Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

144 records · Page 8

Spectroscopic classification, variability, and SED of the Fermi -detected CSS 3C 286: the radio-loudest NLS1 galaxy?

ABSTRACT 3C 286 is a well-known calibrator source in radio astronomy. It is also one of very few compact steep-spectrum (CSS) sources detected in γ-rays. Here, we perform a detailed spectroscopic and variability analysis and present the first quasi-simultaneous optical to X-ray spectral energy distribution (SED) in order to reveal physical mechanisms that dominate its emission at different wavelengths, and arrive at a reliable optical source classification. The first main result of our study reveals several pitfalls when applying simple broad- or narrow-line Seyfert 1 (BLS1 or NLS1) classification criteria that only look at the [O iii]–Hβ complex. [O iii] and Hβ can be dominated by the same outflow components, in which case full width at half-maximum (Hβ) is no reliable classification criterion, and extinction by intrinsic or intervening material can make the highest velocity Hβ component undetectable. After careful combination of all information from ultraviolet (UV)–optical spectra along with multiwavelength data, we confirm that 3C 286 can be classified as NLS1 galaxy, with line properties and supermassive black hole mass (of order 108 M⊙ and accreting near the Eddington limit) close to the BLS1 regime, making it an important borderline object. The quasi-simultaneous SED taken with Swift shows a sharp rise in the optical–UV, implying the presence of a strong accretion-disc component with extreme UV excess, consistent with emission-line diagnostics. Finally, we report the discovery of X-ray variability of 3C 286, plausibly dominated by jet emission, and variable by at least a factor of ∼4. This result suggests to exercise caution when using 3C 286 as radio calibrator in high-resolution radio very long baseline interferometry observations.

Yao, Su↗

A new method for measuring the 3D turbulent velocity dispersion of molecular clouds

ABSTRACT The structure and star formation activity of a molecular cloud are fundamentally linked to its internal turbulence. However, accurately measuring the turbulent velocity dispersion is challenging due to projection effects and observational limitations, such as telescope resolution, particularly for clouds that include non-turbulent motions, such as large-scale rotation. Here, we develop a new method to recover the 3D turbulent velocity dispersion (σv,3D) from position–position–velocity (PPV) data. We simulate a rotating, turbulent, collapsing molecular cloud, and compare its intrinsic σv,3D with three different measures of the velocity dispersion accessible in PPV space: (1) the spatial mean of the 2nd-moment map, σi, (2) the standard deviation of the gradient/rotation-corrected 1st-moment map, σ(c − grad), and (3) a combination of (1) and (2), called the ‘gradient-corrected parent velocity dispersion’, $\sigma _{\mathrm{(p}-\mathrm{grad)}}=(\sigma _{\mathrm{i}}^2+\sigma _{(\mathrm{c}-\mathrm{grad)}}^2)^{1/2}$. We show that the gradient correction is crucial in order to recover purely turbulent motions of the cloud, independent of the orientation of the cloud with respect to the line of sight. We find that with a suitable correction factor and appropriate filters applied to the moment maps, all three statistics can be used to recover σv,3D, with method 3 being the most robust and reliable. We determine the correction factor as a function of the telescope beam size for different levels of cloud rotation, and find that for a beam full width at half-maximum f and cloud radius R, the 3D turbulent velocity dispersion can best be recovered from the gradient-corrected parent velocity dispersion via $\sigma _{v,\mathrm{3D}}= \left[(-0.29\pm 0.26)\, f/R + 1.93 \pm 0.15\right] \sigma _{\mathrm{(p}-\mathrm{grad)}}$ for f/R < 1, independent of the level of cloud rotation or LOS orientation.

Stewart, Madeleine↗

Influence of Comptonization region over the ambiance of accretion disc in active galactic nucleus

