Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Preparation and characterization of electrodes for the NASA Redox storage system

Electrodes for the Redox energy storage system based on iron and chromium chloride reactants is discussed. The physical properties of several lots of felt were determined. Procedures were developed for evaluating electrode performance in lab scale cells. Experimental procedures for evaluating electrodes by cyclic voltammetry are described which minimize the IR losses due to the high internal resistance in the felt (distributed resistance). Methods to prepare electrodes which reduced the coevolution of hydrogen at the chromium electrode and eleminate the drop in voltage on discharge occasionally seen with previous electrodes were discussed. Single cells of 0.3329 ft area with improved membranes and electrodes are operating at over 80% voltage efficiency and coulombic efficiencies of over 98% at current densities of 16 to 20 amp % ft.

Reid, M. A.↗

Prototype Software for Future Spaceflight Tested at Mars Desert Research Station

NASA scientists in MDRS Crew 49 (April 23-May 7, 2006) field tested and significantly extended a prototype monitoring and advising system that integrates power system telemetry with a voice commanding interface. A distributed, wireless network of functionally specialized agents interacted with the crew to provide alerts (e.g., impending shut-down of inverter due to low battery voltage), access md interpret historical data, and display troubleshooting procedures. In practical application during two weeks, the system generated speech over loudspeakers and headsets lo alert the crew about the need to investigate power system problems. The prototype system adapts the Brahms/Mobile Agents toolkit to receive data from the OneMeter (Brand Electronics) electric metering system deployed by Crew 47. A computer on the upper deck was connected to loudspeakers, four others were paired with wireless (Bluetooth) headsets that enabled crew members to interact with their personal agents from anywhere in the hab. Voice commands and inquiries included: 1. What is the {battery | generator} {volts | amps | volts and amps}? 2. What is the status of the {generator | inverter | battery | solar panel}? 3. What is the hab{itat} {power usage | volts | voltage | amps | volts and amps}? 4. What was the average hab{itat} {amps | volts | voltage} since <#> {AM | PM)? 5. When did the {generator | batteries} change status? 6. Tell {me I | everyone} when{ ever} the generator goes offline. 7. Tell {me | | everyone} when the hab{itat} {amps | volts | voltage} {exceeds | drops brelow} <#>. 8. {Send | Take | Record} {a} voice note {(for | to} } {at }. This research demonstrates the principles of design in the context of use, investigating requirements through experimental use of prototype systems in an analog setting, and use of MDRS as a research facility for designing and implementing new systems.

Clancey, William J.↗

Response of a metal-oxide-semiconductor field-effect transistor to a cosmic-ray ion track

A cosmic-ray ion track passing perpendicularly through the oxide layer of an enhancement-mode metal-oxide-semiconductor field-effect transistor (MOSFET) forms a conducting path, the resistance of which is proportional to the stopping power of the cosmic ion and independent of the cross-sectional area of the ion track. The voltage across the oxide capacitance may drop below the threshold voltage if the gate bias is sufficiently low or if the external resistance in the gate-source circuit is sufficiently high. The first of a pair of MOSFETs forming a flip-flop circuit may thus be turned off, and the second transitor may turn on, providing it has a sufficiently short delay time, thereby completing a single-event upset.

Benumof, Reuben↗

Voltage monitoring system

A description is given of a system for monitoring the voltage at a remote location and determining when the voltage exceeds upper and lower levels. The system includes transmission lines for transmitting the voltage back to a central station and applying such to an amplifier having a pair of outputs. One of the outputs of the amplifier is applied to an oscillograph. The other output is fed through an isolation transformer, a full wave rectifier, to a pair of unijunctional transistor circuits for producing pulses when the voltage exceeds or drops below a predetermined level. These pulses, in turn, energize a relay which turns on the oscillograph for recording the voltages being monitored.

Canicatti, C. L.↗

Next Generation of Hall Thrusters for Space Propulsion

During the previous year, grant activity research focused on demonstrating high thrust/power operation of Hall thrusters. Performance of a low power and a high power Hall thruster was experimentally investigated at discharge voltages from 100 to 150 volts. Discharge efficiencies dropped significantly as discharge voltage was decreased over this range. Reductions in discharge efficiency with decreasing discharge voltage were attributed to reductions in ionization efficiency and/or ion acceleration through a potential less that the applied discharge voltage relative to the performance of state-of-art Hall thrusters operating at discharge voltages of 300 Volts and above. The low power Hall thruster exhibited a more pronounced reduction in discharge efficiency with decreasing discharge voltage. This was attributed to increased electron leakage related to the axial distribution of the radial magnetic field. These data demonstrated that the thrust benefit of operating at discharge voltages below 130 Volts was offset by a corresponding decrease in discharge efficiency for a given input power. Additional activities included continued support of on-going Hall thruster propulsion research within the On-Board Propulsion Branch at NASA Glenn Research Center.

