Search NASA⌕ Search

SEARCH · Search NASA

Results for “electromagnetic pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

PowderJet: Spherical metal powder production via multi-orifice droplet-on-demand metal jetting

Leading metal additive manufacturing techniques, such as laser powder bed fusion and directed energy deposition, rely on high-quality spherical metal powders. However, traditional powder production methods like gas atomization face limitations, including low in-spec yield, asphericity, and internal porosity. We introduce PowderJet, a powder production platform that uses electromagnetic pulses to eject liquid metal droplets from a multi-orifice nozzle. Unlike stochastic methods, PowderJet tightly controls powder size, distribution, and purity through a droplet-on-demand approach. We detail the system’s design, operation, and performance using a combined experimental and computational fluid dynamics (CFD) framework. Initial results with Al4008 and Cu110 alloys demonstrate successful production, yielding unsieved aluminum powder batches with a mean diameter of 200 µm and a narrow size distribution (15 µm standard deviation). The produced powders are highly spherical, achieving a roundness > 0.95. PowderJet operates with a small melt volume (3 mL) and supports continuous refilling, enabling production rates between 30 and 140 cm³/hr depending on jetting frequency, number of orifices and particle size. CFD simulations show that future systems could achieve rates exceeding 1000 cm³/hr for particle sizes as small as 40 µm. PowderJet’s high yield of in-spec powder makes it ideal for producing precious or hazardous materials that are inefficient to manufacture using conventional methods. This platform offers a scalable, precise, and efficient solution for producing high-quality powders tailored for advanced manufacturing applications.

Atomization↗

Particle‐In‐Cell Simulations of Starfish Prime

The Starfish Prime high altitude nuclear test created a transient diamagnetic cavity in the Earth's magnetic field above Johnston Island and launched an electromagnetic pulse (EMP) that was detected around the globe. For this work, we use the ion‐kinetic particle‐in‐cell code Topanga to simulate diamagnetic cavity evolution and the E3 EMP signal for Starfish Prime out to over a minute of physical time. The simulation domain has a longitudinal and latitudinal extent of 60° X 60° and a vertical extent of 2,000 km from the surface of the Earth. We compare our simulated results to magnetometer measurements taken in space and on the ground, finding good agreement in both cases. The diamagnetic cavity in the simulation forms in about a second, while the associated debris flux tube takes approximately 30 s to decay. The debris flux tube undergoes significant motion during this timeframe, rising upward. The measured E3 EMP signal on the ground consists of several components, all of which are present in our simulations. We discuss the physical origin of these components in relation to E3a (blast) and E3b (heave).

Belyaev, Mikhail A. [Lawrence Livermore National L↗

Topanga: A kinetic ion plasma code for large-scale ionospheric simulations on magnetohydrodynamic timescales

Topanga is a kinetic ion code developed for simulating large-scale plasma phenomena in the Earth's ionosphere on magnetohydrodynamic timescales. It is a domain-decomposed parallel code that runs on high-performance computing platforms. Features of Topanga include spherical geometry for simplified boundary conditions and computational efficiency; a hybrid plasma model with inertia-less fluid electrons, kinetic ions, and an electric field specified via an Ohm's law; a Maxwell-FDTD (finite difference time domain) plasma model which retains the displacement current in Maxwell's equations and models electron currents in the ionosphere with a tensor conductivity; sponge-layer boundary conditions for absorption of electromagnetic and plasma waves incident on the domain boundaries; and a novel mixed-implicit algorithm for evolving the EM fields inside the Maxwell-FDTD region that is stable over many orders of magnitude in the electron–ion collision frequency. We verify the numerical methods used in Topanga on a pair of test problems. The first test involves modeling a three-dimensional collisionless shock using the hybrid set of equations. The second test involves modeling a spherical TEM mode in vacuum using the Maxwell-FDTD set of equations. Finally, we demonstrate how using the combined set of hybrid and Maxwell-FDTD equations to model the Starfish Prime high-altitude nuclear test recovers a “missing” EM signal on the ground that is not present when using only the hybrid set of equations. The magnitude of this signal in the simulation containing the Maxwell-FDTD region agrees well with the E3a portion of the magnetohydrodynamic electromagnetic pulse from Starfish Prime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Computational prediction of dielectric breakdown strength of a transformer paper in oil with uncertainty quantification

