Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High-precision monitoring of outgassing species in model extreme ultraviolet photoresists with a cavity ring-down spectrometer

Background Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. Aim Here, we focus on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. Approach The spectrometer’s enhanced laser path length (∼ 20 km) and broadband absorption capabilities in the C–H overtone region allow for sensitive and temporally resolved detection of mixtures of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and post-exposure bake (PEB) as well as storage under varying environmental conditions. Results Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Conclusions Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Extreme ultraviolet photoresists↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Transverse Single Spin Asymmetries of Heavy Flavor Electrons and Charged Pions in 200 GeV $p+p^{\uparrow}$ Collisions at Midrapidity

Transverse single spin asymmetries of particles produced in p+p^{\uparrow} p + p ↑ collisions provide insight on the partonic spin and momentum structure of hadrons; heavy flavor electrons provide access to initial state spin-momentum correlations of gluons in the proton, while charged pions provide access to initial and final state transverse spin effects. Charged particles are measured at midrapidity at PHENIX using the silicon vertex detector and central arm spectrometer, made of an electromagnetic calorimeter, a ring-imaging Cherenkov detector, and drift and pad chambers. Recent results for both electron and charged pion measurements from the 2015 running period will be presented.

Fitzgerald, Dillon↗

3D Printable Polymers for Radiological Applications

Additive manufacturing of polymers is a widely used and growing technology throughout the DOE complex. Composite filaments for Fused Deposition Modeling (FDM) printers are commonly used to enhance material properties such as mechanical strength, operating temperature and chemical resistance. Radio luminescent properties were added to 3D filaments by impregnating clear poly(ethylene terephthalate)-glycol (PETG) with X-ray scintillator powder. X-ray scintillators have unique, narrow emission spectra which can be imaged with low light DSLR cameras, photomultiplier tubes, or spectrometers. Filament Production: 1. Pellets are loaded into the hopper. 2. Temperature and extrusion speed are set on extruder. 3. Extruder turned on and filament is pulled from nozzle along air path to cool. 4. Spooler drive speeds set. 5. Filament is inserted through Filameasure then guided along drive wheels and into traverse. 6. Parameters adjusted to obtain 1.75 mm diameter 7. Filament is inserted into spooler wheel. Traverse speed set and slip nut adjusted to make tight and even roll. From Raw Materials to Printed Part: Clear PETG pellets were dipped in ZnS:Cu scintillator powder to coat pellets. Coated and uncoated pellets were mixed together before inserting into hopper. Filament showed trace amounts of powder and luminesced under UV light. Powder distribution is random and not reproducible thus providing a unique identification marker potentially useful for national security applications. Multiple X-ray scintillators can be arranged in a panel to discriminate incident X-ray photon energies. Variable panel arrangement: pixelated, layered, solid from homogenous filament. Ratio of emission intensities. Response varies with incident photon energy. Spectrally separate scintillators. Scintillators: Yttrium Oxide Europium Doped - Red, Gadolinium Oxysulfide Terbium Doped - Green, Barium Magnesium Aluminate Europium Doped - Blue, Zinc Sulfide Copper Doped - Green. Powder concentrations will need to be increased in the filament for use in the energy discriminating panel. Homogeneity in the filament will be a challenge that can be solved by turning the pellets into a powder and mixing it with scintillator powder prior to extrusion. The panels will be tested using x-ray booths and button sources such as Am-241, Cs-137, and Co-60.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photon energy-resolved velocity map imaging from spectral domain ghost imaging

Abstract We present an approach that combines photon spectrum correlation analysis with the reconstruction of three-dimensional momentum distribution from velocity map images in an efficient, single-step procedure. We demonstrate its efficacy with the results from the photoionization of the 2 p -shell of argon using the Free-electron LASer in Hamburg free-electron laser (FEL). Distinct spectral features due to the spin-orbit splitting of Ar + ( 2 p − 1 ) are resolved, despite the large average bandwidth of the ionizing pulses from the FEL. This demonstrates a clear advantage over the conventional analysis method, and it will be broadly beneficial for velocity map imaging experiments with FEL sources. The retrieved linewidth of the binding energy spectrum approaches the resolution limitation prescribed by the spectrometers used to collect the data. Our approach presents a path to extend spectral-domain ghost imaging to the case where the photoproduct observable is high-dimensional.

