Search NASA⌕ Search

SEARCH · Search NASA

Results for “beamlines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

EIC Hadron Beamline Vacuum Studies

Ninety percent of the EIC hadron ring vacuum chamber consists of cold-bore sections running through and interconnecting 4.55 K RHIC superconducting (SC) magnets. The EIC operating specification requires shorter bunches and 3x higher intensity beams which are not appropriate for the present RHIC stainless steel cold-bore beam tube. The intensity and emittance of the hadron beams will degrade due to interactions with residual gas or vacuum instabilities arising from the expected resistive-wall (RW) heating, electron clouds, and beam-induced desorption mechanisms. Without strategies to limit RW heating, major cryogenic system modifications are needed to prevent SC magnet quenches. The SC magnet cold-bore beam tubes will be equipped with a high RRR copper-clad stainless steel screen to significantly reduce RW heating and so the effect on the SC magnet cryogenic heat load and temperature. A thin amorphous carbon film applied to the beam-facing copper surface will suppress electron cloud formation. This paper discusses the vacuum requirements imposed by the EIC hadron beams and the plans to achieve the necessary vacuum and thermal stability that ensure acceptable beam quality and lifetime.

43 PARTICLE ACCELERATORS↗

Design update on the transition beamline for the CEBAF Energy Upgrade

For Jefferson Lab’s 22GeV upgrade, two new permanent-magnet Fixed-Field Alternating Gradient (FFA) arcs will be integrated to serve the accelerator’s six highest-energy recirculation passes. Connecting these FFA arcs to the existing linear accelerator (linac) requires a carefully engineered transition section. The current design has two parts where the first part adiabatically matches the beam dispersion and orbit trajectories, while the second part aligns the Twiss parameters (alpha and beta functions) with those at the linac entrance. Given the tight spatial constraints and multiple matching requirements, a genetic algorithm is being explored to optimize the beam optics matching. This paper presents the current progress in developing and optimizing this transition.

Accelerator Physics↗

Start-to-end self-consistent simulation of the UEM beamline

Addressing the preliminary design review report of the ultrafast electron microscope (UEM), start-to-end self-consistent simulations were carried out to explore fundamental aspects affecting the resolution (space-charge effects, energy spread, shot-to-shot energy jitter, contrast formation, etc.). The electron beam energy spread in the single-shot mode and the effective energy spread in the accumulation mode, equivalent to the convolution of the single-shot energy spread and shot-to-shot energy jitter, have been identified as the ultimate limits of the instrument resolution. A full self-consistent simulation from the photocathode to the detector is being performed using the GPT code to find out what resolution can be achieved. Preliminary results of the start-to-end simulations are reported in this note and the plan of further simulations is presented.

43 PARTICLE ACCELERATORS↗

PARMELA simulation of Line-A beamline

This is a short re-work of the previously accomplished simulations, using PARMELA code package. This exercise was done primarily for increase of fidelity and re-formulating the given task for a different beam dynamics (BD) code. The performed simulations showed very good agreement with the abovementioned simulations and confirm the previously produced results with the BEAMPATH code.

43 PARTICLE ACCELERATORS↗

Alternative Source Verification for the NB5 Beamline

This report details the calculation and comparison of secondary neutron sources for the purpose of performing NB5 velocity selector shielding calculations without relying on the primary HB4 source and the use of a modified MCNP code to run the full model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for a Sterile Neutrino in a 3+1 Framework using Wire-Cell Inclusive Charged-Current $\nu_e$ Selection with the BNB and NuMI beamlines in MicroBooNE

A search for a sterile neutrino is being carried out in the MicroBooNE experiment within the 3+1 (three flavors of active neutrinos + one flavor of sterile neutrino) framework using neutrinos from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI). The sensitivity of this search is built upon high performance inclusive charged-current electron neutrino and muon neutrino event selections. The previous 3+1 sterile neutrino search using only BNB data, the cancellation between $\nu_{e}$ disappearance and $\nu_{e}$ appearance oscillations led to a reduced oscillation effect in the $\nu_{e}$ energy spectrum resulting in a degeneracy of the oscillation parameters. Such a degeneracy is shown to be mitigated by including the neutrino events from the NuMI beam. In this note, the prospect of a 3+1 oscillation analysis using both BNB and NuMI is reported, considerably improving the sensitivity to 3+1 neutrino oscillations.

43 PARTICLE ACCELERATORS↗

Secondary Beamline Lattice Design at the MeV Test Area (MTA)

The MTA is currently configured to produce a secondary pion beam from a tungsten target, which subsequently generates muons from decay in flight. In its present lattice configuration, the currently installed air core quadrupoles are strength-limited in their ability to deliver a high muon flux to the end user. Recently, seven strong iron-core quadrupole spares from the 400-MeV Linac were acquired. Based on these quadrupoles, a new lattice has been designed that maximizes both pion transport and muon capture the line based on significantly shorter magnetic lengths, strong magnetic gradients, and consequently an enhanced angular acceptance. For this project, we demonstrated that the ratio of muons to pions increased by over an order of magnitude (approximately 75 for lattice configurations were studied), successfully capturing a phase space area as large as 13.2 [mm] x 24 [mRad] in simulation.

Winter, Wesley↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