At least 145 records · Page 8

Accelerated Monte Carlo Simulation for Safety Analysis of the Advanced Airspace Concept

Safe separation of aircraft is a primary objective of any air traffic control system. An accelerated Monte Carlo approach was developed to assess the level of safety provided by a proposed next-generation air traffic control system. It combines features of fault tree and standard Monte Carlo methods. It runs more than one order of magnitude faster than the standard Monte Carlo method while providing risk estimates that only differ by about 10%. It also preserves component-level model fidelity that is difficult to maintain using the standard fault tree method. This balance of speed and fidelity allows sensitivity analysis to be completed in days instead of weeks or months with the standard Monte Carlo method. Results indicate that risk estimates are sensitive to transponder, pilot visual avoidance, and conflict detection failure probabilities.

Thipphavong, David↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stacking Variants and Superconductivity in the Bi-O-S System

High-temperature superconductivity has a range of applications from sensors to energy distribution. Recent reports of this phenomenon in compounds containing electronically active BiS 2 layers have the potential to open a new chapter in the field of superconductivity. Here we report the identification and basic properties of two new ternary Bi–O–S compounds, Bi 2 OS 2 and Bi 3 O 2 S 3 . The former is non-superconducting; the latter likely explains the superconductivity at T c = 4.5 K previously reported in “Bi 4 O 4 S 3 ”. The superconductivity of Bi 3 O 2 S 3 is found to be sensitive to the number of Bi 2 OS 2 -like stacking faults; fewer faults correlate with increases in the Meissner shielding fractions and T c . Elucidation of the electronic consequences of these stacking faults may be key to the understanding of electronic conductivity and superconductivity which occurs in a nominally valence-precise compound.

Phelan, W. Adam↗

Design and fabrication of prototype system for early warning of impending bearing failure

A test program was conducted with the objective of developing a method and equipment for on-line monitoring of installed ball bearings to detect deterioration or impending failure of the bearings. The program was directed at the spin-axis bearings of a control moment gyro. The bearings were tested at speeds of 6000 and 8000 rpm, thrust loads from 50 to 1000 pounds, with a wide range of lubrication conditions, with and without a simulated fatigue spall implanted in the inner race ball track. It was concluded that a bearing monitor system based on detection and analysis of modulations of a fault indicating bearing resonance frequency can provide a low threshold of sensitivity.

Meacher, J.↗

FAULT DIAGNOSIS WITH MULTI-STATE ALARMS IN A NUCLEAR POWER CONTROL SIMULATOR

This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effect of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. We used sensitivity and criterion based on Signal Detection Theory to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

99 GENERAL AND MISCELLANEOUS↗

Modeling of periodic great earthquakes on the San Andreas fault: Effects of nonlinear crustal rheology

We analyze the cycle of great earthquakes along the San Andreas fault with a finite element numerical model of deformation in a crust with a nonlinear viscoelastic rheology. The viscous component of deformation has an effective viscosity that depends exponentially on the inverse absolute temperature and nonlinearity on the shear stress; the elastic deformation is linear. Crustal thickness and temperature are constrained by seismic and heat flow data for California. The models are for anti plane strain in a 25-km-thick crustal layer having a very long, vertical strike-slip fault; the crustal block extends 250 km to either side of the fault. During the earthquake cycle that lasts 160 years, a constant plate velocity v(sub p)/2 = 17.5 mm yr is applied to the base of the crust and to the vertical end of the crustal block 250 km away from the fault. The upper half of the fault is locked during the interseismic period, while its lower half slips at the constant plate velocity. The locked part of the fault is moved abruptly 2.8 m every 160 years to simulate great earthquakes. The results are sensitive to crustal rheology. Models with quartzite-like rheology display profound transient stages in the velocity, displacement, and stress fields. The predicted transient zone extends about 3-4 times the crustal thickness on each side of the fault, significantly wider than the zone of deformation in elastic models. Models with diabase-like rheology behave similarly to elastic models and exhibit no transient stages. The model predictions are compared with geodetic observations of fault-parallel velocities in northern and central California and local rates of shear strain along the San Andreas fault. The observations are best fit by models which are 10-100 times less viscous than a quartzite-like rheology. Since the lower crust in California is composed of intermediate to mafic rocks, the present result suggests that the in situ viscosity of the crustal rock is orders of magnitude less the rock viscosity determined in the laboratory.