Keith, Theo G., Jr.↗

Soft-short management and remediation in 10-year-old NiCds in Geo orbit

After 10 years in Geo orbit, during the spring 1993 eclipse season, soft shorts occurred in cells of two of the three batteries on the F2R spacecraft On battery #1, the cell soft short turned suddenly into a hard short; the resulting sudden 1.2V fall in battery voltage and rise in temperature was observed via telemetry. On battery #3, the deleterious impact of its soft short increased day by day, manifesting itself as a drop in battery voltage part-way through each eclipse, causing high loading on the remaining good battery. This paper reports how by planned charge management, including applying (against-the-book) overcharge ratios (C/D) exceeding 1.75, the battery #3 cell soft short was 'built down' until the cell voltage fade ceased. The problem with the battery #3 soft-shorted cell was fought with partial success throughout the latter half of the fall 93 season, and the lessons learned were applied to alleviate the problem during the spring 94 and fall 94 eclipse seasons. The life of the spacecraft was successfully prolonged until it was retired in March 1995.

Flordeliza, Nicanor A.↗

Characterization of Low Noise, Precision Voltage Reference REF5025-HT Under Extreme Temperatures

The performance of Texas Instruments precision voltage reference REF5025-HT was assessed under extreme temperatures. This low noise, 2.5 V output chip is suitable for use in high temperature down-hole drilling applications, but no data existed on its performance at cryogenic temperatures. The device was characterized in terms of output voltage and supply current at different input voltage levels as a function of temperature between +210 C and -190 C. Line and load regulation characteristics were also established at six load levels and at different temperatures. Restart capability at extreme temperatures and the effects of thermal cycling, covering the test temperature range, on its operation and stability were also investigated. Under no load condition, the voltage reference chip exhibited good stability in its output over the temperature range of -50 C to +200 C. Outside that temperature range, output voltage did change as temperature was changed. For example, at the extreme temperatures of +210 C and - 190 C, the output level dropped to 2.43 V and 2.32 V, respectively as compared to the nominal value of 2.5 V. At cryogenic test temperatures of -100 C and -150 C the output voltage dropped by about 20%. The quiescent supply current of the voltage reference varied slightly with temperature but remained close to its specified value. In terms of line regulation, the device exhibited excellent stability between -50 C and +150 C over the entire input voltage range and load levels. At the other test temperatures, however, while line regulation became poor at cryogenic temperatures of -100 C and below, it suffered slight degradation at the extreme high temperature but only at the high load level of 10 mA. The voltage reference also exhibited very good load regulation with temperature down to -100 C, but its output dropped sharply at +210 C only at the heavy load of 10 mA. The semiconductor chip was able restart at the extreme temperatures of -190 C and +210 C, and the limited thermal cycling did not influence its characteristics and had no impact on its packaging as no structural or physical damage was observed.

Patterson, Richard↗

Double layer formation during current sheet disruptions in a reconnection experiment

When the current density in the center of a neutral sheet is increased to a critical value spontaneous current disruptions are observed. The release of stored magnetic field energy results in a large inductive voltage pulse which drops off inside the plasma in the form of a potential double layer. Particles are energized, microinstabilities are generated, the plasma is thinned, and the current flow is redirected. These laboratory observations qualitatively support recent models of magnetic substorms and solar flares.

Stenzel, R. L.↗

Impedance of silver oxide-zinc cells

Over 100 sealed AgO-Zn cells were subjected to prolonged periods of storage over a range of temperatures and storage modes including open circuit, trickle charge, and float charge. Impedances of these cells were monitored throughout, and at the end of the storage period their transient voltage characteristics were observed at the onset of discharge. Results revealed that the impedances of these cells tended to increase with storage time; the magnitude of the impedance rise was dependent primarily on temperature and to a lesser degree on storage mode. Typical values for 50 A-hr cells were usually less than 100 mohm immediately after activation and from 1 to 30 ohm after 6-10 months of storage. Transient voltages of these cells droped sharply during the first msec of discharge and then rose to a stablized value during the following few seconds. The magnitude of the initial drop and the stabilized voltage values were found to be related to impedance but not in a linear manner. The magnitude and duration of the low transient voltages may be unacceptable in some applications of these cells. The impedance variations are attributed to changes occurring at the positive electrode.

Frank, H. A.↗

Improvements in contact resistivity and thermal stability of Au-contacted InP solar cells

Specific contact resistivities for as-fabricated Au contacts on n-p InP solar cells are typically in the 10(exp -3) ohm/sq cm range, but contact resistivities in the 10(exp -6) ohm/sq cm range can be obtained if the cells are heat treated at 400 C for a few minutes. This heat treatment, however, results in a dramatic drop in the open circuit voltage of the cell due to excessive dissolution of the emitter into the metallization. It was found that low values of contact resistivity can be secured without the accompanying drop in the open circuit voltage by adding Ga and In in the Au metallization. It is shown that Au contacts containing as little as 1 percent atomic Ga can suppress the reaction that takes place at the metal-InP interface during heat treatment, while exhibiting contact resistivity values in the low 10(exp -5) ohm/sq cm. Detailed explanations for the observed superior thermal stability of these contacts are presented.

