Search NASA⌕ Search

SEARCH · Search NASA

Results for “high operating temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Strength stability at high temperatures for additively manufactured alumina forming austenitic alloy

Several fast-spectrum nuclear reactors designed to generate high power (~450 MWe) rely on forced convection of media such as supercritical CO 2 , sodium, or liquid lead to cool the nuclear core, operating at temperatures up to 600 °C. Cost-effective, high-strength Fe-based alumina forming austenitic (AFA) alloys are a promising candidate for the fabrication of critical nuclear components. This study investigated laser powder bed fusion (LPBF) processing of an AFA alloy composition optimized for improved creep resistance. Electron microscopy revealed an elongated grain structure along the build direction with a fine sub-grain cellular structure decorated with (Cr,Fe,Nb) 23 C 6 carbide precipitates at the intercellular boundaries. Finally, at temperatures of 20–900 °C, the LPBF alloy's superior tensile properties compared to its arc-melted counterpart and other advanced steels (e.g., SS316) were attributed to the distribution of nano-sized carbide precipitates, whereas the high ductility was attributed to the LPBF alloy's elongated grain structure.

36 MATERIALS SCIENCE↗

ULTIMATE Phase I project: Development of Niobium-based alloys for Turbine Applications

Current Ni-based alloys used in turbine blade applications are operating at 1100°C which is approximately 90% of the solidus of Ni-based alloys. Further increases in temperature can be achieved only through the use of alloys with higher solidus temperatures such as refractory alloys which include Mo, Nb, W, Ta alloys. Niobium has a unique combination of physical properties that include a high melting point (2468°C), lowest density (8.57 g/cc), and the lowest modulus amongst refractory alloys, a good thermal conductivity that increases from 45 W/mK at room temperature to 62 W/mK at 1093°C, good ductility with fabricability using traditional techniques, high strength, good creep resistance, and general chemical inactivity. Hence niobium alloys offer many advantages for use at the desired temperature of 1300°C. One of the major deterrents to the use of niobium and its alloys at high temperatures is achieving good oxidation resistance. In addition, achieving balanced properties of room temperature strength, ductility, fracture toughness, high temperature strength, and creep resistance required for 1300°C operation at a density of 9 g/cm 3 is extremely challenging since the addition of W which is a potent strengthener increases the density of the alloy. This project seeks to enable the development of a tri-layered turbine blade that can operate continuously at 1300°C with the core of the turbine blade providing good creep resistance, the second layer providing improved oxidation resistance over the core layer, and the third layer being an environmental barrier providing oxidation resistance. The objective of this Phase 1 project was to use computational modeling and advanced characterization tools to develop two classes of Nb alloys which could be used as the core layer and the transition layer. The first class of alloys developed in this project was a Nb-alloy designed to serve as the turbine blade core with excellent room temperature strength, ductility, and high temperature strength and creep resistance required for 1300°C operation. These alloys were designed to contain sufficient solute solution strengthening elements (W, Mo) but constrained by the density of alloy, along with the addition of elements such as Zr, Hf, Ta, C, and N to achieve a combination of primary and secondary carbide precipitation. A total of 38 “creep-resistant” alloys were designed and cast during the duration of the project. Processing techniques were developed to keep the oxygen contents as low as possible with typical oxygen contents less than 250 ppm. One alloy with a density of < 9.5 g/cc was successful in meeting the Phase 2 intermediate project mechanical property milestone requirements of room temperature ductility greater than 1.0%, 1200°C creep strain of less than 3% at 150 MPa and 100 hours in vacuum, and with solidus temperature greater than 1500ᵒC. The second class of alloys was designed to be a Nb-rich alloy with improved oxidation resistance when compared to the core layer and was designed specifically to be compatible with the core layer and the outer environmental barrier coating. This Nb- alloy will be specifically designed to be microstructurally stable at these temperatures when in contact with the core alloy and provide protection against catastrophic failure of the barrier coating. Two alloys were cast and processed but further development was discontinued to focus on the development of the creep resistant alloy.

