Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose response model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Notice of Submittal – 2023 Radionuclide Air Emissions Report for Los Alamos National Laboratory

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2023 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.43 for 2023. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2023, LANL continuously monitored radionuclide emissions at 28 “major” release points, or stacks. The Laboratory estimates emissions from an additional 59 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2023, this MEI location was a business at 129 New Mexico State Road 4 (NM-4), located in the northern end of White Rock. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2023 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Evaluation of Potassium Iodide Implementation Strategies for Emergency Preparedness and Response

This study evaluates the effectiveness of potassium iodide (KI) distribution strategies in mitigating exposure to radioiodine during severe nuclear power plant accidents. This analysis quantitatively compares various KI distribution methods (pre-distributed versus stockpiles), including scenarios with and without KI administration. The results indicate that differences in distribution strategies impact the projected thyroid dose by at least an order of magnitude. The results also indicate that the timing of KI administration is critical, as expected. For scenarios involving delayed releases of significant quantities of radionuclides, evacuation is the most effective protection strategy regardless of KI distribution method. For scenarios involving rapid releases, retrieving KI from stockpiles can have a detrimental effect. Pre-distributed KI is potentially the most effective approach when used as a supplement to evacuation and sheltering. However, these model results are based on idealized conditions for KI distribution and administration; the actual benefits of KI prophylaxis are likely to be less than estimated in this report due to many variables. The results highlight the importance of considering the cost and rigor of different distribution programs and public compliance with emergency instructions. This report includes suggested research to explore KI distribution plans for advanced reactors.

59 BASIC BIOLOGICAL SCIENCES↗

CD8 Lymphocyte Depletion Enhances the Latency Reversal Activity of the SMAC Mimetic AZD5582 in ART-Suppressed Simian Immunodeficiency Virus-Infected Rhesus Macaques

ABSTRACT Inducing latency reversal to reveal infected cells to the host immune system represents a potential strategy to cure human immunodeficiency virus (HIV) infection. In separate studies, we have shown previously that CD8 + T cells may contribute to the maintenance of viral latency and have identified a novel SMAC (second mitochondrial activator of caspases) mimetic/IAP (inhibitor of apoptosis protein) inhibitor (AZD5582) capable of reversing HIV/simian immunodeficiency virus (SIV) latency in vivo by activating the noncanonical (nc) NF-κB pathway. Here, we use AZD5582 in combination with antibody (Ab)-mediated depletion of CD8α + cells to further evaluate the role of CD8 + T cells in the maintenance of viral latency. Six rhesus macaques (RMs) were infected with SIV mac239 and treated with antiretroviral therapy (ART) starting at week 8 postinfection. After 84 to 85 weeks of ART, all animals received a single dose of the anti-CD8α depleting Ab MT807R1 (50 mg/kg of body weight, administered subcutaneously [s.c.]), followed by five weekly doses of AZD5582 (0.1 mg/kg, administered intravenously [i.v.]). Following combined treatment with CD8α depletion and AZD5582, 100% of RMs experienced on-ART viremia levels above 60 copies per ml of plasma. In comparator groups of SIV-infected, ART-suppressed RMs treated with AZD5582 only or CD8α depletion only, on-ART viremia was experienced by 56% and 57% of the animals, respectively. Furthermore, the increased frequency of viremic episodes during the treatment period was greater in the group treated with CD8α depletion plus AZD5582 than in the other groups. Mathematical modeling of virus reactivation suggested that in addition to viral dynamics during acute infection, CD8α depletion influenced the response to AZD5582. This work suggests that the latency reversal induced by activation of the ncNF-κB signaling pathway with AZD5582 can be enhanced by CD8α + cell depletion. IMPORTANCE A favored approach to curing HIV infection aims at inducing viral expression using latency-reversing agents (LRAs) to allow the elimination of infected cells. Here, we tested a combination of two recently identified LRAs, the SMAC mimetic/IAP inhibitor AZD5582, which activates the noncanonical NF-κB pathway, and the antibody (Ab) MT807R1, which depletes CD8α + cells, in SIV-infected rhesus macaques (RMs) on ART. Latency reversal, as defined by increased on-ART viremia, was observed in all six SIV-infected, ART-treated RMs that received this combined treatment. Furthermore, comparison of viral reactivation between these animals and groups of SIV-infected, ART-treated RMs treated with AZD5582 only or CD8α + cell depletion only showed more frequent increases in viremic episodes when the two treatments were combined. This study provides additional evidence that CD8 + T cells may contribute to the maintenance of HIV/SIV latency on ART and potentially inhibit latency reversal during HIV cure approaches.

