Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical synchronization systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

System architecture of MMIC-based large aperture arrays for space applications

The persistent trend to use millimeter-wave frequencies for satellite communications presents the challenge to design large-aperture phased arrays for space applications. These arrays, which comprise 100 to 10,000 elements, are now possible due to the advent of lightwave technology and the availability of monolithic microwave integrated circuits. In this paper, system aspects of optically controlled array design are studied. In particular, two architectures for a 40 GHz array are outlined, and the main system-related issues are examined: power budget, synchronization in frequency and phase, and stochastic effects.

Herczfeld, P. R.↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Note: An improved calibration system with phase correction for electronic transformers with digital output

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous control of emission localization and two-photon absorption efficiency in dissymmetrical chromophores

The aim of the present work is to demonstrate that combined spectral tuning of fluorescence and two-photon absorption (TPA) properties of multipolar chromophores can be achieved by introduction of slight electronic chemical dissymmetry. In that perspective, two novel series of structurally related chromophores have been designed and studied: a first series based on rod-like quadrupolar chromophores bearing different electron-donating (D) end groups and a second series based on three-branched octupolar chromophores built from a trigonal donating moiety and bearing various acceptor (A) peripheral groups. The influence of the electronic dissymmetry is investigated by combined experimental and theoretical studies of the linear and nonlinear optical properties of dissymmetric chromophores compared to their symmetrical counterparts. In both types of systems (i.e. quadrupoles and octupoles) experiments and theory reveal that excitation is essentially delocalized and that excitation involves synchronized charge redistribution between the different D and A moieties within the multipolar structure (i.e. concerted intramolecular charge transfer). In contrast, the emission stems only from a particular dipolar subunit bearing the strongest D or A moieties due to fast excitation localization after excitation prior to emission. Hence control of emission characteristics (polarization and emission spectrum) in addition to localization can be achieved by controlled introduction of electronic dissymmetry (i.e. replacement of one of the D or A end-groups by a slightly stronger D{prime} or A{prime} units). Interestingly dissymmetrical functionalization of both quadrupolar and octupolar compounds does not lead to significant loss in TPA responses and can even be beneficial due to the spectral broadening and peak position tuning that it allows. This study thus reveals an original molecular engineering route strategy allowing major TPA enhancement in multipolar structures due to concerted multidimensional ICT while providing for spatial control of emission localization. Such route could be extended to more intricate (dendritic) and multipolar systems (3D).

74 ATOMIC AND MOLECULAR PHYSICS↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of high-speed, species-specific chemiluminescence imaging for laminar flame speed and Markstein length measurements in spherically expanding flames

A high-speed chemiluminescence imaging diagnostic system has been developed and characterized for measuring species-specific properties of spherically expanding flames, with the objective of obtaining synchronized measurements of multiple flame properties from a single flame experiment. The imaging system comprises a high-speed camera coupled to a high-speed image intensifier and optical filters to isolate emission from desired excited species. Here this study validates the diagnostic scheme specifically for measuring laminar flame speed and Markstein length from chemiluminescence at three wavelength bands corresponding to OH*, CH*, and total chemiluminescence, respectively. Mixtures of methane-air and methane/ethane-air were tested at initial conditions of atmospheric pressure and room temperature. An under-utilized methodology for computing unburned Markstein length from burned Markstein length was implemented. Flame speed modeling of each mixture was conducted in Chemkin using AramcoMech 2.0. No significant differences were observed between the results derived from the three emission wavelength bands for the flame speeds nor the Markstein lengths. For both of these properties, excellent agreement was observed between the experimental results and the values reported in the literature. Because laminar flame speed and Markstein length show no dependency on the imaging wavelength, the present results imply that multiple flame properties, such as laminar flame speed, Markstein length, flame thickness, and excited-species intensity profiles, can all be acquired simultaneously for the same flame using this method.

