Search NASA⌕ Search

SEARCH · Search NASA

Results for “load calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Automatic releveling of calibration stands for wind tunnel force and moment measurement instrumentation

Wind tunnel force and moment measuring instrumentation at NASA LaRC are calibrated by applying NIST certified dead loads, to generate forces and moments in three orthogonal axes, in twenty five percent increments, up to full-load and down to no-load in a nine point continuous procedure, using specially built calibration stands. The measuring instruments deflect upon the application of loads. These deflections must be cancelled to minimize loading interactions. The older calibration stands, integrated with AC induction motors, or DC motors, have provisions for manually releveling the loading point after each load. A newer stand, with integrated DC stepper motors, relevels automatically under software control. It was proposed to extend automation to the old stands. An algorithm to control the unwieldy induction motors to relevel a calibration stand, to within two arcseconds of horizontal direction automatically, was developed. The system developed uses coasting prediction and load adaptation in a general type robust stability control configuration with noncoincidental feedback. Automatic releveling cuts the releveling time to approximately half of the time required to do it manually. The principal constraint for shorter times is the time constant of the angular position feedback transducer.

Perazza, Manuel Rodriguez↗

Sulfur mass loading of the atmosphere from volcanic eruptions: Calibration of the ice core record on basis of sulfate aerosol deposition in polar regions from the 1982 El Chichon eruption

Major volcanic eruptions disperse large quantities of sulfur compound throughout the Earth's atmosphere. The sulfuric acid aerosols resulting from such eruptions are scavenged by snow within the polar regions and appear in polar ice cores as elevated acidity layers. Glacio-chemical studies of ice cores can, thus, provide a record of past volcanism, as well as the means for understanding the fate of volcanic sulfur in the atmosphere. The primary objectives of this project are to study the chemistry and physical properties of volcanic fallout in a Greenland Ice Core in order to evaluate the impact of the volcanic gases on the atmospheric chemistry and the total atmospheric mass of volcanic aerosols emitted by major volcanic eruptions. We propose to compare the ice core record to other atmospheric records performed during the last 10 years to investigate transport and deposition of volcanic materials.

Sigurdsson, Haraldur↗

Static coefficient test method and apparatus

The static coefficient of friction between contacting surfaces of a plurality of bodies is determined by applying a load to the bodies in a direction normal to the contacting surfaces. Opposite ends of a flexible filament are connected to a load cell and the first of the bodies. A motor continuously moves the second of the bodies away from the load cell at constant velocity at right angles to the force of the normal load so that the first body moves intermittently relative to the second body across a contact surface between them. The load on the surfaces, the nature of the surfaces, and the speed of the first body relative to the load cell are such that the filament is alternately and cyclically tensioned and relaxed as the movement occurs. The maximum tension occurs at the incipient stages of movement of the first body relative to the second body. The load cell derives a series of measurements which are coupled to an x-y recorder, from which the maximum forces of the filament are determined to enable the static coefficient of friction to be determined. From the maximum forces and the normal force, the coefficient is determined. For determining coefficients of friction where there are large compression loads, the normal load is applied with a calibrated compression spring that is deflected by a predetermined amount determined by a spring load vs. deflection calibration curve.

Haehner, C. L.↗

Lessons Learned from SMAP Radiometer Pre-/Post-launch Calibration

The Soil Moisture Active Passive(SMAP) mission was launched on 31stJanuary 2015 in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude to measure soil moisture and free/thaw globally [1]. The passive instrument of SMAP is a fully polarimetric L-band radiometer (1.4GHz) operating with a bandwidth of 24MHz. The radiometer uses a combination of noise-diodes and Dicke-loads for internal calibration with a design similar to that used by the Aquarius or Jason series radiometers[2,3].Pre-launch calibration activities had been performed since 2012on the engineering model of the radiometer. Post-launch calibration activities have been performed to fine-tune and validate the results from the pre-launch calibration. The major calibration activities and lessons learned in the past 8 years will be described in the following sections.