59 BASIC BIOLOGICAL SCIENCES↗

High-throughput platform for yeast morphological profiling predicts the targets of bioactive compounds

Abstract Morphological profiling is an omics-based approach for predicting intracellular targets of chemical compounds in which the dose-dependent morphological changes induced by the compound are systematically compared to the morphological changes in gene-deleted cells. In this study, we developed a reliable high-throughput (HT) platform for yeast morphological profiling using drug-hypersensitive strains to minimize compound use, HT microscopy to speed up data generation and analysis, and a generalized linear model to predict targets with high reliability. We first conducted a proof-of-concept study using six compounds with known targets: bortezomib, hydroxyurea, methyl methanesulfonate, benomyl, tunicamycin, and echinocandin B. Then we applied our platform to predict the mechanism of action of a novel diferulate-derived compound, poacidiene. Morphological profiling of poacidiene implied that it affects the DNA damage response, which genetic analysis confirmed. Furthermore, we found that poacidiene inhibits the growth of phytopathogenic fungi, implying applications as an effective antifungal agent. Thus, our platform is a new whole-cell target prediction tool for drug discovery.

59 BASIC BIOLOGICAL SCIENCES↗

A Tool Kit for Generating Simulated Radiation Measurements for Advanced Reactor Safeguards and Security

A tool kit was developed to simulate and analyze passive radiation measurements of molten salt reactor (MSR) operations to support development of nuclear safeguards approaches for this emerging reactor technology. A Transient Simulation Framework of Reconfigurable Modules (TRANSFORM) multiphysics simulation of an MSR produces time-dependent isotopic inventories at user-selected locations within the model. The tool kit implements the Gamma Detector Response and Analysis Software (GADRAS) application programming interface to inject the TRANSFORM isotopic inventories extracted/processed by a Python pipeline into GADRAS models of user-defined geometries. The TRANSFORM inventories are the source terms used to obtain synthetic measurements from GADRAS-defined detectors. The speed of TRANSFORM and GADRAS simulations enables surveying the large design space of MSRs (e.g., fuel type, fuel salt composition, number of loops) and the plethora of measurements (e.g., location, detector type, and collimation) within the reactor. This has enabled timely assessment of the various measurement locations and detectors to identify the most effective and efficient safeguards approach for a specific MSR design. Lastly, the tool kit also simulates extracted samples that can be aged to a desired dose, enabling stakeholders to optimize a measurement plan to use sample analysis as an element within a broader material accountancy plan.

Westphal, Greg↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium indium diselenide — An advanced material for neutron detection

Here, this paper describes the synthesis, crystal growth, detector fabrication, radiation hardening studies, MCNP modeling, and characterization of lithium indium diselenide or LiInSe 2 . This newly-developed room temperature thermal neutron detector has semiconducting and scintillating properties and it is suitable for neutron detection application. LiInSe 2 was synthesized starting from elemental Li, In, Se in two steps due to high reactivity of Li. A single crystal of LiInSe 2 was grown using the Vertical Bridgman method. The room temperature band gap was found to be 2.8 eV using optical absorption measurements. Bulk resistivity was measured at ∼5 × 10 11 Ωcm. Photoconductivity measurements of LiInSe 2 wafers identified a peak in the photocurrent around 445 nm. Nuclear radiation detectors were fabricated from single crystal wafer and the responses to alpha particles at various biases were measured. The mobility-lifetime product was estimated. Gamma irradiation studies were performed with calculated absorbed doses ranging from 0.2126 to 21,262 Gy. The characterization of the two wafers for their scintillator performance was conducted after each irradiation. The gamma irradiation produced a reduction of the light yield that translated to a lower channel number for the centroid of alpha detection spectra. It also showed a considerable reduction of the decay time after the first irradiation. These are the first studies on gamma radiation hardening with this material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES↗