The determination of the dielectric breakdown strengths of microstructurally heterogeneous materials has been a primarily experimental endeavor. We report the development of a microstructure-level model for computationally predicting the breakdown strength and analyzing the interactions between electromagnetic pulses (EMP) and the constituents in a composite of cellulose-based paper and mineral oil found in electrical transformers. The model allows explicit simulation of the material breakdown process by tracking the transition of dielectric constituents from non-conductive to conductive states. The focus is on the electric fields induced in the materials and the overall conditions for dielectric breakdown (defined as the onset of avalanche) caused by the electric field induced in the composite. Responses to three distinct pulse shapes, i.e., Steep Front (SF), Lightning (L), and AC with spectra spanning 60–9 × 105 Hz are considered. It is found that the breakdown strength of the material is significantly affected by microstructure heterogeneities, the spatial variations of the constituent properties, and the pulse shapes. A probabilistic characterization of the breakdown strength is computationally obtained and compared with experimental measurements. Although one particular material is analyzed, the model and approach are applicable to other heterogeneous materials as well.

breakdowns↗

Asteroids for μ Hz gravitational-wave detection

A major challenge for gravitational-wave (GW) detection in the μHz band is engineering a test mass (TM) with sufficiently low acceleration noise. We propose a GW detection concept using asteroids located in the inner Solar System as TMs. Our main purpose is to evaluate the acceleration noise of asteroids in the μHz band. We show that a wide variety of environmental perturbations are small enough to enable an appropriate class of ~10 km-diameter asteroids to be employed as TMs. This would allow a sensitive GW detector in the band (few) × 10 -7 Hz ≲ fGW ≲ (few) × 10 -5 Hz, reaching strain hc ~ 10 -19 around f GW ~10 μHz, sufficient to detect a wide variety of sources. To exploit these asteroid TMs, human-engineered base stations could be deployed on multiple asteroids, each equipped with an electromagnetic transmitter/receiver to permit measurement of variations in the distance between them. We discuss a potential conceptual design with two base stations, each with a space-qualified optical atomic clock measuring the round-trip electromagnetic pulse travel time via laser ranging. Trade space exists to optimize multiple aspects of this mission: for example, using a radio-ranging or interferometric link system instead of laser ranging. This motivates future dedicated technical design study. This mission concept holds exceptional promise for accessing this GW frequency band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Time reflection of light from a quantum perspective and vacuum entanglement

If a boundary between two static media is moving with a constant superluminal velocity, or there is a sudden change of the refractive index with time, this yields generation of entangled pairs of photons out of vacuum propagating in the opposite directions. Here we show that during this process, entanglement of Minkowski vacuum is transferred to the entanglement of the generated photon pairs. If initially an electromagnetic pulse is present in the medium the photon generation is stimulated into the pulse mode, and since photons are created as entangled pairs the counter-propagating photon partners produce a pulse moving in the opposite direction, which is known as time reflection. Thus, time reflection occurs due to stimulated generation of the entangled photon pairs out of entangled vacuum and no photons in the original pulse are in fact being reflected. This is different from the mechanism of light reflection from spatial inhomogeneities for which no photons are generated.

Optics↗

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Failure of Electrical Transformers due to Effects of a HEMP Event

Understanding the effect of a high-altitude electromagnetic pulse (HEMP) on the equipment in the United States electrical power grid is important to national security. A present challenge to this understanding is evaluating the vulnerability of transformers to a HEMP. Evaluating vulnerability by direct testing is cost-prohibitive, due to the wide variation in transformers, their high cost, and the large number of tests required to establish vulnerability with confidence. Alternatively, material and component testing can be performed to quantify a model for transformer failure, and the model can be used to assess vulnerability of a wide variety of transformers. This project develops a model of the probability of equipment failure due to effects of a HEMP. Potential failure modes are cataloged, and a model structure is presented which can be quantified by the results of small-scale coupon tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Substation Cable Layouts for EMP Coupling Analysis

Direct coupling of early-time high-altitude electromagnetic pulse (HEMP) to substation control cables is simulated for cable layouts based on surveys of seven electrical substations in the United States. An analytic transmission line modeling code is used to estimate worst-case coupled current at the terminations of cable segments in or near the control shack. Where applicable, an induced voltage due to cable shield grounding is also estimated. Various configurations are simulated, including cables with different elevations, lengths, radii, and terminations. Plots of the coupled HEMP effects are given, and general relationships between these effects and the substations geometric and material parameters are highlighted and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