ABSTRACT Understanding the radiative and physical structures of inner region of a few 100 pc of active galactic nucleus (AGNs) is important to constrain the causes of their activities. Although the X-ray emission from the Comptonization region/corona and the accretion disc regulates the broad-line emission regions and torus structures, the exact mutual dependency is not understood well. We performed correlation studies for X-ray, mid-infrared, and different components of Balmer emission lines for the selected sample of AGNs. Almost 10 different parameters and their interdependencies were explored in order to understand the underlying astrophysics. We found that the X-ray luminosity has a linear dependency on the various components of broad Balmer emission lines (e.g. L$_{\text{2-10 keV}}\, \propto$ L$^{0.78}_{\text{H}\beta ^{\text{B}}}$) and found a strong dependency on the optical continuum luminosity (L$_{\text{2-10 keV}}\, \propto$ L$^{0.86}_{5100\, \mathring{\rm A}}$). For a selected sample, we also observed a linear dependency between X-ray and mid-infrared luminosity (L$_{\text{2-10 keV}}\, \propto$ L$^{0.74}_{6\, \mu \text{m}}$). A break point was observed in our correlation studies for X-ray power-law index, Γ, and mass of black hole at ∼ log (M/M⊙) = 8.95. Similarly, the relations between Γ and full width at half-maximum (FWHM) of H α and H β broad components show breaks at FWHMH α = 7642 ± 657 km s−1 and FWHMH β = 7336 ± 650 km s−1. However, more data are required to confine the breaks locations exactly. We noted that Γ and Eddington ratios are negatively correlated to Balmer decrements in our selected sample. We analysed and discussed about the implications of new findings in terms of interaction AGN structures.

79 ASTRONOMY AND ASTROPHYSICS↗

Association of optical, ultraviolet, and soft X-ray excess emissions in AGNs

Soft X-ray emission (0.5–2.0 keV) plays a pivotal role in regulating the optical and ultraviolet (UV) emission in the active galactic nuclei (AGNs). We collected a sample of 1811 AGNs from the SDSS database and obtained various parameters of Balmer lines, optical continuum, Mg ii line & UV continuum and studied their dependencies on soft X-ray luminosity. Based on the linear regression analysis, we found that FWHM$_{\rm {Mg\,\,\small {II}}}$ ∝ FWHM$_{\text{H}\beta }^{0.554}$ suggesting that UV emission is arising from a region relatively outside the broad-line region (BLR) associated to the Hβ emission and found a strong correlation between optical and UV luminosities (L$_{\rm {Mg\,\,\small {II}}}$ ∝ $L_{\rm {H}\beta }^{0.822}$). It was noticed that the dependency of optical continuum luminosities on soft excess changes with the redshift (L X ∝ L$^{0.596}_{5100\, \mathring{\rm A}}$ for z < 0.5 and L X ∝ L$^{0.429}_{5100\, \mathring{\rm A}}$ for z > 0.5). The full width at half-maximum components of Hβ and Mg II core components were found to be virialized and is not affected by the soft excess emission whereas the wings of Mg II display a dependency. We estimated a relation viz. L X ∝L$^{0.520}_{3000\, \mathring{\rm A}}$ FWHM$^{0.525}_{\rm {Mg\,\,\small {II}}}$ and found to be well in agreement with a proposed physical scenario. All the derived relations were used to understand the intermodulating association of the BLR and disc in the AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IRIXS: a resonant inelastic X-ray scattering instrument dedicated to X-rays in the intermediate energy range

A new resonant inelastic X-ray scattering (RIXS) instrument has been constructed at beamline P01 of the PETRA III synchrotron. This instrument has been named IRIXS (intermediate X-ray energy RIXS) and is dedicated to X-rays in the tender-energy regime (2.5–3.5 keV). The range covers the L 2,3 absorption edges of many of the 4delements (Mo, Tc, Ru, Rh, Pd and Ag), offering a unique opportunity to study their low-energy magnetic and charge excitations. The IRIXS instrument is currently operating at the Ru L 3 -edge (2840 eV) but can be extended to the other 4d elements using the existing concept. The incoming photons are monochromated with a four-bounce Si(111) monochromator, while the energy analysis of the outgoing photons is performed by a diced spherical crystal analyzer featuring (10$\bar{2}$ lattice planes of quartz (SiO 2 ). A total resolution of 100 meV (full width at half-maximum) has been achieved at the Ru L 3 -edge, a number that is in excellent agreement with ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IRIXS Spectrograph: an ultra high-resolution spectrometer for tender RIXS

The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L 3 -edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538–544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al 2 O 3 (110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L 3 -edge, in excellent agreement with ray-tracing simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

Broadband laser output by application of stimulated rotational Raman scattering during high-intensity propagation of laser pulses with modified spectral profiles

