Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Computer modeling of current collection by the CHARGE-2 mother payload

The three-dimensional computer codes NASCAP/LEO and POLAR have been used to calculate current collection by the mother payload of the CHARGE-2 rocket under conditions of positive and negative potential up to several hundred volts. For negative bias (ion collection), the calculations lie about 25 percent above the data, indicating that the ions were less dense, colder, or heavier than the input parameters. For positive bias (electron collection), NASCAP/LEO and POLAR calculations show similar agreement with the measurements at the highest altitudes. This agreement indicates that the current is classically magnetically limited, even during electron beam emission. However, the calculated values fall well below the data at lower altitudes. It is suggested that beam-plasma-neutral interactions are responsible for the high values of collected current at altitudes below 240 km.

Mandell, M. J.↗

Effects of neutral gas release on current collection during the CHARGE-2 rocket experiment

Observations of current collection enhancements due to cold nitrogen gas control jet emissions from a highly charged rocket payload in the ionosphere are reported. These observations were made during the second cooperative high altitude rocket gun experiment (CHARGE-2) which was an electrically tethered mother/daughter payload system. The current collection enhancement was observed at the daughter payload located 100 to 400 m away from the mother which was firing an energetic electron beam. The authors interpret these results in terms of an electrical discharge forming in close proximity to the daughter during the short periods of gas emission. The results indicate that it is possible to enhance the electron current collection capability of positively charged vehicles by means of deliberate neutral gas releases into an otherwise undisturbed space plasma. These results can also be compared with recent laboratory observations of hollow cathode plasma contactors operating in the ignited mode. Experimental observations of current collection enhancements due to cold nitrogen gas control jet emissions from a highly charged, isolated daughter payload in the nighttime ionosphere were made. These observations were derived from the second cooperative high altitude rocket gun experiment (CHARGE-2) which was an electrically tethered mother-daughter payload system. The rocket flew from White Sands Missile Range (WSMR) in December, 1985. The rocket achieved an altitude of 261 km and carried a 1 keV electron beam emitting up to 48 mA of current (Myers, et al., 1989a). The mother payload, carried the electron beam source, while the daughter acted as a remote current collection and observation platform and reached a distance of 426 m away from the main payload. Gas emissions at the daughter were due to periodic thruster jet firings to maintain separation velocity between the two payloads.

Gilchrist, B. E.↗

Large area mapping of soil moisture using the ESTAR passive microwave radiometer

Investigations designed to study land surface hydrologic-atmospheric interactions, showing the potential of L band passive microwave radiometry for measuring surface soil moisture over large areas, are discussed. Satisfying the data needs of these investigations requires the ability to map large areas rapidly. With aircraft systems this means a need for more beam positions over a wider swath on each flightline. For satellite systems the essential problem is resolution. Both of these needs are currently being addressed through the development and verification of Electronically Scanned Thinned Array Radiometer (ESTAR) technology. The ESTAR L band radiometer was evaluated for soil moisture mapping applications in two studies. The first was conducted over the semiarid rangeland Walnut Gulch watershed located in south eastern Arizona (U.S.). The second was performed in the subhumid Little Washita watershed in south west Oklahoma (U.S.). Both tests showed that the ESTAR is capable of providing soil moisture with the same level of accuracy as existing systems.

Jackson, T. J.↗

Vlasov Simulation of Electrostatic Solitary Structures in Multi-Component Plasmas

Electrostatic solitary structures have been observed in the Earth's magnetosheath by the Cluster spacecraft. Recent theoretical work has suggested that these solitary structures are modeled by electron acoustic solitary waves existing in a four-component plasma system consisting of core electrons, two counter-streaming electron beams, and one species of background ions. In this paper, the excitation of electron acoustic waves and the formation of solitary structures are studied by means of a one-dimensional electrostatic Vlasov simulation. The present result first shows that either electron acoustic solitary waves with negative potential or electron phase-space holes with positive potential are excited in four-component plasma systems. However, these electrostatic solitary structures have longer duration times and higher wave amplitudes than the solitary structures observed in the magnetosheath. The result indicates that a high-speed and small free energy source may be needed as a fifth component. An additional simulation of a five-component plasma consisting of a stable four-component plasma and a weak electron beam shows the generation of small and fast electron phase-space holes by the bump-on-tail instability. The physical properties of the small and fast electron phase-space holes are very similar to those obtained by the previous theoretical analysis. The amplitude and duration time of solitary structures in the simulation are also in agreement with the Cluster observation.