Reches, Ze'ev↗

Hydrologic windows into the crystalline basement and their controls on groundwater flow patterns across the Paradox Basin, western USA

Conceptual models of sedimentary basin groundwater flow systems typically assume that the crystalline basement acts as an impermeable boundary and can be neglected. In this study, we use hydrologic models constrained by isotopic and geochemical datasets to argue that the La Sal Mountains, Utah, USA, act as a hydrologic window into the Paradox Basin’s lower aquifer system and underlying crystalline basement. We conducted a sensitivity study in which we varied crystalline basement/laccolith permeability as well as fault zone connectivity along a cross-sectional transect from the La Sal Mountains to Lisbon Valley. When the crystalline basement/laccolith units are set at relatively permeable levels (10–14 m 2 ), simulated tracers that include total dissolved solids, oxygen isotopic composition of pore fluids (δ 18 O), and groundwater residence times are in closest agreement with field measurements. Model results indicate that pore fluids in the basal aquifer system underlying the Paradox Formation confining unit are a mixture of relatively young meteoric fluids and older Paradox Formation brines. The presence of faults did not significantly modify fluid exchange between the upper and lower aquifer systems. This was due, in part, to underpressuring within the Paradox Formation. Our study concludes that the Paradox Basin represents a regional recharge area for the Colorado Plateau, with groundwater discharge occurring along the Colorado River within the Grand Canyon some 375 km away to the southwest. This is only possible with a permeable crystalline basement. Our findings help explain the genesis of Mississippi Valley-type ore deposits of the US Midcontinent, where the presence of a permeable basement may be useful in addressing issues related to solute mass and energy balance.

54 ENVIRONMENTAL SCIENCES↗

Software testability and its application to avionic software

Randomly generated black-box testing is an established yet controversial method of estimating software reliability. Unfortunately, as software applications have required higher reliabilities, practical difficulties with black-box testing have become increasingly problematic. These practical problems are particularly acute in life-critical avionics software, where requirements of 10 exp -7 failures per hour of system reliability can translate into a probability of failure (POF) of perhaps 10 exp -9 or less for each individual execution of the software. This paper describes the application of one type of testability analysis called 'sensitivity analysis' to B-737 avionics software; one application of sensitivity analysis is to quantify whether software testing is capable of detecting faults in a particular program and thus whether we can be confident that a tested program is not hiding faults. We so 80 by finding the testabilities of the individual statements of the program, and then use those statement testabilities to find the testabilities of the functions and modules. For the B-737 system we analyzed, we were able to isolate those functions that are more prone to hide errors during system/reliability testing.

Voas, Jeffrey M.↗

Initial SEE Testing of Maestro

We have reported on initial SEE sensitivity of the full 49-core Maestro device. Supporting the low-level structures and qualitative system observation goals of phase 1 of testing. Observed sensitivities found to be consistent with Boeing predictions. Highlighted by the L1 data cache sensitivity which drives the rates on the current Maestro device. Presented details to the hardware and software setups that show where the limitations - highlighting future work. Key future work includes testing with memory and IO ports.

cache sensitivity↗

Electrical Engineering Medium Voltage Protection and Coordination

This presentation covers the basics of the medium voltage electrical system on the Kennedy Space Center. The material will include the process of selective coordination between protective devices and the analysis of a fault that occurred in the electrical system. I will discuss the most common causes of faults found and how the system reacts to the faults at different locations in the subsystem. Explain the importance of the sensitivity and coordination between the devices to protect the equipment it is supplying.

Wessner, Jason R.↗

Optical imaging of flavor order in flat band graphene

Abstract Spin- and valley flavor polarization plays a central role in the many-body physics of flat band graphene, with Fermi surface reconstruction — often accompanied by quantized anomalous Hall and superconducting state — observed in a variety of experimental systems. Here we describe an optical technique that sensitively and selectively detects flavor textures via the exciton response of a proximal transition metal dichalcogenide layer. Through a systematic study of rhombohedral and rotationally faulted graphene bilayers and trilayers, we show that when the semiconducting dichalcogenide is in direct contact with the graphene, the exciton response is most sensitive to the large momentum rearrangement of the Fermi surface, providing information that is distinct from and complementary to electrical compressibility measurements. The wide-field imaging capability of optical probes allows us to obtain spatial maps of flavor order with high throughput, and with broad temperature and device compatibility. Our work helps pave the way for optical probing and imaging of flavor orders in flat band graphene systems.

Science & Technology - Other Topics↗

Postseismic deformation due to subcrustal viscoelastic relaxation following dip-slip earthquakes

The deformation of the Earth following a dip-slip earthquake is calculated using a three layer rheological model and finite element techniques. The three layers are an elastic upper lithosphere, a standard linear solid lower lithosphere, and a Maxwell viscoelastic asthenosphere-a model previously analyzed in the strike-clip case (Cohen, 1981, 1982). Attention is focused on the magnitude of the postseismic subsidence and the width of the subsidence zone that can develop due to the viscoelastic response to coseismic reverse slip. Detailed analysis for a fault extending from the surface to 15 km with a 45 deg dip reveals that postseismic subsidence is sensitive to the depth to the asthenosphere but is only weakly dependent on lower lithosphere depth. The greatest subsidence occurs when the elastic lithosphere is about 30 km thick and the asthenosphere lies just below this layer (asthenosphere depth = 2 times the fault depth). The extremum in the subsidence pattern occurs at about 5 km from the surface trace of the fault and lies over the slip plane. In a typical case after a time t = 30 tau (tau = Maxwell time) following the earthquake the subsidence at this point is 60% of the coseismic uplift. Unlike the horizontal deformation following a strike slip earthquake, significant vertical deformation due to asthenosphere flow persists for many times tau and the magnitude of the vertical deformation is not necessarily enhanced by having a partially relaxing lower lithosphere.