Research at the Naval Research Laboratory pursues advanced laser technologies that can mitigate laser plasma instabilities (LPI) in applications such as inertial confinement fusion. Increased laser bandwidth is currently being developed as a strategy to suppress LPI. In particular, stimulated rotational Raman scattering (SRRS) has been demonstrated using the Nike krypton fluoride (KrF) laser facility as a viable method for enhancing bandwidth. The technique is applicable to other large laser facilities. Through a combination of high-intensity propagation and optimization of the laser spectrum in the low-energy stages of the laser, the output spectrum of Nike has been broadened with SRRS from its standard operating value of 1 THz full width at half-maximum (FWHM) bandwidth to span a range greater than 4.5 THz. This amount of bandwidth has been shown in simulations to be effective for mitigation of slow-growth laser plasma instabilities, such as cross-beam energy transport (CBET).

Optics↗

CHESS 2025: Spectrometer orthorectified at-sensor radiance from NEON AOP imaging spectroscopy surveys

This dataset provides Level 1 (L1) orthorectified at-sensor radiance derived from measurements collected by the Imaging Spectrometer-1 (NIS-1) onboard the NEON (National Ecological Observatory Network) Airborne Observation Platform (AOP) for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). NIS-1 captures light reflected from the Earth’s surface in 426 discrete wavelength bands as raw digital numbers (DNs; Level 0). These data are then calibrated to physical units (uW/cm²·sr·nm) following the processing steps described in the NEON Imaging Spectrometer Level 1B Calibrated Radiance Algorithm Theoretical Basis Document (ATBD; Gallery 2022). The data delivered here are the primary inputs for the surface reflectance product in “Custom surface reflectance, shade masks, and equivalent water thickness maps for the Colorado Headwaters Ecological Spectroscopy Study” (Carroll et al. 2026). For intertemporal comparison, the radiance data here are most directly relatable to the v2 radiance data in “NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset” (Goulden et al. 2018), to which the same processing methodology was applied. Together, the radiance and reflectance data enable users to exploit the unique reflection signatures of different surface objects for land cover classification, foliar trait mapping, plant vigor assessment, water content estimation, trace-element identification, and other scientific applications. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. Within each domain, data are delivered by flightline as orthorectified and calibrated hyperspectral rasters in Hierarchical Data Format version 5 (HDF5) format, with radiance values provided in uW/cm²·sr·nm on a fixed, uniform Universal Transverse Mercator (UTM) grid at 1 meter spatial resolution. The radiance rasters include all 426 NIS-1 spectral bands, along with associated quality-assurance (QA) and diagnostic and ancillary layers needed for atmospheric correction workflows. Orthorectified radiance is produced from pushbroom spectrometer observations by applying NEON’s radiometric calibration (including bad pixel masking, dark subtract, dark pedestal shift correction, electronic panel ghost correction, grating ghost correction, deblur correction and flat-fielding) and spectral calibration (using spectral response function band centers and full-width at half-maximum intensity), followed by geolocation and regridding to the fixed grid. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ∼75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the optical characterization of the 90 GHz telescope. Observations of the Moon establish the pointing while dedicated observations of Jupiter are used for beam calibration. The standard deviations of the pointing error in azimuth, elevation, and boresight angle are 1$^{'}_.$3, 2$^{'}_.$1, and 2$^{'}_.$0, respectively, over the first 3 yr of observations. This corresponds to a pointing uncertainty ∼7% of the beam’s full width at half-maximum (FWHM). The effective azimuthally symmetrized instrument 1D beam estimated at 90 GHz has an FWHM of 0$^°_.$620 ± 0$^°_.$003 and a solid angle of 138.7 ± 0.6(stats.) ± 1.1(sys.) μsr integrated to a radius of 4°. The corresponding beam window function drops to $b^2_ℓ$ = 0.93, 0.71, 0.14 at ℓ = 30, 100, 300, respectively. Far-sidelobes are studied using detector-centered intensity maps of the Moon and measured to be at a level of 10 −3 or below relative to the peak. The polarization angle of Tau A estimated from preliminary survey maps is 149°.6 ± 0°.2(stats.) in equatorial coordinates. The instrumental temperature-to-polarization (T → P) leakage fraction, inferred from per-detector demodulated Jupiter scan data, has a monopole component at the level of 1.7 × 10 −3 , a dipole component with an amplitude of 4.3 × 10 −3 , with no evidence of quadrupolar leakage.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies on magnetocaloric effect of Tb 2 Ni 0.90 Si 2.94 compound