magnetohydrodynamics (MHD)↗

Positive ions of the first- and second-row transition metal hydrides

Theoretical dissociation energies for the first- and second-row transition metal hydride positive ions are critically compared against recent experimental values obtained from ion beam reactive scattering methods. Theoretical spectroscopic parameters and dipole moments are presented for the ground and several low-lying excited states. The calculations employ large Gaussian basis sets and account for electron correlation using the single-reference single- and double-excitation configuration interaction and coupled-pair-functional methods. The Darwin and mass-velocity contributions to the relativistic energy are included in the all-electron calculations on the first-row systems using first-order perturbation theory, and in the second-row systems using the Hay and Wadt relativistic effective core potentials. The theoretical D(0) values for the second-row transition metal hydride positive ions should provide a critical measure of the experimental values, which are not as refined as many of those in the first transition row.

Pettersson, Lars G. M.↗

Visual perception of accelerated nitrogen nuclei interacting with the human retina.

Visual phenomena have now been observed in high-energy nitrogen beams produced at the Berkeley Bevatron. Using a nitrogen beam deflected at about 266 MeV/nucleon, three scientifically trained subjects made a series of observations. These observations confirm earlier hypotheses and argue for electronic excitation in or near the outer segments as the important mechanism. A picture showing a simplified anatomy of the left eye in horizontal section is presented. Three regions where various beam positions intercepted visual nervous structures are indicated.

Budinger, T. F.↗

The coherent Cerenkov radiated power from a group of field-aligned test particles in a magnetoplasma

An expression is derived that describes the coherent Cerenkov radiated power from a group of test particles in a plasma medium moving parallel to a magnetic field. In this analysis, each particle has an arbitrary position and velocity along a field line and, as a consequence, both the spatial and temporal coherence of the radiation are considered. As an example, it is demonstrated that a monoenergetic electron beam consisting of small pulses can generate wave powers well above incoherent levels if the pulse spacing is comparable to an integer number of emission wavelengths. It is also shown that, if the beam particles have a velocity spread, Delta-V, the wave powers will decrease in time due to the reduced temporal coherence of the particle radiators, where this coherence scales as 1/Delta-V. This latter effect applies to any charged particle beam propagating in a magnetoplasma, because even an initially monoenergetic beam becomes thermalized by electrostatic wave-particle interactions reducing the radiated power.

Farrell, W. M.↗

Scanning Light Sheet Would Measure Deflection Of Beam

Scanning-light-sheet apparatus designed to measure linear and angular displacement or deflection of structure. Intended specifically to measure deflection of beam-shaped truss structure. Includes conventional low-powered laser, lenses, mounts, single-axis optical scanner, several photodiodes, and electronic controller. Apparatus measures motion of structure and also used to determine positions, deflections, and velocities. Besides use in aerospace field, displacement measurements have many applications in construction-equipment and automotive industries.

Tcheng, Ping↗

Electron-beam-charged dielectrics: Internal charge distribution

Theoretical calculations of an electron transport model of the charging of dielectrics due to electron bombardment are compared to measurements of internal charge distributions. The emphasis is on the distribution of Teflon. The position of the charge centroid as a function of time is not monotonic. It first moves deeper into the material and then moves back near to the surface. In most time regimes of interest, the charge distribution is not unimodal, but instead has two peaks. The location of the centroid near saturation is a function of the incident current density. While the qualitative comparison of theory and experiment are reasonable, quantitative comparison shows discrepancies of as much as a factor of two.

