Search NASASearch

SEARCH · Search NASA

Results for “mid-frequency tensor gravitational-wave detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

372 records · Page 8

The Flight Performance of the Galileo Orbiter USO

Results are presented from an analysis of radio metric data received by the DSN stations from the Galileo spacecraft using an Ultrastable Oscillator (USO) as a signal source. These results allow the health and performance of the Galileo USO to be evaluated, and are used to calibrate this Radio Science instrument and the data acquired for Radio Science experiments such as the Red-shift Observation, Solar Conjunction, and Jovian occultations. Estimates for the USO-referenced spacecraft-transmitted frequency and frequency stability were made for 82 data acquisition passes conducted between launch (October 1989) and November 1991. Analyses of the spacecraft-transmitted frequencies show that the USO is behaving as expected. The USO was powered off and then back on in August 1991 with no adverse effect on its performance. The frequency stabilities measured by Allan deviation are consistent with expected values due to thermal wideband noise and the USO itself at the appropriate time intervals. The Galileo USO appears to be healthy and functioning normally in a reasonable manner.

D D Morabito

Updated global and regional trends of stratospheric ozone profiles

We present updated evaluation of stratospheric ozone profile trends in the 60° S–60°N latitude range using long-term ground-based and satellite climate data records, as well as simulations by chemistry-climate models. The trends are evaluated using the LOTUS (Long-term Ozone Trends and Uncertainties in the Stratosphere) regression model. Analyses of satellite data confirm the statistically significant positive ozone trends in the period 2000–2024 in the upper stratosphere of ~1–3% per decade, with larger trends at mid-latitudes compared to the tropics. The trends are slightly positive or close to zero in the middle stratosphere, and mostly negative, -1 to -2% per decade, in the lower stratosphere, but they are not statistically significant. The morphology and magnitude of ozone trends are similar to previous analyses (2000–2020 trends). Ozone trends in 2000–2024 predicted by chemistry-climate model simulations are in good agreement with combined satellite trends. In the upper stratosphere, models predict a slightly stronger ozone recovery than observations. In the lower stratosphere, both models and satellite observations report negative trends in the tropics, while modelled ozone trends are slightly positive at mid-latitudes. Ozone profile trends over several stations estimated from ground-based records capture the same overall vertical pattern of ozone trends as merged gridded satellite datasets. Analyses of regional ozone profile trends in 2003–2024 using merged satellite datasets confirmed the previous observations of a longitudinal structure in ozone trends in the NH mid-latitude stratosphere, with positive trends over Scandinavia and negative trends over Siberia. However, the magnitude of this dipole-like structure is reduced compared to previous analyses.

trends

Stability Measurements of the Radio Science System at the 34-m High-Efficiency Antennas

From 1991 to 1993 the fractional frequency stability of the operational Radio Science System was measured at DSS's 15, 45, and 65. These stations are designed to have the most stable uplink and downlink equipment in the Deep Space Network (DSN). Some measurements were performed when the antenna was moving and the frequency was ramped. The stability, including contributions of all elements in the station except for the antenna and the hydrogen maser, was measured to be 0.3 to 1.3 x 10 -15 when the frequency was fixed, and 0.6 to 6.0 x 10 -15 when the frequency was ramped (sample interval, 1000 sec). Only one measurement out of fifteen exceeded specification. In all other cases, when previous measurements on the antenna and the hydrogen maser were added, a total system stability requirement of 5.0 x 10 -15 as met. In addition, ambient temperature was found to cause phase variation in the measurements at a rate of 5.5 deg of phase per deg C.

T T Pham

The Future Polarized Target Program at Jefferson Lab

Polarized targets have played a crucial role in Jefferson Lab's exploration of nuclear structure over the past four decades. The three original experimental halls have seen 19 separate installations of polarized solid or gas targets for use in the particle physics scattering experiments, and this trend will continue in the next decade. Five polarized target systems are in preparation for use at JLab in the coming years. Hall B will see the use of two solid polarized targets, one longitudinally polarized to the beam, the other transversely, as well as a novel 3He gas polarized target. In Hall C, new experiments will augment the tensor polarization in dynamically polarized solids. Plans are under development to bring a polarized solid target to Jefferson Lab's photon beam hall, Hall D, for the first time. To support these efforts, the JLab polarized target group is building a test laboratory to develop dynamic nuclear polarization techniques, as well as an apparatus to irradiate target material using electrons from JLab's injector test facility. In this talk, we will explore the development progress and plans for each of these efforts.

Maxwell, James [Thomas Jefferson National Accelera

Final Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

In-Flight Calibration of ESA Hera’s Hyperscout-H Imager

ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.

Image Processing

Black-hole powered quantum coherent amplifier

Abstract Atoms falling into a black hole (BH) through a cavity are shown to enable coherent amplification of light quanta powered by the BH-gravitational vacuum energy. This process can harness the BH energy towards useful purposes, such as propelling a spaceship trapped by the BH. The process can occur via transient amplification of a signal field by falling atoms that are partly excited by Hawking radiation reflected by an orbiting mirror. In the steady-state regime of thermally equilibrated atoms that weakly couple to the field, this amplifier constitutes a BH-powered quantum heat engine. The envisaged effects substantiate the thermodynamic approach to BH acceleration radiation.

