Search NASA⌕ Search

SEARCH · Search NASA

Results for “conduction cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SRF E - Beam Accelerator for Metal Additive Manufacturing [Patent]

A system and apparatus for electron beam melting comprises a superconducting radio frequency accelerator configured to produce an electron beam, a conduction cooling system configured to cool the superconducting radio frequency accelerator, and an electron beam melting system wherein the electron beam melts power in a build chamber of the electron beam melting apparatus.

43 PARTICLE ACCELERATORS↗

Deployable Cryocooler Based Cryomodule

Superconducting Radio Frequency (SRF) linear accelerators (linacs) have shown tremendous promise in extending the intensity frontier of particle accelerator technology. However, they are large and complex systems, requiring a central refrigeration system and complex piping to distribute liquid helium and nitrogen to the accelerating cavities. In response to these problems, RadiaBeam Technologies, LLC. proposes to develop a small mobile cryomodule that can be safely deployed to its planned field location. The scope of this work is to provide RadiaBeam with the specifications for a complete 650 MHz RF cavity model that can be incorporated into a compact SRF accelerator. Fermilab’s contribution will involve sharing contact resistance measurements, design parameters, and solid models. Design parameters will include the cavity frequency and gradient, length of the linac, number of cryocoolers, etc. This will ensure that the design is useful for practical linacs. A complete cryomodule design is envisioned. Radiabeam will design the cryomodule based on input from Fermilab’s experience on conduction cooling and the needs for a compact SRF accelerator.

43 PARTICLE ACCELERATORS↗

First Results from A $Nb_3Sn$-Coated 1.5-Cell 650MHZ SRF Cavity for Cryogen-Free Industrial Accelerators

Fermilab is advancing the development of a compact, high-power electron beam accelerator using superconducting radio frequency (SRF) technology as a non-radioactive alternative to traditional radiological sources. The current design targets continuous-wave (CW) operation at \SI{1.6}{MeV} and \SI{20}{kW}. To ensure suitability for industrial environments, the system is being designed for cryogen-free operation, driving the adoption of a novel Nb$_3$Sn-coated 1.5-cell SRF cavity operating at \SI{650}{MHz}. This contribution reports on the fabrication, surface preparation, and Nb$_3$Sn coating process of the cavity, as well as first results from vertical test stand (VTS) measurements performed in a liquid helium bath. These initial tests mark a key milestone toward demonstrating the viability of conduction-cooled Nb$_3$Sn SRF cavities for industrial-scale deployment.

Tagdulang, Nikki Diala [Fermilab]↗

Design of a shipping fixture for a compact cryomodule hermetic assembly

Two conduction-cooled 915 MHz superconducting radio frequency hermetic assemblies must be safely transported from the Jefferson Lab in Newport News, VA to General Atomics in San Diego, CA for perfor-mance testing in a custom horizontal test cryostat. One hermetic assembly consists of a 2-cell 915 MHz cavity, a coaxial fundamental power coupler, and the warm-to-cold transition beam tubes. The second hermetic assembly consists of a 2-cell 915 MHz cavity only. The assemblies will be transported on a flatbed air-ride trailer over the approximate 4000 km distance. Design requirements included adequate attenuation of 4g vertical axis, 5g beamline axis, and 1.5g lateral axis shock events. The isolation system was designed using helical wire-rope isolators with modal and transient finite element analysis performed in Ansys. Results show shock attenuation of a 10 ms half-sine pulse input to < 1g in the vertical axis, < 1.5g in the beam-line axis, and < 0.5g in the lateral axis for both assem-blies at the specified design loads and all structural stresses are kept below the material yield limits. Addi-tionally, the natural frequencies of both isolation sys-tems adequately attenuate the fundamental modes of the critical structures.

Accelerator Physics↗

Microstructure of Neutron-Irradiated Al 3 Hf-Al Thermal Neutron Absorber Materials

A thermal neutron-absorbing metal matrix composite (MMC) comprised of Al 3 Hf particles in an aluminum matrix was developed to filter out thermal neutrons and create a fast flux environment for material testing in a mixed-spectrum nuclear reactor. Intermetallic Al 3 Hf particles capture thermal neutrons and are embedded in a highly conductive aluminum matrix that provides conductive cooling of the heat generated due to thermal neutron capture by the hafnium. These Al 3 Hf-Al MMCs were fabricated using powder metallurgy via hot pressing. The specimens were neutron-irradiated to between 1.12 and 5.38 dpa and temperatures ranging from 286 °C to 400 °C. The post-irradiation examination included microstructure characterization using transmission electron microscopy (TEM) and energy-dispersive X-ray spectroscopy. This study reports the microstructural observations of four irradiated samples and one unirradiated control sample. All the samples showed the presence of oxide at the particle–matrix interface. The irradiated specimens revealed needle-like structures that extended from the surface of the Al 3 Hf particles into the Al matrix. An automated segmentation tool was implemented based on a YOLO11 computer vision-based approach to identify dislocation lines and loops in TEM images of the irradiated Al-Al 3 Hf MMCs. This work provides insight into the microstructural stability of Al 3 Hf-Al MMCs under irradiation, supporting their consideration as a novel neutron absorber that enables advanced spectral tailoring.

