Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water infrastructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Higher Energy-Content Jet Blending Components Derived from Ethanol (CRADA 467)

This project aims to develop a new sustainable aviation fuel (SAF) that comprises favorable properties, such as high energy density, excellent thermal stability, and favorable cold fold properties. Through catalyst development, this work will provide a route to control the cycloalkane/n-alkane/iso alkane content of a next-generation fuel with minimal or no aromatic content. Combining n-alkane and iso-alkane streams (high specific energy, MJ/kg) with cycloalkanes (higher energy density, MJ/L), is expected to enable at least a 4% net increase in combined (specific (MJ/kg) and volumetric (MJ/L)) energy content without impacting ‘drop-in’ fuel requirements, such as seal swelling. PNNL and LanzaTech have already demonstrated a sustainable, non-petroleum, route to isoalkanes. However, economically attractive cycloalkane production from waste and biomass is challenged by large hydrogen requirements, preferential selectivity to aromatic compounds and low yields to jet fuel range components. Many gaps in understanding cycloalkane properties and performance in complex jet fuel mixtures remain. The close tie and integration of Purdue’s fuel property analysis, with PNNL’s process development, can lead to an economically attractive process. The fuel analysis and testing by Purdue will enable a robust understanding of the properties and behavior of the cycloalkanes produced to inform process development. Additionally, seal-swelling analysis will quantify the ability of fuel blends with zero or minimal aromatics content to satisfy the seal swell requirement of O rings. Lastly, Purdue’s system-level analysis will lead to the development of a roadmap for deployment in key regions that considers system pressures such as hydrogen, water, energy efficiency, and ease of infrastructure access.

10 SYNTHETIC FUELS↗

Non-Powered Dam Custom Analysis and Taxonomy (NPDamCAT) Framework

Over 85,000 non-powered dams (NPDs) exist in the United States that provide services such as flood control, navigation, and water storage for irrigation/domestic water use (USACE 2019). The existing infrastructure of NPDs poses an opportunity for improving economic and environmental performance and generating electricity, as well as a challenge for maintaining aging structures and remediating fragmented river systems. NPD stakeholders interested in the rehabilitation, retrofit, or removal of NPDs must have the relevant information about the population of dams to support decision-making. Each NPD has unique characteristics describing its design, operation, environmental impacts, social impacts, and economic potential. The large number of dams, the diversity of interests related to dams, the variety of dam characteristics, and the types of data required to describe dams all pose major challenges to an analysis of the entire dam population.

13 HYDRO ENERGY↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

Empowering Critical Infrastructure Communication with Secure 5G Private Networks

With the transformational New Radio- Unlicensed (NR-U), 5G network can be operated with unlicensed and shared spectrum. Private 5G networks without any licensed bands, which are both highly expensive and usually available to only large commercial wireless providers, can now be used for a whole range of new applications including smart factories, warehouses, connected cars and drones. 5G’s support of a) massive machine type communication (mMTC) for a large number of connected devices with b) ultra-reliable low latency communication (URLLC) capability when needed, and c) up to 20 times higher data rate with enhanced mobile broadband (eMBB) than previously available, enables new and powerful capabilities in a wireless network. While these capabilities are transformational, necessary security and reliability requirements have to be satisfied when used in critical infrastructure such as factories, power plants, water systems, ports, and other industrial facilities. 5G standards have introduced significant security improvement over 4G/LTE as well as mitigations for new attack surfaces created by changes in the 5G network. This talk will discuss these security improvements and whether they meet the security properties required for mission critical communication over wireless.

