Search NASA⌕ Search

SEARCH · Search NASA

Results for “levelized cost of storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Sodium-ion Battery

Room temperature rechargeable sodium-ion batteries (NIBs) are one of the most promising candidates for large-scale energy storage and load leveling of renewable energy sources due to the abundance, low cost of Na resources, and their relatively high energy density. NIBs are primarily based on intercalation chemistry and are similar to Lithium-ion batteries (LIB). The rich knowledge gained in LIBs for the past 4 decades have accelerated the discovery and development of high energy density NIBs cathode and anode materials. The use of sustainable Na, Al current collector, and Mn and Fe based cathode materials is expected to stabilize the cost and demand for Li, Co, Ni and Cu.

Omenya, Fredrick O.↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Hydrogen-Battery Hybrid Energy System on Repurposed Offshore Platforms for Efficient Clean-Energy Transition

Due to the rising global energy demand and enhanced awareness of the environmental impact of fossil fuels, the Gulf of Mexico, traditionally known for oil extraction, offers a distinct chance to repurpose the existing offshore infrastructure. With the depletion of oil reserves, it is feasible to adapt previously utilized floating platforms for extraction to generate renewable energy, specifically through wind-generated power and hydrogen production. This adaptation seeks to promote a transport system that is more ecologically friendly in the future. Offshore wind turbines serve as the main energy source, with help from battery storage and hydrogen production to enhance the overall system performance, hydrogen creation, fuel, and electricity delivery for sustainable energy production. The system is divided into two distinct cases, each evaluated for cost, performance, and feasibility, with a focus on minimizing both the Levelized Cost of Energy (LCOE) and the Levelized Cost of Hydrogen (LCOH). The first case examines the integration of offshore wind turbines with hydrogen production. Excess electricity generated by wind turbines is directed toward hydrogen production via electrolysis. The hydrogen produced can be used as fuel for vehicles or transported to the shore via pipelines. The second case investigates a technology that combines wind turbines with battery storage. The batteries possess an ability to supply electricity for a continuous duration of 4 hours maximum each day. The main objective is to reduce the LCOE by considering the battery's charging and discharging cycles, together with the uncertain attributes of wind power and battery deterioration. The produced energy can be distributed for onshore applications or utilized for the purpose of offsetting offshore loads such as subsea oil and gas production, transportation, etc. The offshore hydrogen-battery hybrid system is improved via three advanced algorithms, Particle Swarm Optimization (PSO), and Grey Wolf Optimizer (GWO). In Case 1, PSO improves hydrogen production by efficiently managing the electrolyzer’s power consumption, decreasing production costs significantly. Particle Swarm Optimization (PSO) is applied to improve the efficiency of the electrolyzer, reducing production costs and achieving an optimized CAPEX of $240.00 million (from an initial $300.00 million) and OPEX of $9.60 million per year. This system produces 4,720,000 kg of hydrogen annually, with a Levelized Cost of Hydrogen (LCOH) of $6.40/kg and an annual profit of $9.27 million. In Case 2, GWO effectively reduces the overall energy cost by improving the charge-discharge management of batteries, which extends battery life and optimizes their use. The second case focuses on integrating battery storage, optimized using the Grey Wolf Optimizer (GWO), which enhances battery charge-discharge cycles, extending battery life and lowering costs. This system achieves an optimized CAPEX of $204.80 million (from an initial $256.00 million) and OPEX of $9.29 million per year, producing 310883.39 MWh of electricity annually at a Levelized Cost of Energy (LCOE) of $86.13/MWh, with an annual profit of $6.25 million. The implementation of a comprehensive strategy results in a substantial reduction in costs, improved energy efficiency, and a dependable supply of both electric power and hydrogen, emphasizing the benefits of converting offshore oil platforms for clean energy transition. This study explores a clean strategy to enable cost-effective repurposing of offshore O&G platforms. Both cases highlight the economic and technical feasibility of transitioning offshore oil platforms to clean energy systems, demonstrating substantial cost reductions and reliable energy and hydrogen supplies for sustainable energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic Flux Compression Concept for Aerospace Propulsion and Power

