Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Novel Nanoionics-Based Switch for Microwave Applications

This paper reports the development and characterization of a novel switching device for use in microwave systems. The device utilizes a switching mechanism based on nanoionics, in which mobile ions within a solid electrolyte undergo an electrochemical process to form and remove a conductive metallic "bridge" to define the change of state. The nanoionics-based switch has demonstrated an insertion loss of approx.0.5dB, isolation of >30dB, low voltage operation (1V), low power (approx. micro-W) and low energy (approx. nJ) consumption, and excellent linearity up to 6 GHz. The switch requires fewer bias operations (due to non-volatile nature) and has a simple planar geometry allowing for novel device structures and easy integration into microwave power distribution circuits.

Nessel, James A.↗

Single-Event Gate Rupture in Power MOSFETs: A New Radiation Hardness Assurance Approach

Almost every space mission uses vertical power metal-semiconductor-oxide field-effect transistors (MOSFETs) in its power-supply circuitry. These devices can fail catastrophically due to single-event gate rupture (SEGR) when exposed to energetic heavy ions. To reduce SEGR failure risk, the off-state operating voltages of the devices are derated based upon radiation tests at heavy-ion accelerator facilities. Testing is very expensive. Even so, data from these tests provide only a limited guide to on-orbit performance. In this work, a device simulation-based method is developed to measure the response to strikes from heavy ions unavailable at accelerator facilities but posing potential risk on orbit. This work is the first to show that the present derating factor, which was established from non-radiation reliability concerns, is appropriate to reduce on-orbit SEGR failure risk when applied to data acquired from ions with appropriate penetration range. A second important outcome of this study is the demonstration of the capability and usefulness of this simulation technique for augmenting SEGR data from accelerator beam facilities. The mechanisms of SEGR are two-fold: the gate oxide is weakened by the passage of the ion through it, and the charge ionized along the ion track in the silicon transiently increases the oxide electric field. Most hardness assurance methodologies consider the latter mechanism only. This work demonstrates through experiment and simulation that the gate oxide response should not be neglected. In addition, the premise that the temporary weakening of the oxide due to the ion interaction with it, as opposed to due to the transient oxide field generated from within the silicon, is validated. Based upon these findings, a new approach to radiation hardness assurance for SEGR in power MOSFETs is defined to reduce SEGR risk in space flight projects. Finally, the potential impact of accumulated dose over the course of a space mission on SEGR susceptibility is explored. SEGR evaluation of gamma-irradiated power MOSFETs suggests a non-significant SEGR susceptibility enhancement due to accumulated dose from gamma rays. During SEGR testing, an unexpected enhanced dose effect from heavy-ion irradiation was detected. We demonstrate that this effect could be due to direct ionization by two or more ions at the same channel location. The probability on-orbit for such an occurrence is near-zero given the low heavy-ion fluence over a typical mission lifetime, and did not affect SEGR susceptibility. The results of this work can be used to bound the risk of SEGR in power MOSFETs considered for insertion into spacecraft and instruments.

Lauenstein, Jean-Marie↗

Structure, Function, Self-Assembly and Origin of Simple Membrane Proteins

Integral membrane proteins perform such essential cellular functions as transport of ions, nutrients and waste products across cell walls, transduction of environmental signals, regulation of cell fusion, recognition of other cells, energy capture and its conversion into high-energy compounds. In fact, 30-40% of genes in modem organisms codes for membrane proteins. Although contemporary membrane proteins or their functional assemblies can be quite complex, their transmembrane fragments are usually remarkably simple. The most common structural motif for these fragments is a bundle of alpha-helices, but occasionally it could be a beta-barrel. In a series of molecular dynamics computer simulations we investigated self-organizing properties of simple membrane proteins based on these structural motifs. Specifically, we studied folding and insertion into membranes of short, nonpolar or amphiphatic peptides. We also investigated glycophorin A, a peptide that forms sequence-specific dimers, and a transmembrane aggregate of four identical alpha-helices that forms an efficient and selective voltage-gated proton channel was investigated. Many peptides are attracted to water-membrane interfaces. Once at the interface, nonpolar peptides spontaneously fold to a-helices. Whenever the sequence permits, peptides that contain both polar and nonpolar amino also adopt helical structures, in which polar and nonpolar amino acid side chains are immersed in water and membrane, respectively. Specific identity of side chains is less important. Helical peptides at the interface could insert into the membrane and adopt a transmembrane conformation. However, insertion of a single helix is unfavorable because polar groups in the peptide become completely dehydrated upon insertion. The unfavorable free energy of insertion can be regained by spontaneous association of peptides in the membrane. The first step in this process is the formation of dimers, although the most common are aggregates of 4-7 helices. The helices could arrange themselves such that they formed pores capable of transporting ions and small molecules across membranes. Stability of transmembrane aggregates of simple proteins is often only marginal and, therefore, it can be regulated by environmental signals or small sequence modifications in the region of interhelical interactions. A key step in the earliest evolution of membrane proteins was the emergence of selectivity for specific substrates. Many channels could become selective if one or only a few properly chosen amino acids are properly placed along the channel, acting as filters or gates. This is a convenient evolutionary solution because it does not require imposing conditions on the whole sequence.

