Search NASA⌕ Search

SEARCH · Search NASA

Results for “readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

THE STRUCTURE FUNCTION OF THE FREE NEUTRON AT HIGH X-BJORKEN

Understanding the internal structure of nucleons is one of the primary goal of nuclear physicists. As protons and neutrons are only the bound state solution of the QCD lagrangian (at least inside atomic nuclei), studying protons and neutrons helps uncover nuclear struc ture. Due to its easy availability, many studies on protons have been done on a wide range of kinematics. However, free neutron targets are not readily achievable. So, any information on neutrons has to be extracted from neutron-rich nuclei, and some nuclear models have to be used to subtract the contributions from other nucleons to extract the information on neutrons. So, the Barely Off-shell Nucleon Structure (BONuS12) experiment at Jefferson Lab was conducted to overcome these challenges by using spectator tagging. The experiment effectively created a quasi-free neutron target by scattering electrons off a deuterium target and detecting low-momentum, backward-moving protons using a custom-built Radial Time Projection Chamber (RTPC). Selecting the low momentum and backward-moving spectators would enable us to minimize the model-dependent effects due to final state interactions and target fragmentation. The RTPC was a 40 cm-long cylindrical detector that works on the principle of gaseous ionization. It had three layers of Gas Electron Multipliers (GEMs) for charge amplification and a surrounding readout pad. The scattered electrons were measured using the CLAS12 detector, and data were collected using a 10.4 GeV electron beam dur ing Spring and Summer 2020. Using spectator tagging, we extracted the structure function ratio Fn 2 of the quasi-free neutron in the deep inelastic scattering at high x, upto x ~ 0.8. The result was extracted in the region with the invariant mass W > 1.8 GeV/c2, and Q2 in the range 1.3 to 11 GeV2. This dissertation presents the methodology, event selection criteria and refinements, estimation and subtraction of backgrounds, and complete analysis of extraction of Fn 2/Fp 2 in a model-independent way. Also, systematic uncertainties in our final analysis will be discussed in detail.

Pokhrel, Madhusudhan [Old Dominion Univ., Norfolk,↗

Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS

Single electron spin qubits trapped in SiMOS quantum dots are a promising technology for scaling to thousand- or million-qubit systems due to their compatibility with mature CMOS manufacturing processes. A readout system that combines a single electron transistor with a custom cryogenic CMOS amplification and digitization chain offers key advantages by avoiding the use of bulky RF components or room-temperature interconnects. We present design techniques and simulation results for an optimized qubit-SET cryoCMOS interface, culminating in the design of the QNDR1 ASIC, the first cryogenic readout ASIC designed under the Quandarum project, which targets the development of a many-channel spin qubit based detector for use in high energy physics.

Quinn, Adam [Fermilab] (ORCID:0009000605056371)↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Barrel Calorimeter Processor demonstrator (BCPv1) board evaluation

For the CERN LHC phase 2, the barrel region of the CMS electromagnetic (ECAL EB) and hadronic calorimeters (HCAL HB) require new back-end electronics for their readout. To this purpose, a first version of the ATCA-based blade, the Barrel Calorimeter Processor (BCPv1), has been developed. The performance of the optical links as well as clock distribution are also presented here. Here, the BCPv1 has been tested together with front-end and trigger boards, as well as with the new DAQ and TCDS Hub (DTH) [1], to demonstrate that the BCPv1 meets the required specifications.

47 OTHER INSTRUMENTATION↗

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

Feasibility study of quantum computing using trapped electrons

In this study, we investigate the feasibility of using electrons in a linear Paul trap as qubits in a future quantum computer. We discuss the necessary experimental steps to realize such a device through a concrete design proposal, including trapping, cooling, electronic detection, spin readout, and single- and multiqubit gate operations. Numeric simulations indicate that two-qubit Bell-state fidelities of order 99.99% can be achieved assuming reasonable experimental parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

MaPSA Quality Control and AI-Enhanced Grading For the CMS Phase-II Tracker Upgrade

The Compact Muon Solenoid (CMS) experiment will undergo changes as part of the Large Hadron Collider upgrade. The CMS tracker will be upgraded to cope with the new radiation environment and to provide tracking at the first level trigger. This upgrade features a new type of silicon module called PS Module, which combines a Pixel sensor and a Strip sensor in the same module. The pixel portion of the PS module has a sensor bump bonded to 16 Macro Pixel ASICs (MPA) to form a Macro Pixel Sub Assembly (MaPSA). At Fermilab, MaPSAs are tested for quality control before being assembled with the strip sensors, readout and service electronics to form a PS Module. All of this test data is stored in a centralized database, and is used to grade the final module to determine if it will be installed in the detector. The Phase II Outer Tracker Analyzer of Test Outputs (POTATO) is the software that processes this data and determines the module grades. Using recent technologies, an AI agent is being im plemented into POTATO in order to allow users to more efficiently sort through the large amounts of analysis data and ensure that only the user specified data is being considered. This poster will display the process of testing a MaPSA, how that test data is relevant to module assembly and grading, and how the POTATO grading tool is being improved with the use of an embedded AI agent.

Gzamouranis, Olivia [Purdue U.]↗

Upgrades of the ATLAS Zero Degree Calorimeter System for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1 were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with $\text{H}_2$-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new "Reaction Plane Detectors" (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run~3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run~3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