Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar power integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

AN UPDATE ON THE STATUS OF A REDUCED FLOW TEST OF A 10MW 700⁰C SCO2 INTEGRALLY GEARED COMPANDER

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700℃. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale CSP supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally-geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications.

14 SOLAR ENERGY↗

PV-BESS DC-Series Integration for Regulated DC Systems

DC-series integration introduces a novel approach to seamlessly integrate a solar photovoltaic (PV) array and a battery energy storage (BES) in series. This system, referred to as the PV-integrated battery energy storage system—dc series (PVBESS-DCS), simplifies integration and enhances power density by leveraging the inherent voltage-source characteristics of batteries and adopting the concept of partial power processing. However, addressing voltage variations of a PV array and a BES under different operational conditions remains a challenge to apply the PVBESS-DCS to a regulated dc system, where the dc-bus voltage is fixed. This article proposes a PVBESS-DCS solution tailored for regulated dc systems. Within this framework, we present a controllable series voltage source compensating for the voltage differences between the PV and BES sources and the dc bus. Thus, the system can perform PV maximum power point tracking and curtailment control while charging and discharging BES and connected to a regulated dc bus. Additionally, we present a single-stage multiport partial power processing dc–dc converter designed for the proposed PVBESS-DCS. It utilizes a triple active bridge dc–dc converter topology. Finally, this article presents operating principles, control strategies, simulation results, and experimental findings of the proposed PVBESS-DCS for regulated dc systems.

25 ENERGY STORAGE↗

Sodium Ion Expansion Power Block for Distributed CSP

The Sodium Ion Expansion Power Block for Distributed CSP was a three-plus-one-year effort under the Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities (CSP: APOLLO) funding program within the U.S. Department of Energy Solar Energy Technologies Office. The primary objective of this project is to develop a dual-stage modular sodium thermal electrochemical converter (Na-TEC) heat engine power block, which can be potentially integrated with either a small-scale dish solar or large-scale heliostats and parabolic trough CSP. Na-TEC is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K –1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. In light of this, we first designed and developed a thermo-electrochemical model, and thermodynamically demonstrated how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also established an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Moreover, a thermal design of an axisymmetric dual-stage Na-TEC is developed to guide the scale-up and fabrication of sub-components of prototype module. A reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model that was developed to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved. Ultimately, we were able to demonstrate thermal efficiency improvements of the Na-TEC heat engine from 19% up to 40.3%, in a dual-stage (non-optimized) prototype module that we designed, fabricated, and tested with high temperature stage at 923 K. Furthermore, a cost-performance analysis for this improved dual-stage design was carried out for distributed-CSP systems. A high-level techno-economic analysis (TEA) explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per We are feasible, which equate to LCOEs from 6.9 to 17.2 cents/kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

Design of a Geothermal Power Plant With Solar Thermal Topping Cycle

Geothermal power plants are a reliable source of low-carbon power generation. However, modern electricity markets comprise relatively large proportions of variable renewable energy generation that may require power plants to flexibly dispatch energy. The power output, efficiency, and dispatch flexibility of a geothermal plant can be enhanced by integrating solar thermal energy into the system, as well as possibly compensating against ambient temperature variations. Concentrating solar thermal (CST) can generate temperatures much higher than conventional geothermal systems. Using a solar topping cycle is one way to efficiently convert high-temperature solar heat to electricity while also cascading lower-temperature heat to the geothermal power cycle, thereby increasing its power output and possibly its efficiency. A hybrid power cycle design is proposed and simulated using SimTech IPSEpro process modeling software. The design configuration depends on the expected temperature of the geothermal resource and the quantity of solar heat added at the design point. These design considerations are described and expected performance is calculated. The solar heat addition varies throughout the day and year; therefore, off-design models are necessary to assess the impact of solar availability (and ambient temperature) on the power plant performance. Off-design models are developed and combined with hourly weather data to facilitate an evaluation of annual system performance.