36 MATERIALS SCIENCE↗

Molecular dynamics study of interstitial He clusters in nickel

This study presents a molecular dynamics analysis focusing on the behavior of interstitial helium (He) clusters in nickel (Ni), examining their formation, stability, and migration energetics. Consistent with previous research, we found that the binding energies of interstitial helium within a helium cluster are positive and increase with the cluster size, indicating a preference for helium atoms to cluster together. However, our findings also reveal that while the formation energy increases monotonically with cluster size, the increase in binding energy is non-monotonic. Importantly, small He clusters were observed to be thermally unstable at reactor operational temperatures (approximately 600 K), with the He 2 cluster exhibiting instability even at room temperature. With a binding energy of 0.49 eV for a He 4 cluster, we hypothesize that for helium bubbles to form via homogeneous nucleation (i.e., through trap mutation) at reactor operating temperatures, the helium concentration must be high enough to facilitate the formation of helium clusters of at least size 4 or larger. As expected, interstitial helium and small helium clusters are highly mobile. This mobility was observed not only at room temperature but also at temperatures as low as approximately 200 K. Furthermore, the mean squared displacement method has been utilized to determine the migration barriers and the corresponding prefactors for clusters ranging from He 1 to He 6

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of the AGR-5/6/7 UCO TRISO fuel irradiation test in the Advanced Test Reactor

AGR-5/6/7 was the last in a series of irradiation experiments sponsored by the U.S. Department of Energy in support of the development and qualification of TRISO coated particle fuel for use in a high-temperature gas-cooled reactor. This experiment was conducted to verify the performance of the reference-design TRISO-coated low-enriched UCO fuel for modular high-temperature gas-cooled reactor normal operating conditions and to explore fuel performance at temperatures substantially beyond those typical of normal operation. A total of 194 UCO fuel compacts in five capsules were irradiated in the Advanced Test Reactor for 360.9 effective full-power days, achieving final burnup ranging from 5.66% to 15.26% fissions per initial heavy metal atom and fast neutron fluence ranging from 1.62 × 10 25 to 5.55 × 10 25 n/m 2 (E > 0.18 MeV). Calculated time-averaged fuel temperatures ranged from 467 °C to 1432 °C, with a peak fuel temperature of 1536 °C. During the first five irradiation cycles (∼180 effective full-power days), 85m Kr fission gas release-rate-to-birth-rate ratios were 10 −7 –10 −6 , indicating no particle failures. Near the end of the sixth cycle, a substantial number of in-pile particle failures occurred in Capsule 1. The fission gas release from this capsule impacted the readings from the other four capsules and led to unreliable fission gas release measurements for all capsules during the last four cycles. A preliminary post-irradiation examination of Capsule 1 fuel and internal components revealed the in-pile particle failures resulted from operational issues with the capsule, not subpar performance of the fuel particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization

Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.

Chemiresistive gas sensors↗

Buffer-IPyC separation process in TRISO fuel particles simulated with Bison code

During High Temperature Gas-cooled Reactor (HTGR) operation, tristructural isotropic (TRISO) coated-particle fuel undergoes irradiation-induced changes in morphology and thermomechanical properties. Experimental results from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program show, among other things, the mechanism of gap formation between the buffer and inner pyrolytic carbon (IPyC) layers, which could be explored further via computational simulations using the Bison code. Two simulation models were developed, the debonding restricted model, where no gap formation between buffer and IPyC layers is permitted, and the debonding enabled model, where the gap between those layers is created. The inputs of the simulated models are based on the irradiation conditions from the AGR-1 experiment. The research included simulations on spherical and aspherical fuel types. Under the specific temperatures and fluences of the AGR-1 irradiation experiment, and the Bison simulations, it was concluded that the most common scenario is a gap formation along the buffer-IPyC interface, while the least possible scenario is the situation where there is no gap formation at the buffer-IPyC junction. The computational results confirmed that the sphericity of the fuel influences the thickness of the gap that occurs at the buffer-IPyC junction, in a way that with increasing aspect ratio the gap thickness increases. The results obtained for spherical and aspherical fuel are nearly identical. Finally, performed simulations match conclusions observed from the AGR-1 experiment, which as such shows that the Bison code is a good computational method for simulating the TRISO fuel. Future simulations will include the validation of performed research and comparison of the results between Bison and PARFUME codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FFTF HT9 Cladding Microstructure Characterization

