Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Oxygen isotope fractionation in stratospheric CO2

A new cryogenic collection system has been flown on board a balloon gondola to obtain separate samples of ozone and carbon dioxide without entrapping major atmospheric gases. Precision laboratory isotopic analysis of CO2 samples collected between 26 and 35.5 km show a mass-independent enrichment in both O-17 and O-18 of about 11 per mil above tropospheric values. Ozone enrichment in its heavy isotopes was 9 to 16 percent in O3-50 and 8 to 11 percent in O3-49, respectively (Schueler et al., 1990). A mechanism to explain the isotope enrichment in CO2 has been recently proposed by Yung et al. (1991). The model is based on the isotope exchange between CO2 and O3 via O(1D), resulting in a transfer of the ozone isotope enrichment to carbon dioxide. Predicted enrichment and measured values agree well.

Thiemens, M. H.↗

Space-exposure effects on optical-baffle coatings at far-infrared wavelengths

Reflectance of six optical-black coatings was remeasured over the near-infrared to the far-infrared region after nearly six years in space aboard the Long Duration Exposure Facility satellite. Measurements were made at room temperature and at cryogenic temperatures. The most notable effect was a general decrease in reflectance for typical samples at all wavelengths. Analysis indicates that this decrease is caused by an increase in absorption resulting from an increase in the imaginary part of the index of refraction, and not by a change in thickness, or increased surface roughness giving rise to increased scattering. These results suggest that such optical-baffle materials will provide enhanced performance as a result of aging in the space environment.

Blue, M. D.↗

Wavefront Sensing with the Fine Guidance Sensor for James Webb Space Telescope

An analysis is presented that utilizes the Fine Guidance Sensor (FGS) for focal-plane wavefront sensing (WFS) for the James Webb Space Telescope (JWST). WFS with FGS increases the number of wavefront measurements taken in field of the telescope, but has many challenges over the other JWST instruments that make it unique, such as; less sampling of the Point Spread Function (PSF), a smaller diversity-defocus range, a smaller image detector size, and a polychromatic object or source. Additionally, presented is an analysis of sampling for wavefront sensing. Results are shown based on simulations of flight and the cryogenic optical testing at NASA Johnson Space Center.

Smith, J. Scott↗

Wider-Opening Dewar Flasks for Cryogenic Storage

Dewar flasks have been proposed as containers for relatively long-term (25 days) storage of perishable scientific samples or other perishable objects at a temperature of 175 C. The refrigeration would be maintained through slow boiling of liquid nitrogen (LN2). For the purposes of the application for which these containers were proposed, (1) the neck openings of commercial off-the-shelf (COTS) Dewar flasks are too small for most NASA samples; (2) the round shapes of the COTS containers give rise to unacceptably low efficiency of packing in rectangular cargo compartments; and (3) the COTS containers include metal structures that are too thermally conductive, such that they cannot, without exceeding size and weight limits, hold enough LN2 for the required long-term-storage. In comparison with COTS Dewar flasks, the proposed containers would be rectangular, yet would satisfy the long-term storage requirement without exceeding size and weight limits; would have larger neck openings; and would have greater sample volumes, leading to a packing efficiency of about double the sample volume as a fraction of total volume. The proposed containers would be made partly of aerospace- type composite materials and would include vacuum walls, multilayer insulation, and aerogel insulation.

Ruemmele, Warren P.↗

Characterization of Lunar Polar Volatiles for Curation and ISRU - Executive Summary

The goal of this project is to support lunar exploration by simulating and characterizing ice and volatile-rich materials expected to be found at the lunar poles. These materials are highly sensitive to heating, which could significantly alter their composition and prevent scientific studies on lunar samples. During FY19, we obtained materials for and designed a simulated lunar environment, within which volatile-rich simulant could be made. We also refined the procedure for moderate-fidelity lunar simulants at cryogenic temperatures. In FY20, we completed our test setup, and we can now reach cryogenic temperatures and near-lunar pressures with active compositional monitoring of volatiles in the vapor phase. For FY21, we: 1) progressed towards developing sample storage temperature requirements for volatile-rich samples by completing storage testing, along with materials testing for Artemis geologic sampling, 2) obtained instrumentation for solid sample monitoring to characterize solid species, and 3) progressed towards water extraction testing for ISRU. Our test results will directly feed into Artemis science requirements, hardware designs for sample return, vehicle requirements (HLS, Gateway, Orion), and operations planning for lunar exploration activities.