5G↗

Hydropower Potential at Non-Powered Dams: A Multi-Criteria Decision Analysis Tool based on Grid, Community, Industry, and Environmental Impacts

Non-powered dams (NPDs) are dams that do not include hydraulic turbine (hydropower) equipment. Currently, there are more than 80,000 such dams in the United States, which provide a variety of non-energy benefits, including flood control, water supply, navigation, and recreation. Approximately 500 of these NPDs are identified as having the potential to add hydropower generation (totaling up to a capacity of more than 8200 MW). A large share of investment costs and environmental impacts of dam construction have already been incurred at these NPDs. Hence, adding power to the existing dam structure is hypothesized to be achieved at a lower cost, with less risk, and a shorter timeframe than the development required for new dam construction. The abundance of NPDs, the associated environmental favorability, and cost advantages, combined with the reliability, predictability, and dispatchability of hydropower, make NPDs a strong candidate in the nation’s renewable energy portfolio. To assess the NPD to hydropower conversion potential, in this study, we developed a GIS-based multi-criterial decision analysis tool, which allows users to rank these NPDs based on the grid, community, industry, and environmental impacts (i.e., GCIE impacts). This web-based interactive tool (developed using open-source Python and JavaScript) lets the user choose from a wide range of features to define each of the GCIE impact scores through a user-friendly graphical user interface. These features are related to dam operation, hydropower generation opportunity, power market economy, social vulnerability and risk, proximity to critical infrastructure and energy generating facilities, environmental concerns (air, water, and critical habitat), and exposure to natural hazards. The overall priority score of NPDs is calculated based on user-defined weights for each of the GCIE impact scores. Besides ranking NPDs, the tool can also be used to estimate the energy-storage feasibility (battery, hydrogen, and pump-storage hydropower) at each of the potential sites.

13 HYDRO ENERGY↗

Grassland productivity responds unexpectedly to dynamic light and soil water environments induced by photovoltaic arrays

Abstract Agrivoltaic (AV) systems are designed to coproduce photovoltaic (PV) energy on lands simultaneously supporting agriculture (food/forage production). PV infrastructure in agroecosystems alters resources critical for plant growth, and water‐limited agroecosystems such as grasslands are likely to be particularly sensitive to the unique spatial and temporal patterns of incident sunlight and soil water inherent within AV systems. However, the impact of resource alteration on forage production, the primary ecosystem service from managed grasslands, is poorly resolved. Here, we evaluated seasonal patterns of soil moisture (SM) and diurnal variation in incident sunlight (photosynthetic photon flux density [PPFD]) in a single‐axis‐tracking AV system established in a formerly managed semiarid C 3 grassland in Colorado. Our goals were to (1) quantify dynamic patterns of PPFD and SM within a 1.2 MW PV array in a perennial grassland, and (2) determine how aboveground net primary production (ANPP) and photosynthetic parameters responded to the resource patterns created by the PV array. We hypothesized that spatial variability in ANPP would be strongly related to SM patterns, typical of most grasslands. We measured significant reductions in ANPP directly beneath PV panels, where SM and PPFD were both low. However, in locations with significantly increased SM from the shedding and redistribution of precipitation by PV panels, ANPP was not increased. Instead, ANPP was greatest in locations where plants were shaded in the afternoon but received high levels of PPFD in the morning hours, when air temperatures and vapor pressure deficits were relatively low. Thus, contrary to expectations, we found relatively weak relationships between SM and ANPP despite significant spatial variability in both. Further, there was little evidence that light‐saturated photosynthesis ( A sat ) and quantum yield of CO 2 assimilation (ϕCO 2 ) differed for plants growing directly beneath (lowest PPFD) versus between (highest PPFD) PV panels. Overall, the AV system established in this semiarid managed grassland did not alter patterns of ANPP in ways predictable from past studies of controls of ANPP in open grasslands. However, our results suggest that the diurnal timing of low versus high periods of PPFD incident on plants is an important determinant of productivity patterns in grasslands.