concentrating solar power↗

Design of a Geothermal Power Plant With Solar Thermal Topping Cycle: Preprint

Geothermal power plants are a reliable source of low-carbon power generation. However, modern electricity markets comprise relatively large proportions of variable renewable energy generation that may require power plants to dispatch energy flexibly. The power output, efficiency, and dispatch flexibility of a geothermal plant can be enhanced by integrating solar thermal energy into the system, as well as possibly compensating against ambient temperature variations. Concentrating Solar Thermal (CST) can generate temperatures much higher than conventional geothermal systems. Using a solar topping cycle is one way to efficiently convert high-temperature solar heat to electricity while also adding lower-temperature heat to the geothermal power cycle, thereby increasing its power output and possibly its efficiency. A hybrid power cycle design is proposed and is simulated using SimTech IPSEpro process modelling software. The design configuration depends upon the expected temperature of the geothermal resource and the quantity of solar heat added at the design point. These design considerations are described and expected performance is calculated. The solar heat addition varies throughout the day and year, therefore off-design models are necessary to assess the impact of solar availability (and ambient temperature) on the power plant performance. Off-design models are developed and combined with hourly weather data to facilitate an evaluation of annual system performance.

concentrating solar power↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronic Hardware-in-the-Loop (PE-HIL): Testing Individual Controllers in Large-Scale Power Electronics Systems

Large power electronics systems like multi-port autonomous reconfigurable solar power plant (MARS) are increasingly being researched upon to integrate emerging energy sources. MARS connects photovoltaic (PV) systems and energy storage systems (ESSs) to high-voltage direct current (HVdc) links/grids and high-voltage alternating current (ac) transmission grids. As these large power electronics systems incorporate complex hierarchical control systems that are close-by and communicate fast, the control systems require an unique power electronic hardware-in-the-loop (PE-HIL) real-time architecture to evaluate individual controllers. In this paper, a PE-HIL real-time architecture is proposed to evaluate one of the hundreds to thousands of digital signal processors (DSPs) that are a part of the complex hierarchical control system. The DSP connects to a central processing unit (CPU) and a field programmable gate array (FPGA) that form a part of the upper levels of the control system. The DSP is part of the lower level of the control system. The proposed PE-HIL architecture is tested and evaluated. Preliminary test results are presented to showcase the concept.

Debnath, Suman↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Seminar 13 - Advanced Methods for Grid Integration of High-Performance Residential Communities

High-performance residential communities such as net-zero energy (NZE) and NZE-ready communities are emerging across the United States as many cities and states have committed to achieve ambitious energy efficiency and renewable energy goals between now and 2050. The achievement of these goals will transform the nation's communities into the holistic paradigms consisting of pervasive solar photovoltaics (PVs) and other renewable distributed energy resources, energy storage and flexible loads. However, integrating residential communities with high PV penetration may bring many challenges to the grid. For example, during many hours of the year, electric power is flowing out of PV-enabled homes and back into the grid. When this happens simultaneously in many nearby homes, distribution feeder voltage can be raised significantly. Intermittent solar power can also cause voltage flickers, leading to potential damages on both distribution feeder and home appliances. Existing solutions, such as PV curtailment, battery storage, and direct load control, are not able to address all the challenges in a cost-effective way. Better understanding is needed on how to deploy rooftop PV, how to predict building loads, and how to coordinate the homes in a community to enhance grid reliability. This seminar consists of four integral presentations that cover different aspects of a solution to these challenges. First, we will present an automated method to identify the best surfaces to deploy PV and size PV according to the PV penetration goals in a community. Second, we will present a streamlined way to create gray-box building models that are suitable for large-scale building-grid co-simulation. Next, we will present a data-driven method to estimate the end-use energy consumption to better coordinate the behind-the-meter resources to reduce utility cost, provide grid services, and improve renewable energy integration. Lastly, we will present a hierarchical control system that integrates the building models and the estimated non-dispatchable loads into the decision-making process to enhance the reliability and resilience of the residential community. Simulation results from an NZE-ready community in Fort Collins, Colorado will be presented in all four presentations and the guidelines on better grid integration of residential communities will be provided.