The objective of this research is to investigate system level performance and design issues associated with magnetic flux compression devices for aerospace power generation and propulsion. The proposed concept incorporates the principles of magnetic flux compression for direct conversion of nuclear/chemical detonation energy into electrical power. Specifically a magnetic field is compressed between an expanding detonation driven diamagnetic plasma and a stator structure formed from a high temperature superconductor (HTSC). The expanding plasma cloud is entirely confined by the compressed magnetic field at the expense of internal kinetic energy. Electrical power is inductively extracted, and the detonation products are collimated and expelled through a magnetic nozzle. The long-term development of this highly integrated generator/propulsion system opens up revolutionary NASA Mission scenarios for future interplanetary and interstellar spacecraft. The unique features of this concept with respect to future space travel opportunities are as follows: ability to implement high energy density chemical detonations or ICF microfusion bursts as the impulsive diamagnetic plasma source; high power density system characteristics constrain the size, weight, and cost of the vehicle architecture; provides inductive storage pulse power with a very short pulse rise time; multimegajoule energy bursts/terawatt power bursts; compact pulse power driver for low-impedance dense plasma devices; utilization of low cost HTSC material and casting technology to increase magnetic flux conservation and inductive energy storage; improvement in chemical/nuclear-to-electric energy conversion efficiency and the ability to generate significant levels of thrust with very high specific impulse; potential for developing a small, lightweight, low cost, self-excited integrated propulsion and power system suitable for space stations, planetary bases, and interplanetary and interstellar space travel; potential for attaining specific impulses approaching 10 (exp 6) seconds, which would enable missions to the outer planets within ten years and missions at interstellar distances within fifty years.

Litchford, Ron J.↗

Energy Storage Analysis

This study presents a comprehensive techno-economic characterization of energy storage and exible low carbon power generation technologies that can shift energy across days, weeks, or months to balance daily, weekly, and seasonal disparities in supply and demand. Energy storage technologies evaluated here include pumped hydropower storage (PHS), adiabatic and diabatic compressed air energy storage (CAES), vanadium redox flow batteries (VRBs), pumped thermal energy storage (P-TES), and renewably produced hydrogen stored in either geologic formations or underground pipes with re-electrification via combustion turbines in combined cycles, stationary proton exchange membrane (PEM) fuel cells, or the novel use of PEM fuel cells designed for heavy-duty vehicles (HDVs) which are expected to have shorter lives but also lower capital costs. We also evaluate flexible low-carbon power generation systems, including ethanol combustion in gas turbines and natural gas combustion with carbon capture and sequestration (CCS). We estimate current costs with literature data, use learning rates to characterize future costs, and develop capacity factors calibrated to an 85% renewables grid to calculate the levelized cost of energy (LCOE) of each technology. Results illustrate that at the 12-hour storage duration, PHS and CAES have the lowest LCOE with current costs, and VRBs become competitive if future costs are achieved. At the 120-hour storage duration, hydrogen systems with geologic storage and natural gas with CCS achieve the lowest LCOE in both current and future capital cost scenarios. In particular, the new configuration of HDV-PEM fuel cells with hydrogen storage in geologic formations evaluated here could lower the LCOE by 22-27% compared to stationary fuel cell systems typically evaluated and might help enable very high (>80%) renewable energy electric power systems. P-TES and hydrogen stored in underground pipes are the least-cost options at the 120-hour storage duration rating that do not require some form of geologic storage. Sensitivity analysis and Monte Carlo analysis illustrate that the general trends seen in this study are valid for a wide range of capacity factors and future cost scenarios. The study also illustrates that coproducing and selling hydrogen to other markets could reduce the LCOE of hydrogen systems by up to 39%.

carbon capture and sequestration↗

2023 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2023 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

Impact of Thermal Plant Operational Flexibility on VRE Curtailment: The Curtailment Paradox

This presentation provides an overview of a previously published paper in Joule "The curtailment paradox in the transition to high solar power systems." The adoption of PV and battery storage has accelerated globally in recent years, driven by rapid cost declines. A corresponding increase in curtailment is anticipated as PV growth continues. This study explores the effect of system flexibility options on curtailment across increasing PV penetration levels. Results highlight a paradox where thermal generator flexibility matters most only at mid-PV penetration levels (25%-40%), and a misalignment exists where PV provides system value by providing operating reserves without sufficient opportunity for monetary compensation.

