Search NASA⌕ Search

SEARCH · Search NASA

Results for “retina”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Light flash phenomena induced by HzE particles

Astronauts and Apollo and Skylab missions have reported observing a variety of visual phenomena when their eyes are closed and adapted to darkness. These phenomena have been collectively labelled as light flashes. Visual phenomena which are similar in appearance to those observed in space have been demonstrated at the number of accelerator facilities by expressing the eyes of human subjects to beams of various types of radiation. In some laboratory experiments Cerenkov radiation was found to be the basis for the flashes observed while in other experiments Cerenkov radiation could apparently be ruled out. Experiments that differentiate between Cerenkov radiation and other possible mechanisms for inducing visual phenomena was then compared. The phenomena obtained in the presence and absence of Cerenkov radiation were designed and conducted. A new mechanism proposed to explain the visual phenomena observed by Skylab astronauts as they passed through the South Atlantic Anomaly, namely nuclear interactions in and near the sensitive layer of the retina, is covered. Also some studies to search for similar transient effects of space radiation on sensors and microcomputer memories are described.

Mcnulty, P. J.↗

Late degeneration in rabbit tissues after irradiation by heavy ions

Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

Lett, J. T.↗

Veiling glare reduction methods compared for ophthalmic applications

Veiling glare in ocular viewing was simulated by viewing the retina of an eye model through a sheet of light-scattering material lit from the front. Four methods of glare reduction were compared, namely, optical scanning, polarized light, viewing and illumination paths either coaxial or intersecting at the object, and closed circuit TV. Photographs show the effect of these methods on visibility. Polarized light was required to eliminate light specularly reflected from the instrument optics. The greatest glare reduction was obtained when the first three methods were utilized together. Glare reduction using TV was limited by nonuniform distribution of scattered light over the image.

Buchele, D. R.↗

A single-channel model does not predict visibility of asynchronous gratings

A single channel model is shown to lack the capability to predict the visibility of asynchronous compound gratings. A constant Beta was assumed, based on Monte-Carlo simulations, and used to show that an SE of 6.73 (Limb, 1981) lies outside of an acceptable confidence interval. Potential imbalances between two eyes cannot be as large as 1.5 dB, which can only affect one eye, or one region of a retina. An average unbalance of 0.53 dB (SE = 0.12) employed in experiments to measure thresholds was compensated for by estimated threshold reductions. Trial-to-trial variability was included in the single channel model, as were considerations of retinal inhomogeneity. Temporal sensitivity for 2 and 4 c/deg grating patches were measured, and the amplitude response of a single channel at the two spatial frequencies was obtained. Threshold reductions with a Beta of 3.1 are then determined to not be significant enough to warrant adoption of the single channel model predictions.

Watson, A. B.↗

Vision Screening by Color Photography

Screening test developed for detecting a range of vision defects in eye, including common precursors to amblyopia. Test noninvasive, safe, and administered easily in field by operator with no medical training. Only minimal momentary cooperation of subject required: Thus, test shows promise for use with very young children. Test produces color-slide images of retinas of eyes under specially-controlled lighting conditions. Trained observer screens five children per minute.

Jayroe, R.↗

Cell Death, Neuronal Plasticity and Functional Loading in the Development of the Central Nervous System

Research on the precise timing and regulation of neuron production and maturation in the vestibular and visual systems of Wistar rats and several inbred strains of mice (C57B16 and Pallid mutant) concentrated upon establishing a timing baseline for mitotic development of the neurons of the vestibular nuclei and the peripheral vestibular sensory structures (maculae, cristae). This involved studies of the timing and site of neuronal cell birth and preliminary studies of neuronal cell death in both central and peripheral elements of the mammalian vestibular system. Studies on neuronal generation and maturation in the retina were recently added to provide a mechanism for more properly defining the in utero' developmental age of the individual fetal subject and to closely monitor potential transplacental effects of environmentally stressed maternal systems. Information is given on current efforts concentrating upon the (1) perinatal period of development (E18 thru P14) and (2) the role of cell death in response to variation in the functional loading of the vestibular and proprioreceptive systems in developing mammalian organisms.

