Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of MKIDs for CMB Observation at 220 GHz With the South Pole Telescope

We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_{i} = 4.8 \times 10^{5}$, aluminum inductor transition temperature $T_{c} = 1.19$K, and kinetic inductance fraction $\alpha _{k} = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $\eta \sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$for both detector orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Effect of stress and temperature on zero group velocity Lamb modes

Zero group velocity (ZGV) Lamb wave resonances are highly localized and sensitive to changes in material properties, making them a viable option for probing residual stresses and elastic nonlinearity through acoustoelastic effects. Temperature changes also influence ZGV modes and need to be accounted for, particularly when measuring the small frequency shifts associated with acoustoelastic effects. We use a laser-based ultrasonic system to measure the third-order elastic constants of several materials. A temperature compensation scheme is devised to remove the effects of temperature fluctuations from the measurements. Furthermore, the measured third-order elastic constants are used to predict the temperature dependence of the ZGV resonances using thermo-acoustoelasticity theory, and these predictions are compared to experimental measurements. We find that thermo-acoustoelasticity theory was unable to reliably predict the shift in ZGV resonances with temperature. These results could have important implications in understanding the limitations of thermo-acoustoelasticity theory and in developing precision ZGV resonance-based systems to detect and quantify residual stress in parts, a particularly relevant problem in additive manufacturing techniques including powder bed fusion and directed energy deposition.

Engineering↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HiFiPDV2 v. 2

SAND2024-01061O The HiFiPDV-2 software is similar to other photonic Doppler velocimetry (PDV) analysis codes in that it converts signals from intensity-time space to frequency-time space using a short-time Fourier transform (STFT). It then analyzes peaks of the resulting power spectral density information to extract the velocity-time history. The unique aspects of HiFiPDV and HiFiPDV-2 are that this reduction process is repeated for an array of reasonable STFT input variables. The resulting population distribution of output velocity-time histories is evaluated to determine the most likely velocity history and its associated uncertainty. This uncertainty is defined as the systematic uncertainty of the PDV signal as it is a function of input values to the reduction process. The HiFiPDV-2 program brings new functionality and efficiency to these calculations—most notably significant reductions in memory usage and calculation times, the ability to evaluate frequency-shifted signals, and the ability to filter out baseline signals. Developers recommend that users have at least 2 GB of RAM per CPU core in their system. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Voorhees, Travis↗

Raman gain control in optical fibers with orbital-angular-momentum-induced chirality of light

Stimulated Raman scattering is a particularly robust nonlinearity, occurring in virtually every material because its spectral linewidth and associated frequency shift do not typically depend on phases or directions (i.e. wavevectors) of the interacting light beams. In amorphous materials such as glass fibers, Raman bandwidths are large, enabling its use as a broadband gain element. This ubiquity makes it a versatile means for achieving optical amplification or realizing lasers over a large range of pulsewidths at user-defined colors. However, this ease of deploying the effect also presents itself as a stubborn source of noise in fiber-based quantum sources or parasitic emission in fiber lasers. Here, we show that orbital angular momentum carrying light beams experiencing spin-orbit interactions yield novel phase-matching criteria for Raman scattering. This enables tailoring its spectral shape (by over half the Raman shift in a given material) as well as strength (by ∼ 100×) simply by controlling light’s topological charge – a capability of utility across the multitude of applications where modulating Raman scattering is desired.

Liu, Xiao (ORCID:000000032239762X)↗

Multi-parameter distributed fiber optic sensing using double-Brillouin peak fiber in Brillouin optical time domain analysis

In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.

47 OTHER INSTRUMENTATION↗

Time-refraction near the critical angle and angular streaking with attosecond resolution [Invited]

We study the time-refraction of optical waves as they propagate through a time-varying slab and find the frequency shift associated with the abrupt change in the refractive index. We discover a geometrical mechanism responsible for an ultrafast blueshift followed by a redshift, occurring while the refractive index is increased monotonically. Furthermore, we find high sensitivity to incident angles near the traditional critical angle and unravel a new critical angle that varies in time. Finally, we introduce an innovative concept of a streak camera design that utilizes ultrafast nonlinearities in time-varying media and offers attosecond resolution capabilities.