Fatemi, Navid S.↗

A Simple Thermoelectric Droplet Generator

A new design for a droplet generator capable of producing single droplets is presented. The design relies on thermoelectric heating to vaporize water at the interface between a droplet and a blunt syringe tip. While other designs require careful tuning to produce drops of varying size, this technique enables the simple creation of droplets of any size within a range. The design is of simple construction and can be completed with off-the-shelf components, and relies on resistive heating to vaporize water at or near the droplet-nozzle interface and release the droplets. We demonstrated that the design can be used to produce droplets as small as 110 µm or as large as 2 mm. Drop size is limited by the geometry of the nozzle since water must wet the tip of the nozzle and hang under gravity. Our experiments showed that released droplets have relatively small disturbances introduced by the release mechanism when compared to competing techniques. These disturbances were intermittently observed as the voltage, pulse width, and drop size were changed, and optimal settings were determined for the smallest drop sizes produced.

Andrew Work↗

Superlattices and multilayer structures for high efficiency solar cells

Possible applications of superlattices to photovoltaic structures are discussed. A new concept based on doping superstructures (NIPI) can be exploited to significantly reduce recombination losses in III-V compound solar cells. A novel multijunction structure with lateral current transport is proposed. A computer simulation has been performed which shows that by optimizing the multilayer structure, short circuit current is substantially increased with minimum drop in open circuit voltage. An additional advantage of the structure is enhanced radiation tolerance. It is anticipated that this multilayer structure can be incorporated in multibandgap cells to achieve high efficiencies.

Wagner, M.↗

Effect of field-aligned potential drop in a global magnetosphere-ionosphere coupling model

Effects of field-aligned potential drops on the magnetosphere-ionosphere coupling in a steady state are studied on a global ionospheric scale. It is shown that a constant-current generator can support a larger field-aligned potential drop than a constant voltage generator under similar conditions. The magnetospheric convection pattern is distorted more in the constant current generator case than in the constant voltage generator case. The main difference between a constant current generator and a constant voltage generator is found to lie in their ability to adjust the vorticity of the magnetospheric convection. The results show that a constant current generator allows the vorticity of the magnetospheric convection to adjust so that the field-aligned current can be kept constant under the loading influence of the field-aligned potential. On the other hand, a constant voltage generator by definition cannot adjust the vorticity of the magnetospheric convection to maintain the field-aligned current under the loading influence of the field-aligned potential.

Kan, J. R.↗

High current compensation network for dc logarithmic amplifiers

Circuit voltage output is reduced by voltage equivalent to ampere resistance drop of nonlogarithmic resistances of practical diodes; therefore, output is same as circuit using ideal diode. Circuit applies to meter and electronic recorder movements, and improves performance of radiation detectors and several microbiological monitoring devices

Wilson, J. H.↗

FEP encapsulated N/P silicon solar cells after simulated micrometeoroid exposure.

The effects of simulated micrometeoroid exposure on the performance of N/P silicon solar cells encapsulated for their protection in fluorinated ethylene propylene were determined in a shock tube. It was found that the short-circuit current decreased after exposure to the simulated micrometeoroid particles. The shape of the curve remained the same and was simply translated downward with a concomitant drop in open-circuit voltage.

Mirtich, M. J.↗

Results of a 1462 hour ammonia arcjet endurance test

A total of 1462 hours of operaton were demonstrated in an endurance test of a 30 kWe-class ammonia arcjet operated at 10 kWe. The propellant flow rate was 0.170 g/s, and the measured performance increased from approximately 650 s specific impulse at 36 percent efficiency at the beginning of the test to 675 s at 39 percent near the end. The voltage increased and the current dropped slightly over the first 400 hours, and then remained approximately constant for the remainder of the test. The test, scheduled for 1500 hours, was terminated after an insulator in the rear of the engine failed. Post-test examination of the electrodes revealed only minimal damage. Although there was evidence of a number of mass transport processes occurring in the discharge chamber, the primary life-limiting wear mechanisms appear to be cathode tip erosion and constrictor melting.

Polk, J. E.↗

Martian Atmospheric Pressure Static Charge Elimination Tool

A Martian pressure static charge elimination tool is currently in development in the Electrostatics and Surface Physics Laboratory (ESPL) at NASA's Kennedy Space Center. In standard Earth atmosphere conditions, static charge can be neutralized from an insulating surface using air ionizers. These air ionizers generate ions through corona breakdown. The Martian atmosphere is 7 Torr of mostly carbon dioxide, which makes it inherently difficult to use similar methods as those used for standard atmosphere static elimination tools. An initial prototype has been developed to show feasibility of static charge elimination at low pressure, using corona discharge. A needle point and thin wire loop are used as the corona generating electrodes. A photo of the test apparatus is shown below. Positive and negative high voltage pulses are sent to the needle point. This creates positive and negative ions that can be used for static charge neutralization. In a preliminary test, a floating metal plate was charged to approximately 600 volts under Martian atmospheric conditions. The static elimination tool was enabled and the voltage on the metal plate dropped rapidly to -100 volts. This test data is displayed below. Optimization is necessary to improve the electrostatic balance of the static elimination tool.

Johansen, Michael R.↗

Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

Bever, R. S.↗