Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cassette bacteria detection system

The design, fabrication, and testing of an automatic bacteria detection system, with a zero-g capability, based on the filter-capable approach, and intended for monitoring the sterility of regenerated water in spacecraft is discussed. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. High signals for the incubated water sample indicate the presence of viable organisms.

Source record↗

Acoustic Wafer Defect Detection System

Researchers at Los Alamos have developed the Acoustic Wafer Defect Detection System, a technology that enables rapid diagnosis of critical defects during wafer production. This technology is capable of both efficient and accurate detection of defects in wafers, including defects that are undetectable through current optical techniques. The system identifies the wafer defects by exciting resonant vibrations in the wafers and by exciting “crack breathing” modes. These vibrations cause the crack to periodically open and close. Specific resonance characteristics, combined with acoustic signatures resulting from crack breathing, result in a technique that is highly sensitive to cracked wafers. There are minimal custom parts used to build the system, and it can be easily implemented in nearly any wafer production plant with minimal modifications. We are seeking a commercialization partner to license the technology or partner through a Cooperative Research and Development Agreement (CRADA) to develop into a usable product for commercial purposes.

42 ENGINEERING↗

Progress in Development of an Airborne Turbulence Detection System

Aircraft encounters with turbulence are the leading cause of in-flight injuries (Tyrvanas 2003) and have occasionally resulted in passenger and crew fatalities. Most of these injuries are caused by sudden and unexpected encounters with severe turbulence in and around convective activity (Kaplan et al 2005). To alleviate this problem, the Turbulence Prediction and Warning Systems (TPAWS) element of NASA s Aviation Safety program has investigated technologies to detect and warn of hazardous in-flight turbulence. This effort has required the numerical modeling of atmospheric convection: 1) for characterizing convectively induced turbulence (CIT) environments, 2) for defining turbulence hazard metrics, and 3) as a means of providing realistic three-dimensional data sets that can be used to test and evaluate turbulence detection sensors. The data sets are being made available to industry and the FAA for certification of future airborne turbulence-detection systems (ATDS) with warning capability. Early in the TPAWS project, a radar-based ATDS was installed and flight tested on NASA s research aircraft, a B-757. This ATDS utilized new algorithms and hazard metrics that were developed for use with existing airborne predictive windshear radars, thus avoiding the installation of new hardware. This system was designed to detect and warn of hazardous CIT even in regions with weak radar reflectivity (i.e. 5-15 dBz). Results from an initial flight test of the ATDS were discussed in Hamilton and Proctor (2002a; 2002b). In companion papers (Proctor et al 2002a; 2002b), a numerical simulation of the most significant encounter from that flight test was presented. Since the presentation of these papers a second flight test has been conducted providing additional cases for examination. In this paper, we will present results from NASA s flight test and a numerical model simulation of a turbulence environment encountered on 30 April 2002. Progress leading towards FAA certification of industry built ATDS will also be discussed.

Hamilton, David W.↗

The ICARUS light detection system (Fermilab Italian summer student program 2023)

The ICARUS T600 detector is the largest Liquid Argon Time Projection Chamber ever used on a neutrino beam, and it acts as the far detector of the Short Baseline Neutrino program at Fermilab. Its purpose is the study of the possibility of the existence of a fourth sterile neutrino in the O(eV2) mass range that could take part in the neutrino oscillations. The light detection system of the ICARUS detector plays the role of localising in space and time the neutrino interactions taking place inside the detector, collecting the argon scintillation photons generated when an event occurs. This light detection system also has a crucial role in the trigger system and the rejection of the huge amount of background cosmic events, working together with the trigger request signals sent by the beam complex. In August 2023 part of the cables that are used to carry the signals from the photomultipliers to the electronics were replaced with a new model, because a deterioration of the quality of the signal inside the cables had previously been observed. An analysis of the performance of the new cables was carried out, comparing laser run data collected before and after the change of the cable model, and it was proved that the introduction of the new cables lead to a general improvement of the quality of the signals reaching the electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FINDS: A fault inferring nonlinear detection system. User's guide

The computer program FINDS is written in FORTRAN-77, and is intended for operation on a VAX 11-780 or 11-750 super minicomputer, using the VMS operating system. The program detects, isolates, and compensates for failures in navigation aid instruments and onboard flight control and navigation sensors of a Terminal Configured Vehicle aircraft in a Microwave Landing System environment. In addition, FINDS provides sensor fault tolerant estimates for the aircraft states which are then used by an automatic guidance and control system to land the aircraft along a prescribed path. FINDS monitors for failures by evaluating all sensor outputs simultaneously using the nonlinear analytic relationships between the various sensor outputs arising from the aircraft point mass equations of motion. Hence, FINDS is an integrated sensor failure detection and isolation system.