Pohorille, Andrew↗

All-Atom Modeling and Simulation of Biopolymer Interface: Dual Role of Antifouling Polymer Brushes

Antifouling polymer brushes are well-known for their exceptional resistance to unwanted protein adsorption. While experimental studies have extensively characterized protein–polymer brush interactions, computational investigations remain limited, largely due to the challenges in accurately modeling and integrating these complex, multicomponent systems without resorting to oversimplification. To address this challenge, this study presents one of the most comprehensive and realistic model systems to date, comprising the substrate, grafted polymers, and proteins. Our work interprets the interactions between polymer brush and protein based on realistic modeling without simplification. In particular, this study utilizes molecular modeling and simulation of polycationic and polyzwitterionic brushes─poly(dimethylaminoethyl methacrylate) (PDMAEMA), poly(2-(N-oxide-N,N-dimethylamino)ethyl methacrylate) (PNOMA), and poly(2-(N-3-sulfopropyl-N,N-dimethylammonium)ethyl methacrylate) (PSBMA)─grafted onto α-quartz substrates via polymerization initiator linkers. The brush models were developed to closely replicate experimentally synthesized samples and to provide detailed insights into structural and dynamical changes at the molecular level during protein adsorption. Using steered molecular dynamics simulations, we show that the PSBMA brush, due to its high local density, exhibits the greatest resistance to protein insertion. Cα root-mean-square deviation and interaction pattern analyses further reveal that the PSBMA brush also induces the most significant destabilization of lysozyme, while the PDMAEMA brush enhances protein stability through ion-mediated interactions. The PNOMA brush, while requiring the lowest force for protein adsorption, induces greater protein destabilization than the PDMAEMA brush, primarily due to electrostatic repulsion caused by a short carbon spacer length. Hydration analysis reveals that both the PSBMA brush and the lysozyme interacting with it exhibit the most rapid dehydration, attributed to the brush’s high local chain density, which results in the greatest lysozyme destabilization and the highest adsorption force. These findings highlight the dual role of antifouling polymer brushes: resisting protein adsorption and modulating protein structural dynamics. In conclusion, this study provides valuable insights for the rational design of next-generation antifouling materials and offers a framework for realistic model development in complex multicomponent systems.

Adsorption↗

Carbohydrate Deacetylase Unique to Gut Microbe Bacteroides Reveals Atypical Structure

Bacteroides are often the most abundant, commensal species in the gut microbiome of industrialized human populations. One of the most commonly detected species is Bacteroides ovatus. It has been linked to benefits like the suppression of intestinal inflammation but is also correlated with some autoimmune disorders, for example irritable bowel disorder (IBD). Bacterial cell surface carbohydrates, like capsular polysaccharides (CPS), may play a role in modulating these varied host interactions. Recent studies have begun to explore the diversity of CPS loci in Bacteroides; however, there is still much unknown. Here, we present structural and functional characterization of a putative polysaccharide deacetylase from Bacteroides ovatus (BoPDA) encoded in a CPS biosynthetic locus. We solved four high resolution crystal structures (1.36-1.56 Å) of the enzyme bound to divalent cations Co 2+ , Ni 2+ , Cu 2+ , or Zn 2+ and performed carbohydrate binding and deacetylase activity assays. Structural analysis of BoPDA revealed an atypical domain architecture that is unique to this enzyme, with a carbohydrate esterase 4 (CE4) superfamily catalytic domain inserted into a carbohydrate binding module (CBM). Additionally, BoPDA lacks the canonical CE4 His-His-Asp metal binding motif and our structures show it utilizes a noncanonical His-Asp dyad to bind metal ions. BoPDA is the first protein involved in CPS biosynthesis from B. ovatus to be characterized, furthering our understanding of significant biosynthetic processes in this medically relevant gut microbe.