The sodium-cooled fast reactor (SFR) is a promising candidate for next generation nuclear reactors, operating at extreme conditions which include high temperatures (>500?C core outlet temperature) and significant neutron damage. High-Cr martensitic HT9 steel is an excellent candidate for SFR cladding and duct material due to its compatibility with liquid sodium, good thermal conductivity, resistance to void swelling, and strong creep rupture strength [1-4].However, the harsh in-core environment of SFRs can cause complex microstructural changes and mechanical property degradation in HT-9. Ensuring the safe use of HT9 cladding for metallic fuel requires both a thorough understanding of its mechanical response to microstructure evolution as well as reliable microstructure-sensitive modeling predictions. Microstructure-sensitive modeling of high temperature creep behavior in HT9 cladding for SFR applications currently lack experimental data to model the phenomena accurately. To fill this need, methods to perform microstructural characterization have been developed and performed on HT9.

36 MATERIALS SCIENCE↗

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Development of Operando Atom Probe to study field-assisted surface chemistry

Recent efforts at PNNL have led to the development of in-situ Atom Probe Tomography (ISAPT) and Operando Atom Probe (OAP), establishing PNNL as a key player in this technology, both in the U.S. and globally. OAP has already pushed the initial limits of APT, which was traditionally used at cryo temperatures (<60 K) and ultra-high vacuum (<10⁻¹² bar), to operate in the presence of reactive gases (up to 10⁻¹⁰ bar) at a maximum temperature of 300 K. Using OAP, we successfully observed Co and Fe oxidation in real-time at the nanoscale, revealing the importance of surface structures in these interactions. Additionally, OAP opens the possibility to explore the influence of local electric fields (EFs) on surface chemistry and hydrogen interactions at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Directed Gas-Phase Formation of Azulene (C 10 H 8 ): Unraveling the Bottom-Up Chemistry of Saddle-Shaped Aromatics

The azulene (C 10 H 8 ) molecule, the simplest polycyclic aromatic hydrocarbon (PAH) carrying a fused seven- and five-membered ring, is regarded as a fundamental molecular building block of saddle-shaped carbonaceous nanostructures such as curved nanographenes in the interstellar medium. However, an understanding of the underlying gas-phase formation mechanisms of this nonbenzenoid 10π-Hückel aromatic molecule under low-temperature conditions is in its infancy. Here, by merging crossed molecular beam experiments with electronic structure calculations and molecular dynamics simulations, our investigations unravel an unconventional low-temperature, barrierless route to azulene via the reaction of the simplest organic radical, methylidyne (CH), with indene (C 9 H 8 ) through ring expansion. This reaction might represent the initial step toward to the formation of saddle-shaped PAHs with seven-membered ring moieties in hydrocarbon-rich cold molecular clouds such as the Taurus Molecular Cloud-1 (TMC-1). These findings challenge conventional wisdom that molecular mass growth processes to nonplanar PAHs, especially those containing seven-membered rings, operate only at elevated pressure and high-temperature conditions, thus affording a versatile low-temperature route to contorted aromatics in our galaxy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines (Final Report)

