Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Post-flight Analysis of the Argon Filled Ion Chamber

Atmospheric ionizing radiation is a complex mixture of primary galactic and solar cosmic rays and a multitude of secondary particles produced in collision with air nuclei. The first series of Atmospheric Ionizing Radiation (AIR) measurement flights on the NASA research aircraft ER-2 took place in June 1997. The ER-2 flight package consisted of fifteen instruments from six countries and were chosen to provide varying sensitivity to specific components. These AIR ER-2 flight measurements are to characterize the AIR environment during solar minimum to allow the continued development of environmental models of this complex mixture of ionizing radiation. This will enable scientists to study the ionizing radiation health hazard associated with the high-altitude operation of a commercial supersonic transport and to allow estimates of single event upsets for advanced avionics systems design. The argon filled ion chamber representing about 40 percent of the contributions to radiation risks are analyzed herein and model discrepancies for solar minimum environment are on the order of 5 percent and less. Other biologically significant components remain to be analyzed.

Tai, H.↗

Cold cathode switching device and converter

A cold-cathode switching device is presented. The cold-cathode switching device includes a housing defining a chamber; an ionizable gas disposed in the chamber; and a plurality of electrodes disposed in the chamber. The plurality of electrodes includes a cathode and an anode defining a discharge gap, and wherein at least one of the cathode and anode comprises a material that is liquid at an operating temperature of the cathode or the anode.

42 ENGINEERING↗

Vacuum ultraviolet source.

Low inductance three-electrode spark source for vacuum UV generating high degree ionization spectra

ULTRAVIOLET SPECTRUM↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Use of Receiver Operating Curve Analysis and Machine Learning With an Independent Dose Calculation System Reduces the Number of Physical Dose Measurements Required for Patient-Specific Quality Assurance

Our purpose was to assess the use of machine learning methods and Mobius 3D (M3D) dose calculation software to reduce the number of physical ion chamber (IC) dose measurements required for patient-specific quality assurance during corona virus disease 2019.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam particle identification and tagging of incompletely stripped heavy beams with HEIST

A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure the time-of-flight, a multi-sampling ion chamber to measure energy loss, and a high-purity germanium detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified 198 Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89% of all 198 Pb 80+ in the beam had a purity of 86%. We examine the issues of charge state contamination. Here, the observed charge state populations of these ions are presented and, using an adjusted beam energy, are well described by the charge state model GLOBAL.

47 OTHER INSTRUMENTATION↗

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%–70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

DESI↗

Charge carrier mobility of halide perovskite single crystals for ionizing radiation detection

Halide perovskites have recently emerged as promising semiconductor materials for several applications including solar cells, light-emitting diodes (LEDs), and radiation detectors. The charge carrier transport properties, which could be evaluated by the mobility-lifetime (mu-tau or μ-г) product, serve an important role for the development of halide perovskites for radiation detection applications. In this perspective, we firstly explain the charge transport mechanism and the limiting factors that determine the intrinsic charge carrier mobility in halide perovskite single crystals. Then, we overview the techniques and methods that have been employed for evaluating the charge carrier mobility (for both electrons and holes). Lastly, we discuss the discrepancy between the experimentally determined carrier mobility from the literature for halide perovskite single crystals and a perspective on future developments for carrier mobility enhancement is provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Compton scattering↗