59 BASIC BIOLOGICAL SCIENCES↗

Method of making dished ion thruster grids

A pair of flat grid blanks are clamped together at their edges with an impervious metal sheet on top. All of the blanks and sheets are dished simultaneously by forcing fluid to inflate an elastic sheet which contacts the bottom grid blank. A second impervious metal sheet is inserted between the two grid blanks if the grids have high percentage open areas. The dished grids are stress relieved simultaneously.

Banks, B. A.↗

An Atom-Precise Approach to Damp First-Order Phase Transitions and Its Implications for Neuromorphic Signal Processing

Neuromorphic computing inspired by mammalian intelligence aims to emulate the nonlinear dynamics of biological neurons and synapses to achieve fast, low-energy, and highly efficient information processing. Brain-inspired computing relies on the design and discovery of materials exhibiting nonlinear current–voltage profiles, frequently underpinned by electronic state transitions, to achieve spiking neurons and dynamically tunable synapses. A signature challenge in the design of artificial neurons is controlling the steepness of first-order transitions in active elements, as abrupt transitions are at risk of driving unstable voltage and temperature oscillations, which result in catastrophic device failure. A critical knowledge gap is the lack of structure–function correlations mapping the composition and atomistic structure of crystalline solids to nonlinear dynamical response characteristics. Here, we address the key question of how modification of atomistic structure correlates with alteration of neuron-like functionality. Constructing oscillator circuits from millimeter-scale single crystals enables high-resolution atomic structure solutions, which we use to demonstrate that the selective positioning of Pb cations modifies charge ordering along a one-dimensional CuxV2O5 framework even at low insertion stoichiometries, thereby providing an atom-precise design parameter for damping first-order transitions. We use temperature-variant X-ray diffraction and X-ray spectroscopy to elucidate the suppression of Cu-ion shuttling based on the precise positioning of Pb ions in seven-coordinated tunnel interstitial sites as the mechanistic basis for transition broadening, thus bridging a critical gap between statistical mechanics and quantum chemical descriptions of phase transitions. Such mechanistic understanding thus paves the way to site-selective modification strategies for modulating the sharpness of first-order transitions, with an exemplary demonstration here in tuning neuronal signal processing.

Crystal structure↗

Cycle life testing of 8-cm mercury ion thruster cathodes

Two main cathodes have successfully completed 2800 and 1980 cycles and three neutralizers, 3928, 3050, and 2850 cycles in ongoing cycle life tests of flight-type cathode-isolator-vaporizer and neutralizer-isolator-vaporizer assemblies for the 4.45 mN 8-cm Hg ion thruster system. Each cycle included one hour of cathode operation. Starting and operating conditions simulated those expected in a typical auxiliary propulsion mission duty cycle. The cycle life test results are presented along with results of an insert comparison test which led to the selection of a rolled foil insert type for the 8-cm Engineering Model Thruster cathodes.

Wintucky, E. G.↗

Laboratory studies of polyoxymethylene - Application to comets

Formaldehyde polymer mass spectra gathered by means of the particle beam and direct insertion probe system indicate that these substances can evaporate at 300 K and yield gas-phase polyoxymethylene glycols in the presence of water. These experimental results are presently used to ascertain the likely origin of the polymeric ions that have been observed with the Giotto mission's PICCA instrument. The experimental results are held to be in keeping with the hypothesized presence of formaldehyde polymers in comets.

Moller, Gregory↗

Cycle life testing of 8-cm mercury ion thruster cathodes

Two main cathodes have successfully completed 2800 and 1980 cycles and three neutralizers, 3928, 3050, and 2850 cycles in ongoing cycle life tests of flight-type cathode-isolator-vaporizer and neutralizer-isolator-vaporizer assemblies for the 4.45 mN 8-cm Hg ion thruster system. Each cycle included one hour of cathode operation. Starting and operating conditions simulated those expected in a typical auxiliary propulsion mission duty cycle. This paper presents the cycle life test results and also results of an insert comparison test which led to the selection of a rolled foil insert type for the 8-cm Engineering Model Thruster cathodes.