This is the final report for project DE-FE0031924 titled “High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines.” The report provides a summary of the entire project efforts from October 2020 through December 2024 including the high-temperature commercial dry gas seal (DGS) tests and thermal modeling of Task 2, as well as the high-temperature, large-diameter seal design and high-temperature tests of large-diameter seals in Task 3. A key outcome of Task 2 was the testing completion of specially instrumented commercial DGS in the GE-SwRI Apollo sCO 2 compressor (27,000 rpm). Test data from the DGS showed elevated temperatures upwards of 350 o F, which are close to the higher operating temperature limit of the DGS. The temperature measurements provide insight into the expected thermal loads on DGS operating in high-speed sCO 2 compressor and provided test data for validation of an in-house thermal model of the compressor/seal. Under Task 2.0, this report also presents the development of a steady-state conjugate heat-transfer model of the DGS operating in the sCO 2 compressor – a first of its kind model for modeling heat transfer of sCO 2 in an actual operating compressor. The findings of the thermal model show a reasonable match between temperature predictions of the model and the measured temperature data, also pointing out the validity of the approach and assumptions made in modeling the flows, heat transfer coefficients and windage modeling in the rig. Under Task 3.0, this report presents the preliminary design of a large-diameter hybrid face seal (14 inch and 26-inch diameter) for field testing in a land-based GE turbine. The preliminary seal design effort presented in this report under project DE-FE0031924 builds on the development and successful laboratory testing for such large diameter hybrid face seal under the prior DE-FE0024007 project. Key aspects of seal fluid analyses with CFD, mechanical design considerations and assembly considerations in a land-based turbine are presented. Finally, under Task 3.0, this report also presents the continued high-temperature testing of the 14-inch diameter hybrid face seal developed previously under the DE-FE0024007 program. Specifically, test data demonstrating successful non-contact seal operation and seal effective leakage of 0.001-inch with seal inlet temperatures above 700 o F are presented in this report. Successful hybrid seal operation in a laboratory environment for a large diameter (14-inch) seal at temperatures above 700 o F is a major technological milestone for this technology.

01 COAL, LIGNITE, AND PEAT↗

On High-Temperature Dynamometer Test Stand Development

RePED is a novel prototype alternator that has been designed and built to operate at 35 kW under 250 degrees C ambient temperature conditions. The operating efficiency will be measured using a 225-kW motor to drive the machine in a back-to-back configuration. The goal is to determine if the RePED alternator can deliver 35 kW at a rotational speed of 1,000 rpm while operating in 250 degrees C ambient temperature and have a minimum efficiency of 60%. Dynamometer testing of a high-temperature alternator for geothermal drilling presents several unique challenges, especially around maintaining and managing the various sources and types of energy passing through the system without impacting data quality. The objectives of this report are to (1) describe the test stand in detail, the relative orientation of each major component, and the data acquisition system and (2) discuss the behavior of the test stand components such that this report can serve as a reference document for future projects.

15 GEOTHERMAL ENERGY↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver (LTPCR)

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Novel PtNi single-atom–nanocluster (SA–NC) ensembles promote Tafel kinetics and ampere-class AEM hydrogen evolution

The development of efficient, durable, and low-PGM electrocatalysts for the hydrogen evolution reaction (HER) in alkaline media is critical for next-generation electrolysis technologies. We report a facile two-step synthesis of highly dispersed PtNi and PtNi-nitride nanoclusters (NCs) (~2.3 nm) with ultralow Pt content (0.5 at.%) anchored on N-doped Vulcan carbon. Structural and compositional characterization via XAS, XPS, HAADF-STEM, HRTEM, and EDS mapping established key structure–activity relationships across varying Pt/Ni ratios and pyrolysis temperatures. The Pt0.5Ni0.5/C-750 catalyst, an ensemble of PtNi M-N-C type single-atom (SA) moieties with neighboring PtNi nanoclusters (NC), exhibited superior HER performance in alkaline media, achieving overpotentials of 30, 115, and 210 mV at 10, 100, and 500 mA cm−2, respectively. Despite at a lower Pt content, this novel SA–NC ensemble outperformed commercial Pt/C by ~36%. A standardized literature comparison with contemporary Pt- and Ru-doped analogues reveals the as-prepared Pt0.5Ni0.5/C-750 to sit at the apex of Tafel-limited kinetics and low overpotential at 100 mA cm−2. Tafel-limited Tafel slopes in both alkaline and acidic regimes confirm favorable proton recombination kinetics. Mass activities at 200 mV reached 13.8 and 18.84 A mgPt−1 in alkaline and acidic media, respectively. However, excessive nitridation (e.g., at 650 °C) adversely altered Pt electronic structure and HER kinetics. While Ni enhanced alkaline HER, acidic HER favored Ni-free analogues. Pt0.5Ni0.5/C-750 also demonstrated robust temperature responsiveness and 300-h operational stability at high current densities (0.5–1.0 A cm−2) in MEA tests. This work presents a scalable strategy for designing thermally responsive, durable, and compositionally tunable NC catalysts with neighboring SA moieties for alkaline electrolysis.

AEMWE↗