Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Single photon emitters in van der Waals solids for quantum photonics: materials, theory and molecular-scale characterization probes

Strong light–matter interactions in two-dimensional layered materials (2D materials) have attracted the interest of researchers from interdisciplinary fields for more than a decade now. A unique phenomenon in some 2D materials is their large exciton binding energies (BEs), increasing the likelihood of exciton survival at room temperature. It is this large BE that mediates the intense light–matter interactions of many of the 2D materials, particularly in their monolayer limit, where the interplay of excitonic phenomena poses a wealth of opportunities for high-performance optoelectronics and quantum photonics. Within quantum photonics, quantum information science (QIS) is growing rapidly, where photons are a promising platform for information processing due to their low-noise properties, excellent modal control, and long-distance propagation. A central element for QIS applications is a single photon emitter (SPE) source, where an ideal on-demand SPE emits exactly one photon at a time into a given spatiotemporal mode. Recently, 2D materials have shown practical appeal for QIS which is directly driven from their unique layered crystalline structure. This structural attribute of 2D materials facilitates their integration with optical elements more easily than the SPEs in conventional three-dimensional solid state materials, such as diamond and SiC. In this review article, we will discuss recent advances made with 2D materials towards their use as quantum emitters, where the SPE emission properties maybe modulated deterministically. Here, the use of unique scanning tunneling microscopy tools for the in-situ generation and characterization of defects is presented, along with theoretical first-principles frameworks and machine learning approaches to model the structure-property relationship of exciton–defect interactions within the lattice towards SPEs. Given the rapid progress made in this area, the SPEs in 2D materials are emerging as promising sources of nonclassical light emitters, well-poised to advance quantum photonics in the future.

2D layered materials↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Improving constraints on models addressing the Hubble tension with CMB delensing

The Hubble Tension is a well-known issue in modern cosmology that refers to the apparent disagreement in inferences of the Hubble constant H 0 as found through low-redshift observations and those derived from the ΛCDM model utilizing early universe observations. Several extensions to ΛCDM have been proposed to address the Hubble Tension that involve new ingredients or dynamics in the early universe. Reversing the effects of gravitational lensing on cosmic microwave background (CMB) maps produces sharper acoustic peaks in power spectra and allows for tighter constraints on cosmological parameters. We investigate the efficacy of CMB delensing for improving the constraints on parameters used in extensions of the ΛCDM model that are aimed at resolving the Hubble Tension (such as varying fundamental constants, contributions from early dark energy, and self-interacting dark radiation). We use Fisher forecasting to predict the expected constraints with and without this delensing procedure. We demonstrate that CMB delensing improves constraints on H 0 by ~ 20% for viable models and significantly improves constraints on parameters across the board in the low-noise regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wavelet flow for extragalactic foreground simulations

Extragalactic foregrounds in cosmic microwave background (CMB) observations are both a source of cosmological and astrophysical information and a nuisance to the CMB. Effective field-level modeling that captures their non-Gaussian statistical distributions is increasingly important for optimal information extraction, particularly given the low-noise observations from current and upcoming experiments. Here, we explore the use of Wavelet Flow (WF) models to tackle the novel task of modeling the field-level probability distributions of multi-component CMB secondaries and foregrounds. Specifically, we jointly train correlated CMB lensing convergence (κ) and cosmic infrared background (CIB) maps with a WF model and obtain a network that statistically recovers the input to high accuracy — the trained network generates samples of κ and CIB fields whose average power spectra are within a few percent of the inputs across all scales, and whose Minkowski functionals are similarly accurate compared to the inputs. Leveraging the multiscale architecture of these models, we fine-tune both the model parameters and the priors at each scale independently, optimizing performance across different resolutions. These results demonstrate that WF models can accurately simulate correlated components of CMB secondaries, supporting improved analysis of cosmological data. Our code and trained models can be found on this GitHub repo.

cosmological simulations↗

A combined Phase Contrast Imaging and heterodyne interferometer for multiscale fluctuation measurements in tokamak plasmas