Jinzheng Peng↗

Development of Design Analysis Methods for C/SiC Composite Structures

The stress-strain behavior at room temperature and at 1100 C (2000 F) was measured for two carbon-fiber-reinforced silicon carbide (C/SiC) composite materials: a two-dimensional plain-weave quasi-isotropic laminate and a three-dimensional angle-interlock woven composite. Micromechanics-based material models were developed for predicting the response properties of these two materials. The micromechanics based material models were calibrated by correlating the predicted material property values with the measured values. Four-point beam bending sub-element specimens were fabricated with these two fiber architectures and four-point bending tests were performed at room temperature and at 1100 C. Displacements and strains were measured at various locations along the beam and recorded as a function of load magnitude. The calibrated material models were used in concert with a nonlinear finite element solution to simulate the structural response of these two materials in the four-point beam bending tests. The structural response predicted by the nonlinear analysis method compares favorably with the measured response for both materials and for both test temperatures. Results show that the material models scale up fairly well from coupon to subcomponent level.

Sullivan, Roy M.↗

Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead of cryogens and measurement of the heat load with a calibrated heat conduction rod. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized Mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the aluminum coating on the Mylar might not be thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature, whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Multilayer insulation↗

Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K cold outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead cryogens and measurement of the heat load with a calibrated rod to serve as a conduction path. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the mylar coating might not thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature. Whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Cryogenics↗

A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

Mejia, M.↗

Calibration and Data Analysis Recommendations for Three-Component Moment Balances

Fundamental characteristics of design, calibration, and application of three-component moment balances are investigated in great detail. These balances are typically used to determine loads on control surfaces, canards, or other parts that are attached to a wind tunnel model. First, three different descriptions of the load state of a moment balance are reviewed. Then, load transformations between different load formats and the combined load diagram for two of the three load components are discussed. An error analysis showed that it is critical to maximize the product of the distance between the bending moment gages and their sensitivities in order to minimize the overall error in the normal force prediction. In addition, it is important to apply a sufficient number of calibration loadings near the first bending moment gage. Then, unwanted near-linear dependencies between the two bending moment gage outputs can be avoided. The error in the bending moment prediction is also investigated that results from the elastic deformation of the metric part of the balance under load. Finally, the application of the Non-Iterative Method to three-component moment balance calibration data is described in order to obtain regression models that can be used to predict loads from measured outputs during a wind tunnel test.

Strain-Gage Balance↗

Detection of Micro-Leaks Through Complex Geometries Under Mechanical Load and at Cryogenic Temperature

Polymer Matrix Composite (PMC) hydrogen tanks have been proposed as an enabling technology for reducing the weight of Single-Stage-to-Orbit reusable launch vehicles where structural mass has a large impact on vehicle performance. A key development issue of these lightweight structures is the leakage of hydrogen through the composite material. The rate of hydrogen leakage can be a function of the material used, method of 6 fabrication used to manufacture the tank, mechanical load the tank must react, internal damage-state of the material, and the temperatures at which the tank must operate. A method for measuring leakage through a geometrically complex structure at cryogenic temperature and under mechanical load was developed, calibrated and used to measure hydrogen leakage through complex X-33 liquid-hydrogen tank structure sections.

Rivers, H. Kevin↗

Development of a C-ELS Specimen-Based Numerical Benchmark for Mode II Delamination and Assessment of Two VCCT-Based Propagation Strategies

A finite element (FE) benchmark example inspired by the calibrated end-loaded split (C-ELS) specimen is developed and used to assess the performance of delamination propagation capabilities based on linear elastic fracture mechanics (LEFM). The C-ELS specimen has the advantage of a longer region of stable delamination propagation compared to the existing mode II benchmark case. The new benchmark example may therefore provide a better assessment tool by enabling more stable crack growth in regions further away from the boundary conditions or load application. First, a benchmark result is created manually using two-dimensional finite element models of the C-ELS specimen with different delamination lengths. Second, the performance of the virtual crack closure technique (VCCT) delamination propagation capabilities in the Abaqus/Standard®1 FE code and the recently developed Progressive Release eXplicit-VCCT (PRX-VCCT) method are assessed by comparing the results to the benchmark case. Two examples with different starter delamination lengths are studied. A shorter starter length is chosen to create a scenario with unstable delamination propagation. A longer delamination encourages stable delamination propagation. Detailed results from three-dimensional analyses with aligned and misaligned meshes and two levels of mesh refinement are provided. In general, good agreement can be achieved between the results obtained from the quasi-static propagation analysis and the benchmark analysis. Numerical artifacts including anomalous unreleased nodes in the crack wake and zig-zag crack fronts occur for propagation analyses using Abaqus/Standard VCCT. In comparison, continuous, smooth, delamination fronts are observed for PRX-VCCT. The use of the benchmark case to assess different VCCT-based propagation strategies illustrates the value of establishing benchmark cases.