42 ENGINEERING↗

Advanced architectures for high-performance quantum networking

As practical quantum networks prepare to serve an ever-expanding number of nodes, there has grown a need for advanced auxiliary classical systems that support the quantum protocols and maintain compatibility with the existing fiber-optic infrastructure. We propose and demonstrate a quantum local area network design that addresses current deployment limitations in timing and security in a scalable fashion using commercial off-the-shelf components. First, we employ White Rabbit switches to synchronize three remote nodes with ultra-low timing jitter, significantly increasing the fidelities of the distributed entangled states over previous work with Global Positioning System clocks. Second, using a parallel quantum key distribution channel, we secure the classical communications needed for instrument control and data management. Therefore, the conventional network that manages our entanglement network is secured using keys generated via an underlying quantum key distribution layer, preserving the integrity of the supporting systems and the relevant data in a future-proof fashion.

97 MATHEMATICS AND COMPUTING↗

Interferometric system for precision imaging of vibrating structures

An optical profiler is modified in a way which allows it to image a MEMS device at various points during the movement of the MEMS device. The light source is synchronized with a desired movement of the MEMS device. The light source produces pulse at each synchronization period. During each pulse, an interferometric measurement is carried out. So long as the pulse is short enough such that the device does not move significantly, a detection of the position of the device can be accurately obtained.

Gutierrez, Roman C.↗

IPHAS J062746.41+014811.3: A DEEPLY ECLIPSING INTERMEDIATE POLAR

We present time-resolved photometry of a cataclysmic variable discovered in the Isaac Newton Telescope Photometric H{alpha} Survey of the northern galactic plane, IPHAS J062746.41+014811.3, and classify the system as the fourth deeply eclipsing intermediate polar known with an orbital period of P {sub orb} = 8.16 hr and a spin period of P {sub spin} = 2210 s. The system shows mild variations of its brightness that appear to be accompanied by a change in the amplitude of the spin modulation at optical wavelengths and a change in the morphology of the eclipse profile. The inferred magnetic moment of the white dwarf is {mu}{sub wd} {approx} (6-7) Multiplication-Sign 10{sup 33} G cm{sup 3}, and in this case IPHAS J062746.41+014811.3 will evolve either into a short-period EX Hya-like intermediate polar with a large P {sub spin}/P{sub orb} ratio or, perhaps more likely, into a synchronized polar. Swift observations show that the system is an ultraviolet and X-ray source, with a hard X-ray spectrum that is consistent with those seen in other intermediate polars. The ultraviolet light curve shows orbital modulation and an eclipse, while the low signal-to-noise ratio X-ray light curve does not show a significant modulation on the spin period. The measured X-ray flux is about an order of magnitude lower than would be expected from scaling by the optical fluxes of well-known X-ray-selected intermediate polars.

79 ASTRONOMY AND ASTROPHYSICS↗

Particle Beam Acceleration Using 3 Petawatt Laser Pulses

The Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) is presently operational at the Gerard Mourou Center for Ultrafast Optical Science (CUOS) at the University of Michigan. ZEUS is a significant upgrade of the previous high power laser systems at CUOS and consists of two beamlines thatoperate in perfect synchronization. The 500 TW beamline became operational in 2023, 2 PW operation started in 2025 and full 3 PW power levels will be available in 2026. It is presently the highest power laser system in the US. In this grant the high field science group at CUOS has leveraged this unique high power laser facility to investigate laser wake field acceleration (LWFA) in ultra-high power laser plasma interactions and have shown how this can scale for future electron–positron colliders at high energy. The dual beam experimental configuration enables flexibility for many frontier experiments in laser-driven acceleration research, in particular, enabling extended channelling/acceleration experiments, positron generation/acceleration experiments and proof-of-principle transverse pumping “dephasingless” electron acceleration experiment and theory. LWFA may be able to miniaturize particle accelerators for high energy physics and also enable new sources of ultrafast, extreme brightness and precise x-rays for a wide variety of applications. In laser wake field acceleration, an electron bunch “surfs” on the electron plasma wave (the “wake field”) generated by the ponderomotive force of an intense laser. The plasma wave has a strong longitudinal electric field that stays in phase with the relativistic driver. A relativistic charged particle may, therefore, remain in phase with the accelerating field over long distances and gain ultra-relativistic energies. The accelerating electric field strength that the plasma wave can support can be many orders of magnitude higher than that of conventional accelerators, which makes laser wakefield acceleration an exciting prospect as an advanced accelerator concept. In this research project we have investigated the scaling of this mechanism to laser powers of 2 PW and have measured the x-ray emission and radio frequency emission resulting from the acceleration process. We have also performed theoretical investigation of mechanisms to scale laser driven accelerators to much higher energy using dephasingless acceleration processes.