A comparative study has been carried out on the magnetocaloric properties of as-cast and annealed Tb 2 Ni 0.90 Si 2.94 intermetallic compound. While the as-cast material exhibits ferromagnetic cluster-glass behaviour below 9.9 K coexisting with antiferromagnetic (AFM) interaction, the annealed system shows AFM ordering below 13.5 K and spin freezing occurs below 4 K. The compound exhibits moderate magnetocaloric performance with maximum isothermal entropy changes (–ΔS M ) 8.8 and 10.9 J kg –1 K –1 , relative cooling power (RCP) 306 and 365 J kg –1 , along with adiabatic temperature change (ΔT ad ) 5.5 and 8.15 K for 70 kOe magnetic field change in as-cast and annealed forms, respectively. The estimated magnetic entropy change is found to be larger for annealed sample in comparison to that of as-cast analogue. However, the full width at half maxima (FWHM) of –ΔS M (T) behaviour is larger in as-cast compound due to the presence of inherent structural disorder which reduces with thermal annealing. A positive isothermal entropy change (–ΔS M ) and adiabatic temperature change (ΔT ad ) is observed for the as-cast compound in the measured field and temperature region. In contrast, the annealed system exhibits inverse magnetocaloric effect in the low field and temperature region where AFM interactions dominate. Magnetocaloric effect (MCE) is used as a tool to establish a subtle correlation between the observed magnetocaloric effect and the reported magnetic properties of the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Double-Output CLL Resonant Converter for All-Electric UAV Applications

This paper presents a double-output resonant converter with high-frequency isolation for unmanned aerial vehicle (UAV) applications. The proposed topology is developed by using a full-bridge resonant inverter and double-output half-bridge active rectifiers. For the control system, a phase-shifted pulse width modulation (PS-PWM) method is utilized to adjusts the power flow among the output rectifiers in a wide voltage range regulation with a central control. The theoretical analysis of the converter is explored using the system model under different load conditions with constant frequency. The proposed system is validated with experimental results using 60 V input source and generating 0 - 100 V in each output at a full power of 500 W with 96% maximum efficiency in the laboratory experimental setup.

Asa, Erdem↗

The R -Process Alliance: Exploring the cosmic scatter among ten r -process sites with stellar abundances

Context. The astrophysical origin of the rapid neutron-capture process (r-process), responsible for producing roughly half of the elements heavier than iron, remains uncertain. Detailed chemical signatures from the oldest, most metal-poor stars, which act as fossil records of the earliest nucleosynthesis events, can be used to identify the dominant r-process sites. Aims. We present a homogeneous chemical abundance analysis of ten r-process element-enhanced stars. These old and metal-poor stars are strongly enriched in r-process elements with minimal contamination from other nucleosynthetic sources. By focusing on this chemically pure sample, we aim to investigate intrinsic variations in the r-process abundance patterns and explore their implications for the nature and potential diversity of r-process sites. Methods. We performed a detailed chemical abundance analysis of high-resolution, high-signal-to-noise spectra. For each star, we inspected over 1400 individual absorption lines using a combination of equivalent width measurements and spectral synthesis. The analysis was conducted under the assumption of 1D local thermodynamic equilibrium and employing the MOOG radiative transfer code. Results. We derived abundances for 54 chemical species, including 29 neutron-capture (n-capture) elements, covering the full mass range of the r-process abundance pattern. A kinematic analysis reveals that stars likely originated from ten kinematically distinct systems. Based on this assumption, we used the sample to probe the maximum variation expected from ten independent r-process nucleosynthesis events and computed the intrinsic dispersion of each element relative to Zr and Eu for the light and heavy r-process elements, respectively. This exercise resulted in a remarkably low cosmic scatter across the ten r-process sites enriching these stars; for the rare earth and third peak elements, for example, we find σ [La/Eu] = 0.08 and σ [Os/Eu] = 0.11 dex, while the scatter between light and heavy elements, σ [Zr/Eu] , is slightly higher at 0.18 dex. Conclusions. The elemental abundance patterns across the ten independent r-process sites show remarkably small cosmic dispersions. This minimal dispersion suggests a high degree of uniformity in r-process yields across diverse astrophysical environments.

Astronomy and AstroPhysics↗