36 MATERIALS SCIENCE↗

TEM Characterization of Neutron Irradiated HfAl3-Al Composite Specimens

Particles comprised of a thermal neutron absorbing material (HfAl3) are dispersed in a metal matrix material with high thermal conductivity (aluminum) to conduct the heat generated by neutron capture away from the fuel and materials. This metal matrix composite is very promising for use as a conduction-cooled neutron absorber and has the potential to be useful as a shroud or heat sink for testing advanced fast reactor fuels and materials in an existing thermal reactor. To design and optimize the absorber block system for advanced reactor designs, fundamental understanding of the irradiation effect on material properties is necessary. This dataset contains TEM characterization results of neutron irradiated HfAl3-Al composite specimens. It is focused on the irradiation induced defects (dislocation lines and loops) characterization using the on-zone axis bright field STEM technique. This data was collected using a FEI Tecnai G2 F30 S/TEM at the Microscopy and Characterization Suite (MaCS), Center for Advanced Energy Studies (CAES).

Guillen, Donna↗

TEM Characterization of Neutron Irradiated HfAl3-Al Composite Specimens

Particles comprised of a thermal neutron absorbing material (HfAl3) are dispersed in a metal matrix material with high thermal conductivity (aluminum) to conduct the heat generated by neutron capture away from the fuel and materials. This metal matrix composite is very promising for use as a conduction-cooled neutron absorber and has the potential to be useful as a shroud or heat sink for testing advanced fast reactor fuels and materials in an existing thermal reactor. To design and optimize the absorber block system for advanced reactor designs, fundamental understanding of the irradiation effect on material properties is necessary. This dataset contains TEM characterization results of neutron irradiated HfAl3-Al composite specimens. It is focused on the irradiation induced defects (dislocation lines and loops) characterization using the on-zone axis bright field STEM technique. This data was collected using a FEI Tecnai G2 F30 S/TEM at the Microscopy and Characterization Suite (MaCS), Center for Advanced Energy Studies (CAES).

Guillen, Donna↗

Electrochemical oxygen concentrator as an oxygen compressor

A solid polymer electrolyte (SPE) oxygen compressor is described which generates pressures of 3000 psi. The SPE is a cation exchange membrane with chemical compatibility, and has the capability of withstanding 5000 psi. Other features of the compressor described include: gasketless sealing, porus plate cell supports, and conductive cooling. Results are presented of a computer program which defines the power of the system as a function of density, temperature, pressure, membrane thickness, and water content.

Source record↗

Description of a 2.3 kW power transformer for space applications

The principle features and special testing of a high voltage high power transformer designed and developed for space application are described. The transformer is operated in a series resonant inverter supplying beam power to a 30 cm mercury ion thruster. Electrical requirements include operation of 2.3 kW continuous power output, primary currents to 35 amps rms, and frequencies up to 20 kHz. High efficiency was obtained through detailed considerations of the tradeoffs available in core materials, wire selection, coil configurations and thermal control. A number of novel heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Description of A 2.3 kW power transformer for space applications

The paper describes the principal features and special testing of a high-frequency high-power low-specific-weight (0.57 kg/kW) 2.3-kW electronic power transformer developed for space applications. The transformer is operated in a series resonant inverter supplying beam power to a 30-cm mercury ion thruster. High efficiency (above 98.5%) is obtained through careful detailed design. A number of unique heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Some experience with arc-heater simulation of outer planet entry radiation

An electric arc heater was operated at 800 amperes and 100,000 pa (1 atm) with hydrogen, helium, and two mixtures of hydrogen and helium. A VUV-scanning monochromator was used to record the spectra from an end view while a second spectrometer was used to determine the plasma temperature using hydrogen continuum radiation at 562 nm. Except for pure helium, the plasma temperature was found to be too low to produce significant helium radiation, and the measured spectra were primarily the hydrogen spectra with the highest intensity in the pure hydrogen case. A radiation computer code was used to compute the spectra for comparison to the measurements and to extend the study to simulation of outer planet entry radiation. Conductive cooling prevented ablation of phenolic carbon material samples mounted inside the arc heater during a cursory attempt to produce radiation absorption by ablation gases.

