SEARCH · Search NASA
Results for “interrupt”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Novel Model of Thyristor in Reverse Recovery Process for Current Interruption Test of HVDC Circuit Breakers
The high voltage thyristor is widely used in high voltage DC (HVDC) grids due to its large current capability. Recently, the high voltage thyristor is implemented to produce a high current in the HVDC circuit breaker (CB) testing process. Unfortunately, the reverse recovery process (RRP) of a thyristor could induce significant turn-off overvoltage and power losses, jeopardizing the safety of the devices. The existing models of a thyristor cannot describe such hard-switching transient accurately. Therefore, this paper divides this process into four stages based on the physical mechanism and proposes a novel cosine exponential (CE), simulating the voltage and current of the thyristor with analytical equations, which are derived from the equivalent circuit. Moreover, the extraction procedure of the proposed model is illustrated in this paper. Finally, we develop an HVDC CB test platform to validate the proposed model. Experimental results show that the proposed CE model can accurately predict the overvoltage with a relative error of less than 8% at various current varying rates.
Surge Current Interruption Capability of Discrete IGBT Devices in DC Hybrid Circuit Breakers
Not provided.
Quantifying Tortuosity of Porous Li-Ion Battery Electrodes: Comparing Polarization-Interrupt and Blocking-Electrolyte Methods
Not Available
Interruption Cost Estimate (ICE) Calculator v2.0
Explore the source record for details and available documents.
Automated 4D X-ray Computed Tomography Registration and Flaw Tracking Across Interrupted Creep Testing of Additively Manufactured Steel
Explore the source record for details and available documents.
Interrupted eruption of large quiescent filament associated with a halo CME
We analyze the observations of an eruptive quiescent filament associated with a halo Coronal Mass Ejection (CME). We use observations from the Atmospheric Imaging Assembly (AIA) instrument onboard the Solar Dynamics Observatory (SDO), Solar and Heliospheric Observatory (SOHO)/Large Angle and Spectrometric Coronagraph (LASCO), and the Solar Terrestrial Relations Observatory (STEREO A/B) satellites. The filament exhibits a slow-rise phase followed by a gradual acceleration and then completely disappears. The filament could be traced in STEREO observations up to an altitude of about 1.44 R{sub ⊙}, where its rise speed reached ∼14 km s{sup −1} and disappeared completely at about 10:32 UT on 2011 October 21. The CME associated with the filament eruption and two bright ribbons in the chromosphere both appeared at about 01:30 UT on October 22, i.e., 15 hr after the filament eruption was seen in He ii 304 Å filtergrams. We show that this delay is abnormally large even if the slow rise speed and slow acceleration of the filament are taken into account. To understand the cause of this delay, we compute the decay index (n) of the overlying coronal magnetic field. The height distribution of the decay index, n, suggests that the zone of instability (n > 1) at a lower altitude, 144–480 Mm, is followed by a zone of stability (n < 1) between 540 and 660 Mm. We interpret the observed delay to be due to the presence of the latter zone, i.e., the zone of stability, which could provide a second quasi-equilibrium state to the filament until it finally erupts.
Stellar Flybys Interrupting Planet–Planet Scattering Generates Oort Planets
Explore the source record for details and available documents.
Fatigue cracks detected and measured without test interruption
Ultrasonic flaw detector records cracks in materials undergoing fatigue tests, without interfering with test progress. The detector contains modified transducers clamped to the specimens, and an oscillograph readout.
Risk of mortality in interrupted exposure to 100 per cent 02 - role of air vs. lowered po2.
Effect of periods of air breathing during prolonged exposure to pure oxygen in mice
Interruption of proprioceptive sensory input - Mechanism for induction of ''cardiovascular deconditioning.''
Cardiovascular deconditioning caused by microcirculatory changes which reduce proprioceptor sensory input of unanesthetized rat
Replacement of fluid-filter elements without interruption of flow
Gatling-type filter assembly, preloaded with several filter elements enables filter replacement without breaking into the operative fluid system. When the filter element becomes contaminated, a unit inner subassembly is rotated 60 degrees to position a clean filter in the line.
Oxidation of Co-10 w/o Cr interrupted by vacuum annealing
Vacuum annealing treatments effect on oxidation rate of Co-Cr alloy at high temperatures
Reduction of computer power interruptions
Inexpensive latching relays incorporating one-second time delay prove effective for maintaining system power in place of computer facility automatic shutdown sensors that are activated by minute power surges or spikes in 60 Hz input signal.
Automatic circuit interrupter
In technique, voice circuits connecting crew's cabin to launch station through umbilical connector disconnect automatically unused, or deadened portion of circuits immediately after vehicle is launched, eliminating possibility that unused wiring interferes with voice communications inside vehicle or need for manual cutoff switch and its associated wiring. Technique is applied to other types of electrical actuation circuits, also launch of mapped vehicles, such as balloons, submarines, test sleds, and test chambers-all requiring assistance of ground crew.
Correlations of heat-transfer data and of friction data for interrupted plane fins staggered in successive rows
Explore the source record for details and available documents.