Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with Low Transition-Edge-Sensor Transition Temperature

We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3-inch diameter, 1-inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels. The phonon energy is then parsed into TES based phonon readout channels and input into a TES simulator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooling systems for satellite remote sensing instrumentation

The current and developing state-of-the-art in cryogenic coolers for satellite sensors was studied for earth oriented satellites. Six representative sensor categories in the 77 K to 300 K range were defined. Cooling capacities were 50 to 1000 mw; both continuous and intermittent duty cycles were considered; lifetimes were one to two years. Conceptual designs were prepared for the most promising coolers in each category. These coolers are Joule-Thomson, Solid Cryogen, Vuilleumier, Thermoelectric, Shielded Radiator, Optical Solar Reflector Radiator and Unshielded Radiator. Weight, envelope, power requirements and operating characteristics of each cooler are described. Scaling data for each cooler are included.

Copeland, R. J.↗

Local Leak Detection and Health Monitoring of Pressurized Tanks

An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

Polzin, Kurt↗

Sensitivity of Proposed Search for Axion-induced Magnetic Field using Optically Pumped Magnetometers

We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014)]. The modification of Maxwell’s equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. Here, we discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10 -7 GeV -1 for an axion mass near 3 × 10 -10 eV, which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10 -1 and 10 -7 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronically scanned multichannel pressure transducer system for cryogenic environments

Research into the application of custom doped piezoresistive silicon pressure sensors has led to a multichannel pressure sensor design that will operate accurately and reliably at cryogenic temperatures. The thermal effects upon multichannel pressure sensors are mapped by thermal calibrations and are represented by sets of nth order coefficients specific to each sensor. The thermal offset and sensitivity variations are corrected by computer algorithms which scan the sensors, recall correction coefficients from thermally induced sensor variations, and apply these to correct the sensor's output measurement uncertainty to within 0.5 percent of full scale output for combined offset and sensitivity. A prototype sensor system has been fabricated, and performance test data are presented.

Chapman, John J.↗

Physics Simulation Software for Autonomous Propellant Loading and Gas House Autonomous System Monitoring

1. Kennedy Space Center (KSC) is developing a mobile launching system with autonomous propellant loading capabilities for liquid-fueled rockets. An autonomous system will be responsible for monitoring and controlling the storage, loading and transferring of cryogenic propellants. The Physics Simulation Software will reproduce the sensor data seen during the delivery of cryogenic fluids including valve positions, pressures, temperatures and flow rates. The simulator will provide insight into the functionality of the propellant systems and demonstrate the effects of potential faults. This will provide verification of the communications protocols and the autonomous system control. 2. The High Pressure Gas Facility (HPGF) stores and distributes hydrogen, nitrogen, helium and high pressure air. The hydrogen and nitrogen are stored in cryogenic liquid state. The cryogenic fluids pose several hazards to operators and the storage and transfer equipment. Constant monitoring of pressures, temperatures and flow rates are required in order to maintain the safety of personnel and equipment during the handling and storage of these commodities. The Gas House Autonomous System Monitoring software will be responsible for constantly observing and recording sensor data, identifying and predicting faults and relaying hazard and operational information to the operators.

Regalado Reyes, Bjorn Constant↗

Development of FD-SOI cryogenic amplifier for application to STJ readout in COBAND project

The COBAND is a project of an experimental search for the cosmic background neutrino decay [1] – [9] . The existence of the cosmic background neutrino is predicted as a relic of the big bang in the theoretical cosmology. Since the neutrino is found to have mass generations and mixing between them, a heavier neutrino is possible to decay to a lighter neutrino with a far-infrared photon, even though its lifetime is expected to be much longer than the age of the universe [10] . However, neither the cosmic background neutrino nor the neutrino decay is yet established experimentally. Only a lower limit in the order of 10 12 years is given on the heaviest neutrino lifetime. We, thus, search for photons which come from the cosmic background neutrino decays. The photons from the cosmic background neutrino decays are expected to shape a spectrum of a unique signature with a sharp edge at a wavelength of around 50μm depending on the heaviest neutrino mass. To identify the signature against the overwhelming zodiacal emission foreground as well as the cosmic infrared background, the photodetectors are required to have an ability to measure the FIR spectrum around 50pm with sufficient precision. Thus, we aim at developing a photodetector with capability of FIR photon-by-photon spectrometry. We employ superconducting tunnel junction (STJ) sensors in combination with cryogenic amplifiers for signal readout to maximize the potential of STJ.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute pressure transducers for space shuttle and orbiter propulsion and control systems

A preliminary design was completed, reviewing of such subjects as: the trade studies for media isolation and one sensor vs. two sensors for two bridges; compensation resistors; unit design; hydrogen embrittlement; sealing techniques and test station design. A design substantiation phase was finished, consisting of testing of a prototype unit and fabrication technique studies. A cryogenic test station was implemented and prototype sensor cells were fabricated, sensors assembled, and cryogenic tests performed.