43 PARTICLE ACCELERATORS↗

A geodetic laser radar rangefinder with 10(exp -7) resolution

A novel geodetic laser radar rangefinder (GLRR) unit utilizing a pair of synchronized 10-psec streak camera systems was developed for displacement measurements of the earth's plates. In order to achieve minimum computing error and assure extremely high spatial resolution, an optical pulse registration clock was developed and used to register a fiducial mark on the time scale of the system. Conventional optical rangefinders have been limited to a relative resolution of 10(exp -6) even for short distances. The system to be reported on today has the capability of measuring a 50km range with an accuracy of 4mm corresponding to a relative resolution of 10(exp -7). With a gain of greater than 3 x 10(exp 3), the system has the capability of detecting extremely weak signals on the order of photon counting. This combined with temporal gating makes daytime measurements comparable in signal-to-noise ratio to nighttime viewing. This is useful for measuring faint signals returning over a range of several tens of kilometers. The present ranging system was designed to observe the mutual displacement of geodetic plates and was employed to measure the boundary between the Philippine and Asian geodetic plates that pass beneath the Suruga Bay near Hamamatsu City, Japan. The system has been in operation for over 3 years. In addition, the system has the ability of producing and detecting optical ranging pulses of several wavelengths simultaneously, making this a complete multicolor system. The basic GLRR system consists of a frequency stabilizing crystal, optical clock, YAG laser, KDP doubling crystal, DK*P tripling crystal, two matched streak cameras (A and B), a control computer, and an output/input periscope system.

Mizushima, Y.↗

Synchronization System for Next Generation Light Sources

An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

43 PARTICLE ACCELERATORS↗

NASA Tech Briefs, July 2009

Topics covered include: Dual Cryogenic Capacitive Density Sensor; Hail Monitor Sensor; Miniature Six-Axis Load Sensor for Robotic Fingertip; Improved Blackbody Temperature Sensors for a Vacuum Furnace; Wrap-Around Out-the-Window Sensor Fusion System; Wide-Range Temperature Sensors with High-Level Pulse Train Output; Terminal Descent Sensor Simulation; A Robust Mechanical Sensing System for Unmanned Sea Surface Vehicles; Additive for Low-Temperature Operation of Li-(CF)n Cells; Li/CFx Cells Optimized for Low-Temperature Operation; Number Codes Readable by Magnetic-Field-Response Recorders; Determining Locations by Use of Networks of Passive Beacons; Superconducting Hot-Electron Submillimeter-Wave Detector; Large-Aperture Membrane Active Phased-Array Antennas; Optical Injection Locking of a VCSEL in an OEO; Measuring Multiple Resistances Using Single-Point Excitation; Improved-Bandwidth Transimpedance Amplifier; Inter-Symbol Guard Time for Synchronizing Optical PPM; Novel Materials Containing Single-Wall Carbon Nanotubes Wrapped in Polymer Molecules; Light-Curing Adhesive Repair Tapes; Thin-Film Solid Oxide Fuel Cells; Zinc Alloys for the Fabrication of Semiconductor Devices; Small, Lightweight, Collapsible Glove Box; Radial Halbach Magnetic Bearings; Aerial Deployment and Inflation System for Mars Helium Balloons; Steel Primer Chamber Assemblies for Dual Initiated Pyrovalves; Voice Coil Percussive Mechanism Concept for Hammer Drill; Inherently Ducted Propfans and Bi-Props; Silicon Nanowire Growth at Chosen Positions and Orientations; Detecting Airborne Mercury by Use of Gold Nanowires; Detecting Airborne Mercury by Use of Palladium Chloride; Micro Electron MicroProbe and Sample Analyzer; Nanowire Electron Scattering Spectroscopy; Electron-Spin Filters Would Offer Spin Polarization Greater than 1; Subcritical-Water Extraction of Organics from Solid Matrices; A Model for Predicting Thermoelectric Properties of Bi2Te3; Integrated Miniature Arrays of Optical Biomolecule Detectors; A Software Rejuvenation Framework for Distributed Computing; Kurtosis Approach to Solution of a Nonlinear ICA Problem; Robust Software Architecture for Robots; R4SA for Controlling Robots; Bio-Inspired Neural Model for Learning Dynamic Models; Evolutionary Computing Methods for Spectral Retrieval; Monitoring Disasters by Use of Instrumented Robotic Aircraft; Complexity for Survival of Living Systems; Using Drained Spacecraft Propellant Tanks for Habitation; Connecting Node; and Electrolytes for Low-Temperature Operation of Li-CFx Cells.