47 OTHER INSTRUMENTATION↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.

Penning trap mass spectrometry↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced material identification via momentum-integrated muon scattering tomography

Cosmic ray muons, originating from interactions in the upper atmosphere, possess high energy and unique penetrative capabilities suitable for non-traditional radiographic inspection. This study explores their application in various fields such as nuclear fuel cask monitoring, nuclear reactor imaging, and archaeology, leveraging the principle of multiple Coulomb scattering for imaging dense materials. While muon scattering tomography has shown promise, accurately measuring muon momentum remains challenging. This research introduces the Momentum Integrated Point-of-Closest Approach (mPoCA) algorithm, integrating muon momentum data into the traditional Point-of-Closest Approach (PoCA) framework. Utilizing the Cherenkov muon spectrometer, renowned for precise muon momentum estimation, the mPoCA algorithm offers a novel imaging approach. Simulations conducted with GEANT4 evaluate the mPoCA algorithm’s performance against the standard PoCA method, demonstrating superior image resolution and enhanced material identification capabilities, particularly in distinguishing materials like uranium and lead. These findings underscore the potential of the mPoCA algorithm for advancing muon scattering tomography applications.

36 MATERIALS SCIENCE↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

IRIXS Spectrograph: an ultra high-resolution spectrometer for tender RIXS

The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L 3 -edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538–544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al 2 O 3 (110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L 3 -edge, in excellent agreement with ray-tracing simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Agfa Structurix series D4 and D3sc x-ray films in the 0.7–4.6 keV energy range

X-ray films remain a key asset for high-resolution x-ray spectral imaging in high-energy-density experiments conducted at the National Ignition Facility (NIF). The soft x-ray Opacity Spectrometer (OpSpec) fielded at the NIF has an elliptically shaped crystal design that measures x rays in the 900–2100 eV range and currently uses an image plate as the detecting medium. However, Agfa D4 and D3sc x-ray films’ higher spatial resolution provides increased spectral resolution to the data over the IP-TR image plates, driving the desire for regular use of x-ray film as a detecting medium. The calibration of Agfa D4 x-ray film for use in the OpSpec is communicated here. These calibration efforts are vital to the accuracy of the NIF opacity measurements and are conducted in a previously un-studied x-ray energy range under a new film development protocol required by NIF. The absolute response of Agfa D4 x-ray film from 705 to 4620 eV has been measured using the Nevada National Security Site Manson x-ray source. A broader range of energies was selected to compare results with previously published data. The measurements were taken using selected anodes, filters, and applied voltages to produce well-defined energy lines.

Dutra, E. C. (ORCID:0000000167649195)↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning approaches to streamline and enhance the analysis of multiscale imaging data for bioaerosol and soil particles

Bioaerosol and soil particles are ubiquitous in the environment. They are multicomponent and complex in nature displaying mixed inorganic and organic components. The way components are mixed in a bioaerosol sample is referred to as its mixing state. Soil particles are also a mixture of inorganic (mineral) and organic (soil organic matter) components. Bioaerosol particles contribute to a major fraction of coarse mode atmospheric particles, especially in the tropical areas, contributing up to 80 % of the particle mass concentration. The mixing state of particles is crucial to evaluate because it impacts several important environmental processes such as warm and cold cloud formation and radiation budget. Mixing states in aerosols are accompanied by chemical reactions across solid-liquid-gas interfaces. In this study, we utilized elemental compositions and microcopy images of thousands of atmospheric particles acquired by computer-controlled scanning electron microscope equipped with an energy-dispersive x-ray spectrometer to compute the mixing state of atmospheric particles. A 2D convolutional neural network (CNN), also known as convnet, was used to model the relationship between low resolution imaging data and higher resolution spectroscopy data, with the former as training input and the latter as target output. Two types of CNNs were implemented and tested; a basic CNN and an Inception-v3 network. For binary classification, the basic CNN achieved an accuracy of 84.29 % across all atom types, and the Inception-v3-like network achieved an accuracy 85.51 %. This study demonstrates the applicability of deep learning to handle large amounts of imaging/chemical spectroscopy data efficiently and evaluate particle mixing state from a range of environmental samples.