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Multiband superconductivity in V 3 Si determined from studying the response to controlled disorder

The London penetration depth, λ(T), was measured in a single crystal V 3 Si. The superfluid density obtained from this measurement shows a distinct signature of two almost decoupled superconducting gaps. This alone is insufficient to distinguish between s ± and s ++ pairing states, but it can be achieved by studying the effect of a controlled non-magnetic disorder on the superconducting transition temperature, T c . For this purpose, the same V 3 Si crystal was sequentially irradiated by 2.5 MeV electrons three times, repeating the measurement between the irradiation runs. A total dose of 10 C/cm 2 (6.24 × 10 19 electrons/cm 2 ) was accumulated, for which T c has changed from 16.4 K in a pristine state to 14.7 K (9.3 %). This substantial suppression is impossible for a single isotropic gap, but also it is not large enough for a sign-changing s± pairing state. Our electronic band-structure calculations show how five bands crossing the Fermi energy can be naturally grouped to support two effective gaps, not dissimilar from the iron pnictides physics. We analyze the results using two-gap models for both, λ(T) and T c , which describe the data very well. Finally, the experimental results and theoretical analysis provide strong support for an s ++ superconductivity with two unequal gaps, Δ 1 (0) ≈ 2.53 meV and Δ 2 (0) ≈ 1.42 meV, and a very weak inter-band coupling in V 3 Si superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructural evolution in doped high entropy alloys NiCoFeCr-3X (X=Pd/Al/Cu) under irradiation

Commonly studied equatomic single-phase FCC high entropy alloys based on 3d transition metals like NiCoFeCr do not provide adequate strength and radiation resistance at high doses for nuclear structural applications. In the current study, the major alloying effects like lattice distortion, ordering and clustering tendencies were investigated by adding low concentration of Pd, Al, or Cu respectively to study the doping effects on the ion irradiation response of NiCoFeCr alloy. The alloys were irradiated with 3 MeV Ni 2+ ions at 500 °C to a fluence of 1 × 10 17 /cm 2 at a beam flux of approximately 2.8 × 10 12 ions/cm 2 /s. The microstructural evolution upon irradiation i.e., formation of dislocation networks, radiation induced segregation and precipitation, and void formation were studied in detail. Further, post-irradiation characterization results showed that a Pd addition leads to a high void nucleation rate but controlled void growth, which may be attributed to increased lattice distortion. In Al added HEA, our microstructural analysis indicates that radiation induced ordered L1 2 precipitates do not affect void swelling significantly. Cu addition led to Cu precipitation that drastically suppressed dislocation density and void swelling of the alloy. Additionally, a model was developed to qualitatively describe the trend in void swelling of typical FCC alloys under ion irradiation. This model was able to qualitatively explain the suppression and reappearance of void swelling in ion irradiated alloys that generally occurs near the region with peak implanted ion concentration.

