Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Directed Research in Bone Discipline: Refining Previous Research Observations for Space Medicine

Dual-energy X-ray absorptiometry bone mass density, as a sole index, is an insufficient surrogate for fracture; Clinical Practice Guidelines using bone mass density (both World Health Organization and FRAX) are not specific for complicated subjects such as young, healthy persons following prolonged exposure to skeletal unloading (i.e. an attribute of spaceflight); Research data suggest that spaceflight induces changes to astronaut bones that could be profound, possibly irreversible and unlike age-related bone loss on Earth.; There is a need to objectively assess factors across human physiology that are also influenced by spaceflight (e.g., muscle) that contribute to fracture risk. Some of these objective assessments may require innovative technologies, analyses and modeling.; Astronauts are also exposed to novel situations that may overload their bones highlighting a need integrate biomechanics of physical activities into risk assessments.; As we accumulate data, which reflects the biomechanical competence of bone under specific mechanically-loaded scenarios (even activities of daily living), BONE expects Bone Fracture Module to be more sensitive and/or have less uncertainty in its assessments of fracture probability.; Fracture probability drives the requirement for countermeasures. Level of evidence will unlikely be obtained; hence, the Bone Research and Clinical Advisory Panel (like a Data Safety Monitoring Board) will provide the recommendations.

Sibonga, Jean D.↗

Numerical Modeling of Ocular Dysfunction in Space

Upon introduction to microgravity, the near-loss of hydrostatic pressure causes a marked cephalic (headward) shift of fluid in an astronaut's body. The fluid shift, along with other factors of spaceflight, induces a cascade of interdependent physiological responses which occur at varying time scales. Long-duration missions carry an increased risk for the development of the Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath, kinking of the optic nerve and potentially permanent degradation of visual function. In the cases of VIIP found to date, the initial onset of symptoms occurred after several weeks to several months of spaceflight, by which time the gross bodily fluid distribution is well established. We are developing a suite of numerical models to simulate the effects of fluid shift on the cardiovascular, central nervous and ocular systems. These models calculate the modified mean volumes, flow rates and pressures that are characteristic of the altered quasi-homeostatic state in microgravity, including intracranial and intraocular pressures. The results of the lumped models provide initial and boundary data to a 3D finite element biomechanics simulation of the globe, optic nerve head and retrobulbar subarachnoid space. The integrated set of models will be used to investigate the evolution of the biomechanical stress state in the ocular tissues due to long-term exposure to microgravity.

intraocular pressure↗

Analysis of Human-Spacesuit Interaction

Astronauts sustain injuries of various natures such as finger delamination, joint pain, and redness due to their interaction with the space suit. The role of the Anthropometry and Biomechanics Facility is to understand the biomechanics, environmental variables, and ergonomics of the suit. This knowledge is then used to make suggestions for improvement in future iterations of the space suit assembly to prevent injuries while allowing astronauts maneuverability, comfort, and tactility. The projects I was involved in were the Extravehicular Mobility Unit (EMU) space suit stiffness study and the glove feasibility study. The EMU project looked at the forces exerted on the shoulder, arm, and wrist when subjects performed kinematic tasks with and without a pressurized suit. The glove study consisted of testing three conditions - the Series 4000 glove, the Phase VI glove, and the no glove condition. With more than forty channels of sensor data total, it was critical to develop programs that could analyze data with basic descriptive statistics and generate relevant graphs to help understand what happens within the space suit and glove. In my project I created a Graphical User Interface (GUI) in MATLAB that would help me visualize what each sensor was doing within a task. The GUI is capable of displaying overlain plots and can be synchronized with video. This was helpful during the stiffness testing to visualize how the forces on the arm acted while the subject performed tasks such as shoulder adduction/abduction and bicep curls. The main project of focus, however, was the glove comparison study. I wrote MATLAB programs which generated movies of the strain vectors during specific tasks. I also generated graphs that summarized the differences between each glove for the strain, shear and FSR sensors. Preliminary results indicate that the Phase VI glove places less strain and shear on the hand. Future work includes continued data analysis of surveys and sensor data. In the end, the ideal glove is one that provides more tactility for the astronauts but lessens injuries. Often times, a more tactile glove transmits forces better to the hand; thus, achieving a balance of both a tactile and safe glove is the main challenge present.