Fruhling, Colton (ORCID:0000000282968802)↗

Utah FORGE: Well 16B(78)-32 DTS, RFS DSS Strain, and Absolute Strain Circulation Test Fiber Optic Data - August 2024

This dataset contains processed fiber optic measurements collected during the extended cross-well circulation test at the Utah FORGE site in August 2024. The data was acquired from the 16B(78)-32 well using distributed fiber optic sensing (DFOS) technology, including distributed temperature sensing (DTS) on multimode fiber and distributed strain sensing (DSS) measurements on single-mode fiber. The dataset includes Brillouin absolute strain, Rayleigh frequency shift (RFS) DSS strain change, RFS DSS strain change rate, and temperature (DTS) data, all stored in HDF5 format. Time coordinates are provided in UTC, and depth measurements are given in measured depth relative to the rotary kelly bushing (MD RKB) in feet. The spatial sampling on the RFS DSS strain data and the Brillouin Absolute Total Strain data is 20 cm and the spatial sampling on the DTS data is 1m. The dataset is accompanied by a report from Neubrex, which provides further documentation.

15 GEOTHERMAL ENERGY↗

Effects of Nonlinearities in Physics and Demography

Nonlinearities appear in almost all systems. Earlier, we focused on those in plasmas, ionospheric scattering, and the world population. As turned out, the estimate of the population growth made in 1974 is in astonishing agreement with the United Nations estimates and agrees with our present data to within 2%. Here, a particularly important role, both for the population evolution and wave interaction in plasmas, is played by non-Markovian effects (effects depending on the past time). For the population growth, this occurs due to a delay of one generation in the set of population limiting actions, while, for plasmas, it is caused by nonlinear frequency shifts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Integrated View of Hydraulic Induced Fracture Geometry in Hydraulic Fracture Test Site 2

Until relatively recently, most of our understanding about the geometry of hydraulically induced fractures in unconventional reservoirs has been inferred by patterns observed via microseismic monitoring. Important information, such as fracture-azimuth, fracture-length, height-growth and other geometric data has been determined from microseismic “event clouds”, which in turn has been used to interpret a stimulated reservoir volume (SRV). It is important to note that relatively limited microseismic results have been acquired in conjunction with other diagnostics and validated in a consistent manner. The Hydraulic Fracture Test Site 2 (HFTS2) in the Permian Delaware Basin provides a unique opportunity to compare the frac geometry interpretations derived from multiple frac diagnostic tools and at multiple scales. The integrated view that emerges from all the frac diagnostic tools is that in HFTS2 the geometries of hydraulically induced fractures are not random and with a highly complex branching architecture. In fact, the fracs are mostly vertical, parallel plana domains, and both vertically and horizontally asymmetrical. The hydraulically induced fractures have a very consistent azimuth with a strike that matches SHmax. At the distance corresponding to the spacing between nearby wells in HFTS2, ~ 660 ft, the pattern of strain interceptions observed from Low Frequency Distributed Acoustic Sensing (LF-DAS) shows far-field dimensions that are consistent with the stage length dimensions at the stimulated well. In general, larger stages with higher number of clusters create larger number of interceptions and wider stimulated intervals than that of shorter stages with the same cluster to cluster spacing and fewer clusters. The hydraulically induced fractures also show a clear tendency to preferentially grow upwards as shown by the microseismic data, by the relative lower number of LF-DAS interceptions in nearby deeper wells and finally by the observed LF-DAS strain patterns in the vertical observation well. In the near field, the geometries of the fracture domains are also consistent. As shown by the distributed strain measurements obtained during production via the monitoring of Rayleigh Frequency Shift (RFS), each cluster has a separate, non-overlapping, frac-zone-domain that are generally centered around the locations of each perforation cluster. Overall, the hydraulically induced fractures in HFTS2 are interpreted as occurring in swarms associated with individual clusters, each with its own unique geometry but with similar predictable geometric and propagation tendencies. The comprehensive frac diagnostic program in HFTS2, the well-pad layout that permits the investigation of the Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/1-21URTC/D011S018R003/2477511/urtec-2021-5396-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5396 2 impact that nearby producing wells has on frac geometry, together with an innovative Design of Experiment (DofE) that includes sequential-fracing, consistent cluster-to-cluster distances and few single-perforation cluster stages, has allowed us to gain a unique perspective about the geometry of the induced hydraulic fractures on this pad. Finally, the HFTS2 dataset has also provided us with a better understanding of the applicability and limitations of the different diagnostic tools.

