Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Miniature Long-life Space Cryocoolers

TRW has designed, built, and tested a miniature integral Stirling cooler and a miniature pulse tube cooler intended for long-life space application. Both efficient, low-vibration coolers were developed for cooling IR sensors to temperatures as low as 50 K on lightsats. The vibrationally balanced nonwearing design Stirling cooler incorporates clearance seals maintained by flexure springs for both the compressor and the drive displacer. The design achieved its performance goal of 0.25 W at 65 K for an input power to the compressor of 12 W. The cooler recently passed launch vibration tests prior to its entry into an extended life test and its first scheduled flight in 1995. The vibrationally balanced, miniature pulse tube cooler intended for a 10-year long-life space application incorporates a flexure bearing compressor vibrationally balanced by a motor-controlled balancer and a completely passive pulse tube cold head.

Tward, E.↗

Generation of Coherent X-Ray Radiation through Modulation Compression

In this paper, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulator, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of 1 + h{sub b}R{sub 56}{sup a} in phase space, where h{sub b} is the energy bunch length chirp introduced by the laser chirper, R{sub 56}{sup a} is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 attoseconds pulse, 1 nm coherent X-ray radiation using a 60 A electron beam out of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.

43 PARTICLE ACCELERATORS↗

Generation of Coherent X-Ray Radiation Through Modulation Compression

In this letter, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulators, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of 1 + h{sub b}R{sub 56}{sup a} phase space, where h{sub b} is the energy bunch length chirp introduced by the laser chirper, R{sub 56}{sup a} is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 atto-seconds pulse, 1 nm coherent X-ray radiation using a 60 Ampere electron beam out. of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear post-compression to sub-20 fs using a single-stage multipass cell filled with ambient air

Noble gas-filled multipass cells have proven to be very effective in compressing high-energy, hundreds-of-femtoseconds pulses down to tens of femtoseconds. Molecular gases can be an attractive alternative to noble gases since they provide additional Raman nonlinearities that can be much stronger than the electronic Kerr nonlinearity and can therefore enable more spectral broadening and shorter compressed pulses. Air at atmospheric pressure offers molecular gases in their simplest format, with both easy access and no costs for implementing a gas chamber. Here we demonstrate a single-stage, air-filled multipass cell that spectrally broadens 145- μ J, 185-fs pulses with >90% throughput, with a small fraction of the output compressed to sub-20 fs using a prism-pair compressor. The multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

47 OTHER INSTRUMENTATION↗

Measurement of femtosecond dynamics of ultrafast electron beams through terahertz compression and time-stamping

Visualizing ultrafast dynamics at the atomic scale requires time-resolved characterization with femtosecond temporal resolution. For fully relativistic electron bunch probes, existing techniques for single-shot ultrafast electron diffraction (UED) are limited by the achievable electron probe bunch length, charge, and timing jitter. We present the first experimental demonstration of dual-fed THz-driven compression and time-stamping that enables electron probes with improved temporal resolution. This technique utilizes two counter-propagating quasi-single-cycle THz pulses generated from two OH-1 organic crystals coupled into an optimized THz compressor structure. We demonstrate electron bunch compression and time-of-arrival jitter suppression by a factor of 3 paving the way toward unique opportunities for UED time-resolved measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methodology for designing grism stretchers for idler-based optical parametric chirped-pulse-amplification systems

Powerful ultrafast lasers with wavelengths above 1 mm are in demand to create attosecond pulses and ultra-intense laser sources. A promising technology to achieve these laser sources uses the by-product from an optical parametric chirped-pulse amplifier, known as the idler. Compression of the idler to high peak powers requires a grism stretcher and a grating compressor. Grism stretchers have many more design parameters than conventional stretchers, complicating the design process. This paper presents a method for designing a grism stretcher and grating compressor that logically navigates the design process. This method was applied to design a grism stretcher for the optical parametric amplifier line that is under construction at the Laboratory for Laser Energetics to produce a 50-mJ, 115-fs pulse at 1170 nm.

