Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Modeling and Analysis of Wind Turbine Wake Vortex Evolution Due to Time-Constant Spatial Variations in Atmospheric Flow

Modern utility-scale wind turbines are evolving toward larger, lighter, and more flexible designs to meet the growing demand for renewable energy while minimizing logistical costs. However, these advancements in lightweight design result in heightened aeroelastic sensitivity, leading to complex interactions which affect the rotor’s capacity to withstand aerodynamic loading and the cascading effects that manifest in the wake’s vortex-structure evolution under variable atmospheric conditions. In this paper, we analyze the influence of stream-wise fluctuating atmospheric flow conditions on wind turbines with large, flexible rotors through simulations of the National Rotor Testbed (NRT) turbine, located at Sandia National Labs’ Scaled Wind Farm Technology (SWiFT) facility in Lubbock, Texas. The Common Ordinary Differential Equation Framework (CODEF) modeling suite is used to simulate wind turbine aeroelastic oscillatory behavior and wind farm vortex–wake interactions for a range of conditions with spatially variant atmospheric flow. CODEF solutions for turbine operation in wind conditions featuring only one parameter fluctuation are compared to wind conditions with several wind parameter variations in combination. By isolating individual inflow variations and comparing them to multi-parameter scenarios, we determine the contributions of each atmospheric factor to rotor dynamics, wake evolution, and downstream wind farm interactions. The purpose of this paper is to analyze the effects of spatial variations in atmospheric flow on the topological evolution of wind turbine vortex wakes, which constitutes a gap in the current understanding of wind turbine wake dynamics. The insights gained from this study are particularly valuable for the development of wind farm control strategies aimed at mitigating the adverse effects of wake interactions, enhancing energy capture, and improving the overall stability of wind farm operations. With these insights, we aim to contribute to the development of modeling and simulation tools to optimize utility-scale wind power plants operating in diverse atmospheric environments.

Farrell, Alayna (ORCID:000000023555720X)↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application

This paper develops and compares two control schemes in the application control layer of a non-phase-locked loop (non-PLL) grid-forming (GFM) inverter to gain insight and understanding into how the two schemes affect the dynamic responses of GFM inverters and the transition operation of microgrids. The first scheme adopts power tracking based on an outer current loop in grid-connected mode and droop control in islanded mode, and the second uses droop control in both grid-connected and islanded modes. Analytical study is developed to compare the performance of these two strategies from various aspects, including fundamental differences, transition operation, power tracking, and P-Q capability with low point-of-common-coupling (PCC) voltages. Extensive simulation testing is carried out to validate the control performance of these two control strategies, and the simulation testing confirms the findings of the analytic study. Finally, the second strategy is recommended because of its superior control performance and ease of implementation. The analysis and results are useful in developing reliable control schemes for non-PLL GFM inverters because increasing numbers of inverters will work as non-PLL grid-forming sources in future grids because of their improved stability and reliability.

grid-forming↗

Role of Mg:Al ratio and Pt promotion on mitigating the deactivation of Ni-based methane steam reforming catalysts

Ni-based catalysts for CH 4 steam reforming require fine-tuning to withstand deactivation under dynamic operation conditions relevant to emerging H 2 -driven technologies. This study investigates the impact of the Mg:Al ratio and Pt presence in catalyst composition on the activity and stability of industrially relevant Ni-based mono- and bimetallic catalysts during simulated daily start-up and shut-down cycles in various gas atmospheres. The evolution of the catalyst structure during extensive testing procedures was investigated in detail by complementary electron microscopy, in situ/operando XAS and XRD. The results obtained revealed that catalyst deactivation is promoted at high Mg:Al ratios and especially affects the monometallic catalysts. By converting CH 4 at lower temperatures, Pt regulates the extent of Ni oxidation and its incorporation into MgO lattice. Further prevention of catalyst deactivation was achieved by optimizing the reactor shut-down procedure to minimize the simultaneous exposure to high temperatures and H 2 O vapors. By flushing the reactor with N 2 only around the reaction extinction temperature, a fraction of Ni species is maintained in metallic state, which is beneficial for the long-term activity and reaction operation economy.