Bolta, J. J.↗

Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes

Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

Daryabeigi, K.↗

Thermal sensing of cryogenic wind tunnel model surfaces - Evaluation of silicon diodes

Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

Daryabeigi, Kamran↗

Techniques for improving the accuracy of cryogenic temperature measurement in ground test programs

The performance of a sensor is often evaluated by determining to what degree of accuracy a measurement can be made using this sensor. The absolute accuracy of a sensor is an important parameter considered when choosing the type of sensor to use in research experiments. Tests were performed to improve the accuracy of cryogenic temperature measurements by calibration of the temperature sensors when installed in their experimental operating environment. The calibration information was then used to correct for temperature sensor measurement errors by adjusting the data acquisition system software. This paper describes a method to improve the accuracy of cryogenic temperature measurements using corrections in the data acquisition system software such that the uncertainty of an individual temperature sensor is improved from plus or minus 0.90 deg R to plus or minus 0.20 deg R over a specified range.

Dempsey, Paula J.↗

Detector and Readout Assembly and Characterization for the Simons Array

The Simons Array (SA) is a cosmic microwave background (CMB) polarization experiment comprised of three telescopes that will observe the CMB at 90, 150, 220, and 270GHz with more than 22,000 Transition Edge Sensor (TES) bolometers. The cryogenic receivers inside each telescope are named POLARBEAR-2a, POLARBEAR-2b, and POLARBEAR-2c (PB-2a, PB-2b, and PB-2c, respectively). To allow for the large number of detectors, SA uses frequency-division multiplexing with multiplexing factor of 40. We describe the process developed to assemble the readout circuit repeatably for SA. After assembly, we characterize the readout circuit and TESs at cryogenic temperatures in a condition of negligible incident optical power. Impedances in the readout circuit bias our estimates of TES parameters, and we describe a method to account for this.

cosmic microwave background↗

Terrestrial density of strongly-coupled relics

The simplest cosmologies motivate the consideration of dark matter subcomponents that interact significantly with normal matter. Moreover, such strongly coupled relics may have evaded detection to date if upon encountering the Earth they rapidly thermalize down to terrestrial temperatures, T ⊕ ∼ 300 K ∼ 25 meV , well below the thresholds of most existing dark matter detectors. This shedding of kinetic energy implies a drastic enhancement to the local density, motivating the consideration of alternative detection techniques sensitive to a large density of slowly moving dark matter particles. In this work, we provide a rigorous semianalytic derivation of the terrestrial overdensities of strongly coupled relics, with a particular focus on millicharged particles (MCPs). We go beyond previous studies by incorporating improved estimates of the MCP-atomic scattering cross section, new contributions to the terrestrial density of sub-GeV relics that are independent of the Earth’s gravitational field, and local modifications that can arise due to the cryogenic environments of precision sensors. We also generalize our analysis in order to estimate the terrestrial density of thermalized MCPs that are produced from the collisions of high-energy cosmic rays and become bound by the Earth’s electric field. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A reliable liquid helium detector

Detector and indicator system, utilizing commercial perforated germanium cryogenic thermometer as level sensor containing adjustable level discriminator with indicators, operates reliably over pressure range from 50 to 900 mm Hg without electronic adjustments.

Krawczonek, W. M.↗

OAST Space Theme Workshop. Volume 3: Working group summary. 7: Material (M-1). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2)

The approach of matching technology areas with various themes needs was not effective for the materials and thermal control discipline because of the diversity of requirements for each. Top priorities were evolved from the advanced space transportation system and the space power platform because these are essential building blocks in fulfilling some of the other themes. Important needs identified include life long-life cryogenic cooling systems for sensors, masers, and other devices and the needs for lightweight nuclear shielding materials for nuclear electric propulsion.

Source record↗

Spaceborne Gravity Gradiometers. Part 4: Common problems

Important issues and possible solutions in the development of gravity gradiometers are examined with emphasis on problems related to: (1) sensors (both) conventional and cryogenic; (2) laboratory, spacecraft environment, and orbital flight tests; (3) spacecraft design (attitude and vibration control, propulsion and tether systems, and cryogenic systems); and (4) on-board and ground data processing.

Source record↗

Mass flow measurement of liquid cryogens using the triboelectric effect

A cross correlator technique using triboelectric technology has been shown to be a feasible method to measure liquid flow rate for liquid nitrogen and JP4 jet fuel. This technology, invented and pioneered by Auburn International, Inc., is also expected to be suitable for use with all other insulating liquids and cryogens. The technology described is particularly well suited for cryogenic use, since the sensor is non-contacting and non-intrusive, and therefore, causes no additional pressure drop within the flow stream. Further development of the in-line sensor is required to produce a prototypical version for the test purposes under SSME fuel flow conditions. However, with the knowledge gained from this feasibility study, it is very likely that an acceptable sensor design for a full test bed evaluation could be produced.

Dechene, Ronald L.↗