino oscillation measurements. ProtoDUNE-SP, a large-scale LArTPC prototype operated at the CERN Neutrino Platform and exposed to charged-particle test beams in the few-GeV range, enables direct measurements of these processes. This work focuses on the measurement of differential cross sections for pion absorption and charge exchange using the 2 GeV/c pion beam data from the ProtoDUNE-SP run. A key component of this analysis is the identification of Michel electrons from $\pi \rightarrow \mu \rightarrow e$ decay chains, which helps separate different interaction topologies and improves background rejection. Michel electron identification will also assist in reliably calibrating the electromagnetic response in ProtoDUNE-SP data and for the future DUNE detectors. In this analysis, we apply NuGraph to identify Michel electrons. NuGraph is a graph neural network that models detector hits as nodes connected by spatial and temporal edges for particle and topology classification in LArTPC detectors. We first benchmark NuGraph’s Michel electron classification performance using ICEBERG data, a small-scale LArTPC prototype used for DUNE electronics and reconstruction development, and then transfer the approach to ProtoDUNE-SP. This poster presents the analysis strategy, NuGraph-based classification studies, and discusses how these developments are expected to improve the pion cross-section measurement.

Razafinime, Soamasina Herilala [Cincinnati U.] (OR↗

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

Readout electronics for low occupancy High-Pressure Gas TPCs

High-Pressure Gas Time Projection Chambers (HPgTPCs) have benefits such as low energy thresholds, magnetisability, and 4π acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for Gaseous Argon Near Detector (ND-GAr), which is part of the Phase-II more capable near detector for DUNE. These electronics reduce the cost significantly compared to using collider readout electronics, which are typically designed for much higher occupancy and therefore, for example, need much larger numbers of FPGAs and power per channel. We demonstrate the performance of our electronics with the Teststand for an Overpressurised Argon Detector (TOAD) at Fermilab in the US at a range of pressures and gas mixtures up to 4.5 barA, reading out ∼10 000 channels from a Multi-Wire Proportional Chamber (MWPC). The operation took place between April and July of 2024. We measure the noise characteristics of the system to be sufficiently low, and we identify sources of noise that can be further mitigated in the next iteration. We also note that the cooling scheme used in the test requires improvement before full-scale deployment. Despite these necessary improvements, we show that the system can fulfil the needs of a HPgTPC for a fraction of the price of collider readout electronics.

Data acquisition concepts↗

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]↗

The Case for Reducing Emissions from Heavy-Duty Off-Road Applications via Ducted Fuel Injection

Designers of heavy-duty diesel engines use a variety of techniques to improve efficiency and reduce pollutant emissions. Ducted fuel injection (DFI), high fuel injection pressures, optimized injection orifices, multiple injection sites, and oxygenated fuels are a few techniques used by designers to improve fuel/charge-gas mixtures within the combustion chamber to improve efficiency and emissions results. Ducted fuel injection (DFI) has been proven to substantially reduce soot for low- and mid-load conditions in heavy duty engines, without significantly increasing nitrogen oxides (NO x ). This study investigates the performance of DFI utilizing conventional diesel fuel and the potential the technique has for future research utilizing varieties of test fuels and operating parameter values. Optimization for high engine efficiency and low emissions will help facilitate DFI deployment for substantial environmental benefits in heavy-duty sectors where electrification and/or carbon-free fuels aren’t feasible.

33 ADVANCED PROPULSION SYSTEMS↗

MicroBooNE investigations on the photon interpretation of the MiniBooNE low energy excess

The MicroBooNE experiment is a liquid argon time projection chamber with 85-ton active volume at Fermilab, operated from 2015 to 2020 to collect neutrino data from Fermilab's Booster Neutrino Beam. One of MicroBooNE's physics goals is to investigate possible explanations of the low-energy excess observed by the MiniBooNE experiment in $\nu_{\mu}\rightarrow \nu_{e}$ neutrino oscillation measurements. MicroBooNE has performed searches to test hypothetical interpretations of the MiniBooNE low-energy excess, including the underestimation of the photon background or instrinic $\nu_{e}$ background. This thesis presents MicroBooNE's searches for two neutral current (NC) single-photon production processes that contribute to the photon background of the MiniBooNE measurement: NC $\Delta$ resonance production followed by $\Delta$ radiative decay: $\Delta \rightarrow N\gamma$, and NC coherent single-photon production. Both searches take advantage of boosted decision trees to yield efficient background rejection, and a high-statistic NC $\pi^0$ measurement to constrain dominant background, and make use of MicroBooNE's first three years of data. The NC $\Delta \rightarrow N\gamma$ measurement yielded a bound on the $\Delta$ radiative decay process at 2.3 times the predicted nominal rate at 90\% confidence level(C.L.), disfavoring a candidate photon interpretation of the MiniBooNE low-energy excess as a factor of 3.18 times the nominal NC Δ radiative decay rate at the 94.8\% C.L. The NC coherent single photon measurement leads to the world's first experimental limit on the cross-section of this process below 1 GeV, of $1.49 \times 10^{-41} \text{cm}^2$ at 90\% C.L., corresponding to 24.0 times the nominal prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development, Verification, and Validation of an OpenFOAM-Based Solver for Modeling Inertial Fusion Energy Chambers