Cohen, S. C.↗

Postseismic deformation due to subcrustal viscoelastic relaxation following dip-slip earthquakes

The deformation of the earth following a dip-slip earthquake is calculated using a three layer rheological model and finite element techniques. The three layers are an elastic upper lithosphere, a standard linear solid lower lithosphere, and a Maxwell viscoelastic asthenosphere - a model previously analyzed in the strike-clip case (Cohen, 1981, 1982). Attention is focused on the magnitude of the postseismic subsidence and the width of the subsidence zone that can develop due to the viscoelastic response to coseismic reverse slip. Detailed analysis for a fault extending from the surface to 15 km with a 45 deg dip reveals that postseismic subsidence is sensitive to the depth to the asthenosphere but is only weakly dependent on lower lithosphere depth. The greatest subsidence occurs when the elastic lithosphere is about 30 km thick and the asthenosphere lies just below this layer (asthenosphere depth = 2 times the fault depth). The extremum in the subsidence pattern occurs at about 5 km from the surface trace of the fault and lies over the slip plane. In a typical case after a time t = 30 tau (tau = Maxwell time) following the earthquake, the subsidence at this point is 60 percent of the coseismic uplift. Unlike the horizontal deformation following a strike slip earthquake, significant vertical deformation due to asthenosphere flow persists for many times tau and the magnitude of the vertical deformation is not necessarily enhanced by having a partially relaxing lower lithosphere. Previously announced in STAR as N83-13683

Cohen, S. C.↗

Application of Ensemble Kalman Filter in Power System State Tracking and Sensitivity

Ensemble Kalman Filter (EnKF) is proposed to track dynamic states of generators. The algorithm of EnKF and its application to generator state tracking are presented in detail. The accuracy and sensitivity of the method are analyzed with respect to initial state errors, measurement noise, unknown fault locations, time steps and parameter errors. It is demonstrated through simulation studies that even with some errors in the parameters, the developed EnKF can effectively track generator dynamic states using disturbance data.

dynamic state tracking↗

Numerical modeling of heterogeneous asperity distributions controlling the growth of shear rupture on a frictional fault

Copyright 2016 ARMA, American Rock Mechanics Association. A better understanding of the strength distributions and the seismic response of asperities failing within a cohesive (or breakdown) region of the growing shear rupture is important in many engineering disciplines, such as, hydraulic fracture and induced seismicity. In the laboratory, a fault is experimentally modeled by a 400 mm × 80 mm × 12 mm PMMA slider sheared across a large PMMA base plate. A pressure-sensitive film was employed to localize and size, and measure normal stress upon contact junctions. Moments prior to rapid sliding, multiple discrete and localized dynamic events (or foreshocks) were observed at a section of the fault that exhibited a sparse to dense transition in asperity distribution. Experiments showed that foreshocks occurred as the crack (rupture front) moved into the resistive patch of densely distributed asperities. We use the results of pressure sensitive film asperity measurements to develop a heterogeneous finite element (FE) model that studies the effect of asperities within the cohesive region have on the expanding shear crack. Slip accumulated heterogeneously during the loading cycle due to the non-uniform distribution of asperities. We study the constitutive behavior of a frictional interface where local slip is determined by the asperities and their ability to communicate elastically. A foreshock (Mw -7.4) was simulated in a quasi-static manner by instantaneoulsy removing an asperity contact during the loading cycle. The foreshock increased shear stress perturbations to neighboring regions up to distances of ~ 10 to 15 source radii.

Selvadurai, PA↗

Options for Upgrading Low-Voltage Spot Network Protection to Increase DER Interconnection Capacity

Existing standards and policies for interconnecting distributed energy resources (DERs) into low voltage spot networks severely limits the amount of DER installed on those networks to avoid negative impacts on protection systems. This report investigates options for upgrading the protection systems of spot networks to allow for additional DER installations beyond the normal limits (i.e., no reverse power flows allowed onto the MV system). Eight potential upgrade options are discussed that span various methods for new network protector algorithms, hardware upgrades, and the addition of communication. Each method has tradeoffs in terms of accuracy of detecting faults, requirements to upgrade equipment in the spot networks, need for communication, and sensitivity to false trips—all of which are explored in this report.