Results for “radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Multiple VIIRS Sensors Over Tropical Earth Views

The NASA CERES project provides Energy Balanced and Filled (EBAF) product climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 satellites. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua- MODIS reference to retrieve consistent imager cloud properties between sensors, which are used to retrieve cloud properties required for converting CERES radiance observations into fluxes. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun- synchronous orbit but spaced equally apart, which means that no simultaneous nadir overpasses (SNO) may be used to inter-calibrate the VIIRS imagers to each one another. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua-MODIS can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between either MODIS and or VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers and is especially suited for drifting orbits because EPIC imager frequently samples the Earth diurnally. The study will demonstrate the use of EPIC as a transfer radiometer to radiometrically scale the NPP and NOAA-20 VIIRS imagers. The scaling factors will be compared with the scaling factors using Aqua-MODIS as the transfer radiometer.

Conor Haney↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗

Classifying Microwave Radiometer Observations Over the Netherlands Into Dry, Shallow-, and Non-Shallow Precipitation Using A Random Forest Model

Spaceborne microwave radiometers represent an important component of the Global Precipitation Measurement (GPM) mission due to their frequent sampling of rain systems. Microwave radiometers measure microwave radiation (brightness temperatures, Tb), which can be converted into precipitation estimates with appropriate assumptions. However, detecting shallow precipitation systems using space-borne radiometers is challenging, especially over land, as their weak signals are hard to differentiate from those associated with dry conditions. This study uses a random forest model (RF) to classify microwave radiometer observations as dry, shallow, or nonshallow over the Netherlands - a region with varying surface conditions and frequent occurrence of shallow precipitation. The RF is trained on five years of data (2016-2020) and tested with two independent years (2015, 2021). The observations are classified using ground-based weather radar echo top heights. Various RF models are assessed, such as using only GPM’s Microwave Imager (GMI) Tb values as input features or including spatially aligned ERA-5 2-meter temperature and freezing level reanalysis and/or Dual Precipitation Radar (DPR) observations. Independent of the input features, the model performs best in summer and worst in winter. The model classifies observations from high-frequency channels (≥85 GHz) with lower Tb-values as non-shallow, higher values as dry, and those in between as shallow. Misclassified footprints exhibit radiometric characteristics corresponding to their assigned class. Case studies reveal dry observations misclassified as shallow are associated with lower Tb-values, likely resulting from the presence of ice particles in non-precipitating clouds. Shallow footprints misclassified as dry are likely related to the absence of ice particles.

Linda Bogerd↗

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using Multiple LEO Radiometers

The first five years of operation of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange one point have produced results that uniquely complement the data from currently operating low orbit Earth-observing instruments. In this paper we describe an updated unified approach to EPIC calibration. In this approach, calibration coefficients and their trends were obtained by comparing EPIC observations to the measurements from polar orbiting radiometers. In this study L1B reflectances from Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua and Terra satellites, Multi-angle Imaging Spectroradiometer (MISR) onboard Terra and Visible Infrared Imaging Radiometer (VIIRS) onboard the Suomi National Polar-orbiting Partnership (Suomi NPP) spacecraft were used to infer calibration coefficients for four EPIC visible and near-infrared channels: 443 nm, 551 nm, 680 nm, and 780 nm. EPIC Version three measurements made between June 2015 and August 2020 were used for comparison. The calibration procedure identifies the most homogeneous low Earth orbit radiometer scenes matching scattering angles that are temporarily and spatially collocated with EPIC observations. These scenes are used to determine reflectance to count (R/C) ratios in spectrally analogous channels. Seasonal average R/C ratios were analyzed to obtain EPIC calibration gains and trends. The trends for the full dataset period are not statistically significant except in the 443 nm channel. No significant changes in calibration were found after the instrument’s exit from safe hold in March 2020. The R/C ratios were also used to determine the differences in EPIC gains resulting from separate calibrations: against MODIS Aqua or Terra, as well as against forward or aftward MISR cameras. Statistical tests indicate that the differences between the two datasets are not significant except in the 780 nm channels where Aqua-derived coefficients may be around 2% lower compared to Terra. The dependence of EPIC calibration gains on the instrument scattering angle and on DSCOVR-Earth distance were investigated. Lastly, model Low Earth Orbit (LEO) reflectances calculated to match the EPIC viewing geometry were employed to study how EPIC calibration coefficients depend on EPIC-LEO viewing geometry differences. The effect of LEO and EPIC angular mismatch on calibration was shown to be small.

deep space climate observatory/earth polychromatic↗

Microwave radiometer and scatterometer design for the aquarius sea surface Salinity Mission

The measurement of sea surface salinity with L-band microwave radiometers is a very challenging task. Since the L-band brightness temperature variations associated with salinity changes are small, it is necessary to have a very sensitive and stable radiometer. In addition, the corrections for the ocean surface roughness require real time scatterometer measurements. The designs of the Aquarius radiometer and scatterometer are described in this paper.

sea surface salinity↗

Radio Frequency Interference Mitigation for the Planned SMAP Radar and Radiometer

NASA's planned SMAP mission will utilize a radar operating in a band centered on 1.26 GHz and a co-observing radiometer operating at 1.41 GHz to measure surface soil moisture. Both the radar and radiometer sub-systems are susceptible to radio frequency interference (RFI). Any significant impact of such interference requires mitigation in order to avoid degradation in the SMAP science products. Studies of RFT detection and mitigation methods for both the radar and radiometer are continuing in order to assess the risk to mission products and to refine the performance achieved.

radiometer↗

Imager-to-Radiometer In-flight Cross Calibration: RSP Radiometric Comparison with Airborne and Satellite Sensors

This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

calibrating↗

Tracking Radiometer Calibration Stability Using Three-Point Onboard Calibration

Absolute calibration of radiometers is implemented onboard using one hot and one cold external calibration targets. However, two-point calibration methods are unable to differentiate calibration drifts and associated errors from fluctuations in receiver gain and offset. This paper investigates the use of onboard three-point calibration algorithm for microwave radiometers to track calibration drifts and characterize associated errors in Earth and Space measurements of the radiometer.