Wintucky, E. G.↗

Carbon Shields for Intercalated Fiber Conductors

Stability in air increased by depositing amorphous carbon. Initially graphite fibers intercalated (insertion of atoms or molecules between graphite layers). Next, conductor coated with diamondlike amorphous carbon. Coating applied in same chamber as intercalation reaction or alternate deposichamber is used. Deposition of carbon accomplished by any number of techniques. tion Ion-beam sputter-deposition and RF plasma techniques have been used, but dc plasma and others work also. Potential uses include conductive epoxy composites, tether conductors, signal wire, and power cables.

Banks, B. A.↗

InGaAs/GaAs multiquantum-well electroabsorption modulator with integrated waveguide

A monolithically integrated guided-wave modulator has been realized by using molecular-beam epitaxial regrowth and ion-milling techniques. The guiding and modulating regions consist, respectively, of In-doped GaAs and GaAs/In(0.34)Ga(0.66)As strained-layer multiquantum wells. Modulation is achieved by field-enhanced electroabsorption in the multiquantum wells. The insertion loss of the modulator is 0.9 dB, and the transmission loss in the guides is less than or equal to 1 dB/cm. The temporal response of similar GaAs/InGaAs as-grown photodiodes to pulsed laser excitation is characterized by a rise time of 115 psec.

Das, Utpal↗

Minor groove RNA triplex in the crystal structure of a ribosomal frameshifting viral pseudoknot

Many viruses regulate translation of polycistronic mRNA using a -1 ribosomal frameshift induced by an RNA pseudoknot. A pseudoknot has two stems that form a quasi-continuous helix and two connecting loops. A 1.6 A crystal structure of the beet western yellow virus (BWYV) pseudoknot reveals rotation and a bend at the junction of the two stems. A loop base is inserted in the major groove of one stem with quadruple-base interactions. The second loop forms a new minor-groove triplex motif with the other stem, involving 2'-OH and triple-base interactions, as well as sodium ion coordination. Overall, the number of hydrogen bonds stabilizing the tertiary interactions exceeds the number involved in Watson-Crick base pairs. This structure will aid mechanistic analyses of ribosomal frameshifting.

Non-NASA Center↗

Probing Operando Electrochemical Strain Generation in α-NaFeO 2 Composite Cathodes during Cycling of Na-Ion Batteries

The transition metal oxide (TMO) cathodes in Na-ion batteries suffer from low-capacity retention. Chemo-mechanical instabilities lead to the deterioration of the electrochemical performance of TMO cathodes in Li-ion batteries. However, there is not much known about the chemo-mechanical instabilities in the TMO cathodes for Na-ion batteries. Understanding the governing forces behind the interplay between the electrochemical performance and mechanical stability in TMO cathodes is critical for the development of Na-ion batteries. Here, we synchronize the digital image correlation (DIC) technique with electrochemical analysis to capture the real-time deformation behavior of the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage is 3.6 V, the cathode experiences reversible deformations (except for the first cycle). There is negative strain (shrinkage) generation during Na extraction and positive strain (expansion) generation during the subsequent Na insertion. A detailed analysis of the potential-dependent strain rate evolution points out complicated phase transformations and nonequilibrium conditions in the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage was increased to 4.2 V, there was a rapid capacity loss and large plastic deformations in the α-NaFeO 2 cathodes. We provide an in-depth discussion about the possible mechanisms behind the chemo-mechanical instabilities in the α-NaFeO 2 . In conclusion, the correlation is critical to develop material-based strategies to mitigate instability mechanisms in TMO cathodes for Na-ion batteries.