Thomas, Neha↗

Sensitivity Analysis of the Bone Fracture Risk Model

Introduction: The probability of bone fracture during and after spaceflight is quantified to aid in mission planning, to determine required astronaut fitness standards and training requirements and to inform countermeasure research and design. Probability is quantified with a probabilistic modeling approach where distributions of model parameter values, instead of single deterministic values, capture the parameter variability within the astronaut population and fracture predictions are probability distributions with a mean value and an associated uncertainty. Because of this uncertainty, the model in its current state cannot discern an effect of countermeasures on fracture probability, for example between use and non-use of bisphosphonates or between spaceflight exercise performed with the Advanced Resistive Exercise Device (ARED) or on devices prior to installation of ARED on the International Space Station. This is thought to be due to the inability to measure key contributors to bone strength, for example, geometry and volumetric distributions of bone mass, with areal bone mineral density (BMD) measurement techniques. To further the applicability of model, we performed a parameter sensitivity study aimed at identifying those parameter uncertainties that most effect the model forecasts in order to determine what areas of the model needed enhancements for reducing uncertainty. Methods: The bone fracture risk model (BFxRM), originally published in (Nelson et al) is a probabilistic model that can assess the risk of astronaut bone fracture. This is accomplished by utilizing biomechanical models to assess the applied loads; utilizing models of spaceflight BMD loss in at-risk skeletal locations; quantifying bone strength through a relationship between areal BMD and bone failure load; and relating fracture risk index (FRI), the ratio of applied load to bone strength, to fracture probability. There are many factors associated with these calculations including environmental factors, factors associated with the fall event, mass and anthropometric values of the astronaut, BMD characteristics, characteristics of the relationship between BMD and bone strength and bone fracture characteristics. The uncertainty in these factors is captured through the use of parameter distributions and the fracture predictions are probability distributions with a mean value and an associated uncertainty. To determine parameter sensitivity, a correlation coefficient is found between the sample set of each model parameter and the calculated fracture probabilities. Each parameters contribution to the variance is found by squaring the correlation coefficients, dividing by the sum of the squared correlation coefficients, and multiplying by 100. Results: Sensitivity analyses of BFxRM simulations of preflight, 0 days post-flight and 365 days post-flight falls onto the hip revealed a subset of the twelve factors within the model which cause the most variation in the fracture predictions. These factors include the spring constant used in the hip biomechanical model, the midpoint FRI parameter within the equation used to convert FRI to fracture probability and preflight BMD values. Future work: Plans are underway to update the BFxRM by incorporating bone strength information from finite element models (FEM) into the bone strength portion of the BFxRM. Also, FEM bone strength information along with fracture outcome data will be incorporated into the FRI to fracture probability.

mathematical models↗

MPCV Exercise Operational Volume Analysis

In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been identified by determining which markers from the motion capture exceed the operational volume and by how much. A credibility assessment of this analysis was performed in accordance with NASA-STD-7009 prior to delivery to the MPCV program.

mathematical models↗

Computational Modeling of Space Physiology for Informing Spaceflight Countermeasure Design and Predictions of Efficacy

MOTIVATION: Spaceflight countermeasures mitigate the harmful effects of the space environment on astronaut health and performance. Exercise has historically been used as a countermeasure to physical deconditioning, and additional countermeasures including lower body negative pressure, blood flow occlusion and artificial gravity are being researched as countermeasures to spaceflight-induced fluid shifts. The NASA Digital Astronaut Project uses computational models of physiological systems to inform countermeasure design and to predict countermeasure efficacy.OVERVIEW: Computational modeling supports the development of the exercise devices that will be flown on NASAs new exploration crew vehicles. Biomechanical modeling is used to inform design requirements to ensure that exercises can be properly performed within the volume allocated for exercise and to determine whether the limited mass, volume and power requirements of the devices will affect biomechanical outcomes. Models of muscle atrophy and bone remodeling can predict device efficacy for protecting musculoskeletal health during long-duration missions. A lumped-parameter whole-body model of the fluids within the body, which includes the blood within the cardiovascular system, the cerebral spinal fluid, interstitial fluid and lymphatic system fluid, estimates compartmental changes in pressure and volume due to gravitational changes. These models simulate fluid shift countermeasure effects and predict the associated changes in tissue strain in areas of physiological interest to aid in predicting countermeasure effectiveness. SIGNIFICANCE: Development and testing of spaceflight countermeasure prototypes are resource-intensive efforts. Computational modeling can supplement this process by performing simulations that reduce the amount of necessary experimental testing. Outcomes of the simulations are often important for the definition of design requirements and the identification of factors essential in ensuring countermeasure efficacy.