Calibration↗

Development of a satellite microwave radiometer to sense the surface temperature of the world oceans

A proposed S-band radiometer for determining the ocean surface temperature with an absolute accuracy of + or - 1 Kelvin and a resolution of + or - .1 Kelvin was placed under the Advanced Applications Flight Experiment for further development into Nimbus readiness state. The results of assessing the following are described: effects due to the state of the sea surface, effects caused by the intervening atmosphere, and effects associated with imperfections in the instrument itself. An extensive sea truth program is also described for correlation of aircraft test flight measurements or of satellite remote measurement to in-situ data. An improved radiometer design is a modified Dicke-switch type with temperature stabilized, microwave integrated circuit, front-end and with a pulsed injection-noise nulling system. The radiometer has a multimode rectangular horn antenna with very low ohmic losses and a beam efficiency of 98% or better.

Hidy, G. M.↗

Studies with satellite radiometer data

The application of satellite radiometer data for analyzing and predicting global winds is discussed. The data obtained from the vertical temperature profile radiometer of the ITOS D satellite are described. The development of a nine level model for analyzing the physical properties of radiative transfer and cloud effects in the atmosphere is presented. Comparisons are made between various methods of applying the satellite radiometer data.

Halem, M.↗

High performance S-band horn antennas for radiometer use

Horn antennas of four types: pyramidal corrugated, conical corrugated, pyramidal dual mode and conical dual mode, have been constructed and evaluated for use as S-band radiometer antennas. Each of the structures is described and radiation patterns and impedance and resistive loss measurements including a layer of foreign material on a thin radome, are presented. A precision method for determining reflection losses is described using a multiprobe reflectometer technique. The same technique is also applied to the measurement of resistive losses by closing the ends of the antennas with short circuit plates and determining the losses from an accurate measurement of the reflection coefficient. The radiation patterns were recorded with the aid of a real-time digital computer. The stored patterns were then processed to yield gain and beam efficiency. It was concluded that it is possible to design a highly efficient antenna for radiometer use and to measure its parameters precisely. However, it was found that it is necessary to modify the conventional definition of beamwidth somewhat if this term is to be meaningful for radiometer applications.

Caldecott, R.↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

Correcting airborne scanning infrared radiometer measurements for atmospheric effects

Two techniques were developed for determining atmospheric corrections from observations made by a scanning radiometer. Both techniques depend on knowing the radiometer's limb function. The limb function for an RS-18 scanning radiometer is derived from calculations made with a radiation model and used to demonstrate the techniques. One technique requires observations made over an isothermal water surface within the area being remotely sensed. The other technique does not depend on an isothermal water surface but requires a boat measurement of radiometric sea surface temperature within the area being remotely sensed. The radiation model used to derive the limb function does not account for the effects of atmospheric particulates on the correction. It is hypothesized that the effect of particulates on the limb function derived in this study is negligible, and therefore the technique essentially obtains the total correction. The techniques developed can be used over land provided that a section of isothermal land exists within the experiment area or that a radiometric measurement of surface temperature is made at the surface.

Boudreau, R. D.↗

Dual frequency microwave radiometer measurements of soil moisture for bare and vegetated rough surfaces

Controlled ground-based passive microwave radiometric measurements on soil moisture were conducted to determine the effects of terrain surface roughness and vegetation on microwave emission. Theoretical predictions were compared with the experimental results and with some recent airborne radiometric measurements. The relationship of soil moisture to the permittivity for the soil was obtained in the laboratory. A dual frequency radiometer, 1.41356 GHz and 10.69 GHz, took measurements at angles between 0 and 50 degrees from an altitude of about fifty feet. Distinct surface roughnesses were studied. With the roughness undisturbed, oats were later planted and vegetated and bare field measurements were compared. The 1.4 GHz radiometer was less affected than the 10.6 GHz radiometer, which under vegetated conditions was incapable of detecting soil moisture. The bare surface theoretical model was inadequate, although the vegetation model appeared to be valid. Moisture parameters to correlate apparent temperature with soil moisture were compared.

Lee, S. L.↗

Remote sensing of soil moisture with microwave radiometers

Microwave radiometry has been used for the remote sensing of soil moisture in a series of aircraft flights over an agricultural test area in the vicinity of Phoenix, Arizona. The radiometers covered the wavelength range 0.8-21 cm. Ground truth in the form of gravimetric measurements of the soil moisture in the top 15 cm were obtained for 200 fields at this site. The results indicate that it is possible to monitor moisture variations with airborne radiometers. The emission is a function of the radiometer wavelength and the distribution of the moisture in the soil. At a wavelength of 1.55 cm there is little or no variation in the emission for soil moisture values below 10 or 15% moisture content by weight. Above this value, there is a linear decrease in the emission with a slope of approximately 3 K for each percentage point increase in soil moisture.

Schmugge, T.↗