Composite Materials↗

A Phenomenological Durability Model for Environmental Barrier Coating Systems Subjected to Steam Oxidation

Environmental barrier coatings (EBC) are used to protect the silicon carbide fiber reinforced silicon carbide matrix (SiC/SiC) ceramic matrix composites (CMC) from rapid surface recession due to volatization by water vapor in a steam oxidation environment. A phenomenological modeling approach is outlined to estimate the durability of a given EBC system when exposed to steam oxidation. The report provides a step-by-step procedure to estimate the life of a given EBC system subjected to thermal loads only. Once calibrated, the methodology can predict the critical thickness of an oxide layer that will cause failure initiation/spallation as well as the remaining strength or stress that the EBC system can take for a given oxide layer thickness

Subodh K Mital↗

Iterative Strain-Gage Balance Calibration Data Analysis for Extended Independent Variable Sets

A new method was developed that makes it possible to use an extended set of independent calibration variables for an iterative analysis of wind tunnel strain gage balance calibration data. The new method permits the application of the iterative analysis method whenever the total number of balance loads and other independent calibration variables is greater than the total number of measured strain gage outputs. Iteration equations used by the iterative analysis method have the limitation that the number of independent and dependent variables must match. The new method circumvents this limitation. It simply adds a missing dependent variable to the original data set by using an additional independent variable also as an additional dependent variable. Then, the desired solution of the regression analysis problem can be obtained that fits each gage output as a function of both the original and additional independent calibration variables. The final regression coefficients can be converted to data reduction matrix coefficients because the missing dependent variables were added to the data set without changing the regression analysis result for each gage output. Therefore, the new method still supports the application of the two load iteration equation choices that the iterative method traditionally uses for the prediction of balance loads during a wind tunnel test. An example is discussed in the paper that illustrates the application of the new method to a realistic simulation of temperature dependent calibration data set of a six component balance.

Ulbrich, Norbert Manfred↗

Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

Ulbrich, N.↗

DSN water vapor radiometer: Tropospheric range delay calibration

A discussion is presented of the Deep Space Network water vapor radiometer by means of simultaneous antenna temperature and radiosonde measurements at Edwards Air Force Base. The calibration of radiometer gain and hot load radiometric noise temperature is also described. Calibration equations are given. It is found that with a selected data set, the RMS error is less than 1 cm over a total delay range of 9 to 38 cm. Limitations on the use of the water vapor radiometer are also given.

Slobin, S. D.↗

Prediction Interval Development for Wind-Tunnel Balance Check-Loading

Results from the Facility Analysis Verification and Operational Reliability project revealed a critical gap in capability in ground-based aeronautics research applications. Without a standardized process for check-loading the wind-tunnel balance or the model system, the quality of the aerodynamic force data collected varied significantly between facilities. A prediction interval is required in order to confirm a check-loading. The prediction interval provides an expected upper and lower bound on balance load prediction at a given confidence level. A method has been developed which accounts for sources of variability due to calibration and check-load application. The prediction interval method of calculation and a case study demonstrating its use is provided. Validation of the methods is demonstrated for the case study based on the probability of capture of confirmation points.

Landman, Drew↗

Hydraulic Calibrator for Strain-Gauge Balances

Instrument for calibrating strain-gauge balances uses hydraulic actuators and load cells. Eliminates effects of nonparallelism, nonperpendicularity, and changes of cable directions upon vector sums of applied forces. Errors due to cable stretching, pulley friction, and weight inaccuracy also eliminated. New instrument rugged and transportable. Set up quickly. Developed to apply known loads to wind-tunnel models with encapsulated strain-gauge balances, also adapted for use in calibrating dynamometers, load sensors on machinery and laboratory instruments.

Skelly, Kenneth↗