Julie L Mitchell↗

Impact of lunar and planetary missions on the space station

The impacts upon the growth space station of several advanced planetary missions and a populated lunar base are examined. Planetary missions examined include sample returns from Mars, the Comet Kopff, the main belt asteroid Ceres, a Mercury orbiter, and a saturn orbiter with multiple Titan probes. A manned lunar base build-up scenario is defined, encompassing preliminary lunar surveys, ten years of construction, and establishment of a permanent 18 person facility with the capability to produce oxygen propellant. The spacecraft mass departing from the space station, mission Delta V requirements, and scheduled departure date for each payload outbound from low Earth orbit are determined for both the planetary missions and for the lunar base build-up. Large aerobraked orbital transfer vehicles (OTV's) are used. Two 42 metric ton propellant capacity OTV's are required for each the the 68 lunar sorties of the base build-up scenario. The two most difficult planetary missions (Kopff and Ceres) also require two of these OTV's. An expendable lunar lander and ascent stage and a reusable lunar lander which uses lunar produced oxygen are sized to deliver 18 metric tons to the lunar surface. For the lunar base, the Space Station must hangar at least two non-pressurized OTV's, store 100 metric tons of cryogens, and support an average of 14 OTV launch, return, and refurbishment cycles per year. Planetary sample return missions require a dedicated quarantine module.

Source record↗

Instrument for Measuring Cryo CTE

Coefficient of thermal expansion is an integral part of the performance of optical systems, especially for those, which operate at cryogenic temperatures. The measurement of the coefficient of relevant materials has been of continuous interest. Besides commercial measurement sources, development of one-of-a-kind tools have always been of interest due to local needs. This paper describes one such development at the University of Alabama in Huntsville (UAH). The approach involves two vertical rods (one sample and one reference) on a flat platform. A probe bar is held horizontally atop the two samples. A temperature change will generally cause rotation of the probe bar. A mirrored surface on one end of the probe bar is used to measure the rotation using the reflection of an incident laser beam upon it. A position-sensing detector measures the change of the reflected beam spot position. Using other known quantities, the change determines the coefficient of thermal expansion of the sample material as a function of temperature. A parallel measurement of the rotation of the sample support platform is also performed to account for any unwanted background effects. This system has been demonstrated in a cryogenic chamber at the NASA Marshall Space Flight Center X-ray Calibration Facility (XRCF). We present the system details, achievable sensitivity, and up-to-date experimental performance.

Vikram, Chandra S.↗

Results from the Air Force Geophysics Laboratory survey catalog

Results of an IR survey program designed to obtain the spatial and brightness distributions of a representative sample of IR-emitting objects in the 3-30 micron range are analyzed. Small cryogenically cooled telescopes carried above the atmosphere on sounding rockets were employed in the research. Minimization of sky noise and photon background, experimental equipment, and data reduction techniques are discussed.

Price, S. D.↗

Advanced propulsion for the Mars Rover Sample Return Mission

The present evaluation of highly detailed advanced propulsion system design concepts for the Mars Rover Sample Return Mission proceeded by comparing a baseline chemical propulsion option with both storable and cryogenic advanced chemical propulsion alternatives and solar- and nuclear-based electric propulsion OTVs. Substantial launch mass reductions and commensurate payload mass increases were obtainable with both advanced chemical and electric propulsion cycles.

Palaszewski, Bryan↗

In Situ Resource Utilization (ISRU II) Technical Interchange Meeting

This volume contains extended abstracts that have been accepted for presentation at the In Situ Resource Utilization (ISRU II) Technical Interchange Meeting, November 18-19, 1997, at the Lunar and Planetary Institute, Houston, Texas. Included are topics which include: Extraterrestrial resources, in situ propellant production, sampling of planetary surfaces, oxygen production, water vapor extraction from the Martian atmosphere, gas generation, cryogenic refrigeration, and propellant transport and storage.