54 ENVIRONMENTAL SCIENCES↗

Binding energies, charge radii, spins, and moments: Odd-odd Ag isotopes and discovery of a new isomer

We report on the masses and hyperfine structure of ground and isomeric states in 114,116,118,120 Ag isotopes, measured with the phase-imaging ion-cyclotron-resonance technique (PI-ICR) with the JYFLTRAP mass spectrometer and the collinear laser spectroscopy beamline at the Ion Guide Isotope Separator On-Line facility, Jyväskylä, Finland. We measured the masses and excitation energies, electromagnetic moments, and charge radii, and firmly established the nuclear spins of the long-lived states. A new isomer was discovered in 118 Ag and the half-lives of 118 Ag long-lived states were reevaluated. We unambiguously pinned down the level ordering of all long-lived states, placing the inversion of the 𝐼 = 0 − and 𝐼 = 4 + states at 𝐴 = 118 (𝑁 = 71). As a result, we compared the electromagnetic moments of each state to empirical single-particle moments to identify the dominant configuration where possible.

90 ≤ A ≤ 149↗

Sensitive photodetection below silicon bandgap using quinoid-capped organic semiconductors

High-sensitivity organic photodetectors (OPDs) with strong near-infrared (NIR) photoresponse have attracted enormous attention due to potential applications in emerging technologies. However, few organic semiconductors have been reported with photoelectric response beyond ~1.1 μm, the detection limit of silicon detectors. Here, we extend the absorption of organic small-molecule semiconductors to below silicon bandgap, and even to 0.77 eV, through introducing the newly designed quinoid-terminals with high Mulliken-electronegativity (5.62 eV). The fabricated photodiode-type NIR OPDs exhibit detectivity (D*) over 10 12 Jones in 0.41 to 1.2 μm under zero bias with a maximum of 2.9 × 10 12 Jones at 1.02 μm, which is the highest D* for reported OPDs in photovoltaic-mode with response spectra beyond 1.1 μm. The high D* in 0.9 to 1.2 μm is comparable to those of commercial InGaAs photodetectors, despite the detection limit of our OPDs is shorter than InGaAs (~1.7 μm). A spectrometer prototype with a wide measurable region (0.4 to 1.25 μm) and NIR imaging under 1.2-μm illumination are demonstrated successfully in OPDs.

36 MATERIALS SCIENCE↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.

42 ENGINEERING↗

Depth Thermography: Noninvasive 3D Temperature Profiling Using Infrared Thermal Emission

Here, we introduce a technique based on infrared thermal emission, termed depth thermography, that can remotely measure the temperature distribution beneath the surface of certain objects. Depth thermography utilizes the thermal-emission spectrum in the semitransparent spectral region of the target object to extract its temperature as a function of depth, in contrast with conventional thermography, which uses the spectrally integrated thermally emitted power to measure the surface temperature. Coupled with two-dimensional imaging, for example using an infrared hyperspectral camera or scanning a single-pixel spectrometer, this technique can yield volumetric temperature distributions. Furthermore, we carried out a proof-of-concept experiment on an asymmetrically heated fused-silica window, extracting the temperature distribution throughout the sample. Depth thermography may enable noncontact volumetric temperature measurements of microscopic objects such as multilayer electronic devices or macroscopic volumes of liquids and gases, as well as simultaneous all-optical measurements of optical and thermal properties of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