36 MATERIALS SCIENCE↗

Non-Equilibrium Actinide Radiation Chemistry and the Nuclear Fuel Cycle

Actinides are inherently unstable elements that frequently coexist with other radioisotopes, generating intense ionizing radiation fields that drive the formation of non equilibrium oxidation states. These transient species exert a profound mechanistic influence on the radiation response of actinide containing systems due to their unique redox chemistry. Despite their importance, they remain poorly understood, yet such insight is essential for advancing actinide science and accurately predicting radiation driven behavior. Actinide separations—critical for nuclear energy technologies, strategic deterrence, space exploration, and nuclear medicine—depend on precise control of actinide oxidation states to recover targeted elements from complex matrices such as used nuclear fuel. However, during these processes, actinides, their coordination complexes, and the separation media are all exposed to intense, multicomponent (alpha, beta, gamma, etc.) radiation fields that can alter process efficiency, selectivity, and chemical stability. Understanding, controlling, and mitigating radiation induced reactions is therefore key to innovating and optimizing next generation separation technologies. This seminar will provide an overview of the nuclear fuel cycle and non equilibrium actinide radiation chemistry in the context of recovering actinides from used nuclear fuel, with a particular emphasis on direct dissolution–based reprocessing strategies. We will explore time resolved electron pulse radiolysis and alpha and gamma dose accumulation studies, integrated with multiscale computational modeling, to elucidate the molecular level roles of radiation driven, non equilibrium actinide species in process performance and in the radiolytic stability of organic ligands used for actinide recovery. These insights offer new pathways for designing advanced separation methods and next generation solvent systems, with broad implications for the future of the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Mechanisms of stored energy release in silicon carbide materials neutron-irradiated at elevated temperatures

Understanding the stored energy release behavior of SiC is crucial for the design of SiC-based fuel cladding for light water reactors because stored energy release affects response during accident conditions. Differential scanning calorimetry was used to evaluate the stored energy of monolithic SiC and SiC fiber–reinforced SiC matrix composite variants following neutron irradiation under light water reactor–relevant dose and temperature conditions. The tests were performed at heating rates of 0.5, 3, and 20 K/min up to 1,273 K. The onset temperature of the energy release roughly corresponded to the irradiation temperature, and energy release was delayed as the heating rate increased. The monolithic and composite specimens exhibited similar stored energy release behavior up to ~1,000 K, and above that temperature, the energy release depended more on material type. The energy release measured in this study is below the material-specific heat capacity at temperatures below ~1,000 K but exceeds it under certain material and annealing conditions at temperatures above ~1,000 K. The amount of irradiation-induced volumetric swelling of the specimens was an indication of the total stored energy. Based on this observation, the energy release behavior was described by a swelling recovery model.

36 MATERIALS SCIENCE↗

Contaminant Migration Modeling to Support the In Situ Decommissioning of Hardened Nuclear Facilities - 20215