Lancraft, R. E.↗

Autoencoder-Based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online data quality monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. In addition, the first results from deploying the autoencoder-based system in the CMS online data quality monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Detection System for Determination of the Biotic or Abiotic Origin of Amino Acids

The research carried out under this PIDDP involves the development of a breadboard version of a spacecraft-based system for the detection of amino acid chirality (molecular handedness) on solar system bodies. Chirality provides an unambiguous way of distinguishing between abiotic and biotic origins since only one mirror-image form is used in the functional molecules of life. Recent advances in a variety of nano-fabrication technologies have resulted in concepts for enabling miniaturized chemical and biological analytical systems. These are complete application-specific systems that integrate fluid micro handling systems for extracting and reacting target molecules, micro-separation technologies for enhanced sensitivity and resolution, and advanced detection technologies. This effort makes use of a relatively new technology that shows demonstrated promise for spacecraft-based amino acid analysis: microchip-based capillary electrophoresis (μCE). The μCE system is capable of analyzing the type of amino acids present as well as the relative amounts of their mirror image forms. The system we developed will be able to chirally resolve all of the major amino acids found in extraterrestrial material (Gly, Ala, Val, Pro, Asp, Glu, a-aminoisobutyric acid, and isovaline) at sub-part-per-billion levels. The -CE analysis requires that the amino acids be extracted from the sample and derivatized for either optical or electrochemical detection. In our implementation, the amino acids are released from the sample by sublimation and prepared for μCE analysis using a microfluidic circuit. In addition, we have investigated the use of a microfluidic circuit for the release of amino acids from samples in which sublimation has proven to be problematic.

Jeffrey L Bada↗

Use of the moon and the large space telescope as an extrasolar planet detection system

Roman (1959), Spitzer (1962), and Huang (1973) have discussed photometric detection of extrasolar planets using a 3-m space telescope such as the Large Space Telescope (LST). A space telescope could be an extrasolar planet detection system if used in conjunction with an occulter placed 10,000 km in front of the telescope. The occulter would reduce the amount of light received from the star under observation. For a semi-infinite plane occulter 10,000 km in front of the telescope, Spitzer and Huang's results indicate that a Jupiter-like planet would be observed with a signal/noise of 1.00, for observations at 0.4 micron using a 3-m telescope like the LST.

Matloff, G. L.↗

Scintillation Light Detection System in LArIAT

The LArIAT experiment is currently taking data at Fermilab using a Liquid Argon TPC, with the aim of studying particle interactions and characterizing detector response for neutrino detectors using argon. In parallel, it serves as a test-bench to develop and evaluate the performance of the simulation, reconstruction, and analysis software used in LAr neutrino experiments. LArIAT also takes advantage of the scintillating capabilities of liquid argon and will evaluate the feasibility of using the light signal to determine calorimetric information and particle identification. To test this possibility, a scintillation light detection system consisting of high Quantum Efficiency (QE) PMT and Silicon Photomultiplier (SiPM) devices is installed in the cryostat, viewing the interior of the TPC. Light collection efficiency is maximized by means of lining the walls with reflector foils covered by a wavelength shifter layer. Collecting the light reflected at the boundaries of the active volume greatly improves also the uniformity of the light yield. Presented here are initial results of the LArIAT light detection system calibration together with the preliminary results of the dedicated simulation and its application in future LAr TPC experiments

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical imaging module for astigmatic detection system