47 OTHER INSTRUMENTATION↗

Generation of multi-color attosecond x-ray radiation through modulation compression

In this paper, we propose a scheme to generate tunable multi-color attosecond coherent x-ray radiation. This scheme uses a modulation compression method to generate a multi-spike prebunched kilo-ampere peak current electron beam from a few tens ampere electron beam out of a linac. Such a beam transporting through a series of undulator radiators and bunch compressors generates multi-color coherent x-ray radiation. As an illustration, we present an example to generate two attosecond pulses with 2.2 nm and 3 nm coherent x-ray radiation wavelength and more than 200 MW peak power using a 50 A 200 nm laser seeded electron beam.

43 PARTICLE ACCELERATORS↗

The Fermilab CMTF cryogenic distribution remote control system

The Cryomodule Test Facility (CMTF) is able to provide the necessary test bed for measuring the performance of Superconducting Radio Frequency (SRF) cavities in a cryomodule (CM). The CMTF have seven 300 KW screw compressors, two liquid helium refrigerators, and two Cryomodule Test Stands (CMTS). CMTS1 is designed for 1.3 GHz cryomodule operating in a pulsed mode (PM) and CMTS2 is for cryomodule operating in Half-Wave (HW) and Continuous Wave (CW) mode. Based on the design requirement, each subsystem has to be far away from each other and be placed in distant locations. Therefore choosing Siemens Process Control System 7-400, DL205 PLC, Synoptic and Fermilab ACNET are the ideal choices for CMTF cryogenic distribution real-time remote control system. This paper presents a method which has been successfully used by many Fermilab distribution cryogenic real-time remote control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact double-pass Raman backscattering amplifier/compressor

The enhancement of stimulated Raman backscattering (SRBS) amplification was demonstrated by introducing a plasma density gradient along the pump and the seed interaction path and by a novel double-pass design. The energy transfer efficiency was significantly improved to a level of 6.4%. The seed pulse was amplified by a factor of more than 20 000 from the input in a 2 mm long plasma, which also exceeded the intensity of the pump pulse by 2 orders of magnitude. This was accompanied by very effective pulse compression, from 500 fs to 90 fs in the first pass measurements and in the second pass down to approximately 50 fs, as it is indicated by the energy-pulse duration relation. Further improvements to the energy transfer efficiency and the SRBS performance by extending the region of resonance is also discussed where a uniform {approx}4 mm long plasma channel for SRBS was generated by using two subsequent laser pulses in an ethane gas jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Testing of a Lightweight, High Efficiency 95 K Cryocooler

Performance data are presented for a flight-like, lightweight, high efficiency pulse tube cryogenic cooler. The cooler has a mass of less than 4.0 kg, and an efficiency of 12 W/W, which is 18% of Carnot at 95 K, nearly double the efficiency of previous cooler designs, The mass of the cooler has been reduced by approximately a factor of three. The design point cooling power is 10 watts at 95 K at a heat rejection temperature of 300 K. The no-load temperature is 45 K. The compressor is built by Hymatic Engineering, UK, and is of a horizontally opposed piston design using flexure bearings. The vertical pulse tube is built by TRW with the heat exchanger or cold block located approximately mid-way along the tube. The final assembly and integration is also performed by TRW. The inertance tube and dead volume are contained within one of the compressor end caps. The cooler was developed by TRW under a joint NASA-DOD program, and has a goal of 10 yr operating lifetime. Potential NASA applications will focus on using coolers of this type in Zero boil off (ZBO) cryogen storage topologies for next generation launch vehicles. Zero boil off systems will feature significant reductions in tank size and Initial Mass to Low Earth Orbit (IMLEO), thereby significantly reducing the cost of access to space, and enabling future missions. The coolers can be used directly in liquid oxygen (LOx) or liquid methane ZBO systems, as shield coolers in liquid hydrogen tanks, or as first stage coolers in two-stage liquid hydrogen (LH2) ZBO cooler systems. Finally, the coolers could find applications in exploration missions where either propellants or breathable oxygen are extracted from the planetary atmosphere using a Sabatier or similar process. The gases could then be liquefied for storage either directly in return vehicle propellant tanks or on the planetary surface. Data presented were taken with the cooler operating in a vacuum of 10 (exp -5) torr, at controlled rejection temperatures from 300 K down to 275 K using a cold water heat exchanger bolted to the cooler. Heat loads were varied between 0.5 W and 15 W by supplying current to a 50 omega resistor mounted on a copper cold plate which was bolted to the cooler cold block. Silicon diodes mounted on both the cold plate and the heat exchanger provided accurate temperature measurement to within plus or minus 0.25 K and plus or minus 0.5 K respectively, up to 100 K with plus or minus 1% accuracy above 100 K. Input power to the compressor was limited to 180 W, corresponding to a maximum stroke of 80%.

