Search NASA⌕ Search

SEARCH · Search NASA

Results for “analyzed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Neutron Irradiation Induced Changes in Isotopic Abundance of 6Li and 3D Nanoscale Distribution of Tritium in LiAlO2 Pellets Analyzed by Atom Probe Tomography

Tritium, a radioactive isotope of hydrogen is produced by neutron irradiation of 6Li enriched LiAlO2 pellets in Tritium producing burnable absorber rods (TPBARs). Three-dimensional nanoscale mapping of Tritium in irradiated pellets is critical to understand its spatial variation and its association with various microstructural features in the pellets. Spatially resolved analysis of 6Li isotopic enrichment in such ceramic pellets before and after irradiation can provide insights to heterogeneities in Li isotopic distribution. However, Li being a light isotope, its spatially resolved compositional or isotopic analysis is a challenging task to most analytical methods. Here we used atom probe tomography, to evaluate the Li isotopic enrichment in both the LiAlO¬2 matrix and the Li deficient secondary phase LiAl5O8 before irradiation. These results were then compared with 6Li isotopic ratio measured by APT analysis of neutron irradiated pellets to clearly demonstrate the unique capability of APT to quantitatively analyze the isotopic enrichment of 6Li as well as for other light elements present in these materials. Evidence for heterogenous nanoscale distribution of 3H and O3H within irradiated pellet microstructure is also provided, which is attributed to 3H trapping in irradiation induced vacancy clusters or voids within the LiAlO2 matrix. The characterization results given here, now prove the feasibility for using APT for analyzing nanoscale spatially resolved isotopic enrichment of Li as well as other light elements such as Tritium in TPBARs. This work also paves way to adopt APT for analyzing light elements such as Li and tritium in materials used for nuclear fusion reactor applications, geochemistry, astrophysics as well as for energy storage applications.

Devaraj, Arun↗

Sapphire analyzers for high-resolution x-ray spectroscopy.

We present a sapphire (Al{sub 2}O{sub 3}) analyzer for high-resolution X-ray spectroscopy with 31-meV energy resolution. The analyzer is designed for resonant inelastic X-ray scattering (RIXS) measurements at the CuK{sub a} absorption edge near 8990 eV. The performance of the analyzer is demonstrated by measuring phonon excitations in beryllium because of its known dynamical structure and high counting rates.

43 PARTICLE ACCELERATORS↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

Time-of-flight analyzer system to detect reflected particles from a solid surface following low-energy particle injection

We have developed a time-of-flight analyzer to measure energy distributions of reflected particles from solid surfaces bombarded by low-energy (1-2 keV) ions. The analyzer yields energy distributions of neutrals which can be compared with the energy distributions of charged particles measured by a magnetic deflection-type momentum analyzer. We have tested the system to measure the angular dependence of energy and intensity for neutrals reflected from a polycrystalline W target. The energies of the reflected neutrals are much smaller than the incident ion energies, suggesting multiple scattering in the target. No angular dependence is observed under the condition that the sum of the incident and reflected angles is constant. The intensity of the reflected neutrals takes the maximum around the mirror angle. We compare these characteristics of neutral particle reflections with those of reflected ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high repetition rate time-of-flight electron energy analyzer

We demonstrate a time-of-flight electron energy analyzer that operates at an 80 MHz repetition rate. The analyzer yields an energy resolution of 40 meV for 3 eV electrons. The energy resolution limit is dominated by the detector time (or temporal) resolution. With a currently available detector with a temporal resolution of 100 ps, we predict an energy resolution of less than 1 meV for 200 meV electrons. This makes high repetition rate time-of-flight energy analyzers a promising low-technology alternative to current state-of-the-art techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals

An analyzer-based x-ray phase-contrast microscopy (ABM) setup combining a standard analyzer-based x-ray phase-contrast imaging (ABI) setup [nondispersive 4-crystal setup (Bonse-Hart setup)] and diffraction by asymmetrically cut crystals is presented here. An attenuation-contrast microscopy setup with conventional x-ray source and asymmetrically cut crystals is first analyzed. Edge-enhanced effects attributed to phase jumps or refraction/total external reflection on the fiber borders were detected. However, the long exposure times and the possibility to achieve high contrast microscopies by using extremely low attenuation-contrast samples motivated us to assemble the ABM setup using a synchrotron source. This setup was found to be useful for low contrast attenuation samples due to the low exposure time, high contrast, and spatial resolution found. Moreover, thanks to the combination with the nondispersive ABI setup, the diffraction-enhanced x-ray imaging algorithm could be applied.