biomedical data↗

Systems, devices, and methods for contact measurement and modulation of material properties

Materials and devices are provided for the sensing and manipulation of biomechanical and physiochemical properties of tissues or tissue surfaces. Examples of use include soft tissues such as skin or adipose tissues or more dense tissues such as muscle or heart or dense tissues such as bone. The materials and devices provide for in vivo measurements of biomechanical properties at the tissue surface, e.g. near surface regions of the epidermis or dermis or underlying structures. The devices can be non-invasive and/or non-destructive to the material and, especially for the biomaterials, can be biocompatible and/or biodegradable. The materials and devices can use ultrathin, stretchable networks of mechanical actuators and sensors constructed with nanoribbons of piezoelectric materials.

Dagdeviren, Canan↗

Trunk muscle forces and spinal loads while walking in persons with lower limb amputation: Influences of chronic low back pain

Persons with lower limb amputation (LLA) are at high risk for developing chronic low back pain (LBP), often with biomechanical factors considered as likely contributors. Here, trunk and pelvis kinematics, muscle forces, and resultant spinal loads were characterized in persons with LLA, with and without chronic LBP. Thirty-five persons with unilateral LLA – 19 with chronic LBP (“LLA-cLBP”), 16 without LBP (“LLA-nLBP”) – and 15 (uninjured) persons without LBP (“CTR-nLBP”) walked overground (1.3 m/s) while thorax and pelvis kinematics were tracked (and ranges of motion [ROM] computed), and used as inputs for a non-linear finite element model of the spine to estimate global and local muscle forces, and resultant spinal loads. In the frontal and transverse planes, thorax ROM were up to 66.6% smaller in LLA-nLBP versus LLA-cLBP (P < 0.001) and CTR-nLBP (P < 0.001). In the sagittal plane, pelvis ROM was 50.4% smaller in LLA-nLBP versus LLA-cLBP (P = 0.014). LLA-cLBP exhibited 45.5% and 34.2% greater peak local and global muscle forces, respectively, versus CTR-nLBP (P < 0.011). Up to 48.1% greater spinal loads were observed in LLA-cLBP versus CTR-nLBP (P < 0.013); peak compression and local muscle forces were respectively 20.2% and 41.0% larger in LLA-nLBP versus CTR-nLBP (P < 0.005). Despite differences in trunk and pelvis kinematics between LLA-cLBP and LLA-nLBP, trunk muscle forces and spinal loads were similar (P > 0.101) between these groups. Similar loading parameters regardless of LBP presence, while highly dependent on trunk muscle activation strategies, may mitigate further accumulation of mechanical fatigue. Finally, it remains important to understand the temporality of loading with respect to LBP onset following LLA.

60 APPLIED LIFE SCIENCES↗

Sneezing and asymptomatic virus transmission

The novel coronavirus disease (COVID-19) spread pattern continues to show that geographical barriers alone cannot contain a virus. Asymptomatic carriers play a critical role in the nature of this virus quickly escalating into a global pandemic. Asymptomatic carriers may transmit the virus unintentionally through sporadic sneezing. A novel Computational Fluid Dynamics (CFD) approach has been proposed with a realistic modeling of a human sneeze achieved by the combination of state-of-the-art experimental and numerical methods. This modeling approach may be suitable for future engineering analyses aimed at reshaping public spaces and common areas, with the main objective to accurately predict the spread of aerosol and droplets that may contain pathogens. This study shows that the biomechanics of a human sneeze, including complex muscle contractions and relaxations, can be accurately modeled by the angular head motion and the dynamic pressure response during sneezing. These have been considered as the human factors and were implemented in the CFD simulation by imposing a momentum source term to the coupled Eulerian–Lagrangian momentum equations. The momentum source was modeled by the measured dynamic pressure response in conjunction with the angular head motion. This approach eliminated the need to create an ad hoc set of inlet boundary conditions. With this proposed technique, it is easier to add multiple fixed and/or moving sources of sneezes in complex computational domains. Additionally, extensive sensitivity analyses based on different environmental conditions were performed, and their impact was described in terms of potential virus spread.