Source record↗

V1500 Cygni - Discovery of a magnetic nova

Polarimetric observations of V1500 Cygni, the remnant of Nova Cygni 1975, reveal periodic variations of optical circular polarization with semi-amplitudes of about + or - 1.5 pct. Measured over a six-month baseline, the period of variation, 0.137154 + or - 0.000004 days, is 1.8 percent shorter than the stable photometric period, 0.1396129 days, obtained by Patterson (1979), and refined by Kaluzny and Semeniuk (1987). The circular polarization is interpreted as high-harmonic optical cyclotron emission from an accreting, magnetic white dwarf primary. However, the dominant system light and photometric variability are due to the heated companion star. In this picture, the prenova system was a synchronized AM Herculis-type magnetic variable. During the outburst and subsequent dense-wind phase, coupling between the white dwarf and the expanded envelope and the interaction of the orbiting secondary star were responsible for the asynchronism of the current system and the remarkable photometric variations observed in 1975-1976. Other unusual characteristics of Nova Cygni 1975 are also explained by this model.

Stockman, H. S.↗

Validation/Uncertainty Quantification for Large Eddy Simulations of the heat flux in the Tangentially Fired Oxy-Coal Alstom Boiler Simulation Facility

The objective of this task is to produce predictive capability with quantified uncertainty bounds for the heat flux in commercial-scale, tangentially fired, oxy-coal boilers. Validation data came from the Alstom Boiler Simulation Facility (BSF) for tangentially fired, oxy-coal operation. This task brings together experimental data collected under Alstom’s DOE project for measuring oxy-firing performance parameters in the BSF with this University of Utah project for large eddy simulation (LES) and validation/uncertainty quantification (V/UQ). The Utah work includes V/UQ with measurements in the single-burner facility where advanced strategies for O2 injection can be more easily controlled and data more easily obtained. Highlights of the work include: • Simulations of Alstom’s 15 megawatt (MW) BSF, exploring the uncertainty in thermal boundary conditions. A V/UQ analysis showed consistency between experimental results and simulation results, identifying uncertainty bounds on the quantities of interest for this system (Subtask 9.1) • A simulation study of the University of Utah’s oxy-fuel combustor (OFC) focused on heat flux (Subtask 9.2). A V/UQ analysis was used to show consistency between experimental and simulation results. • Measurement of heat flux and temperature with new optical diagnostic techniques and comparison with conventional measurements (Subtask 9.3). Various optical diagnostics systems were created to provide experimental data to the simulation team. The final configuration utilized a mid-wave infrared (MWIR) camera to measure heat flux and temperature, which was synchronized with a high-speed, visible camera to utilize two-color pyrometry to measure temperature and soot concentration. • Collection of heat flux and temperature measurements in the University of Utah’s OFC for use is subtasks 9.2 and 9.3 (Subtask 9.4). Several replicates were carried to better assess the experimental error. Experiments were specifically designed for the generation of high-fidelity data from a turbulent oxy-coal flame for the validation of oxy-coal simulation models. Experiments were also conducted on the OFC to determine heat flux profiles using advanced strategies for O2 injection. This is important when considering retrofit of advanced O2 injection in retrofit configurations.

Smith, P.J.↗