An upgrade to the Phase Contrast Imaging (PCI) diagnostic on the DIII-D tokamak has successfully combined PCI with density interferometry to provide electron density fluctuation measurements across an unprecedented range in wavenumber. The combined diagnostic uses a single laser and a single beam path through the tokamak, minimizing machine resources in anticipation of future reactor-scale devices where port access will be at a premium. The PCI multichannel detector provides low-noise, wavenumber-resolved detection of moderate-wavenumber turbulence, while the interferometer channel is sensitive to long-wavelength turbulence, including the peak of ion-scale turbulence and MHD. The overlap in wavenumber range between the two schemes allows for an in situ absolute calibration of the PCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Minimally entangled state preparation of localized wave functions on quantum computers

Initializing a single site of a lattice scalar field theory into an arbitrary state with support throughout the quantum register requires $O(2^{nQ})$ entangling gates on a quantum computer with $n_Q$ qubits per site. It is conceivable that instead initializing to functions that are good approximations to states may have utility in reducing the number of required entangling gates. In the case of a single site of a noninteracting scalar field theory, initializing to a symmetric exponential wave function requires $n_Q – 1$ entangling gates, the minimal number necessary to create an entangled state of all $n_Q$ qubits. This is compared with the $2^{nQ – 1} + n_Q – 3 + δ_{nQ, 1}$ required for a symmetric Gaussian wave function. In this work, we explore the initialization of one-site $(n_Q = 4)$, two-site $(n_Q = 3)$, and three-site ( n Q = 3 ) noninteracting scalar field theories with symmetric exponential wave functions using IBM's quantum simulators and quantum devices (Poughkeepsie and Tokyo). With the digitizations attainable with $n_Q = 3,4$, these tensor-product wave functions are found to have large overlap with a Gaussian wave function and provide a suitable low-noise initialization for improvement and Somma inflation. Further, in performing these simulations, we have employed a workflow that interleaves calibrations to mitigate systematic errors in production. The calibrations allow tolerance cuts on gate performance including the fidelity of the symmetrizing Hadamard gate, both in vacuum $(|\textbf{0}\gg^{\bigotimes nQ})$ and in medium ($n_Q –1$ qubits initialized to an exponential function). The results obtained in this work are relevant to systems beyond scalar field theories, such as the deuteron radial wave function, two- and three-dimensional Cartesian-space wave functions, and nonrelativistic multinucleon systems built on a localized eigenbasis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Heralded Single-Photon Source with a Photon-Number-Resolving Superconducting Nanowire Detector

Deterministic generation of single photons is essential for many quantum information technologies. A bulk optical nonlinearity emitting a photon pair, where the measurement of one of the photons heralds the presence of the other, is commonly used with the caveat that the single-photon emission rate is constrained due to a trade-off between multiphoton events and pair emission rate. Using an efficient and low noise photon-number-resolving superconducting nanowire detector we herald, in real time, a single photon at telecommunication wavelength. We perform a second-order photon correlation g 2 ( 0 ) measurement of the signal mode conditioned on the measured photon number of the idler mode for various pump powers and demonstrate an improvement of a heralded single-photon source. We develop an analytical model using a phase-space formalism that encompasses all multiphoton effects and relevant imperfections, such as loss and multiple Schmidt modes. We perform a maximum-likelihood fit to test the agreement of the model to the data and extract the best-fit mean photon number μ of the pair source for each pump power. A maximum reduction of 0.118 ± 0.012 in the photon g 2 ( 0 ) correlation function at μ = 0.327 ± 0.007 is obtained, indicating a strong suppression of multiphoton emissions. For a fixed g 2 ( 0 ) = 7 × 10 − 3 , we increase the single pair generation probability by 25%. Our experiment, built using fiber-coupled and off-the-shelf components, delineates a path to engineering ideal sources of single photons.

Davis, Samantha I.↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstructing patchy reionization with deep learning

The precision anticipated from next-generation cosmic microwave background (CMB) surveys will create opportunities for characteristically new insights into cosmology. Secondary anisotropies of the CMB will have an increased importance in forthcoming surveys, due both to the cosmological information they encode and the role they play in obscuring our view of the primary fluctuations. Quadratic estimators have become the standard tools for reconstructing the fields that distort the primary CMB and produce secondary anisotropies. While successful for lensing reconstruction with current data, quadratic estimators will be suboptimal for the reconstruction of lensing and other effects at the expected sensitivity of the upcoming CMB surveys. In this paper we describe a convolutional neural network, ResUNet-CMB, that is capable of the simultaneous reconstruction of two sources of secondary CMB anisotropies, gravitational lensing and patchy reionization. Furthermore, we show that the ResUNet-CMB network significantly outperforms the quadratic estimator at low noise levels and is not subject to the lensing-induced bias on the patchy reionization reconstruction that would be present with a straightforward application of the quadratic estimator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigating foreground bias to the CMB lensing power spectrum for a CMB-HD survey