14 SOLAR ENERGY↗

Strengthening the Security of Operational Technology: Understanding Contemporary Bill of Materials

The evolution of cyber-physical infrastructure has made its security more challenging. The last few years have witnessed a convergence of hardware and software segments in various domains, including operational technology (OT) which is responsible for carrying out critical tasks such as monitoring and controlling power grids, nuclear plants, transportation, and emergency services. Both hardware and software encapsulate numerous open source and proprietary subcomponents, making it crucial for end-users to understand the composition of the products they are using. For example, wind turbines incorporate thousands of lines of code (software) used for the turbine's design, planning, operation, and analytics in addition to the numerous hardware subcomponents that construct it. Due to the highly complex nature of software and hardware, knowledge of the components and subcomponents is required to mitigate cyber vulnerabilities and defend against cyberattacks. There has also been a transformation from a traditional linear supply chain into a global, dynamic, diverse, and interconnected system. The digitization of the supply chain makes it easier to find and exploit vulnerabilities. Critical infrastructures (e.g., power grids, oil, natural gas, water, and wastewater) rely on OT to function, and if the OT is compromised, equipment damage and potential interruption of services could result. A significant security measure to protect OT systems from disruption is to develop a supply chain bill of materials (BoM) corresponding to the software and hardware used in OT, along with attestations amongst vendors and asset owners. A supply chain BoM is a proactive way to understand the inherent vulnerabilities in the system and mitigate them in advance of being exploited. BoMs bolster the trust placed in the digital infrastructure and enhance software supply chain security by sustaining the management of component obsolescence and compliance, along with the seclusion of unsafe segments of a specific product. Adopting BoM tools is becoming increasingly important across various government sectors, as evidenced by the recent U.S. executive order on cybersecurity (NIST 2021). This paper aims to classify BoMs based on structure, functionality, component type, and architecture. The work also discusses case studies to further highlight the benefits of BoMs. In addition, it identifies missing pieces in existing BoM implementations so that future research may identify bounds on where it could expect to make improvements and directly enable researchers to identify promising areas for exploration. Further, the authors provide valuable recommendations to tool developers, researchers, and standardizing organizations (policymakers), additionally benefitting critical infrastructure owners and government executives. This aids in paving a path for future work, thereby, providing suggestions to determine a tool for consumers that best suit their needs.

97 MATHEMATICS AND COMPUTING↗

Geologic Assessment and Recommended New Well Locations to Improve the Area 25 Potable Water System, Nevada National Security Site

The Mission Support and Test Services, LLC (MSTS) Geoscience Operations Group performed a hydrogeologic study of an area of interest in Area 25 at the request of the MSTS Enterprise Infrastructure Program to identify potential locations for a new water well to replace J-14 Water Well (J-14 WW). Based on limited subsurface hydrogeologic data for the area, geologists developed two options for construction of a new well. Option 1 is to construct the well within approximately 250 feet (ft) of J-14 WW, and Option 2 is to construct the well approximately 1,550 ft north of J-11 Water Well (J-11 WW). Option 1 may be preferred, as the hydrogeology is better understood adjacent to an existing well. A well drilled at the Option 2 location would not have to be as deep as that at the Option 1 location, but the hydrogeologic setting is more uncertain at this greater distance from a verified subsurface geologic data point.

58 GEOSCIENCES↗

Resilience assessment and planning in power distribution systems: Past and future considerations

High impact low probability (HILP) events such as hurricanes, heat waves, and floods have instigated widespread power outages and blackouts around the globe in the past decade. With the increasing challenges concerning the threats to the power distribution systems and the growing need to mitigate the impacts of the HILP events, resilience has become a crucial requirement for the power grid infrastructures. Numerous efforts have been made to define, measure, and characterize the resilience of power distribution systems. This study thoroughly reviews the state-of-the-art methods on the existing resilience evaluation framework and metrics. Here, the desirable characteristics of resilience metrics are highlighted, and the challenges associated with formulating, developing, and calculating such metrics are discussed. Next, we detail the state-of-the-art literature on planning solutions to ensure distribution system resilience. This paper aims to extract a deep insight into this challenging and critical research area and envision future opportunities that can guide the power distribution system operators/planners to formulate more effective mitigation strategies to enhance the resilience of power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