Salerno, Lou↗

Tip-Clearance Vortex Characterized With Three-Dimensional Digital Particle Image Velocimetry

An optical measurement technique known as Three-Dimensional Digital Particle Image Velocimetry (3-D DPIV) was used to characterize the tip clearance flow in NASA Glenn Research Center's low-speed axial compressor. 3-D DPIV is a technique in which a stereoscopic imaging system consisting of two cross-correlation cameras is used to record particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Although 3-D DPIV has been used elsewhere, this is the first time it has been used to measure compressor tip clearance flows. In-house modifications of the DPIV system include the use of effective seeding technology and a novel system to perform a priori calibrations at all five measurement planes, greatly reducing facility run time. Computational fluid dynamics predictions, which are used to guide design changes toward improving the efficiency and operating range of turbomachinery, can be verified and improved by comparison with 3-D DPIV measurements of the actual tip clearance flow. This measurement campaign dealt with the characterization of the tip clearance vortex in the first stage of a four-stage axial compressor. The tip clearance vortex is formed in compressors operating with a clearance gap between the moving rotor blade tips and the stationary casing when a leakage flow, forced from the pressure side of the blade over the blade tip, forms a vortical structure on the suction side of the blade. 3-D DPIV is ideally suited to measure the clearance vortex for two reasons: (1) this technique captures the entire blade passage flow at one instant in time, so that wandering of the vortex during the measurement does not smear out velocity gradients in the flow field, and (2) the spanwise component of velocity changes sign across the vortex core, providing a more accurate measurement of the vortex location than was available with previous two-dimensional measurement approaches. These two attributes of the data will enable computational fluid dynamics researchers to validate their predictions to a level of accuracy not previously attainable. In an effort to understand the effects of this flow phenomenon on the operation of the low speed axial compressor, data were acquired at two mass flow coefficients: 0.395 (design operating point) and 0.35 (operating point just above stall). In order to identify the spatial extent, location, and magnitude of the tip clearance vortex for each mass flow condition, data were acquired at five equally spaced spanwise locations, from 90- to 100-percent span. The data presented shows a cross section of the tip clearance vortex at 94-percent span and a mass flow coefficient of 0.395, where the color contours represent the radial velocity component. The blue (flow towards the hub) and red (flow towards the casing) regions illustrate the extent of the tip clearance vortex. The interface between the blue and red regions delineates the location of the vortex core.

John, W. Trevor↗

Quantum control for initiation and detection of explosives

We employ quantum control methods towards detection and quantum controlled initiation (QCI) of energetic materials. Ultrafast pulse shaping of broadband Infrared ({approx}750 nm to 850 run) and ultraviolet (266 nm, 400 nm) light is utilized for control. The underlying principals behind optimal control can be utilized to both detect and initiate explosives. In each case, time dependent phase shaped electric fields drive the chemical systems towards a desired state. For optimal dynamic detection of explosives (ODD-Ex) a phase specific broadband infrared pulse is created which increases not only the sensitivity of detection but also the selectivity of an explosive's spectral signatures in a background of interferents. QCI on the other hand, seeks to initiate explosives by employing shaped ultraviolet light. QCI is ideal for use with explosive detonators as it removes the possibility of unintentional initiation from an electrical source while adding an additional safety feature, initiation only with the proper pulse shape. Quantum control experiments require: (1) the ability to phase and amplitude shape the laser pulse and (2) the ability to effectively search for the pulse shape which controls the reaction. In these adaptive experiments we utilize both global and local optimization search routines such as genetic algorithm, differential evolution, and downhill simplex. Pulse shaping the broadband IR light, produced by focusing 800 nm light through a pressurized tube of Argon, is straightforward as commercial pulse shapers are available at and around 800 nm. Pulse shaping in the UV requires a home built shaper. Our system is an acoustic optical modulator (AOM) pulse shaper in which consists of a fused silica AOM crystal placed in the Fourier plane of a 4-f zero dispersion compressor.