58 GEOSCIENCES↗

High Dynamic Voltage Range Studies of Piezoelectric Multilayer Actuators at Low Temperatures

Piezo actuators are used for resonance control in superconducting linacs. In high accelerating gradients linacs, such as those operated in a pulsed mode, the piezos require a large operating voltage. This is due to the Lorentz forced detuning which causes a large frequency shift and is compensated with an active piezo-tuning system. In this high dynamic voltage range the piezo is expected to warm up drastically due to it being in an insulated vacuum. This study characterizes the dielectric properties (capacitance, dielectric losses), the piezo stroke (from geophone), and thermal properties such as heating. Results obtained in the temperature range of 20K to 300K will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Noise driven emittance growth with coherent forces

Noise driven emittance growth is modified by the presence of coherent forces. Closed form asymptotic growth rates are given for two frequency distributions. The analytic results are compared with tracking, showing good agreement. Purely numerical results for a parabolic frequency distribution are also presented. If a small antidamping force is present then additional, real frequency shifts increase growth rates.

43 PARTICLE ACCELERATORS↗

Development of self-sensing materials for extreme environments based on metamaterial concept and additive manufacturing

Structural health monitoring of an engineered component in a harsh environment is critical for multiple DOE missions including nuclear fuel cycle, subsurface energy production/storage, and energy conversion. Supported by a seeding Laboratory Directed Research & Development (LDRD) project, we have explored a new concept for structural health monitoring by introducing a self-sensing capability into structural components. The concept is based on two recent technological advances: metamaterials and additive manufacturing. A self-sensing capability can be engineered by embedding a metastructure, for example, a sheet of electromagnetic resonators, either metallic or dielectric, into a material component. This embedment can now be realized using 3-D printing. The precise geometry of the embedded metastructure determines how the material interacts with an incident electromagnetic wave. Any change in the structure of the material (e.g., straining, degradation, etc.) would inevitably perturbate the embedded metastructures or metasurface array and therefore alter the electromagnetic response of the material, thus resulting in a frequency shift of a reflection spectrum that can be detected passively and remotely. This new sensing approach eliminates complicated environmental shielding, in-situ power supply, and wire routing that are generally required by the existing active-circuit-based sensors. The work documented in this report has preliminarily demonstrated the feasibility of the proposed concept. The work has established the needed simulation tools and experimental capabilities for future studies.

36 MATERIALS SCIENCE↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

Modeling and Design of a Sub-Nyquist PDV Digitization System

Photon-Doppler Velocimetry (PDV) uses interferometry of a transmitted optical signal reflected from a fast-moving device under test (DUT) to generate a product signal at a doppler shifted frequency which is proportional to the velocity of the object being measured. The technique has applications in shock physics, where it is used to measure fast-moving objects over a short lifespan of travel, such as a bullet, shrapnel, or other shock accelerated object.

42 ENGINEERING↗

Multi-frequency General Relativistic Radiation-hydrodynamics with M 1 Closure

We report on recent upgrades to our general relativistic radiation-magnetohydrodynamics code, Cosmos++ , which expands the two-moment, M 1 , radiation treatment from gray to multi-frequency transport, including Doppler and gravitational frequency shifts. The solver accommodates either photon (Bose–Einstein) or neutrino (Fermi–Dirac) statistical distribution functions with absorption, emission, and elastic scattering processes. An implicit scheme is implemented to simultaneously solve the primitive inversion problem together with the radiation–matter coupling source terms, providing stability over a broad range of opacities and optical depths where the interaction terms can be stiff. We discuss our formulations and numerical methods, and validate our methods against a wide variety of test problems spanning optically thin to thick regimes in flat, weakly curved, and strongly curved spacetimes.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of Different Piezoelectric Material Stroke Displacement at Different Temperatures Using an SRF Cavity

Piezoelectric actuators are used for resonance control in superconducting linacs. The level of frequency compensation depends on the piezoelectric stroke displacement. In this study, the stroke displacement will be measured with a 1.3 GHz SRF cavity by measuring the frequency shift with respect to the voltage applied. The entire system was submerged in liquid helium. This study characterizes the PZT piezoelectric actuator (P-844K093) and a lithium niobate (P-844B0005) piezoelectric actuator. All these actuators were developed at Physik Instrumente (PI). The piezoelectric displacement was measured at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