In this paper, an optical imaging module design for an astigmatic detection system (ADS) is presented. The module is based on a commercial optical pickup unit (OPU) and it contains a coaxial illuminant for illuminating a specimen. Furthermore, the imaging module facilitates viewing the specimen and the detection laser spot of the ADS with a lateral resolution of approximately 1 μm without requiring the removal of an element of the OPU. Two polarizers and one infrared filter are used to eliminate stray laser light in the OPU and stray light produced by the illuminant. Imaging modules designed for digital versatile disks (DVDs) and Blu-ray DVDs were demonstrated. Furthermore, the module can be used for imaging a small cantilever with approximate dimensions of 2 μm (width) × 5 μm (length), and therefore, it has the potential to be used in high-speed atomic force microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zero Trust Strategies for Chemical, Biological, Radiological, and Nuclear Detection Systems: D.1 Cyber Scenarios

The evolving landscape of cybersecurity necessitates a paradigm shift to a Zero Trust (ZT) model, which assumes breaches and continuously verifies trust. This approach reshapes how trust boundaries are established, focusing on identities, devices, networks, applications, and data, rather than solely relying on perimeter defenses such as firewalls. Central to this transformation is the National Institute of Standards and Technology's (NIST) Special Publication 800-207, outlining the Zero Trust Architecture (ZTA), along with Executive Order 14028, which mandates federal agencies to adopt ZT principles. Complementary to these efforts, the Cybersecurity and Infrastructure Security Agency (CISA) developed the Zero Trust Maturity Model (ZTMM), providing a framework with five pillars and three cross-cutting capabilities to guide agencies toward enhanced cybersecurity maturity. In support of these initiatives, the DHS Countering Weapons of Mass Destruction Office (CWMD) is applying ZT principles to secure Chemical, Biological, Radiological, and Nuclear (CBRN) detection systems. Recognizing the diverse deployment models and network connectivity of these systems—from stationary, non-networked units to mobile, cloud-connected devices—the Pacific Northwest National Laboratory (PNNL) is developing cybersecurity scenarios specifically for CBRN environments. These scenarios examine various configurations and technological capabilities, offering insights into the application of ZTMM pillars in enhancing the security postures of CBRN devices. The cybersecurity scenarios presented by PNNL are hypothetical, crafted to explore theoretical situations and stimulate discussion on the potential use or compromise of CBRN detection systems in varied contexts. These narratives are illustrative and do not reference any real events or actual networks. Instead, they employ generalized reference models to highlight concepts and potential issues within CBRN security, focusing on how Zero Trust strategies can be adapted to address these challenges effectively.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Challenges of Using Real-Time Detection Systems: From Data Gathering to Actionable Information [Slides]

This session will discuss challenges and real life examples associated with Real-Time Detection Systems (RTDS) used in exposure assessment strategies. This first presentation will provide an overview of RTDS as used as part of an overall exposure assessment strategy and to document regulatory compliance. Managing OH consequences has been problematic when it comes to actionable information gleaned from sensor data. The judgement of regulatory entities, can be at odds with IH practitioners implementing an exposure strategy that creates exposure profiles and judges workplace exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-channel optical detection system and method for multi-chamber assays

A multi-channel optical detection system includes a base unit adapted to receive a multi-chamber assay cartridge having a plurality of reaction chambers loaded with a sample and an optical detection reagent, and an optical detection unit having a multi-channel optical block having a plurality of detection channels each with an associated light source, and an optic sensor. The optical detection unit is connectable to the base unit so that interrogation ports of the detection channels are optically aligned with optically transparent windows of the reaction chambers of a loaded cartridge, so that upon initialization, light sources are activated to interrogate reaction products in the reaction chambers and detect the optical responses therefrom.

Dugan, Lawrence C.↗

HICO and RAIDS Experiment Payload - Remote Atmospheric and Ionospheric Detection System (RAIDS)

The HICO and RAIDS Experiment Payload - Remote Atmospheric and Ionospheric Detection System (HREP-RAIDS) experiment will provide atmospheric scientists with a complete description of the major constituents of the thermosphere (layer of the Earth's atmosphere) and ionosphere (uppermost layer of the Earth's atmosphere), global electron density profiles at altitudes between 100 - 350 kilometers.

Budzien, Scott↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