Primer to SWIFt 2.0 Technical Information Sheets

More than 16,000 publicly owned municipal wastewater treatment plants (WWTPs) in the U.S. treat a wide range of wastewater (WW) flows ranging from <0.5 to >200 MGD. Municipal WWTPs act as the last barrier before exposure to water-borne diseases and contaminants, thus serving as a critical infrastructure protecting human health and the environment. A recent survey by the American Society of Civil Engineers assigned the U.S.’s WW infrastructure a grade of D+ because of the number of improvements needed for end-of-life infrastructure with operating conditions being over or under design capacities. With increasing population growth and urbanization, the municipal WW sector needs to grow resiliently and sustainably to accommodate increasing sewer flows in the wake of new infrastructure needs and global priorities. In addition, this growth will be affected by rising concerns over constrained resources (e.g., electricity, energy, and water) and regulations. This necessitates molding the WW sector toward sustainability- and resiliency-related planning and innovations to address current and future needs while simultaneously producing profitable by-products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NEWTS Well Summary by Hydrologic Regions and Subbasins in the U.S.

Oil and gas well production data (2000-2022), including water production and injection, as well as summary information (e.g., well count by status, total vertical depth statistics, etc.) spatially summarized by Watershed Boundary Dataset's (WBD) region (Hydrologic Unit Code (HUC) 2) and subbasin (HUC8). Energy-related produced waters data were acquired and summarized in support of the development of the National Energy Technology Laboratory's NEWTS (National Energy Water Treatment and Speciation Database). Due to the proprietary nature of the wellbore data, this derived product has been spatially compiled by key areas to support research and stakeholder needs.

Energy Infrastructure↗

Reanalysis of Water Withdrawal for Irrigation, Electric Power, and Public Supply Sectors in the Conterminous United States, 1950–2016

Accurately measuring water use by the economy is essential for developing reliable models of water resource availability. Indeed, these models rely on retrospective analyses that provide insights into shifting human population demands and adaptions to water shortages. However, accurate, methodologically consistent, empirically authentic, and spatiotemporally comprehensive historical datasets for water withdrawals are scarce. Herein, we present a reanalysis of annual resolution (1950–2016) historical data set on irrigation, electric power, and public supply water withdrawal within the conterminous United States (US) at the county-level, and, for power plants, at the site-level. To estimate electric power water use, we synthesized a historically comprehensive list of generators and historic patterns in generation across fuels, prime movers, and cooling technologies. Irrigation water use estimation required building a crop-demand model that utilized historical information on irrigated acreage for crops and golf courses, stage-specific crop water demand, and climate information. To estimate public water supply use, we developed a random forest model constructed from information on population, infrastructure, climate, and land cover. These estimates generally agree with total county and state water use information provided by the US Geological Survey (USGS) water use circular and estimates generated from independent studies for specific years. However, we also observed discrepancies between our estimates and USGS data that appear to be caused by inconsistencies in the methods used by the USGS's primary data sources at the state level over decades of data collection, highlighting the importance of reanalysis to yield spatiotemporally consistent and intercomparable estimates of water use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resilience Assessment: Cape Cod National Seashore

The NPS partnered with the National Renewable Energy Laboratory (NREL) in 2019 to develop resilience plans at specific high-risk parks as well as a resilience planning guide to inform resilience planning decisions by NPS and other federal land management agencies. The purpose of this project is to further examine the vulnerability of coastal park infrastructure specific to energy, communications, transportation, and water systems, for future operational resilience across the NPS portfolio. Leveraging previously compiled vulnerability assessments and renewable energy analyses, NREL has completed resilience plans at specific high-risk pilot parks to serve as a foundation for more comprehensive assessments and resilience planning activities. This report is a summary of the efforts at Cape Cod National Seashore (CACO), which outlines the methodology used and the results of the analysis, with the intention of serving as a case study for other parks interested in replicating the process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hurricane Helene: Energy Systems Impact and Situational Insights in East Tennessee

This situational report focuses specifically on energy system performance and interdependencies associated with Hurricane Helene’s impacts across East Tennessee. It does not attempt to identify root causes, evaluate broader emergency response structures, or assess agency effectiveness. Rather, it aims to illuminate how energy disruptions intersected with other lifeline services, particularly water, transportation, and communications, and identify the infrastructural and logistical conditions that shaped those outcomes. Where possible, this report seeks to highlight both constraints and successful practices that emerged during the event.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