54 ENVIRONMENTAL SCIENCES↗

A scalable superconducting nanowire memory array with row–column addressing

Scalable superconducting memory is required for the development of low-energy superconducting computers and fault-tolerant quantum computers. Conventional superconducting logic-based memory cells possess a large footprint that limits scaling; nanowire-based superconducting memory cells, although more compact, have high error rates, which hinders integration into large arrays. Here we report a 4 × 4 superconducting nanowire memory array that is designed for scalable row–column operations and has a functional density of 2.6 Mbit cm −2 . Each memory cell is based on a nanowire loop consisting of two temperature-dependent superconducting switches and a variable kinetic inductor. The arrays operate at 1.3 K, where we implement and characterize multiflux quanta state storage and destructive read-out. By optimizing the write- and read-pulse sequences, we minimize bit errors and maximize operating margins. We achieve a minimum bit error rate of 10 −5 . Here, we also use circuit-level simulations to understand the memory cell’s dynamics, performance limits and stability under varying pulse amplitudes.

Electrical and electronic engineering↗

A Multi-modal Approach to Understanding Degradation of Organic Photovoltaic Materials

State-of-the-art organic photovoltaic (OPV) materials are composed of complex, chemically diverse polymeric and molecular structures that form highly intricate solid-state interactions, collectively yielding exceptional tunability in performance and aesthetics. These properties are especially attractive for semitransparent power-generating windows or shades in living environments, greenhouses, or other architectural integrations. However, before such a future is realized, a broader and deeper understanding of property stability must be acquired. Stability during operating and environmental conditions is critical, namely, material color steadfastness, optoelectronic performance retention, morphological rigidity, and chemical robustness. To date, no single investigation encompasses all four distinct, yet interconnected, metrics. Here, we present a multimodal strategy that captures a dynamic and interconnected evolution of each property during the course of an accelerated photobleaching experiment. We demonstrate this approach across relevant length scales (from molecular to visual macroscale) using X-ray photoelectron spectroscopy, grazing-incidence X-ray scattering, microwave conductivity, and time-dependent photobleaching spectroscopies for two high-performance semitransparent OPV blends—PDPP4T:PC 60 BM and PDPP4T:IEICO-4F, with comparisons to the stabilities of the individual components. We present direct evidence that specific molecular acceptor (fullerene vs nonfullerene) designs and the resulting donor–acceptor interactions lead to distinctly different mechanistic routes that ultimately arrive at what is termed “OPV degradation.” We directly observe a chemical oxidation of the cyano endcaps of the IEICO-4F that coincides with a morphological change and large loss in photoconductivity while the fullerene acceptor-containing blend demonstrates a significantly greater fraction of oxygen uptake but retains 55% of the photoconductivity. Finally, this experimental roadmap provides meaningful guidance for future high-throughput, multimodal studies, benchmarking the sensitivity of the different analytical techniques for assessing stability in printable active layers, independent of complete device architectures.

14 SOLAR ENERGY↗

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

Dynamic Activation of Single-Atom Catalysts by Reaction Intermediates: Conversion of Formic Acid on Rh/Fe 3 O 4 (001)

The stability and activity of supported single-atom catalysts (SACs) represent critical yet opposing factors limiting our ability to explore and exploit their unique properties. Here, this study demonstrates the operation of a switchable catalyst that is activated in the presence of surface intermediates and reverts back to a stable but inactive form when the reaction is completed. We employ atomically defined Rh-Fe 3 O 4 (001) catalysts to demonstrate how structurally stable Rh, bound in surface octahedral Fe sites, gets destabilized to form highly active Rh adatoms and small clusters. Conversion of formic acid, leading initially to surface formate and hydroxyl species, is employed as a model reaction to probe the dynamics of such processes. We find that surface hydroxyl recombination to water through the Mars van Krevelen mechanism reduces Rh coordination, triggering its conversion to active Rh adatoms. Since such lattice oxygen exchange is observed in many acid-base and redox chemistries, the process can be broadly applicable to controlling the activation of the range of SACs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Affinity propagation clustering of full-field, high-spatial-dimensional measurements for robust output-only modal identification: A proof-of-concept study

Determination of the model order is a challenging problem in system identification, especially in output-only or operational modal identification where some modes are weakly excited. While existing methods such as the stabilization diagram method (spectral information) are effective, they do not scale to high-dimensional data, which is usually needed for high-fidelity characterization of structural dynamics and has been made available in the emerging full-field measurement techniques using optical methods such as photogrammetry and laser vibrometers. In this proof-of-concept study we present a new non-parametric, data-driven approach for robust output-only identification of high-spatial-dimensional modal parameters of basic structures by efficiently processing and interactively exploiting the full-field measurement (i.e., very dense spatial measurement points). Specifically, we first over-estimate the system model once, producing a pool of candidate modes associated with their modal frequencies and full-field, high-spatial-dimensional mode shapes. This is accomplished by a data-driven method termed affinity propagation clustering (APC), where the active clusters, which are the active modes in our formulations, emerge from the "message-passing" procedure and does not require a pre-determination of the cluster number (mode or model order). Next, rather than using the spectral information to distinguish the physical and spurious modes in the stabilization diagram method, we exploit and visualize the spatial, full-field mode shape associated with each candidate mode to do so. We conduct extensive experiments on basic structural models with comparisons to a few existing methods. The results indicate that the new method is computationally efficient for identifying high-spatial-dimensional modal parameters, and robust to identify weak modes by exploiting the full-field measurement. We also discuss its applicability and limitations for structures with complex geometry (shapes).