Wells, W. L.↗

An 8 x 10 to the 5th bit bubble memory cell for spacecraft applications

A multiple chip magnetic bubble memory cell design developed for NASA embodies the low power, low weight, environmental tolerance and reliability necessary for successful operation in spacecraft launch and mission environments. Packaging of multiple chips in a common magnetic bias, drive coil assembly reduces weight and volume overhead per chip and also reduces the number of coil drive components required. This 8 x 10 to the 5th bit cell is conduction cooled and provides a metal and ceramic sealed hermetic chip environment.

Becker, F. J.↗

Cryogenic testing of mirrors for infrared space telescopes

The Shuttle IR Telescope Facility (SIRTF) test apparatus can test candidate mirror materials as large as 66 cm in diameter, at temperatures as low as about 10 K, and is accurate enough to detect optical figure changes as small as a fraction of a wavelength from the room temperature figure. The fused silica mirrors currently undergoing testing in the SIRTF are sunk into a liquid He reservoir with copper straps, whose individual strands are soldered to small silver spots diffused throughout the unfigured side of the mirror to accomplish fast conductive cooling. Optical access to the cold mirror is by means of a small glass port in the vacuum chamber. An interferometer is used to examine the mirror figure throughout the cool-down. Interferograms are photographed, fringe patterns are digitized, and mirror figure contour plots are calculated by means of a computer.

Miller, J. H.↗

Superconducting magnet

Extensive computer based engineering design effort resulted in optimization of a superconducting magnet design with an average bulk current density of approximately 12KA/cm(2). Twisted, stranded 0.0045 inch diameter NbTi superconductor in a copper matrix was selected. Winding the coil from this bundle facilitated uniform winding of the small diameter wire. Test coils were wound using a first lot of the wire. The actual packing density was measured from these. Interwinding voltage break down tests on the test coils indicated the need for adjustment of the wire insulation on the lot of wire subsequently ordered for construction of the delivered superconducting magnet. Using the actual packing densities from the test coils, a final magnet design, with the required enhancement and field profile, was generated. All mechanical and thermal design parameters were then also fixed. The superconducting magnet was then fabricated and tested. The first test was made with the magnet immersed in liquid helium at 4.2K. The second test was conducted at 2K in vacuum. In the latter test, the magnet was conduction cooled from the mounting flange end.

Source record↗

Inhibition of conductive heat flow by magnetic constriction in the corona and transition region - Dependence on the shape of the constriction

Attention is given to the process by which the shape of the constriction of field lines inhibiting the conduction of heat down from the corona acts in conjunction with the degree of constriction to inhibit the heat flow. The analytical model for the heat flow involves tapered flux tubes in which the plasma properties are constant on cross sections, while the plasma is static and the only energy transfer is by thermal conduction. It is determined that only two specific solutions to the model are applicable to the solar atmosphere: the steady state, which is appropriate for quiet regions and for active ones that are not flaring, and the time-dependent case, in which no heat enters the hot end, which is appropriate for conductive cooling of flare loops.

Moore, R. L.↗

A reconnection mechanism for coronal condensations in two-ribbon flares

The series of self-consistent, two-dimensional, MHD calculations used to explore the reconnection dynamics implicit in the two-ribbon flare model of Kopp and Pneumann (1976) indicate that there exists, in addition to the standard, slow mode MHD shocks generated by reconnection, a standing, fast mode MHD shock. Due to thermal conduction, the slow shocks generate an evaporative upflow of chromospheric plasma into the reconnection region; an analysis of these effects of radiative and conductive cooling suggests that at least some of this evaporated plasma will undergo thermal condensation in passing through the fast shock.

Forbes, T. G.↗

The 60 GHz solid state power amplifier

A new amplifier architecture was developed during this contract that is superior to any other solid state approach. The amplifier produced 6 watts with 4 percent efficiency over a 2 GHz band at 61.5 GHz. The unit was 7 x 9 x 3 inches in size, 5.5 pounds in weight, and the conduction cooling through the baseplate is suitable for use in space. The amplifier used high efficiency GaAs IMPATT diodes which were mounted in 1-diode circuits, called modules. Eighteen modules were used in the design, and power combining was accomplished with a proprietary passive component called a combiner plate.

Mcclymonds, J.↗

Development of microchannel plates in advanced wind-tunnel instrumentation

Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

Feller, W. Bruce↗