42 ENGINEERING↗

Let it rip: The mechanics of self-bisection in asexual planarians determines their population reproductive strategies

Asexual freshwater planarians reproduce by transverse bisection (binary fission) into two pieces. This process produces a head and a tail, which fully regenerate within 1-2 weeks. How planarians split into two offspring - using only their musculature and substrate traction – is a challenging biomechanics problem. We found that three different species, Dugesia japonica, Girardia tigrina and Schmidtea mediterranea, have evolved three different mechanical solutions to self-bisect. Using time lapse imaging of the fission process, we quantitatively characterize the main steps of division in the three species and extract the distinct and shared key features. Across the three species, planarians actively alter their body shape, regulate substrate traction, and use their muscles to generate tensile stresses large enough to overcome the ultimate tensile strength of the tissue. Moreover, we show that how each planarian species divides dictates how resources are split among its offspring. This ultimately determines offspring survival and reproductive success. Furthermore, heterospecific differences in the mechanics of self-bisection of individual worms explain the observed differences in the population reproductive strategies of different planarian species.

59 BASIC BIOLOGICAL SCIENCES↗

Reconsidering tympanal-acoustic interactions leads to an improved model of auditory acuity in a parasitoid fly

Although most binaural organisms locate sound sources using neurological structures to amplify the sounds they hear, some animals use mechanically coupled hearing organs instead. One of these animals, the parasitoid fly Ormia ochracea (O. ochracea), has astoundingly accurate sound localization abilities. It can locate objects in the azimuthal plane with a precision of 2°, equal to that of humans, despite an intertympanal distance of only 0.5 mm, which is less than 1/100th of the wavelength of the sound emitted by the crickets that it parasitizes. O. ochracea accomplishes this feat via mechanically coupled tympana that interact with incoming acoustic pressure waves to amplify differences in the signals received at the two ears. In 1995, Miles et al developed a model of hearing mechanics in O. ochracea that represents the tympana as flat, front-facing prosternal membranes, though they lie on a convex surface at an angle from the flies' frontal and transverse planes. The model works well for incoming sound angles less than ±30° but suffers from reduced accuracy (up to 60% error) at higher angles compared to response data acquired from O. ochracea specimens. Despite this limitation, it has been the basis for bio-inspired microphone designs for decades. Here, we present critical improvements to this classic hearing model based on information from three-dimensional reconstructions of O. ochracea's tympanal organ. We identified the orientation of the tympana with respect to a frontal plane and the azimuthal angle segment between the tympana as morphological features essential to the flies' auditory acuity, and hypothesized a differentiated mechanical response to incoming sound on the ipsi- and contralateral sides that depend on these features. We incorporated spatially-varying model coefficients representing this asymmetric response, making a new quasi-two-dimensional (q2D) model. The q2D model has high accuracy (average errors of under 10%) for all incoming sound angles. This improved biomechanical model may inform the design of new microscale directional microphones and other small-scale acoustic sensor systems.

36 MATERIALS SCIENCE↗

Pectin methylesterase selectively softens the onion epidermal wall yet reduces acid-induced creep

De-esterification of homogalacturonan (HG) is thought to stiffen pectin gels and primary cell walls by increasing calcium cross-linking between HG chains. Contrary to this idea, recent studies found that HG de-esterification correlated with reduced stiffness of living tissues, measured by surface indentation. The physical basis of such apparent wall softening is unclear, but possibly involves complex biological responses to HG modification. To assess the direct physical consequences of HG de-esterification on wall mechanics without such complications, we treated isolated onion (Allium cepa) epidermal walls with pectin methylesterase (PME) and assessed wall biomechanics with indentation and tensile tests. In nanoindentation assays, PME action softened the wall (reduced the indentation modulus). In tensile force/extension assays, PME increased plasticity, but not elasticity. These softening effects are attributed, at least in part, to increased electrostatic repulsion and swelling of the wall after PME treatment. Despite softening and swelling upon HG de-esterification, PME treatment alone failed to induce cell wall creep. Instead, acid-induced creep, mediated by endogenous α-expansin, was reduced. We conclude that HG de-esterification physically softens the onion wall, yet reduces expansin-mediated wall extensibility.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic and kinematic strategies for head movement control