Our work seeks to introduce a computational tool tailored to the physics of inertial fusion energy chambers, in particular, those concepts based on thick liquid walls. In this approach, the structural materials are protected by several neutron mean-free-paths of renewable liquid and thus will be able to survive much longer than un-shielded walls, with virtually all structures lasting for the life of the plant and enabling the use of commercially available and qualified materials. The OpenFOAM-based solver named rhoCentralFoam has been used as a starting point. rhoCentralFoam belongs to the standard OpenFOAM solver toolset. It is a high-speed, explicit compressible flow solver with shock-capturing capability. While the main features have been retained, the solver had to be restructured to make use of tabular data for equations of states, a necessary addition to model the complex thermo-physical properties of ionized gasses. This entailed the need to change the independent state variables used by the solver, resulting in a new thermodynamic library and slightly different solution algorithm. Moreover, a radiation heat transfer model based on the P-1 approximation was added to the solver. The solver is verified against an analytical solution from the Sedov-Taylor-Neumann test problem to showcase the ability of the hydrodynamic solvers to handle strong shocks, whereas the P-1 model was verified using a simple one-dimensional problem with an analytical solution. Additionally, a validation case involving shock-wave propagation through jet array is presented, and the results are compared with experimental data from the open literature. Lastly, in order to showcase the utility of the solver for practical cases, we applied the refined solver to two representative scenarios: gas venting within the HYLIFE-II chamber and the compression of the gas following the partial ablation of the liquid wall.

Chamber dynamics↗

Solar Panel Anti-Soiling Evaluation (CRADA Final Report)

NREL and Pellucere Technologies, Inc. will cooperate to leverage NREL’s existing testing and data analysis capability to evaluate solar panel anti-soiling coating in both laboratory testing conditions and from actual solar array field data.

14 SOLAR ENERGY↗

SBND Shower Reconstruction with SPINE

The Short-Baseline Near Detector (SBND) is a liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino (SBN) program at Fermilab. SBND is designed to investigate the Low-Energy Excess (LEE), an unexplained excess of electron-like events observed by previous short-baseline neutrino experiments that may point to physics beyond the Standard Model. In LArTPC detectors, precise shower reconstruction is essential for distinguishing electrons from photons, a key requirement for testing possible explanations of the LEE and improving $\nu_e$ event selection. In this poster, the reconstruction studies using the Scalable Particle Imaging with Neural Embeddings (SPINE), a machine learning based reconstruction framework for particle imaging detectors will be presented. SPINE combines sparse convolutional neural networks (CNN) and graph neural networks (GNN) to enable detailed reconstruction and characterization of neutrino interactions in LArTPC detectors. Shower calorimetry and kinematic reconstruction are performed in dedicated post-processing stages. Strong agreement between data and Monte Carlo simulation will be demonstrated, indicating high-precision detector calibration and reconstruction performance. The agreement between reconstructed and true electron shower energy will also be discussed, emphasizing the robustness of the shower reconstruction performance. These results demonstrate the unprecedented precision achievable with SPINE in SBND, highlighting their potential for future high-resolution neutrino measurements.

Fan, Castaly [Florida U.; Fermilab] (ORCID:0000000↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

MIP dQ/dx Calibration in DUNE ND-LAr Prototypes with Pixelated Charge Readout

The Deep Underground Neutrino Experiment (DUNE) will be a next-generation long baseline neutrino oscillation experiment that will employ LArTPC technology in a near detector placed at Fermilab and a far detector at the Sanford Underground Research Facility, at a baseline of 1300 km. The DUNE Liquid Argon Near Detector (ND-LAr) design takes into account the high neutrino intensity expected from the beam at the Long-Baseline Neutrino Facility (LBNF): 35 modules, each containing two optically separated time projection chambers, are instrumented with a pixel-based, true 3D charge readout alongside scintillation light traps to disentangle the O(100) interactions expected per 10us beam spill. A robust prototyping program supports ND-LAr’s design: the 2x2 Demonstrator consists of four scaled-down ND-LAr modules exposed to the NuMI beam at Fermilab, and the Full Scale Demonstrator (FSD) is a single ND-LAr module tested with cosmic rays at the University of Bern. We present here an analysis of minimum ionizing particle (MIP) tracks selected from 2x2 beam data and FSD cosmic ray data used to benchmark the pixel-based charge readout simulation and calibration in both detectors, with the ultimate goal of validating the design of DUNE ND-LAr as well as informing future calibration methods. This poster will showcase the dependence of the charge response on track inclination as well as a per-pixel dQ/dX extraction.