Wable, Minal [University of Maryland Baltimore Cou↗

Three-dimensional Model of Tissue and Heavy Ions Effects

A three-dimensional tissue model was incorporated into a new Monte Carlo algorithm that simulates passage of heavy ions in a tissue box . The tissue box was given as a realistic model of tissue based on confocal microscopy images. The action of heavy ions on the cellular matrix for 2- or 3-dimensional cases was simulated. Cells were modeled as a cell culture monolayer in one example, where the data were taken directly from microscopy (2-d cell matrix), and as a multi-layer obtained from confocal microscopy (3-d case). Image segmentation was used to identify cells with precise areas/volumes in an irradiated cell culture monolayer, and slices of tissue with many cell layers. The cells were then inserted into the model box of the simulated physical space pixel by pixel. In the case of modeled tissues (3-d), the tissue box had periodic boundary conditions imposed, which extrapolates the technique to macroscopic volumes of tissue. For the real tissue (3-d), specific spatial patterns for cell apoptosis and necrosis are expected. The cell patterns were modeled based on action cross sections for apoptosis and necrosis estimated from current experimental data. A spatial correlation function indicating a higher spatial concentration of damaged cells from heavy ions relative to the low-LET radiation cell damage pattern is presented. The spatial correlation effects among necrotic cells can help studying microlesions in organs, and probable effects of directionality of heavy ion radiation on epithelium and endothelium.

Ponomarev, Artem L.↗

Membrane peptides and their role in protobiological evolution

How simple membrane peptides performed such essential protocellular functions as transport of ions and organic matter across membranes separating the interior of the cell from the environment, capture and utilization of energy, and transduction of environmental signals, is a key question in protobiological evolution. On the basis of detailed, molecular-level computer simulations we explain how these peptides fold at water-membrane interfaces, insert into membranes, self-assemble into higher-order structures and acquire functions. We have investigated the interfacial behavior and folding of several peptides built of leucine and glutamine residues and have demonstrated that many of them tend to adopt ordered structures. Further, we have studied the insertion of an alpha-helical peptide containing leucine (L) and serine (S) of the form (LSLLLSL)3 into a model membrane. The transmembrane state is metastable, and approximately 15 kcal mol(-1) is required to insert the peptide into the membrane. Investigations of dimers formed by (LSLLLSL)3 and glycophorin A demonstrate how the favorable free energy of helix association can offset the unfavorable free energy of insertion, leading to self-assembly of peptide helices in the membrane. An example of a self-assembled structure is the tetrameric transmembrane pore of the influenza virus M2 protein, which is an efficient and selective voltage-gated proton channel. Our simulations explain the gating mechanism and provide guidelines how to re-engineer the channel to act as a simple proton pump. In general, emergence of integral membrane proteins appears to be quite feasible and may be easier to envision than the emergence of water-soluble proteins.

Models, Chemical↗

Flammability and Photo-Stability of Selected Polymer Systems

A systematic approach to the improvement of the flammability of epoxy resins, bisphenol-A polycarbonate poly(butylene terephthalate), and Nylon 6.6 by introducing halogens and loop functionality into the flame retardants is described. The phthalides (the loop functionality containing molecules) include 3,3-bis(4-bromophenyl)-phthalide, 3,3-bis(4-chlorophenyl)phthalide, and phenolphthalein. The phthalide containing epoxy resins are synthesized and characterized in comparison with the bisphenol-A epoxy resins in terms of flammability in the copolymer systems. The resins include diglycidyl ethers of phenolphthalein, bisphenol-A. tetrabromobisphenol-A, and tetraoromophenolphthalein. The vaporization of the phthalide additive in the polymers is observed in Thermal Gravimetric Analysis. The flame retardancy is primarily due to the presence of halogens. In the poly(butylene terephthalate) system, the cleavage of the C(sub aromatic) -B bond of the flame retardant additive enhances the crosslinking react ions between the aromatic rings resulting in an increase of char formation. In the epoxy resin systems, loop functionality contributes to char formation to a larger extent. The interaction between the epoxy resin and poly-(butylene terephthalate) follows the mechanism of insertion of the oxirane ring into the ester bond. This mechanism is studied by FT-IR. The investigation of the thermal properties of the char-forming phenol-formaldehyde resins is conducted to provide information for the systematic design of high temperature flame-resistant phenolics. NMR and FT-IR are used to characterize the oligomeric resins and the cured resins. The curing agents used in the study include formaldehyde, s-trioxane and terephthaloyl chloride. The brominated phenolic resins are found to have higher oxygen indices with lower char yields.

Lo, Jeelin↗

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