Beers, B. L.↗

Heterogeneous Integration of Flipped Oxide Heterostructure Membranes for Nanoelectronics

Freestanding complex oxide membranes enable the release and transfer of epitaxial films, offering new design freedoms for next‐generation electronics. While the LaAlO 3 /SrTiO 3 (LAO/STO) heterostructure exhibits remarkable tunable conductivity at its interface, the active interface remains buried beneath the substrate, limiting access to this functionality. Here, we demonstrate how the LAO/STO heterostructure, in membrane form, can be flipped and precisely positioned on silicon and other platforms using polymer‐free micromanipulation. The transferred membranes preserve atomically smooth surfaces, high crystallinity, and key electronic properties. Through the 44‐nm insulating STO layer, ultra‐low‐voltage electron‐beam lithography (ULV‐EBL) writes conductive nanostructures at the now‐accessible STO/LAO interface, offering the potential to function as programmable local gates that modulate charge carriers in the underlying silicon. The platform establishes a general strategy for integrating complex oxide heterostructures with semiconductors, quantum materials, and flexible substrates, enabling new architectures for reprogrammable nanoelectronic devices.

36 MATERIALS SCIENCE↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

Filler-wire positioner for electron beam welding

Miniaturized positioner is installed in any electron beam vacuum chamber for use with wire feed applications requiring filler wire. Horizontal and vertical control of the positioner is maintained from a console while chamber is under vacuum. Device permits more positive positioning of welding filler wire.

Beaupre, W. M.↗

Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

Vonroos, O.↗

Reversal electron attachment ionizer for detection of trace species

An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of the electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

Bernius, Mark T.↗

Design of Amphoteric Refraction Models Using WAVICA and RAYICA

The phenomenon of refraction of light is due to refractive index mismatches in two different media. However, to achieve this effect, a finite reflection loss is inevitable. A recent finding presented a unique type of interface, ferroelastic materials, that enables refraction without any reflection for either an electron or a light beam. This property is called total refraction. The same type of interface that yields total refraction can also yield amphoteric refraction, where the index of refraction can be either positive or negative depending on the incident angle. This interface could potentially be used to steer light without reflections which could have major applications in high power optics. My goal this summer is to first familiarize myself with the Mathematica software, especially the Wavica and Rayica packages. I will then model the amphoteric refraction by either modifying the Wavica and Rayica packages or using the built-in functions in these packages.

Su, Richard↗

Digital optical recorder-reproducer system

A mass archival optical recording and reproduction system includes a recording light source such as a laser beam focussed and directed upon an acousto-optic linear modulator array (or page composer) that receives parallel blocks of data converted from a serial stream of digital data to be stored. The page composer imparts to the laser beam modulation representative of a plurality of parallel channels of data and through focussing optics downstream of the page composer parallel arrays of optical spots are recorded upon a suitable recording medium such as a photographic film floppy disc. The recording medium may be substantially frictionlessly and stably positioned for recording at a record/read station by an air-bearing platen arrangement which is preferably thermodynamically non-throttling so that the recording film may be positioned in the path of the information-carrying light beam in a static or dynamic mode. During readout, the page composer is bypassed and a readout light beam is focussed directly upon the recording medium containing an array of previously recorded digital spots, a sync bit, data positioning bits, and a tracking band. The readout beam which has been directed through the recording medium is then imaged upon a photodetector array, the output of which may be coupled to suitable electronic processing circuitry, such as a digital multiplexer, whereby the parallel spot array is converted back into the original serial data stream.

Reddersen, Brad R.↗

Reversal electron attachment ionizer for detection of trace species

An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of said electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

Bernius, Mark T.↗

Laboratory observations of ion cyclotron waves associated with a double layer in an inhomogeneous magnetic field

Observations of coherent electrostatic ion cyclotron (EIC) waves associated with a strong, magnetized double layer are presented. The double layers are produced in a weakly ionized argon plasma by applying a positive potential to an electrode plate located in the diverging magnetic field region of a cylindrical plasma column. Ionization within the electrode sheath is essential to the formation of these double layers. The resulting V-shaped potential structures have extended parallel, oblique and perpendicular (to B) electric field components. The frequency of the ion cyclotron instability is dependent upon the magnetic field strength at the position of the parallel potential structure. The properties of EIC waves in the presence of the double layer are discussed in relation to the possible excitation mechanisms (field-aligned currents, ion and electron beams, and perpendicular E fields).

Alport, M. J.↗