capacity expansion modeling↗

Solar Steam on Demand

INTRODUCTION: This Report summarizes the research and development project performed by Sunvapor and the subrecipient National Renewable Energy Laboratory (NREL) during the period of 10/01/2018-9/30/2021. The work was aimed at the economic integration of solar steam with an industrial process, and in particular, the advantages that a novel type of thermal energy storage and collector design could bring to the system. The completed work includes experimental research on the storage material, design of the collector, engineering of a complete solar steam plant, and economic analysis. The plant was, in the end, not constructed, due to COVID-19 impacts to the project host. PURPOSE: The purpose of the project was to test the hypothesis that a levelized cost of heat (LCOH) of 2¢/kWh delivered to a steam-consuming process, including energy discharged from storage, could be feasibly achieved. PROJECT OBJECTIVES: For Budget Period 1 our objectives were to engineer a prototype industrial solar steam generation system, and design and test a Latent Heat Energy Storage (LHES) lab-scale system. For Budget Period 2 our objectives were to construct and test the solar steam prototype plant, and to build and factory-test a full LHES module. For Budget Period 3 our objective was to integrate the storage module with the solar steam generator, show successful long duration energy tests of the combined system, and use the results to project the LCOH of delivered steam to a second-generation plant. PROJECT OUTCOMES: Various phase change materials (PCMs) for the LHES were tested for compatibility with industrial steam uses as measured by phase change temperature, stability of latent heat of fusion, and their corrosive effects on steel (the heat exchanger material). Two of these materials (sodium formate and sodium/ potassium) showed potential to meet the technical criteria. The estimated cost of a complete LHES module with these materials did not meet economic targets. The developmental collector design builds from previous work to exploit the potential cost advantages of a spaceframe of lumber construction. Design improvements were achieved in assembly efficiency and structural performance. A complete engineering package was completed for the solar steam system without storage that included the developmental as well as commercial arrays. The plant was permitted for construction. The storage CAPEX for a reference plant was estimate to be greater than $\$ 57$/kWh. The LCOH of the system without storage and with developmental collectors of lumber construction was projected to be 2¢/kWh, assuming a FCR of 8.2% over thirty years. PROJECT MILESTONES: The Milestones fully achieved in the first Budget Period includes obtaining a Letter of Intent from an industrial steam-consuming project host, issuance of a construction permit, and corrosion resistance. The Milestone that was partly achieved was the degradation in the latent heat of fusion. Milestones associated with Budget Periods 2 and 3, related to the construction and operation of the plant were not achieved as a result of the host shutting down the plant due to COVID-19 impacts. CONCLUSIONS: Sunvapor was able to secure an agreement with a host to build a fully engineered and permitted solar steam plant that met the host’s economic goals. As a basis for comparison, the solar field design was comprised of eight commercial collector arrays and one developmental Green Parabolic Trough Collector (GPTC) array. The projected LCOH with a solar field entirely populated with a second generation GPTC met the goal of 2¢/kWh. The experimental program concerning the PCM indicated the feasibility of meeting their technical requirements for industrial steam uses. The cost of the complete LHES exceeded its $\$ 14$/kWh target, and therefore the inclusion of LHES could not be economically justified. Due to COVID-19 impacts on the host, the solar steam plant was not constructed.

14 SOLAR ENERGY↗

2024 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2024 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

2021 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

Starting in 2015 NREL has presented the Annual Technology Baseline (ATB) in an Excel workbook that contains detailed cost and performance data, both current and projected, for renewable and conventional technologies. The workbook includes a spreadsheet for each technology. This version of the workbook provides the final updates to data for the 2021 ATB. In 2019 and 2020, NREL has also provided selected data in Tableau workbooks and structured summary csv files. The data for 2015 - 2020 is located on https://data.nrel.gov. In 2021 and going forward, the data is cloud optimized and provided in the OEDI data lake. A website documents this and future data at https://atb.nrel.gov.