Keefe, J. R.↗

Reduction of display artifacts by random sampling

The application of random-sampling techniques to remove visible artifacts (such as flicker, moire patterns, and paradoxical motion) introduced in TV-type displays by discrete sequential scanning is discussed and demonstrated. Sequential-scanning artifacts are described; the window of visibility defined in spatiotemporal frequency space by Watson and Ahumada (1982 and 1983) and Watson et al. (1983) is explained; the basic principles of random sampling are reviewed and illustrated by the case of the human retina; and it is proposed that the sampling artifacts can be replaced by random noise, which can then be shifted to frequency-space regions outside the window of visibility. Vertical sequential, single-random-sequence, and continuously renewed random-sequence plotting displays generating 128 points at update rates up to 130 Hz are applied to images of stationary and moving lines, and best results are obtained with the single random sequence for the stationary lines and with the renewed random sequence for the moving lines.

Ahumada, A. J., Jr.↗

Neurophysiological model of the normal and abnormal human pupil

Anatomical, experimental, and computer simulation studies were used to determine the structure of the neurophysiological model of the pupil size control system. The computer simulation of this model demonstrates the role played by each of the elements in the neurological pathways influencing the size of the pupil. Simulations of the effect of drugs and common abnormalities in the system help to illustrate the workings of the pathways and processes involved. The simulation program allows the user to select pupil condition (normal or an abnormality), specific site along the neurological pathway (retina, hypothalamus, etc.) drug class input (barbiturate, narcotic, etc.), stimulus/response mode, display mode, stimulus type and input waveform, stimulus or background intensity and frequency, the input and output conditions, and the response at the neuroanatomical site. The model can be used as a teaching aid or as a tool for testing hypotheses regarding the system.

Krenz, W.↗

Cone sampling array models

A model is described for positioning cones in the retina. Each cone has a circular disk of influence, and the disks are tightly packed outward from the center. This model has three parameters that can vary with eccentricity: the mean radius of the cone disk, the standard deviation of the cone disk radius, and the standard deviation of postpacking jitter. Estimates for these parameters out to 1.6 deg are found by using measurements reported by Hirsch and Hylton (1985) and Hirsch and Miller (1987) of the positions of the cone inner segments of an adult macaque. The estimation is based on fitting measures of variation in local intercone distances, and the fit to these measures is good.

Ahumada, Albert J., Jr.↗

Implications of otoconial changes in microgravity

Otoconia of maculas of Sprague-Dawley rats (Taconic Farms) flown aboard Spacelab-3 showed no signs of demineralization. Other findings were accumulations of miniature otoconia at the lateral border of utricular patches and a smoothing of surfaces of saccular otoconia. These features were not observed in age- and weight-matched ground controls. Subsequent study showed otoconial asymmetry to be normal in this strain. Further research in space, taking this into account, is clearly required. Findings of ground-based studies would suggest that neural structures of maculas are adaptable to microgravity but might show changes over time. Moreover, maculas have the potential for integration of the sort ascribed to brain and retina, although on a less complex scale. They may act as comparators, and asymmetry may be an important property. Coordinated studies in space and on the ground could lead to new understanding of how maculas function and adapt to new acceleratory environments; and to insights about the functioning of neural tissue in general.

Ross, Muriel D.↗

Simulated annealing in networks for computing possible arrangements for red and green cones

Attention is given to network models in which each of the cones of the retina is given a provisional color at random, and then the cones are allowed to determine the colors of their neighbors through an iterative process. A symmetric-structure spin-glass model has allowed arrays to be generated from completely random arrangements of red and green to arrays with approximately as much disorder as the parafoveal cones. Simulated annealing has also been added to the process in an attempt to generate color arrangements with greater regularity and hence more revealing moirepatterns than than the arrangements yielded by quenched spin-glass processes. Attention is given to the perceptual implications of these results.

Ahumada, Albert J., Jr.↗

Some examples of image warping for low vision prosthesis

NASA has developed an image processor, the Programmable Remapper, for certain functions in machine vision. The Remapper performs a highly arbitrary geometric warping of an image at video rate. It might ultimately be shrunk to a size and cost that could allow its use in a low-vision prosthesis. Coordinate warpings have been developed for retinitis pigmentosa (tunnel vision) and for maculapathy (loss of central field) that are intended to make best use of the patient's remaining viable retina. The rationales and mathematics are presented for some warpings that we will try in clinical studies using the Remapper's prototype.