David Kaplan↗

The JPL Molecular Contamination Investigation Facility

The Molecular Contamination Investigation Facility (MCIF) is discussed in terms of its use for improving the far-UV performance of a camera and its broader applications. The MCIF incorporates two independent vacuum systems with sample isolation chambers and regulated heat exchangers as well as three quartz-crystal microbalances (QCMs) and a residual gas analyzer. One cryogenic QCM is heat sunk into an LN2 heat exchanger, while the others are thermoelectrically controlled and are heat sunk into a regulated heat exchanger. Outgas accumulation can be measured at three surface temperatures between -180 and 80 C simultaneously, and results are presented for the testing of 34 samples in a large-chambered system and 22 samples in a system with a smaller chamber. The MCIF results provide a database for fabrication processes, material selection, maximum bakeout temperatures, and the development of an ultraclean bakeout chamber.

Taylor, Daniel M.↗

Reliable Transport over SpaceWire for James Webb Space Telescope (JWST) Focal Plane Electronics (FPE) Network

NASA's James Webb Space Telescope (JWST) faces difficult technical and budgetary challenges to overcome before it is scheduled launch in 2010. The Integrated Science Instrument Module (ISIM), shares these challenges. The major challenge addressed in this paper is the data network used to collect, process, compresses and store Infrared data. A total of 114 Mbps of raw information must be collected from 19 sources and delivered to the two redundant data processing units across a twenty meter deployed thermally restricted interface. Further data must be transferred to the solid-state recorder and the spacecraft. The JWST detectors are kept at cryogenic temperatures to obtain the sensitivity necessary to measure faint energy sources. The Focal Plane Electronics (FPE) that sample the detector, generate packets from the samples, and transmit these packets to the processing electronics must dissipate little power in order to help keep the detectors at these cold temperatures. Separating the low powered front-end electronics from the higher-powered processing electronics, and using a simple high-speed protocol to transmit the detector data minimize the power dissipation near the detectors. Low Voltage Differential Signaling (LVDS) drivers were considered an obvious choice for physical layer because of their high speed and low power. The mechanical restriction on the number cables across the thermal interface force the Image packets to be concentrated upon two high-speed links. These links connect the many image packet sources, Focal Plane Electronics (FPE), located near the cryogenic detectors to the processing electronics on the spacecraft structure. From 12 to 10,000 seconds of raw data are processed to make up an image, various algorithms integrate the pixel data Loss of commands to configure the detectors as well as the loss of science data itself may cause inefficiency in the use of the telescope that are unacceptable given the high cost of the observatory. This combination of requirements necessitates a redundant, fault tolerant, high- speed, low mass, low power network with a low Bit error Rate(1E-9- 1E-12). The ISIM systems team performed many studies of the various network architectures that meeting these requirements. The architecture selected uses the Spacewire protocol, with the addition of a new transport and network layer added to implement end-to-end reliable transport. The network and reliable transport mechanism must be implemented in hardware because of the high average information rate and the restriction on the ability of the detectors to buffer data due to power and size restrictions. This network and transport mechanism was designed to be compatible with existing Spacewire links and routers so that existing equipment and designs may be leveraged upon. The transport layer specification is being coordinated with European Space Agency (ESA), Spacewire Working Group and the Consultative Committee for Space Data System (CCSDS) PlK Standard Onboard Interface (SOIF) panel, with the intent of developing a standard for reliable transport for Spacewire. Changes to the protocol presented are likely since negotiations are ongoing with these groups. A block of RTL VHDL that implements a multi-port Spacewire router with an external user interface will be developed and integrated with an existing Spacewire Link design. The external user interface will be the local interface that sources and sinks packets onto and off of the network (Figure 3). The external user interface implements the network and transport layer and handles acknowledgements and re-tries of packets for reliable transport over the network. Because the design is written in RTL, it may be ported to any technology but will initially be targeted to the new Actel Accelerator series (AX) part. Each link will run at 160 Mbps and the power will be about 0.165 Watt per link worst case in the Actel AX.

Rakow, Glenn↗

Measuring Permeability of Composite Cryotank Laminants

This paper describes a test method developed to identify whether certain materials and material systems are suitable candidates for large pressurized reusable cryogenic tanks intended for use in current and future manned launch systems. It provides a quick way to screen numerous candidate materials for permeability under anticipated loading environments consistent with flight conditions, as well as addressing reusability issues. cryogenic tank, where the major design issue was hydrogen permeability. It was successfully used to evaluate samples subjected to biaxial loading while maintaining test temperatures near liquid hydrogen. After each sample was thermally preconditioned, a cyclic pressure load was applied to simulate the in-plane strain. First permeability was measured while a sample was under load. Then the sample was unloaded and allowed to return to ambient temperature. The test was repeated to simulate reusability, in order to evaluate its effects on material permeability.