Array↗

2022 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2022 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

Carbon storage cost modeling for the offshore Gulf of Mexico

Groundbreaking for geologic carbon storage (GCS) projects in the offshore Gulf of Mexico is imminent, and there is great interest in utilizing this region for GCS projects. Offshore saline reservoirs provide a significant and accessible resource for GCS. However, conducting GCS in the offshore environment will pose distinct challenges pertaining to site selection, operations, infrastructure use, and monitoring compared to operating onshore that ultimately affect technoeconomic assessment of offshore GCS projects. Carbon storage and transport costs are critical to project developers looking to deploy carbon storage in the offshore environment. We present CO2_S_COM_Offshore, a model developed by the National Energy Technology Laboratory (NETL) as a screening-level offshore saline GCS cost modeling tool. Based on NETL’s widely used CO2_S_COM cost model for onshore saline CS, CO2_S_COM_Offshore enables technoeconomic analysis of GCS in offshore areas. This model comprehensively incorporates multiple facets of offshore GCS projects, from regional evaluation and site selection to permitting, transport, operations, monitoring, site closure, and decommissioning. In general, the model can explore the cost implications for potential offshore GCS project(s) by enabling the user to change several project operational and financial attribute configurations. Key inputs include offshore storage formation options, CO2 injection rate and duration, infrastructure types, monitoring intensity, project financing, and post-injection site care duration. Supporting cost algorithms within CO2_S_COM_Offshore were compiled utilizing S&P Global’ s QUE$TORTM cost estimation software alongside a variety of open-source scientific literature. In addition to reviewing key model components, we discuss several sensitivity analyses, input variabilities, and results on analysis of break-even CO2 price required by a project based on different regulation/policy and operational scenarios for the offshore Gulf of Mexico. These results indicate the value of modeling offshore GCS specifically, and the potential of offshore GCS within a decarbonization value chain. Presented at the 41st USAEE/IAEE North American Conference, 3-6 November 2024, Baton Rouge, LA, United States.

Mark-Moser, Mackenzie K.↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks: Q1 2021

NREL has been modeling U.S. solar photovoltaic (PV) system costs since 2009. This year, our report benchmarks costs of U.S. PV for residential, commercial, and utility-scale systems, with and without storage, built in the first quarter of 2021 (Q1 2021). The methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems and it models the capital costs and levelized cost of energy for such systems.

14 SOLAR ENERGY↗

Using hydrogen and ammonia for renewable energy storage: A geographically comprehensive techno-economic study

Hydrogen and, more recently, ammonia have received worldwide attention as energy storage media. In this work we investigate the economics of using each of these chemicals as well as the two in combination for islanded renewable energy supply systems in 15 American cities representing different climate regions throughout the country. We use an optimal combined capacity planning and scheduling model which minimizes the levelized cost of energy (LCOE) by determining optimal unit selection and size along with unit commitments, production rates, and storage inventories for each period of system operation. These periods are aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. Ammonia is generally more economical than hydrogen as a single method of energy storage. Additionally, systems which use both hydrogen and ammonia outperform those which use only one storage option and have LCOE between $\$ 0.17$/kWh and $\$ 0.28$/kWh, including full investment in renewable generation infrastructure.

25 ENERGY STORAGE↗

Cost and size estimates for an electrochemical bulk energy storage concept

Preliminary capital cost and size estimates were made for an electrochemical bulk energy storage concept. The electrochemical system considered was an electrically rechargeable flow cell with a redox couple. On the basis of preliminary capital cost estimates, size estimates, and several other important considerations, the redox-flow-cell system emerges as having great promise as a bulk energy storage system for power load leveling. The size of this system would be less than 2 percent of that of a comparable pumped hydroelectric plant. The capital cost of a 10-megawatt, 60- and 85-megawatt-hour redox system is estimated to be $190 to $330 per kilowatt. The other important features of the redox system contributing to its load leveling application are its low adverse environmental impact, its high efficiency, its apparent absence of electrochemically-related cycle life limitations, and its fast response.

Warshay, M.↗

Development of a differentially balanced magnetic bearing and control system for use with a flywheel energy storage system

The purpose of a magnetically suspended flywheel energy storage system for electric utility load leveling is to provide a means to store energy during times when energy is inexpensive to produce and then return it to the customer during times of peak power demand when generated energy is most expensive. The design of a 20 kWh flywheel energy storage system for electric utility load leveling applications involves the successful integration of a number of advanced technologies so as to minimize the size and cost of the system without affecting its efficiency and reliability. The flywheel energy storage system uses a carbon epoxy flywheel, two specially designed low loss magnetic bearings, a high efficiency motor generator, and a 60 cycle AC power converter all integrated through a microprocessor controller. The basic design is discussed of each of the components that is used in the energy storage design.

Higgins, Mark A.↗