Juday, Richard D.↗

Microlesions - Theory and reality

Efforts to assess radiation risk in space have been complicated by the considerable unknowns regarding the biological effects of the heavy ion component (HZE particles) of the cosmic rays. The attention has focused primarily on the assignation of a quality factor (Q) which would take into account the greater effectiveness of heavy ions vis-a-vis other forms of ionizing radiation. If, however, as the so-called 'microlesion theory' allows, the passage of HZE particles through living tissue produces unique biological damage, the traditional use of Q becomes meaningless. Therefore, it is critical to determine if microlesions, in fact, do exist. While the concept does not necessarily require detectable morphological damage, 'tunnel-lesions' or holes in ocular tissues have been cited as evidence of microlesions. These data, however, are open to reinterpretation. Ongoing light, scanning and transmission electron microscopic studies of the corneas, lenses and retinas of rat eyes exposed to 450 MeV/amu Fe-56 ions thus far have not revealed tunnel-lesion damage. The morphological effects of the heavy ions have been found to be qualitatively similar to the changes following other kinds of ionizing radiation.

Worgul, Basil V.↗

Programmable Remapper

Input image remapped rapidly and accurately onto different coordinate grid. Analog/digital electronic image-processing system developed to warp input images onto arbitrary coordinate grids at video rates. Advantages of system include antialiasing effect of many-to-one data path and speed of lookup-table operation. Lookup tables reprogrammed easily with help of computer that generates table values from mathematical description of desired transformation. Applications include real-time corrections of distortions in input optics of image sensors, corrections for repeatable nonlinear scanning, and aiding persons of impaired vision by deliberately distorting images onto remaining functional portions of retinas.

Juday, Richard D.↗

A3I visibility modeling project

The Army-NASA Aircrew Aircraft Integration program is supporting a joint project to build a visibility computer-aided design (CAD) tool. CAD has become an essential tool in modern engineering applications. CAD tools are used to create engineering drawings and to evaluate potential designs before they are physically realized. The visibility CAD tool will provide the design engineer with a tool to aid in the location and specification of windows, displays, and control in crewstations. In an aircraft cockpit the location of instruments and the emissive and reflective characteristics of the surfaces must be determined to assure adequate aircrew performance. The visibility CAD tool will allow the designer to ask and answer many of these questions in the context of a three-dimensional graphical representation of the cockpit. The graphic representation of the cockpit is a geometrically valid model of the cockpit design. A graphic model of a pilot, called the pilot manikin, can be placed naturalistically in the cockpit model. The visibility tool has the capability of mapping the cockpit surfaces and other objects modeled in this graphic design space onto the simulated pilot's retinas for a given visual fixation.

Larimer, James↗

Exocentric direction judgements in computer-generated displays and actual scenes

One of the most remarkable perceptual properties of common experience is that the perceived shapes of known objects are constant despite movements about them which transform their projections on the retina. This perceptual ability is one aspect of shape constancy (Thouless, 1931; Metzger, 1953; Borresen and Lichte, 1962). It requires that the viewer be able to sense and discount his or her relative position and orientation with respect to a viewed object. This discounting of relative position may be derived directly from the ranging information provided from stereopsis, from motion parallax, from vestibularly sensed rotation and translation, or from corollary information associated with voluntary movement. It is argued that: (1) errors in exocentric judgements of the azimuth of a target generated on an electronic perspective display are not viewpoint-independent, but are influenced by the specific geometry of their perspective projection; (2) elimination of binocular conflict by replacing electronic displays with actual scenes eliminates a previously reported equidistance tendency in azimuth error, but the viewpoint dependence remains; (3) the pattern of exocentrically judged azimuth error in real scenes viewed with a viewing direction depressed 22 deg and rotated + or - 22 deg with respect to a reference direction could not be explained by overestimation of the depression angle, i.e., a slant overestimation.

Ellis, Stephen R.↗

Alternative representations of visual space

This paper discusses a method for delineating and testing hypotheses about the relationship between the retinal images and the three-dimensional visual space they serve. The method may be used under the conditions of changing eye position, occlusion by structures that are part of or are mounted on the observer, occlusions by environmental objects, defects of the visual field, and variables that alter the focus of environmental imagery on the retinas.

Arditi, Aries↗

Reconstructing irregularly sampled images by neural networks

Neural-network-like models of receptor position learning and interpolation function learning are being developed as models of how the human nervous system might handle the problems of keeping track of the receptor positions and interpolating the image between receptors. These models may also be of interest to designers of image processing systems desiring the advantages of a retina-like image sampling array.

Ahumada, Albert J., Jr.↗