42 ENGINEERING↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Cyclic dynamics of misfires and partial burns in a dilute spark-ignition engine

Here, this study investigates the cyclic dynamics of cumulative heat release data past the edge of stability in a dilute spark-ignition engine. Emphasis is placed on analyzing the cyclic dynamics near the dilute limit where partial burns and misfires are frequent. These events are often followed by a higher-energy cycle due to the feed-forward mechanism present in the residual gases. These patterns are deterministic and increase the coefficient of variation to undesirable levels. Symbol sequence analysis was used to investigate the cyclic dynamics of these low–high patterns. The heat release was partitioned on an energy basis to give physical meaning to each partition and each sequence created when analyzing the symbol sequence results. This partitioning method provided insight into the differences in the dynamics when operating in the misfire or partial burn regime. These differences could impact the control method used.

42 ENGINEERING↗

Investigation of the Impact of Flow on MHD Perturbations with the NIMROD Code (Final Report)

This work will enable improved understanding of tokamak edge flows and impurity-species dynamics and their impact on MHD stability as it relates to ELMs, RMPs and QH-mode by leveraging computational developments of the NIMROD code. Experimentally, it is established that the tokamak flows and impurities species can have a substantial effect on MHD stability. This is particularly true for the edge plasma where, for example, large flow shear is correlated with the occurrence of the Quiescent H-mode (QH- mode) state as opposed to operation with edge localized modes (ELMs). Understanding plasma flows is challenging because of the many physical effects that come into play: particle orbits loss, neutrals dynamics, and interaction between multiple ion species with decoupled motion. We will develop a model that incorporates multiple ion species into the MHD framework that includes self-consistent magnetic-field evolution. With this model we will understand how the presence of impurities impacts the tokamak edge-pedestal flows. Finally, we will quantify the impact of the new multiple species modeling on 3D QH-mode simulations. This work will have broader impacts on all MHD studies when multiple species are present (as is the case in modern tokamaks), as well as contributing to the edge and transport communities who also are interested in the studies of multiple-ion-species flows in the edge pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical modeling of a proton spin-flipping system in the spin transparency mode at an integer spin resonance in JINR's Nuclotron

In this paper we propose a lattice insertion for the Nuclotron ring called a “spin navigator” that can adjust any direction of the proton polarization in the orbital plane using weak solenoids. The polarization control is realized in the spin transparency mode at the energy of 108 MeV, which corresponds to the integer spin resonance γ G = 2. The requirements on the navigator solenoid fields are specified considering the criteria for stability of the spin motion during any manipulation of the polarization direction in an experiment. Additionally, this paper presents the results of numerical modeling of the proton spin dynamics in the Nuclotron ring operated in the spin transparency mode. The verified spin navigator is aimed at an experimental study of a spin-flipping system using the Nuclotron ring. The results are relevant to the NICA (JINR), EIC (BNL) and COSY (FZJ) facilities where the spin transparency mode can be applied for polarization control.

47 OTHER INSTRUMENTATION↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

Study of microgrid resilience through co-simulation of power system dynamics and communication systems

The interdependence of power and communication systems in smart grid technologies is acknowledged, but difficult to quantify. Communication systems can be essential to maintaining stability in microgrids that are islanded due to extreme events. Though many power system studies assume the presence of communication networks, detailed modeling of power and communication systems for dynamic studies of microgrids is rare. The work presented in this paper develops a framework for power and communication system co-simulation to study the impact of communications system on microgrid stability. An operational use case is examined where a battery energy storage system operates to offset the loss of generation in an islanded microgrid. The framework is evaluated for different communication technologies, network structures, and communication media.

Thekkumparambath Mana, Priya↗

Intelligently Partitioned Phasor-EMT Hybrid Simulations of Large-Scale, High-IBR Power Systems

As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