A promising way to measure the distribution of matter on small scales (k~10 h Mpc –1 ) is to use gravitational lensing of the cosmic microwave background (CMB). CMB-HD, a proposed high-resolution, low-noise millimeter survey over half the sky, can measure the CMB lensing auto spectrum on such small scales enabling measurements that can distinguish between a cold dark matter (CDM) model and alternative models designed to solve problems with CDM on small scales. However, extragalactic foregrounds can bias the CMB lensing auto spectrum if left untreated. Here, we present a foreground mitigation strategy that provides a path to reduce the bias from two of the most dominant foregrounds, the thermal Sunyaev-Zel’dovich effect and the cosmic infrared background. Given the level of realism included in our analysis, we find that the thermal Sunyaev-Zel’dovich alone and the cosmic infrared background alone bias the lensing auto spectrum by 0.6σ and 1.1σ, respectively, in the lensing multipole range of Lϵ[5000,20000] for a CMB-HD survey; combined these foregrounds yield a bias of only 1.3σ. Including these foregrounds, we also find that a CMB-HD survey can distinguish between a CDM model and a 10 –22 eV fuzzy dark matter model at the 5σ level. These results provide an important step in demonstrating that foreground contamination can be sufficiently reduced to enable a robust measurement of the small-scale matter power spectrum with CMB-HD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Small-correlated-against-large estimator for the lensing of the cosmic microwave background

Weak gravitational lensing of the cosmic microwave background (CMB) carries imprints of the physics operating at redshifts much lower than that of recombination and serves as an important probe of cosmological structure formation, dark matter physics, and the mass of neutrinos. Reconstruction of the CMB lensing deflection field through use of quadratic estimators has proven successful with existing data but is known to be sub-optimal on small angular scales ($\ell > 3000$) for experiments with low noise levels. Future experiments will provide better observations in this regime, but these techniques will remain statistically limited by their approximations. We show that correlations between fluctuations of the large-scale temperature gradient power of the CMB sourced by $\ell < 2000$, and fluctuations of the local small-scale temperature power reveal a lensing signal which is prominent in even the real-space pixel statistics across a CMB temperature map. We present the development of the Small Correlated Against Large Estimator (SCALE), a novel estimator for the CMB lensing spectrum which offers promising complementary analysis alongside other reconstruction techniques in this regime. The SCALE method computes correlations between both the large/small-scale temperature gradient power in harmonic space, and it is able to quantitatively recover unbiased statistics of the CMB lensing field without the need for map-level reconstruction. SCALE can outperform quadratic estimator signal-to-noise by a factor of up to 1.5 in current and upcoming experiments for CMB lensing power spectra $C_{6000 < L < 8000}^{\phi\phi}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New limit on dark photon kinetic mixing in the 0.2 – 1.2 μ eV mass range from the Dark E-field Radio experiment

We report new limits on the kinetic mixing strength of the dark photon spanning the mass range 0.21 − 1.24 μ eV corresponding to a frequency span of 50–300 MHz. The Dark E-field Radio experiment is a wideband search for dark photon dark matter. In this paper we detail changes in calibration and upgrades since our proof-of-concept pilot run. Our detector employs a wide-bandwidth E-field antenna moved to multiple positions in a shielded room, a low noise amplifier, wideband analog-to-digital converter, followed by a 2 24 -point fast Fourier transform. An optimal filter searches for signals with Q ≈ 10 6 . In nine days of integration, this system is capable of detecting dark photon signals corresponding to a kinetic mixing strength ε several orders of magnitude lower than previous limits. We find a 95% exclusion limit on ε over this mass range between 6 × 10 − 15 and 6 × 10 − 13 , tracking the complex resonant mode structure in the shielded room. Published by the American Physical Society 2024

Astronomy & Astrophysics↗