Mandujano, Roberto [UC, Irvine]↗

The Deep Underground Neutrino Experiment (DUNE) Program

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment aimed at determining the neutrino mass hierarchy and the CP-violating phase. The DUNE physics program also includes the detection of astrophysical neutrinos and the search for signatures beyond the Standard Model, such as nucleon decays. DUNE consists of a near detector complex located at Fermilab and four 17 kton Liquid Argon Time Projection Chamber (LArTPC) far detector modules to be built 1.5 km underground at SURF, approximately 1300 km away. The detectors are exposed to a wideband neutrino beam generated by a 1.2 MW proton beam with a planned upgrade to $>$ 2 MW. Two 770 ton LArTPCs (ProtoDUNEs) have been operated at CERN for over 2 years as a testbed for DUNE far detectors and have been optimized to take new cosmic and test-beam data in 2024-2025. The DUNE and ProtoDUNE experiments and physics goals, as well as recent progress and results, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct cross-section measurement of the weak r -process Sr 88 ( α , n ) Zr 91 reaction in ν -driven winds of core-collapse supernovae

About half of the heavy elements beyond iron are known to be produced by the rapid neutron capture process, known as the r process. However, the astrophysical site producing the r process is still uncertain. Chemical abundances observed in several cosmic sites indicate that different mechanisms should be at play. For instance, the abundances around silver measured in a subset of metal-poor stars indicate the presence of a weak r process. This process may be active in neutrino-driven winds of core collapse supernovae where (α,n) reactions dominate the synthesis of Ζ ≈ 40 elements in the expelled materials. Scarcely measured, the rates of (α,n) reactions are determined from statistical Hauser-Feshbach calculations with α-optical-model potentials, which are still poorly constrained. Further, the uncertainties of the (α,n) reaction rates therefore make a significant contribution to the uncertainties of the abundances determined from stellar modeling. In this work, the 88 Sr (α,n)⁢ 91 Zr reaction which impacts the weak r-process abundances has been probed at astrophysics energy for the first time; directly measuring the total cross sections at astrophysical energies of 8.37–13.09 MeV in the center of mass (3.8–7.5 GK). Two measurements were performed at ATLAS with the electrically segmented ionization chamber MUSIC, in inverse kinematics, while following the active target technique. The cross sections of this α-induced reaction on 88 Sr, located at the shell closure N = 50, have been found to be lower than expected, by a factor of 3, despite recent statistical calculations validated by measurements on neighboring nuclei. This result encourages more experimental investigations of (α,n) reactions, at Ν = 50 and towards the neutron-rich side, to further test the predictive power and reliability of such calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effect of ICRH and NBI on tungsten transport in neon edge radiation cooled discharges in TEXTOR

Tungsten is planned to be the plasma-facing material for the main chamber and divertor in future devices like ITER, SPARC, and DTT. To address risks associated with tungsten, R&D is being carried out on various toroidal confinement devices. One particular research question is related to the optimum heating mix for ITER. To investigate the influence of the heating scheme on the release and transport of tungsten, a comparison of neutral beam injection (NBI) and ion cyclotron resonance frequency (ICRF) heating was carried out in TEXTOR tungsten test limiter experiments. The experiments were performed under standard L-mode conditions and in radiative improved-mode operation with neon seeding and boronized walls covering the graphite plasma-facing components. The plasma was heated with hydrogen or deuterium NBI alone or with deuterium NBI in combination with H-minority, ion cyclotron resonance heating. A movable solid tungsten limiter was inserted through a limiter lock system into the edge plasma. The impurity release from this limiter was evaluated from visible spectroscopy. The tungsten concentrations in the plasma core were determined by extreme ultraviolet spectroscopy and bolometry. With deuterium NBI alone, strong central radiation and accumulation of W was observed. This can, however, be avoided by adding ICRF heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

Characterization of UV optical components for photon detector calibration in liquid argon TPCs

Large liquid argon time projection chambers (LArTPCs)require stable and well-characterized delivery of ultraviolet (UV)light for in situ calibration of photosensors at cryogenictemperatures. This article reports bench-top and cryogenicmeasurements of the optical components used in a UV lightcalibration system, including multi-mode fused-silica fibers,SMA-to-SMA connectors, optical fiber feedthroughs, andlight-diffuser assemblies. Light loss in several fiber types and SMAconnectors was measured across wavelengths from275–970 mm. In addition,light-loss measurements of the tested fibers after severalliquid-nitrogen thermal cycles showed no statistically significantdegradation relative to baseline measurements, and high-rate pulsedexposure (30–90 million pulses from a275 nm LED) likewise showed nomeasurable aging in jacketed fibers. A compact, palm-sized,3D-printed PEEK diffuser housing with stacked UV-grade fused-silicadiffusers yields Lambertian emission and the most uniform angulardistribution. Optical components exhibiting improved UV transmissionwere deployed successfully in multiple DUNE small- and large-scaleprototypes, demonstrating reliable operation of UV light calibrationsystem. These findings inform component selection and calibrationprocedures for achieving reliable, uniform UV light delivery inlarge-scale cryogenic detectors such as DUNE.

Behera, B. [South Dakota Sch. Mines Tech.] (ORCID:↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