The decommissioning of hardened nuclear facilities provides a unique challenge in balancing current worker dose with exposure to future receptors and media. In situ decommissioning (ISD) is a cost-effective and safe option for the closure of such facilities but requires a detailed understanding of the threat that radioactive and hazardous constituents remaining in the facilities pose to groundwater and surrounding surface water. The Savannah River Site (SRS) extensively employs contaminant migration models within the decommissioning process to develop site-specific removal, grouting, and monitoring strategies in support of safe and effective final end states of nuclear facilities. This work discusses the use of contaminant migration modeling in the ISD process at SRS, including specific examples from the closure of P-Reactor and R-Reactor, Building 235-F, F-Canyon and F/H Laboratory Complex. Migration models developed during the closure of P-Reactor and R-Reactor were divided into four source areas: the reactor vessel, the process area, the disassembly basin, and the purification wing. Each source area was assigned a specific inventory and migration pathway and was then subject to varying hypothetical removal, capping, and grouting schemes. Modeling indicated that groundwater Maximum Concentration Limits (MCLs) might be exceeded if no action was taken for eleven and ten constituents of concern (COCs) at P-Reactor and R-Reactor, respectively. These exceedances could occur in as few as 200 to 500 years. Alternatively, the migration modeling demonstrated that the selected ISD actions reduced contaminant mobility which allowed for significant radioactive decay and resulted in fewer predicted exceedances of groundwater MCLs (five COCs for P-Reactor; eight COCs for R-Reactor). In response to the modeling results for P-Reactor and R-Reactor, effectiveness monitoring programs were developed to target contaminants, specific to each reactor, that may migrate to groundwater. Contaminant migration modeling also revealed that roof collapse was a large factor in the release of COCs to the environment, giving rise to roof improvements, and an inspection and vegetation control program to ensure roof stability over time. Contaminant migration modeling is also aiding in the closure planning for hardened facilities in F Area. Building 235-F housed the Actinide Billet Line, which produced Np-237 billets for irradiation in SRS reactors, and the Plutonium Fuel Form (PuFF) facility that produced Pu-238 heat sources for the space program. As a result of these missions, areas within Building 235-F contain considerable residual amounts of both Pu-238 and Np-237. Contaminant migration modeling of Building 235-F was originally performed in 2012 to identify the feasibility of ISD and the amount of radioactive material removal required to prevent the exceedance of groundwater MCLs. The original model indicated that a 60% reduction in the PuFF facility Pu-238 inventory could keep groundwater concentrations below standards, while Np-237 did not pose a threat to groundwater. However, updates to the model with an emphasis on source impact pathways revealed that, due to the orientation of the source areas relative to groundwater flow, no amount of reasonable removal of Pu-238 would keep groundwater concentrations below MCLs and that Np-237 could be a large contributor to localized MCL exceedances. With this insight, the refined 2019 model is being used to assist in the development of grouting plans specific to each facility source area, where bentonite may be utilized to slow the migration of Pu-238 and its daughter products from the PuFF facility and a reducing grout may decrease Np-237 transport by ensuring the nuclide remains in the less mobile +IV oxidation state. The beginning phases of contaminant migration modeling are underway for F-Canyon and associated facilities using lessons learned from the Reactors and Building 235-F. A contaminant migration pathway, similar to the pathway used for the reactor vessels, is being developed for the hot and warm canyons. The F-Canyon inventories are being spatially refined to identify specific and localized source zones, comparable to Building 235-F, that may impact groundwater. Contaminant migration modeling provides vital input within the ISD process, from facility investigation to post closure effectiveness monitoring, making it a valuable tool in the development of safe and effective end states for hardened nuclear facilities at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Immunomodulation by cannabidiol in bovine primary ruminal epithelial cells

Ruminant livestock experience a number of challenges, including high concentrate diets, weaning and transport, which can increase their risk of disorders such as ruminal acidosis, and the associated inflammation of the ruminal epithelium. Cannabidiol (CBD), a phytochemical from hemp (Cannabis sativa), is a promising target as a therapy for gastrointestinal inflammation, and may be extremely valuable as either a treatment or prophylactic. However, the effects of CBD in the the ruminant gastrointestinal tract have not been explored, in part due to the restrictions on feeding hemp to livestock. Therefore, the objective of this study was to investigate the immunomodulatory properties of CBD using a model of inflammation in primary ruminal epithelial cells (REC). In addition, CBD dose was evaluated for possible cytotoxic effects. Negative effects on cell viability were not observed when REC were exposed to 10 μM CBD. However, when the dose was increased to 50 μM for 24 h, there was a significant cytotoxic effect. When 10 μM CBD was added to culture media as treatment for inflammation induced with lipopolysaccharide (LPS), expression of genes encoding for pro-inflammatory cytokine IL1B was less compared to LPS exposure alone, and CBD resulted in a down-regulation of IL6. As a pre-treatment, prior to LPS exposure, REC had decreased expression of IL6 and CXCL10 while CBD was present in the media, but not when it was removed prior to addition of LPS. Results suggest that CBD may reduce cytokine transcription both during LPS-induced inflammation and when used preventatively, although these effects were dependent on its continued presence in the culture media. Overall, these experiments provide evidence of an immunomodulatory effect by CBD during a pro-inflammatory response in primary REC in culture.

59 BASIC BIOLOGICAL SCIENCES↗