66↗

LLE Review Volume 124 (July-September 2010)

This volume of the LLE Review, covering July–September 2010, features “Grating Inspection System for Large-Scale Multilayer-Dielectric Gratings for High-Energy Laser Systems” by T. Nguyen, C. Kingsley, J. Bunkenburg, A. Kalb, M. Bedzyk, D. Weiner, T. Walker, and J. R. Marciante. The article (p. 165) reports on the development of a high-resolution inspection system for the detection of laser damage on large-scale (1.41-m # 0.43-m) multilayer diffraction gratings in the OMEGA EP short-pulse laser system. The grating inspection system (GIS) is fully integrated within the vacuum grating compressor and enables inspections to be carried out while the compressor chamber is under vacuum. Damage is detected by imaging scattered light from damage sites on the grating surface. Features as small as 250 nm can be identified with the system.

36 MATERIALS SCIENCE↗

Energy stores and switches for rail-launcher systems

An overview of existing switch and power supply technology applicable to space launch, a new candidate pulsed power supply for Earth-to-space rail launcher duty, the inverse railgun flux compressor, and a set of switching experiments to study further the feasibility of Earth-to-space launch are discussed.

Weldon, W. F.↗

Design and Testing of Demonstration Unit for Maintaining Zero Cryogenic Propellant Boiloff

Launching of cryogenic propellants into earth orbit and beyond is very expensive. Each additional pound of payload delivered to low earth orbit requires approximately 35 pounds of additional weight at liftoff. There is therefore a critical need to minimize boiloff in spacecraft long term missions/systems. Various methods have been used to date, including superinsulation and thermodynamic vents to reduce boiloff. A system was designed and tested as described herein that will totally eliminate boiloff. This system is based on a closed-loop, two-stage pulse tube refrigerator with a net refrigeration of four watts at 15k for the recovery of hydrogen propellant. It is designed to operate at 30 Hz which is an order of magnitude higher than other typical pulse tube refrigerators. This high frequency allows the use of a much smaller, lighter weight compressor, This paper describes the system design, fabrication and test results.

Dean, W. G.↗

Report on High-Contrast Advanced Radiographic Capability Review

The Advanced Radiographic Capability (ARC) project at the National Ignition Facility (NIF) is designed to generate picosecond duration, kilo-Joule laser pulses to produce xrays for backlighting NIF experiments. The baseline concept (Figure 1), utilizing a single NIF beam quad, diverts the beamline(s) using insertable pick-off mirrors to a compressor chamber in the target bay and focuses it to target chamber center. When fully implemented, ARC will use a quad of NIF beamlines to deliver eight Petawatt-class, high-intensity pulses in a split aperture configuration (2 short pulse apertures per NIF beamline). These short pulses will be adjustable in energy (up to 13.2 kJ in full implementation), delays (0-80 ns) and pulse durations (1-50 ps) and can be individually pointed to targets. ARC will enable dynamic, multi-frame x-ray imaging (radiography) on NIF for applications in laser driven fusion and other high-energy density science missions. The near-term missions in support of the SSP program are described below.

42 ENGINEERING↗

Generation of coherent X-ray radiation through modulation compression

In this paper, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulator, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of $1+h_b R_{56}^a$ in phase space, where $h_b$ is the energy bunch length chirp introduced by the laser chirper, $R_{56}^a$ is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 attoseconds pulse, 1 nm coherent X-ray radiation using a 60 Ampere electron beam out of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.

Instruments & Instrumentation↗