36 MATERIALS SCIENCE↗

Modified Miniature Thomson-Type Analyzer For Measurements Of Mass- and Energy-Spectra Of Ions Within Plasma Facilities

The paper describes important improvements in the construction and operation of a miniature mass- and energy-analyzer of the Thomson type, which was developed especially for measurements of ions inside vacuum experimental chambers. The described analyzer constitutes a modified and improved version of the prototype miniature mass-spectrometer, which was designed several years ago. The paper describes experimental tests of the modified analyzer, which were carried out in the RPI-IBIS facility equipped with a multi-rod plasma injector. Results of the detailed measurements of energy distributions of protons and deuterons (from deuterium discharges) within the energy range from about 20 keV to about 300 keV are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test-bench calibration of the Double-Slit Ion Energy Analyzer for Heavy Ion Beam Probing Diagnostics

This work presents the results of the design study, investigations of the features and a calibration of double-slit ion energy analyzer prototype at the test-bench in IPP NSC KIPT, Kharkov, Ukraine, with beam energy up to 10 keV. Hitherto obtained accuracy for both analyzer slits is {delta}G-2x10{sup -3} and {delta}F-3x10{sup -3}, which is limited by the existing step motor accuracy 0.1 mm for entrance slits moving. The presented study work is considered as the first step to the multi-slit analyzer elaboration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of acceptance angle in measurements with ion energy analyzers: Study by numerical simulations

The importance of an acceptance angle in the plasma diagnostics with ion energy analyzers is investigated by means of numerical simulations. It is shown that wide acceptance angles result in low energy tails in measured ion distribution functions (IDF{sub x}). For flowing plasmas or plasmas with beams, the orientation of the analyzer's orifice gives different results due to bending of ion trajectories in the vicinity of the analyzer. It is demonstrated that the maximum in the IDF{sub x} is at energies lower than the plasma potential. Simulations are done with DIP3D, a three-dimensional particle-in-cell code.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: The intermodulation lockin analyzer

Nonlinear systems can be probed by driving them with two or more pure tones while measuring the intermodulation products of the drive tones in the response. We describe a digital lockin analyzer which is designed explicitly for this purpose. The analyzer is implemented on a field-programmable gate array, providing speed in analysis, real-time feedback, and stability in operation. The use of the analyzer is demonstrated for intermodulation atomic force microscopy. A generalization of the intermodulation spectral technique to arbitrary drive waveforms is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on a logarithmically bent Laue crystal analyzer for X-ray monochromatic backlight imaging

A new logarithmically bent Laue imaging crystal analyzer (LBLICA) was proposed to obtain the monochromatic image of plasmas and exhibited a great potential for application in the Inertial Confinement Fusion experiment over a large field of view (FOV) and with a high spatial resolution. The imaging geometry of the LBLICA has been discussed. According to the Bragg condition and the equation of the logarithmic spiral, the key image parameters of the crystal analyzer, including the system magnification, the spatial resolution, and the FOV, have been analyzed theoretically. An experiment has been performed with a Cu target X-ray tube as a backlighter to backlight a mesh grid consisting of 50-μm Cu wires, and the monochromatic image of the grid has been obtained with a spatial resolution of approximately 30 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Portable rare-earth element analyzer using pyroelectric crystal

We report a portable rare-earth element analyzer with a palm-top size chamber including the electron source of a pyroelectric crystal and the sample stage utilizing cathodoluminescence (CL) phenomenon. The portable rare-earth element analyzer utilizing CL phenomenon is the smallest reported so far. The portable rare-earth element analyzer detected the rare-earth elements Dy, Tb, Er, and Sm of ppm order in zircon, which were not detected by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. We also performed an elemental mapping of rare-earth elements by capturing a CL image using CCD camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spatially resolved retarding field energy analyzer design suitable for uniformity analysis across the surface of a semiconductor wafer

A novel retarding field energy analyzer design capable of measuring the spatial uniformity of the ion energy and ion flux across the surface of a semiconductor wafer is presented. The design consists of 13 individual, compact-sized, analyzers, all of which are multiplexed and controlled by a single acquisition unit. The analyzers were tested to have less than 2% variability from unit to unit due to tight manufacturing tolerances. The main sensor assembly consists of a 300 mm disk to mimic a semiconductor wafer and the plasma sampling orifices of each sensor are flush with disk surface. This device is placed directly on top of the rf biased electrode, at the wafer location, in an industrial capacitively coupled plasma reactor without the need for any modification to the electrode structure. The ion energy distribution, average ion energy, and average ion flux were measured at the 13 locations over the surface of the powered electrode to determine the degree of spatial nonuniformity. The ion energy and ion flux are shown to vary by approximately 20% and 5%, respectively, across the surface of the electrode for the range of conditions investigated in this study.