Oliver, Stanley T.↗

Concentrations of CH4, CO, CO2, H2, H2O and N2O in the upper stratosphere

On 23 May 1973 a cryogenic air sampler was flown on an Aerobee rocket from White Sands Missile Range. A large air sample was collected between 40 and 50 km altitude and successfully recovered for water vapor and trace gas analysis. The results were as follows: water vapor, 4.0 (+1.3 or - 0.9) ppmV; methane, 0.37 + or - 0.01 ppmV; molecular hydrogen, 0.47 + or - 0.02 ppmV; carbon monoxide, 0.05 + or - 0.01 ppmV; carbon dioxide, 316.2 + or - 2.8 ppmV; and nitrous oxide, 3 + or - 7 ppb.

Ehhalt, D. H.↗

Direct determination of the morphology, structure and composition of cometary and interstellar ice analogs in the laboratory

Ices of various kinds (H2O, CO, CO2, CH4, NH3, CH3OH, etc.) comprise a volumetrically significant proportion of objects in the solar system (comets, outer planets, planetary rings, satellites) as well as in interstellar space (astrophysical ices). The refinement of analytical electron microscopy (AEM) procedures for storing, preparing and analyzing ices and other materials at cryogenic temperatures is discussed. These procedures will be essential to the successful analysis of returned comet nucleus samples.

Blake, D. F.↗

The 1990 vertical distribution of two important halons (F-12B1 and F-13B1) in the tropics

The first vertical profiles of F-12B1 and F-13B1 had been obtained in the tropical troposphere and stratosphere by us in 1987. The measurement of these substances responsible for almost the entire anthropogenic contribution to the stratospheric BrO(x) budget is important in the tropics, as tropical upwelling provides their injection along with that of other pollutants, into the stratosphere. To ascertain the trends of these distributions and foster the data, the 1987 experiment was repeated in April 1990. Like 1987, the MPAE cryogenic whole air sampler was launched on a balloon from Hyderabad, India (17.5 deg N), and 14 samples were collected between 10 and 35 km altitude. The results obtained by means of GC and GC-MS analyses showed that the atmospheric abundance of both F-12B1 and F-13B1 is increasing at a fast rate, respectively by about 15 percent and 10 percent per year. From 1987 to 1990, F-12B1 and F-13B1 tropospheric mixing ratios have been growing from 1.2 and 1.3 ppt to 1.8 and 1.7 ppt, respectively. The vertical profiles will be discussed.

Singh, O. N.↗

Optimized Geometry for Superconducting Sensing Coils

An optimized geometry has been proposed for superconducting sensing coils that are used in conjunction with superconducting quantum interference devices (SQUIDs) in magnetic resonance imaging (MRI), magnetoencephalography (MEG), and related applications in which magnetic fields of small dipoles are detected. In designing a coil of this type, as in designing other sensing coils, one seeks to maximize the sensitivity of the detector of which the coil is a part, subject to geometric constraints arising from the proximity of other required equipment. In MRI or MEG, the main benefit of maximizing the sensitivity would be to enable minimization of measurement time. In general, to maximize the sensitivity of a detector based on a sensing coil coupled with a SQUID sensor, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. Simply making the coil larger may increase its self-inductance and does not necessarily increase sensitivity because it also effectively increases the distance from the sample that contains the source of the signal that one seeks to detect. Additional constraints on the size and shape of the coil and on the distance from the sample arise from the fact that the sample is at room temperature but the coil and the SQUID sensor must be enclosed within a cryogenic shield to maintain superconductivity.

Eom, Byeong Ho↗

Applications of a general thermal/hydraulic simulation tool

The analytic techniques, sample applications, and development status of a general-purpose computer program called SINDA '85/FLUINT (for systems improved numerical differencing analyzer, 1985 version with fluid integrator), designed for simulating thermal structures and internal fluid systems, are described, with special attention given to the applications of the fluid system capabilities. The underlying assumptions, methodologies, and modeling capabilities of the system are discussed. Sample applications include component-level and system-level simulations. A system-level analysis of a cryogenic storage system is presented.

Cullimore, B. A.↗