At least 145 records · Page 8

Shields-1 Energetic Proton Dose Comparison from Solar Minimum and Active Periods

Shields-1 has been operating in polar low earth orbit since December 2018 as part of the CubeSat Launch Initiative (CSLI) Educational Launch of Nanosatellites (ELaNa)XIX Mission. Shields-1 has 8 Teledyne µdosimeters behind shielding. These shielded µdosimeters have high minimum proton energy thresholds. The Shields-1 electronics enclosure µdosimeter has a minimum proton threshold energy of 151 MeV. The annualized total ionizing dose (TID) in the electronics enclosure was 75.6 +/- 3.2 RAD from July-August 2019, which was a solar minimum period. In contrast, the annualized TID was 61.0 +/- 2.5 RAD in July 2023, a solar active month. The TID change can be attributed to both the reduction in radiation at the South Atlantic Anomaly (SAA) and the decrease in galactic cosmic radiation during increasing solar activity. The measured GCR dose over the poles was reduced during the July 2023 solar active period in comparison with the July 2019 solar minimum period, using the most sensitive µdosimeter channel for the measurement. Shields-1 has demonstrated the capability of measuring the changes in high energy protons in polar low earth orbit during changes in solar activity, which contributes to the understanding of Earth in the heliosphere.

Shields-1 Dosimetry Space Sciences↗

Solid State Drive Radiation Assurance With Active Testing

Single-event effects (SEE) and total ionizing dose (TID) data are presented for several automotive- and industrial-grade solid-state drives, and the effects of different active test configurations on hardness assurance are explored.

dose↗

Standards for Radiation Effects Testing: Ensuring Scientific Rigor in the Face of Budget Realities and Modern Device Challenges

An overview is presented of the space radiation environment and its effects on electrical, electronic, and electromechanical parts. Relevant test standards and guidelines are listed. Test standards and guidelines are necessary to ensure best practices, minimize and bound systematic and random errors, and to ensure comparable results from different testers and vendors. Test standards are by their nature static but exist in a dynamic environment of advancing technology and radiation effects research. New technologies, failure mechanisms, and advancement in our understanding of known failure mechanisms drive the revision or development of test standards. Changes to standards must be weighed against their impact on cost and existing part qualifications. There must be consensus on new best practices. The complexity of some new technologies exceeds the scope of existing test standards and may require development of a guideline specific to the technology. Examples are given to illuminate the value and limitations of key radiation test standards as well as the challenges in keeping these standards up to date.

Test Standard↗

Radiation 101: Effects on Hardware and Robotic Systems

We present basic information on different types of radiation effects, including total ionizing dose, displacement damage, and single-event effects. The content is designed to educate space weather professionals, space operations professionals, and other science and engineering stakeholders.

non-ionizing energy loss (NIEL)↗

Radiation 101: Effects on Hardware and Robotic Systems

We present basic information on different types of radiation effects, including total ionizing dose, displacement damage, and single-event effects. The content is designed to educate space weather professionals, space operations professionals, and other science and engineering stakeholders.

radiation effects↗

The Living With a Star Space Environment Testbed Payload

This presentation outlines a brief description of the Living With a Star (LWS) Program missions and detailed information about the Space Environment Testbed (SET) payload consisting of a space weather monitor and carrier containing 4 board experiments.

Total Ionizing Dose (TID)↗

Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the design margin concept with one of failure probability.

radiation hardness assurance↗

Recent Advances and Future Challenges in Risk-Based Radiation Engineering

We cover a top-level introduction to hardness assurance (HA) from a robotic space system perspective, starting at the piece-part level. We discuss error sources inherent to presently-accepted HA practices and why they cause us to be risk-averse. We conclude by reviewing current proposals that move towards more risk-tolerant system design approaches as well as future challenges that will require these advanced techniques.

radiation effects↗

Total Ionizing Dose Test Report BFR92A NPN 5 GHz Wide Band Transistor from NXP

The purpose of this test was to characterize the Philips/NXP BFR92A NPN 5 gigahertz wide band silicon transistor for total dose response. This test shall serves as the radiation lot acceptance test (RLAT) for the lot date code (LDC) 1027. The BFR92A is packaged in a 3-pin plastic SOT23 package. Low dose rate (LDR/ELDRS) irradiations was performed.

Total Ionizing Dose (TID)↗

LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

total ionizing dose (TID)↗

Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator

The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).

enhanced low dose rate sensitivity (ELDRS↗