Physics

First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF

This work details the construction and first in operando transient grating spectroscopy measurements conducted on PISCES-RF during plasma operation. A preliminary study on a tungsten sample with varied plasma species (Ar and D 2 ), ion flux (4 × 10 21 to 6 × 10 22 ion/m 2 /s), ion energy (5 to 80 eV), and surface temperature (20 to 200 °C) is presented. Prior to plasma exposure, the thermal diffusivity and surface acoustic wave (SAW) speed, (6.9 ± 0.2) × 10 −5 m 2 /s and (2.66 ± 0.02) km/s, were measured in situ with a thermal grating period of 12.5 μm. During Ar plasma exposure, these two quantities vary according to the sample surface temperature. At low flux and varied ion energy, D 2 plasma exposure also results in thermal diffusivity and SAW speed varying with surface temperature alone. At high flux, D 2 plasma exposure results in no convincing change to the thermal diffusivity, but the SAW speed is reduced. After returning to 20 °C, post plasma exposures, the thermal diffusivity and SAW speed almost recover to the initial value prior to exposure.

Surface acoustic wave SAW

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ

Copacabana: a probabilistic membership assignment method for galaxy clusters

Cosmological analyses using galaxy clusters in optical/near-infrared photometric surveys require robust characterization of their galaxy content. Precisely determining which galaxies belong to a cluster is crucial. In this paper, we present the COlor Probabilistic Assignment of Clusters And BAyesiaN Analysis (Copacabana) algorithm. Copacabana computes membership probabilities for all galaxies within an aperture centred on the cluster using photometric redshifts, colours, and projected radial probability density functions. We use simulations to validate Copacabana and we show that it achieves up to 89 per cent membership accuracy with a mild dependence on photometric redshift uncertainties and choice of aperture size. We find that the precision of the photometric redshifts has the largest impact on the determination of the membership probabilities followed by the choice of the cluster aperture size. We also quantify how much these uncertainties in the membership probabilities affect the stellar mass–cluster mass scaling relation, a relation that directly impacts cosmology. Using the sum of the stellar masses weighted by membership probabilities (⁠μ * ⁠) as the observable, we find that Copacabana can reach an accuracy of 0.06 dex in the measurement of the scaling relation at low redshift for a Legacy Survey of Space and Time type survey. These results indicate the potential of Copacabana and μ * to be used in cosmological analyses of optically selected clusters in the future.

79 ASTRONOMY AND ASTROPHYSICS

Improving Marine Energy Production Through Commercialization of a Low Cost, Drag-Reducing Slippery Coating (CRADA 679 Abstract)

Marine energy capture systems offer great promise for providing clean energy, but they operate in a challenging and dynamic environment and must be optimized to the highest extent possible. Computational studies predict that drag reduction on marine energy and blue economy systems will result in meaningful improvements in energy efficiency. Based on extensive coating experience, PNNL is proposing to bring to market a new drag-reducing coating called Superhydrophobic Lubricant-Infused Drag-Efficient Coating – SLIDE-Coat. PNNL has a deep knowledge base regarding this class of slippery coatings, and we have a group of enthusiastic industry partners who have committed to partnering, conducting field testing, and providing well over 50% cost share. In addition to validating the technology, the team will create a commercialization roadmap to ensure the commercial success of the technology after the government-sponsored two-year program is complete. The main technical goal is to design, manufacture, and experimentally validate a new coating that can reduce hydrodynamic skin friction drag by 20%. The main commercialization goal is to develop a roadmap that identifies activities needed to complete SLIDE-Coat’s development after the conclusion of this project. Year 1 will focus on adaptation and modification of the existing SLIC coating system to optimize drag reduction and assessment and quantification of drag reduction on relevant materials in a laboratory setting. Year 2 will focus on optimizing and demonstrating drag reduction with preferred coatings. The manufacturability, ease of application, adhesion to relevant surfaces, and consistency will be assessed. Quantification of drag reduction on prototype materials in a relevant marine field setting will be executed.

16 TIDAL AND WAVE POWER

Vasomotion in Human Fingers

Introduction: We describe methods by which vasomotion can be recorded in awake and anesthetized human subjects without significant interference from other spontaneous vascular oscillations. Methods: In three separate studies, we used photoplethysmography (PPG) to record vasomotion in fingertips. In Study 1, we induced chemical sympathectomy in the studied hand of 11 awake subjects who received intravenous dexmedetomidine infusions. In Study 2, we administered four progressively increasing intravenous dexmedetomidine infusions to 16 awake volunteers. In Study 3, we recorded vasomotion simultaneously from 6 fingers of 7 patients who were under dexmedetomidine-based anesthesia. Five-minute epochs of PPG recordings that displayed slow vascular oscillations were analyzed for frequency and amplitude. Results: In Study 1, vasomotion frequencies were 0.025 ± 0.008 Hz. In Study 2, vasomotion frequencies were 0.033 ± 0.006 Hz, and 0.032 ± 0.008 Hz during the two highest dexmedetomidine infusion steps. In Study 3, vasomotion frequencies ranged from 0.020 to 0.037 Hz and were observed in all 6 fingers, with no synchrony between the six fingers. Conclusion: The vascular oscillations we observed without significant interference from other spontaneous oscillations are independent of neural activity (Study 1), local in nature (Study 3), and associated with alpha-2-adrenoceptor activation, consistent with known properties of vasomotion.