This paper describes our analysis of the complex head-neck system using a combination of experimental and modeling approaches. Dynamical analysis of head movements and EMG activation elicited by perturbation of trunk position has examined functional contributions of biomechanically and neurally generated forces in lumped systems with greatly simplified kinematics. This has revealed that visual and voluntary control of neck muscles and the dynamic and static vestibulocollic and cervicocollic reflexes preferentially govern head-neck system state in different frequency domains. It also documents redundant control, which allows the system to compensate for lesions and creates a potential for substantial variability within and between subjects. Kinematic studies have indicated the existence of reciprocal and co-contraction strategies for voluntary force generation, of a vestibulocollic strategy for stabilizing the head during body perturbations and of at least two strategies for voluntary head tracking. Each strategy appears to be executed by a specific muscle synergy that is presumably optimized to efficiently meet the demands of the task.

Non-NASA Center↗

[Cytoembryologic studies of super dwarf wheat grown in "Svet" greenhouse in the ground-based experiments]

The Project of scientific programs MIR/SHUTTLE and MIR/NASA was allowed for studying the productional, cytoembryological, morphological, biomechanical and other characteristics of superclub wheat on cultivation in the Svet greenhouse on-board orbital complex. This work was aimed at studying the duration of the complete cycle of ontogenesis of wheat and its individual stages, the peculiarities of forming the reproductive organs, processes, fertilization and formation of the seed production while cultivating in the Svet greenhouse under terrestrial conditions. Superclub wheat has been the object of experimentation. On cultivation of superclub wheat in the Svet greenhouse at designated conditions it was found that the cycle duration "from seed to seed" was 90-97 days. The number of granules in the wheat-ears studied was quite low and ranged from 15 to 30%. Performed studies with applying the light microscopy have indicated that in superclub wheat the embryological processes occur in compliance with those regularities which are described for the other forms of soft wheat.

Non-NASA Center↗

Running in the real world: adjusting leg stiffness for different surfaces

A running animal coordinates the actions of many muscles, tendons, and ligaments in its leg so that the overall leg behaves like a single mechanical spring during ground contact. Experimental observations have revealed that an animal's leg stiffness is independent of both speed and gravity level, suggesting that it is dictated by inherent musculoskeletal properties. However, if leg stiffness was invariant, the biomechanics of running (e.g. peak ground reaction force and ground contact time) would change when an animal encountered different surfaces in the natural world. We found that human runners adjust their leg stiffness to accommodate changes in surface stiffness, allowing them to maintain similar running mechanics on different surfaces. These results provide important insight into mechanics and control of animal locomotion and suggest that incorporating an adjustable leg stiffness in the design of hopping and running robots is important if they are to match the agility and speed of animals on varied terrain.

NASA Discipline Musculoskeletal↗

Effect of a hypergravity environment on cortical bone elasticity in rats

There is considerable interest in determining whether hypergravity can be used as a countermeasure for microgravity-induced bone loss. This study was conducted on 20 immature male rats in order to investigate possible elastic adaptations of cortical bone in rapidly growing rats exposed to chronic hypergravity. Ten rats were continuously centrifuged for 14 days at twice gravitational acceleration (2G) on a 12.75 foot radius centrifuge and 10 rats concurrently acted as stationary controls. The effect of hypergravity on the elastic characteristics of cortical bone was quantified via ultrasonic wave propagation. Propagation velocities of longitudinal and shear waves were measured through cubic cortical specimens from the posterior femoral diaphyses. Density was measured with an Archimedes' technique. The orthotropic elastic properties were calculated and used to compare the difference between groups. Results showed an average increase in both the Young's moduli (Eii, + 2.2%) and shear moduli (Gij, + 4.3%) with a statistically significant increase only in G12 (+15.7%, P = 0.046). The ratio of transverse to axial strain (Poisson's ratio, nuij) demonstrated statistically significant changes in nu12, nu21, nu13, and nu31 (P < 0.05). These findings suggest that although slight elastic changes were incurred via a hypergravity environment, the treatment level or duration in this study do not dramatically perturb the normal elastic behavior of cortical bone and that dramatic biomechanical differences noted in previous studies were due more to structural changes than material elasticity changes. Hypergravity applied post facto to a microgravity environment would offer further illucidation of this method as treatment for a degenerative spaceflight experience.

Non-NASA Center↗