14 SOLAR ENERGY↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

Complementary relationship between small-hydropower and increasing penetration of solar photovoltaics: Evidence from CAISO

To achieve the 100% green electricity goal, we need to understand the relationship between resources in the market and identify the flexible clean resources (i.e., hydropower) to integrate power from wind and photovoltaic (PV). This paper reveals a complementary relationship between small hydropower plants and solar PVs in the California Independent System Operator (CAISO) based on the system-wide hourly generation data from 2013 to 2017. When the solar PV increases its portion in the generation mix by 1%, small hydro will increase its portion by 0.01–0.06%. Such response is obvious in the net demand peak hours, both morning and evening. The low operation cost, flexibility, and dispatchability of small hydro in CAISO explain this complementarity. Due to its benefit in emission and low Levelized Cost of Electricity (LCOE), it is suggested to consider more small hydro projects to accommodate additional PV capacity for the 100% green electricity goal. Our estimation indicates that the current feasible potential of small hydro is sufficient, if the relation stays the same over years. If developers can mitigate the environmental impact, more technical potential will become feasible. Thus, small hydro could integrate more solar PV and reduce the demand for natural gas plants and batteries.

13 HYDRO ENERGY↗

Security assessment and impact analysis of cyberattacks in integrated T&D power systems

In this paper, we examine the impact of cyberattacks in an integrated transmission and distribution (T&D) power grid model with distributed energy resource (DER) integration. We adopt the OCTAVE Allegro methodology to identify critical system assets, enumerate potential threats, analyze and prioritize risks for threat scenarios. Based on the analysis, attack strategies and exploitation scenarios are identified which could lead to system compromise. Specifically, we investigate the impact of data integrity attacks in inverted-based solar PV controllers, control signal blocking attacks in protective switches and breakers, and coordinated monitoring and switching time-delay attacks. Index Terms—Cyberattacks, security assessment, impact analysis, case studies, integrated power systems.

14 SOLAR ENERGY↗

Innovative Pathways to Net Zero Emissions: Subnational Strategies for Distributed Solar Deployment to Improve Grid Quality and Reduce Energy Costs in Argentina

Through Net Zero World, the National Renewable Energy Laboratory (NREL), the National Energy Secretariat of Argentina, La Pampa's Energy and Mining Secretariat, Pampetrol, and the Administracion Provincial de Energia de La Pampa (APELP) conducted an integrated analysis of the power system of the La Pampa province in Argentina. The study assessed the impact that solar and battery energy storage systems could have on the region grid's reliability and electricity costs, providing insights into long-term decarbonization strategies across Argentina. The analysis demonstrated that these systems are expected not only to help with decarbonization efforts but also to bolster grid resiliency, reduce line losses, and improve voltage regulation while lowering electricity costs. The paper offers a replicable framework for similar studies across other Argentine provinces, which could inform a national grid reliability plan and promote regional coordination. Such coordination will play a key role in supporting a nationwide clean energy transition as Argentina increases its share of renewable energy. By coordinating subnational energy plans with national strategies, Argentina can secure a resilient clean energy future, leveraging the substantial renewable resources available across its provinces.

14 SOLAR ENERGY↗

A Review of Behind-the-Meter Solar Generation Modeling and Forecasting

Solar photovoltaic systems largely integrated within the distribution grid are operated 'behind-the-meter' and power generation cannot be directly monitored by most utilities. The increasing penetration of behind-the-meter solar photovoltaic systems can deter efficient network and market operations due to variability and uncertainty in net load, which is exacerbated by limited visibility and the difficulty in analyzing the hosting capacity. Risk introduced by behind-the-meter solar contributions may hinder reliable and secure grid operations due to biased system monitoring and forecasts. Accurate behind-the-meter estimations, together with capacity and specification forecasts, thus play a key role in balancing supply and demand and this article reviews the pertinent literature, identifying key characteristics and predictive methods for efficient behind-the-meter solar photovoltaic generation. Forecasting is central to methods herein. The fundamental characteristics of behind-the-meter solar forecasting, including which methods are applicable for scenario-driven use cases, are driven by the metrics most useful for system-wide performance evaluation. To this aim, the literature is reviewed with a focus on forecasting applications for aggregate, regional behind-the-meter generation useful to bulk system and utility operations. As distinguished from net load forecasting, subtleties in these coincident tasks are explored before concluding with recommendations for current practice and future implementations.

behind-the-meter↗

Providencia Island High-Level Power System Capacity Expansion Analyses [Slides]

Results of a high level cost-benefit analysis using HOMER Pro software are presented for Providencia Island, Colombia. The analysis focuses on integrating solar photovoltaics (PV) and a battery energy storage system (BESS) into an existing diesel-only remote power system. The analysis uses fuel costs and discount rates provided by the stakeholders and NREL-derived capital cost estimates.

14 SOLAR ENERGY↗