36 MATERIALS SCIENCE↗

Focusing of intense and divergent ion beams in a magnetic mass analyzer

A magnetic mass analyzer is used to determine the beam composition of a vacuum arc ion source. In the analyzer, we used the concentric multi-ring electrodes to focus the intense and divergent ion beams. We describe the principle, design, and the test results of the focusing device. The diameter of the beam profile is less than 20 mm when the accelerating voltage is 30 kV and the focusing voltage is about 2.0 kV. The focusing device has been successfully used in the magnetic mass analyzer to separate Ti{sup +}, Ti{sup 2+}, and Ti{sup 3+}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing a steady-state phenomenon using an ensemble of sequential transient events: A proof of concept on photocurrent of bacteriorhodopsin upon continuous photoexcitation

The proton pump activity of bacteriorhodopsin in aqueous solution upon excitation with modulated continuous light was monitored electrochemically and analyzed by superimposing a series of transient proton translocation events Hᵢ⁺(t). An evolution function f(t)=(he{sup –lt}+k)/(h+k) , including a decay and a stationary offset, was introduced to weight the contribution of the individual transient events evolving with time in the envelope of the steady-state event. The evolution of the total proton concentration can be treated as an ensemble of weighted sequential transient events, H{sub total}⁺(t)=Σ{{sub i=0}sup n}Hᵢ⁺(t)∙f(t), and the temporal profile of the photocurrent is derived by differentiating the proton concentration with respect to time, (table) . The temporal profiles of the bacteriorhodopsin photocurrent in pH range of 6.3–8.1 were analyzed using a well-defined kinetics model and restricted mathematical formulization, and fitted temporal behaviors agreed with the observations. This successful proof-of-concept study on analyzing a steady-state phenomenon using an ensemble of sequential transient events can be generalized to quantify other phenomena upon continuous stimulation, such as estimation of the light-driven ion pump activities of the photosynthetic proteins upon illumination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: A portable Raman analyzer for microfluidic chips based on a dichroic beam splitter for integration of imaging and signal collection light paths

An integrated and portable Raman analyzer featuring an inverted probe fixed on a motor-driving adjustable optical module was designed for the combination of a microfluidic system. It possesses a micro-imaging function. The inverted configuration is advantageous to locate and focus microfluidic channels. Different from commercial micro-imaging Raman spectrometers using manual switchable light path, this analyzer adopts a dichroic beam splitter for both imaging and signal collection light paths, which avoids movable parts and improves the integration and stability of optics. Combined with surface-enhanced Raman scattering technique, this portable Raman micro-analyzer is promising as a powerful tool for microfluidic analytics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the ion temperature and energy distribution in a lithium-plasma interaction test stand with a retarding field energy analyzer

The ThermoElectric-driven Liquid-metal plasma-facing Structures (TELS) experiment at the University of Illinois is a gas-puff driven, theta-pinch plasma source that is used as a test stand for off-normal plasma events incident on materials in the edge and divertor regions of a tokamak. The ion temperatures and resulting energy distributions are crucial for understanding how well a TELS pulse can simulate an extreme event in a larger, magnetic confinement device. A retarding field energy analyzer (RFEA) has been constructed for use with such a transient plasma due to its inexpensive and robust nature. The innovation surrounding the use of a control analyzer in conjunction with an actively sampling analyzer is presented and the conditions of RFEA operation are discussed, with results presented demonstrating successful performance under extreme conditions. Such extreme conditions are defined by heat fluxes on the order of 0.8 GW m -2 and on time scales of nearly 200 μs. Measurements from the RFEA indicate two primary features for a typical TELS discharge, following closely with the pre-ionizing coaxial gun discharge characteristics. For the case using the pre-ionization pulse (PiP) and the theta pinch, the measured ion signal showed an ion temperature of 23.3 ± 6.6 eV for the first peak and 17.6 ± 1.9 eV for the second peak. For the case using only the PiP, the measured signal showed an ion temperature of 7.9 ± 1.1 eV for the first peak and 6.6 ± 0.8 eV for the second peak. These differences illustrate the effectiveness of the theta pinch for imparting energy on the ions. This information also highlights the importance of TELS as being one of the few linear pulsed plasma sources whereby moderately energetic ions will strike targets without the need for sample biasing.

47 OTHER INSTRUMENTATION↗