Cardiovascular System & Cardiology

Vanishing dynamic strength measured in a transient high-pressure phase of tin

This work reports two independent experimental estimations of the dynamic strength of the body-centered tetragonal (bct) 𝛾 phase of tin, which occurs at pressures above about 9 GPa and transforms promptly back to the ambient 𝛽 phase upon pressure release. Measuring strength in such a transient high-pressure phase is challenging. One measurement used free-surface Richtmyer-Meshkov instabilities generated with gas gun impact. Another set of measurements used ramp-release loading in a pulsed-power facility. Strength estimations came from comparison to simulations using a comprehensive multiphase modeling framework that includes equation of state, shear moduli, and strength separately for each phase, and treats mixed-phase regions. Both experimental methods found the 𝛾-phase strength to be very low, within experimental uncertainty of zero. The existing literature on other materials, by contrast, almost universally reports higher strength in transient high-pressure phases compared with ambient phases. Recent Molecular-Dynamics simulations on tin in the literature showed almost zero deviatoric strength during a deformation-induced bct → bct transformation in which one of the 𝛾-phase 𝑎 axes “flips” to the 𝑐 axis. This reorientation currently provides the most plausible explanation for the low observed strength in 𝛾-phase tin.

36 MATERIALS SCIENCE

Thermal expansion behavior of LDEF metal matrix composites

The effects of the space environment on the thermal expansion stability of metal matrix composites (graphite/Al and graphite/Mg) will be presented. A sample from each category of metal matrix composites mounted on the leading and trailing edge was chosen for analysis of the temperature-time-thermal strain histories. Typical thermal expansion curves over the same range of temperature were selected at the beginning, mid, and end of the recording duration. The thermal expansion of selected post-flight LDEF samples were measured over the same range of temperature in the laboratory using a Michelson laser interferometer. The thermal strains were monitored concurrently with a laser interferometer and a mounted strain gage.

T. D. Le

HRMS Sky Survey Wideband Feed System Design for DSS 24 Beam Waveguide Antenna

The High-Resolution Microwave Survey (HRMS) Sky Survey project will be implemented on the DSS 24 beam waveguide (BWG) antenna over the frequency range of 2.86 to 10 GHz. Two wideband, ring-loaded, corrugated feed horns were designed to cover this range. The horns match the frequency-dependent gain requirements for the DSS 24 BWG system. The performance of the feed horns and the calculated system performance of DSS 24 are presented.

P H Stanton

Power performance and loads characterization of laboratory-scale cross-flow rotors fabricated using additive manufacturing

Tidal energy conversion is a relatively new application for additive manufacturing (AM), where the focus has been on fabricating axial-flow turbine blades. AM techniques add material precisely where it is needed, creating more complex shapes with less waste. Cross-flow rotor geometry presents an opportunity for AM to improve rotor performance by fabricating features that cannot be created economically via conventional manufacturing. The challenges associated with using AM in cross-flow design include water resistance and degradation over time while retaining a level of quality equivalent to conventionally machined parts. In this work, AM materials were tested by environmentally conditioning samples in a seawater tank for 5 months, followed by performance and phase-resolved load testing of laboratory-scale rotors in a hydraulic flume. We found that while metals like titanium and Inconel have excellent performance in marine environments, achieving the desired geometry and performance is difficult. Thermoplastics degraded in seawater but were easier to form into desired geometries and could exceed the performance of an aluminum control rotor. Warping and surface finish were significant detractors from AM rotor performance. These results suggest that the primary benefits of using AM for cross-flow rotors is to quickly fabricate and test unconventional rotor geometries.

16 TIDAL AND WAVE POWER

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631

Radiation sensitivity of quartz crystal oscillators experiment for the Long Duration Exposure Facility (LDEF)

Factors determining the radiation sensitivity of quartz crystal oscillators were studied on NASA's LDEF. Quartz materials were examined in the transmission electron microscope (TEM) and classified as to their sensitivity to radiation damage by establishing the rate of damage caused by the electron beam in the microscope. Two types of materials, i.e., swept premium Q quartz and natural quartz were chosen because clear differences were observed in their response to the electron beam in the TEM studies. Quartz resonators were then fabricated from them, tested for frequency stability over a greater than 6 mo. period and flown on the LDEF satellite. After retrieval (more than 7 yrs in space) the stability of the resonators was again determined. All of the space exposed resonators fabricated with swept premium Q material exhibited a frequency shift above that of the control resonators: none of the resonators fabricated from the natural quartz materials exhibited such a shift. The significant differences observed between the two types of materials in both the ground-based TEM studies and the space radiation induced frequency changes suggest that there may be a correlation between the two observations.

J. S. Ahearn